What are Non-Return Valves and How to Properly Install Them - Boiling point

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ม.ค. 2025

ความคิดเห็น • 22

  • @EnfernoMuzik
    @EnfernoMuzik 5 ปีที่แล้ว +5

    Just getting into boiler operations and I love these videos!

  • @MichaelB-84
    @MichaelB-84 5 ปีที่แล้ว +3

    Awesome information! Thanks for taking the "mystery" out of the inner workings of this valve.

    • @wareboilers
      @wareboilers  5 ปีที่แล้ว

      Thanks for the comment and glad we could help!

  • @carlos-vo1lr
    @carlos-vo1lr 5 ปีที่แล้ว +1

    please keep on doing this videos, they're so helpful. thanks

    • @wareboilers
      @wareboilers  5 ปีที่แล้ว +1

      Thanks for the comment and for watching!

  • @doubleg1239
    @doubleg1239 2 ปีที่แล้ว

    Thank you, awesome learning with great visuals

  • @nicsye12
    @nicsye12 5 ปีที่แล้ว

    Excellent video, I had not considered the turndown limitations of non-return valves. Thanks

    • @wareboilers
      @wareboilers  5 ปีที่แล้ว

      Glad we could help. Thanks for watching!

  • @timmydrews
    @timmydrews 10 หลายเดือนก่อน

    Can the disc plug smack against the top too?

  • @cck0728
    @cck0728 5 ปีที่แล้ว +3

    As usual excellent video. This is an angle plug type NRV. I have two questions:
    1) What does turn down mean (as mentioned in the end of this video)? What is burner turn down and valve turndown?
    2) There is no spring in this valve. So the only inertia is the weight of the plug and back pressure of header?
    Thanking you for your valuable time.

    • @AdrianButler86
      @AdrianButler86 5 ปีที่แล้ว +2

      I believe turn down is a ratio of your boiler hi to low firing rate. I could be wrong but my memory is telling me that cuz i read or heard it some where

    • @CheiithooCat
      @CheiithooCat 5 ปีที่แล้ว +2

      @@AdrianButler86 yes it is

  • @chrisspain2881
    @chrisspain2881 9 หลายเดือนก่อน

    Is it normal for condensate to leak by and raise the water level in the boiler? We have three boilers in parallel and one of them has been having this issue - at least that is what we think is happening. How do we fix this problem? Thanks for the video

    • @luciusbrutus13th
      @luciusbrutus13th 8 หลายเดือนก่อน

      Do you blow down the free blow periodically?

    • @chrisspain2881
      @chrisspain2881 8 หลายเดือนก่อน

      @@luciusbrutus13th from the drain plug on the valve itself? We don’t. Right now the drain plug is just a plug - no piping/valves attached to get rid of the condensate. Should something be added there?
      For context I’m a relatively new engineer

  • @scott5654
    @scott5654 2 ปีที่แล้ว +1

    Excellent, thanks ‼️

    • @wareboilers
      @wareboilers  2 ปีที่แล้ว

      You bet, thanks for watching!

  • @whatdoidonext2234
    @whatdoidonext2234 5 ปีที่แล้ว

    so, the banging that I hear is not always from pipes expanding and contracting from heat / changes in flow. Good to know and another preventative maintenance item to check!

    • @wareboilers
      @wareboilers  5 ปีที่แล้ว +2

      Always better to check on something that sounds off than to let it keep going and end up becoming a major problem! Thanks for watching!

  • @slickwilly4613
    @slickwilly4613 5 ปีที่แล้ว

    We have 2 low pressure boilers in parallel and one valve is not holding back the pressure. they dont look like the ones you are showing, they are just swing valve like a regular check valve you would see. Do we have the wrong type of valve?
    In case your wondering the boiler with the faulty valve does flood with water during the off cycle.
    I

    • @wareboilers
      @wareboilers  5 ปีที่แล้ว

      Since these are low pressure valves a swing check is the best one to use.
      These valves can take a beating when in service. The ones you have are likely to be worn out. Fortunately these valves are not expensive.
      If the header is discharging vertically a steam trap can be installed downstream to the check valve to eliminate the condensate as it forms in the vertical header. This will work as long as the swing check is not completely worn out.
      We also recommend two drip legs with traps on the collection header if you have a collection header. Two drip legs provide redundancy.
      Hopefully that helps! If you need more info please give us a call! Thanks for the question

    • @slickwilly4613
      @slickwilly4613 5 ปีที่แล้ว

      @@wareboilers the valves are brand new. only one of them seems to work