Ohms vs. Continuity for HVAC techs

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ก.ค. 2024
  • I have heard HVAC technicians express confusion around using the Ohms scale or the continuity feature of their meters. This video will help HVAC techs identify the difference between Ohms and Continuity and when to use one over the other.
    Before you grab your free class, make sure to subscribe to my channel: bit.ly/SubscribeHVACTraining
    Sign up to get access to a free class “Using Digital Multimeters For HVAC” by going to my website and clicking on the "Subscribe" tab :
    hvactraining.squarespace.com/
    🔥🔥🔥 ACCESS USEFUL PLAYLIST 🔥🔥🔥
    Thermostat Mini Series bit.ly/howathermostatworks
    📍 FOLLOW HVAC Service Mentor 📍
    🔹 Official Site: hvactraining.squarespace.com/
    🔹 Facebook: / hvacservicementor
    🔹 Twitter: / hvacmentor
    🔹 LinkedIn: www.linkedin.com/in/ericshidell
    These training sessions are for qualified HVAC technicians or apprentices under proper supervision. None of these trainings are meant for DIYers or HVAC hobbyists.

ความคิดเห็น • 61

  • @zachosborne6577
    @zachosborne6577 ปีที่แล้ว +12

    Been in hvac since 2009 and a journeyman since 2012. I appreciate these basic simple tips and information. Thanks man.

  • @billminckler6550
    @billminckler6550 ปีที่แล้ว +3

    Excellent. Thank you for the distinction. Thank you for the alert that some pathways have a higher resistance! 👏

  • @Suicaedere666
    @Suicaedere666 3 ปีที่แล้ว +10

    This was an incredible video, 👏🙌. I thank-you very much for taking the time to create this video, as well as all of your other videos😀🙌❤

  • @michaelcostello6991
    @michaelcostello6991 3 ปีที่แล้ว +4

    Great discussion about this topic.

  • @jodystradesstuff5048
    @jodystradesstuff5048 ปีที่แล้ว +3

    What I wish you'd said was: "Continuity just tests Ohms and beeps if it's under about 50 ohms."

  • @sergiofranco7381
    @sergiofranco7381 3 ปีที่แล้ว +12

    Thanks for the thorough explanation and examples of what to use them on. One more gold nugget in my bank.

  • @mjmjersey
    @mjmjersey 2 ปีที่แล้ว +1

    Great video thank you

  • @PUBHEAD1
    @PUBHEAD1 ปีที่แล้ว +2

    Thanks soooo much for this. Much appreciated

  • @raymond3722
    @raymond3722 3 ปีที่แล้ว

    Thank's for that clarification.

  • @robburke8867
    @robburke8867 ปีที่แล้ว +1

    Thanks friendly. That was a darn good video. Bravo 👏

  • @thepitpatrol
    @thepitpatrol ปีที่แล้ว +1

    Thank you.

  • @dammo361
    @dammo361 ปีที่แล้ว +1

    great video,,,thank you

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC ปีที่แล้ว +2

    Use alligator clips when possible to ohm out a circuit or component. If you press hard or not hard enough....your reading will vary.

  • @andrewthacker114
    @andrewthacker114 2 ปีที่แล้ว

    Thanks

  • @offgrid2010
    @offgrid2010 3 ปีที่แล้ว +3

    Excellent video. Yes I could hear other sounds but not you speaking. My volume was fine on a previous youtube video. Thank you for excellent content.

  • @samwikiwiki7420
    @samwikiwiki7420 2 ปีที่แล้ว +1

    Good work bro. Don’t know why some didn’t like. Any way keep on Guten Abend

  • @dayannodarse3948
    @dayannodarse3948 9 หลายเดือนก่อน +1

    Best explanation Thanks a lot 🙏

  • @MuhammadKhan-gs9ym
    @MuhammadKhan-gs9ym หลายเดือนก่อน

    Thank you for the explanation!

