How to Design the Pile Cap for 2 piles

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ก.ย. 2024
  • In this video, we'll show you how to design a pile cap for 2 piles.
    This video will help you to design the perfect pile cap for your specific needs. We'll walk you through all the steps, and explain the reasoning behind each step. After watching this video, you'll be able to design the perfect pile cap for your needs in no time!
    My other videos
    Singly reinforced section design to EC2: • Singly reinforced sect...
    Depth of footing and reinforcement details: • Depth of footing and R...
    Cantilever slab reinforcement detailing: • Cantilever Slab Reinfo...
    Factors affecting workability of concrete: • 10 Factors Affecting W...
    Social Media platforms
    Facebook: / structuralguide
    LinkedIn: / structuralguide
    Twitter: / structuralguide
    Instagram: / structuralguide
    Pinterest: / structuralguide
    Like, Share, Comment, and Subscribe
    #pilecap #pilecapdesign #pilecaps

ความคิดเห็น • 13

  • @aneeshaunni1554
    @aneeshaunni1554 26 วันที่ผ่านมา

    Can you share the details of the bar arrangement according to the pile cap dimension?... lik e bottom first u bar in longer dimension or shorter?

    • @structuralguide
      @structuralguide  25 วันที่ผ่านมา

      We can have the critical bar at the bottom layer. That can be done. Since we tie the rebar, and is within the concrete, the necessary restrain is there for tension bars.
      You may also detail like a beam manner that distribution bare acts like a link too. In that case, reduction of the effective depth shall be considered in the design.

    • @aneeshaunni1554
      @aneeshaunni1554 25 วันที่ผ่านมา +1

      @@structuralguide thank you somuch

  • @binayaksamanta863
    @binayaksamanta863 ปีที่แล้ว

    Please make a video on 3 pile design

  • @fathimathangal1913
    @fathimathangal1913 ปีที่แล้ว

    At 14:52 how is the area just the effective depth, pls male that clear

    • @structuralguide
      @structuralguide  ปีที่แล้ว

      Area, here means the b x d
      b - width
      d - effective depth

  • @rashminsajeev2893
    @rashminsajeev2893 11 หลายเดือนก่อน

    Sir , how the Vc value 0.75 found out from table 3.8 bs 8110 using this v value?

    • @structuralguide
      @structuralguide  11 หลายเดือนก่อน

      Vc is obtained based on the 100As/bd and effective depth.

    • @rashminsajeev2893
      @rashminsajeev2893 11 หลายเดือนก่อน

      Sir, In our case, 100 As /bd = .72 and eff. Depth is > 400 . Couldnt find a value 0.75 (Vc) corresponfing to these data frm table 3.8?

    • @structuralguide
      @structuralguide  11 หลายเดือนก่อน

      Now it is clear what you are asking. The Vc that I have considered in the example is some approximation. The correct value needs to be obtained form the table based on the 100As/bd and as per effective depth.

  • @fathimathangal1913
    @fathimathangal1913 ปีที่แล้ว

    Can u pls make 10:45 clear

    • @structuralguide
      @structuralguide  ปีที่แล้ว

      We have to maintain the spacing of the pile to design the pile cap with the truss method. When the spacing of the piles is more, we have to use the bending theory; calculate the bending and shear and design like a beam.