how to check with remote error code daikin inverter AC
ฝัง
- เผยแพร่เมื่อ 8 ก.ย. 2024
- daikin split ac error code
SYSTEM CODE MEANING
0 = NORMAL
UA = INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0 = REFRIGERANT SHORTAGE
U2 = DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 = FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR )
INDOOR UNIT A1 = INDOOR PCB DEFECTIVENESS
A5 = FREEZE-UP PROTECTOR
A6 = FAN MOTOR FAULT
C4 = FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 = FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNIT E1 = CIRCUIT BOARD FAULT
E5 = OL STARTED
E6 = FAULTY COMPRESSOR START UP
E7 = DC FAN MOTOR FAULT
E8 = OVERCURRENT INPUT
F3 = HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 = HIGH PRESSURE CONTROL (IN COOLING)
H0 = SENSOR FAULT
H6 = OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 = DC CURRENT SENSOR FAULT
H9 = FAULTY SUCTION AIR TEMPERATURE SENSOR
J3 = FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6 = FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3 = ELECTRICAL PARTS HEAT FAULT
L4 = HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 = OUTPUT OVERCURRENT
P4 = FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
daikin split ac error code,
daikin ac error code,
asr service center,
error code daikin inverter ac,
daikin,error code l5 daikin,how to clear,daikin inverter ac,daikin air conditioner,daikin ac,daikin inverter ac error code,error code l5,inverter ac repair
bro great yar great itne sinear tachnisions hai laikin bewakoof hai aap ne jese explain keya hai na bhai great
Tnx. Brother
Nice sir aysi sabhi company ka ac ke bare me banaiye na
Ok
Superb bro
Many Many thanks Sir
Thanks 😊😊😊
1st year.
2 times gas leackage.
2nd year coil damaged.
Daikain charges 10000. 500 advance job sheet ready kal aayenge aur sahi kr denge sir.
Ek weak tak call kari but no response.
Urban company wale 2200 main sahi kr gaye with service complete.
Aur ab cooling nhi kr rha 15 error code dikha rha hai. Kabada AC Daikin.
Thanx sir
Need service in kolkata, I hv green light problem kindly suggest
Sir Mitsubishi ka bhi aisa arora bataiye na
Ok
Sir ji jb hum cansal ka buttun press kry gy to remot ko ac ke samny koi bhi buutun dba dy remot ka jo humy error show ho jahy
A/C k Remot ko ac k same rkh k he cansal ka button press kro the ae ga
Bhai same remote hai but ac me display nhi aa rahi .pls solution bato
A/c on ho rahaa h ???
is pepar ki photo send kardo sir ji
Ok
L5 ka matalab kya hai pcb khrab ya compressor?
inverter AC h ya normal
@@ACAndRefrigeratorRepairing Inverter AC hai Daikin ka Model no FTKP50QRV16
Bhai apne a1 k bare me nhi bataya .aur A1 me kitan kharcha aayega
Failure of indoor PCB. Kharcha 250 se 500 tk
Koi error hi nahi vo kaise pata chalega.... Green light blinking ho rahi he
Monitor kro kitni bar blink ho rhi h bech me chota sa back ly rhi hoga 8 ya 9 bar blink kr k
Cancel press se enter to setting se bahae kaise nikle?
1 minute wait kro automatically exit ho jae ga
Mera daikin inverter ac me U2 aa raha hey.3 sale dusri bar huva
Voltage ka issue h
Ya PCB m koi component khrab ho raha h
Remote se display light kese on hora he..
My remote is not working. Display me sab batara numbers ,changes but no beep sound . What could be the issue
सर idu का pcb मेँ बर्जर बीप नहीं चल रह है आवाज नहीं आ रह है बर्जर ठीक है
Cool air aa rhi hai par cooling nhi ho rhi h room main kya issue hoga
How to turn on display light?
Remote setting light bouton
@@ACAndRefrigeratorRepairing didn't find any light button in seetings!
Backlight button push for 2 second
@@nadeemahemad3815 There is no any kind of backlighting button
Will u please enter ur instagram. So i ask further🙂
E1 erro
Bhai is error code ka emage do na
Description m he
bhai L5 ka kiya esu hai
Daikin 1.5 green light suru bn suru bn ho rhi he solutions?
Koy error nyi aarha thoda hota he asa phir phele jesa normal ho jata he
J3 error code
A/C DISCHARGE PIPE TEMPERATURE SENSOR Error
Outdoor unit
Sir ac mai koi bhi error show nhi ho raha fir bhi outdoor unit nhi on ho rah ab kya kare
AC kon se company ka h
display nhi ac me to kase pata kre ki ac kutne temp. pr h
Daikin lia he to kafi bhugtna pdega...mera laga tbse paresan hu coil change ki bt noise nhi gyi...aage dekho aur hota he kya...
@@ravi271000 🤣🤣 kisne kha tha inverter AC lo
E5 ko kaise solve kre
00
Kya karna hoga
P4
L.A aata hai Daikin AC
Bhai ye phle ghanti hatao please....ye dimaagh kharab kerta Hai yaar video dekhne mai.... subscribe ker deta hun
A2 error aa raha hai
A/C kon sa ha