  • @milanlipovic7349
    @milanlipovic7349 3 ปีที่แล้ว

    Great content again but I wish you would have also used a Fieldpiece meter 👍

  • @jamalbenthall151
    @jamalbenthall151 2 ปีที่แล้ว

    Great video

  • @donnierobertson3088
    @donnierobertson3088 3 ปีที่แล้ว +1

    Nice

  • @samwikiwiki3231
    @samwikiwiki3231 ปีที่แล้ว +1

    Guten Abend das Gerät kaputt machen
    Thanks allot .....great teacher...salute ....

  • @1953beckley
    @1953beckley ปีที่แล้ว

    I want to ask you if you can made a video on ohms that's not making a beep. Thanks Dennis

  • @genekastner8086
    @genekastner8086 3 ปีที่แล้ว +1

    Eric
    great informative video - volume very low and hard to hear

  • @sincityhvacr
    @sincityhvacr 3 ปีที่แล้ว

    great video do u have any tips on getting better reading rtu schematics and ladder diagrams ? thank you

    • @hvacservicementor
      @hvacservicementor  3 ปีที่แล้ว

      You bet! Go to www.hvacservicementor.com and get Electrical Schematics under the Techflix tab. That's a great start. The boot camp courses are also great resources.

  • @afghvacr
    @afghvacr ปีที่แล้ว

    Imagine you are on call with senior tech Diagnosing a bad compressor and ask this question 🤣

  • @Googlename699
    @Googlename699 ปีที่แล้ว

    When I measure ohm by fluke, it starts with a big number then goes down to a number. Why it does that? (e.g starts with 315.7 ohm then decrement down to 150 ohm)

  • @jp040759
    @jp040759 2 ปีที่แล้ว +1

    Toning a circuit is a carry over from Telephone repairmen tech terminology.

  • @essiemae8043
    @essiemae8043 4 หลายเดือนก่อน

    would be nice if you showed where you were putting your probes ...

  • @rodgraff1782
    @rodgraff1782 ปีที่แล้ว

    Motors should be tested for grounds with a meggohmmeter. I have several hand crank styles that can put out 1000volts to ground. They will pick up high resistance grounds that an ohmmeter can’t find, because it tests the motor with its running voltage or higher. It will cause near shorts to arch to ground, therefore testing the integrity of the winding insulation. A meter with a 9 volt battery can’t find these types of defects.

  • @stevenzavalajr8081
    @stevenzavalajr8081 3 ปีที่แล้ว

    How do u know how many ohms you should get when checking for ohms?

    • @hvacservicementor
      @hvacservicementor  3 ปีที่แล้ว +1

      That's a challenge which limits the overall value of measuring ohms at all. If you can compare your part to a known good unit, that can be helpful. Some compressor manufacturers publish ohm values, but they can be hard to find. Check out my class on electric motors to learn how to ohm out motors at www.hvacservicementor.com

  • @1971omi
    @1971omi 3 ปีที่แล้ว

    Hello
    I'm hvac tech. Can't find the answer for resistive load such as heat strip. As you said there is high value on resistance on it such as hot surface ignitor so question is if voltage value stays the same based on ohm law amperage gets lower if high resistance but in heat strip we have higher resistance value at the same our amperage drawn is higher which just contradiction to OHM law.
    I'm senior tech and train lots of technicians but can't find answers for t this?

    • @rodgraff1782
      @rodgraff1782 ปีที่แล้ว +2

      As a heat strip warms up, it’s resistance will increase. There is really no way to measure resistance on a live circuit. Any conductor will increase its resistance as the temperature of the wire increases. The molecules get farther apart with heat, and cause this rise. You could prove this by using a torch to heat the strip heater element while an ohmmeter is connected. The hotter the element gets, the higher the resistance will be. Hope this helps.

