G+4 Building designing as per DEWA Regulation--- Part-2

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 มี.ค. 2024
  • Distribution of light load inside flats and Common Area
    Distribution of power loadinside Flats and Common Area
    Circuit formation of light and power load
    HVAC load distribution and circuit formation
    Plumbing load
    fire fighting load
    load schedule preparation of FDB
    load schedule preparation of SMDB's.
    oad schedule preparation of MDB
    SLD preparation
    load cand preparation
    Voltage drop calculation
    stand by Generator Rating Calculation
    Transformer size calculations
    #dewa #dewa19 #dewa #design #g+4 #regulation2017 #regulation

ความคิดเห็น • 24

  • @sls8080
    @sls8080 9 วันที่ผ่านมา

    very informative video
    well explained
    keep on doing more of such kind🙏

  • @nidhinkrishna2683
    @nidhinkrishna2683 2 หลายเดือนก่อน +1

    Great work ❤

  • @senworld8197
    @senworld8197 24 วันที่ผ่านมา

    Great bro ...such a great classes...i found your channel lucky....after searching 1000 of videos...

  • @hussainahmad8403
    @hussainahmad8403 4 หลายเดือนก่อน +2

    Thank you sir

  • @THE_MATHS_PAPA
    @THE_MATHS_PAPA 4 หลายเดือนก่อน +1

    Best content ❤

  • @safwanahammed-qs8qw
    @safwanahammed-qs8qw หลายเดือนก่อน

    Great effort..! thank you

  • @HariKrishnan-nr1ev
    @HariKrishnan-nr1ev 4 หลายเดือนก่อน +1

    Thank u somuch brother

  • @THE_MATHS_PAPA
    @THE_MATHS_PAPA 4 หลายเดือนก่อน +1

    Please make a separate video on how to do naming of electrical items like switch, sockets etc

  • @dinakaransabari7600
    @dinakaransabari7600 4 หลายเดือนก่อน +1

    sir please make separate vedio for dewa important key points.. which not in designing vedio

  • @naserkhan313
    @naserkhan313 3 หลายเดือนก่อน +1

    Assalamualykum engineer
    For spare we need to consider a minimum load.. And for space zero load to be consider

  • @salahhilali875
    @salahhilali875 11 วันที่ผ่านมา

    there are some inaccuracies, only window type units can be connected in a single circuit not normal ones which dewa wont allow, why oven and hob requires 6000 w for gas system we can provide two spur outlets with 50 w each

  • @ilaiyaraja4217
    @ilaiyaraja4217 3 หลายเดือนก่อน +1

    It is not recommended to connect two FCUs to a single circuit.IT means that if one machine fails, the elcb will trip, causing both fcus to stop working.

    • @electricalconcept32
      @electricalconcept32  3 หลายเดือนก่อน

      As per DEWA regulations two Air conditioning unit can be fed from one circuit. Watch my video model question of DEWA Exam I have show the screen shot for the same. Thanks

    • @kingofking8012
      @kingofking8012 3 หลายเดือนก่อน

      It's only for window AC

  • @abdulrahmanshah6040
    @abdulrahmanshah6040 2 หลายเดือนก่อน

    Hi dear such a nice video and good explanation i am a mechanical engineer watching your video to have a brief about electrical design. Kindly consider that some viewers doesn’t know about electrical standards. On 16:24 I didn’t understand standard about ring ckt.

    • @electricalconcept32
      @electricalconcept32  2 หลายเดือนก่อน +1

      I will try to consider . Jab do mai ek breaker se nikle aur kisi circuit ke first aur last end se connect ho to ise circuit ko ring circuit kahte h

    • @abdulrahmanshah6040
      @abdulrahmanshah6040 2 หลายเดือนก่อน

      @@electricalconcept32 later in saw in another video.

    • @abdulrahmanshah6040
      @abdulrahmanshah6040 2 หลายเดือนก่อน

      @@electricalconcept32 but still thank you.

    • @abdulrahmanshah6040
      @abdulrahmanshah6040 2 หลายเดือนก่อน

      Try to make videos on MCC panels with each component explaining.

  • @aneesrahman1287
    @aneesrahman1287 หลายเดือนก่อน +1

    Can you share that regulation pdf?

  • @sunilkumarakediwala2972
    @sunilkumarakediwala2972 4 หลายเดือนก่อน +1

    Really Great information..... ❤