  • @wd8557
    @wd8557 3 ปีที่แล้ว +1

    I ohm everything period, I only use continuity to check for breaks in wiring or short to ground. If I am working on something bigger, motor's 25 hp and above that cost thousands of dollars, I am not trusting any meter with a 9volt battery. It's time to break out the Megger 420/2

  • @rickybailey7123
    @rickybailey7123 ปีที่แล้ว +1

    continuity and ohms so continuity is ohms when u put the meter in continuity mode it just beeps and shows ohms that's crazy I didn't know that

  • @raphaelm6149
    @raphaelm6149 2 หลายเดือนก่อน

    My multimeter does not beep when testing ohms ..

  • @jakem117
    @jakem117 3 ปีที่แล้ว +1

    Ah but is a contactor technically a load or a switch?
    I argue it's both by design. It's a load, that actuates a switch or set there of. Most text books specify it as a switch or control only. If we really dig into it, it is most definitely a load as well. Ever try and install high current rated contractors in a residential split system with the same voltage coil? Some transformers are incapable of maintaining the same potential difference through the coil as its electrical requirements are greater...
    Now the real question... Non positive displacement compressors... I.E: Centrifugals. How are they even compressors BY DEFINITION? ;) They're not

    • @oilandfireguy1739
      @oilandfireguy1739 6 หลายเดือนก่อน

      It's definitely a load that activates a separate switch. If the coil wasn't a load, it would short.

  • @louisvanniekerk7667
    @louisvanniekerk7667 2 ปีที่แล้ว

    I can not get into your website, you need a username and password. Can you help?
    Louis

    • @hvacservicementor
      @hvacservicementor  ปีที่แล้ว

      Website was in transition go to hvactraining.squarespace.com/

  • @bobb.6393
    @bobb.6393 2 ปีที่แล้ว +1

    Need stereo on voice

  • @Epicscrewdriver45
    @Epicscrewdriver45 ปีที่แล้ว

    Video notes :
    1) Ohms measures resistance
    2) continuity meant to see if a switch is “open” or “closed”
    Examples:
    Ohms -> compressor Motor

  • @brianbiggs3484
    @brianbiggs3484 2 ปีที่แล้ว

    👍👍✌️🇨🇦✌️🇨🇦✌️🇨🇦👍✌️

  • @JoeWere
    @JoeWere 2 หลายเดือนก่อน +2

    My right ear feels lonely.

    • @9bboy0lukk36
      @9bboy0lukk36 หลายเดือนก่อน +1

      Ok so it wasn’t just me lol

  • @Davidsavage8008
    @Davidsavage8008 ปีที่แล้ว

    If you can NOT get a steady reading of numbers on your meter when reading a coil on a contactor , I guarantee you that contactor is bad.

  • @dickfranco4312
    @dickfranco4312 ปีที่แล้ว

    so, what is wrong with the circuit ???

  • @knockitofff
    @knockitofff 3 ปีที่แล้ว +3

    god damn it, it's 2021, get a microphone that records in stereo, captain troubleshooter

    • @atefe5330
      @atefe5330 3 ปีที่แล้ว

      Hes high

  • @joehead1294
    @joehead1294 3 ปีที่แล้ว +3

    Continuity is a trickster and I'll tell you why. Some meters will only read to a certain value and above that they will give O.L. when you still have continuity. Surprised you left that out. I don't trust it of use it. Spec sheets often don't give the range of operation. You have to 'test' your meter to find it's values. Course that's part of knowing your equipment.

    • @hvacservicementor
      @hvacservicementor  3 ปีที่แล้ว +1

      Joe, thanks for your input. On a manual ranging meter, continuity is also the lowest scale range of the meter. If the resistance of the load you are checking is higher than that scale, you will get OL. 200 ohms is common. Beepers will stop sounding around 40 ohms. Some meters may be less. Like you said, you never know what you're going to get. I like the "trickster" description. Very true.

  • @bmillwood6666
    @bmillwood6666 8 หลายเดือนก่อน

    Rookies use the tone. I hate the tone.

    • @hvacservicementor
      @hvacservicementor  8 หลายเดือนก่อน

      While toning the circuit is often unreliable, testing for continuity does have its place as long as techs understand the limitations.