- 103
- 265 054
Electrical Concept
เข้าร่วมเมื่อ 8 พ.ย. 2018
Electrical Engineer
วีดีโอ
G+4 Building designing as per DEWA Regulation---Part-7 || SMDB DESIGNING
มุมมอง 1.6K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power load inside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation ...
G+4 Building designing as per DEWA Regulation --- Part-6 || SMDB Designing.#dewa #regulation2017
มุมมอง 1.2K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power load inside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation ...
G+4 building designing as per DEWA Regulation--- Part-5 #dewa #regulation2017
มุมมอง 1K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power load inside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation ...
G+4 building Designing as per DEWA Regulation--- Part-4 #dewa #regulation2017
มุมมอง 9239 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power load inside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation ...
G+4 Building designing as per DEWA Regulation ---Part-3. #dewa #regulation2017
มุมมอง 1.2K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power load inside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation ...
G+4 Building designing as per DEWA Regulation--- Part-2 #dewa #regulation2017
มุมมอง 3.2K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power loadinside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation s...
G+4 building designing as per DEWA Regulation--- Part-1 #dewa #regulation2017
มุมมอง 1.8K9 หลายเดือนก่อน
Distribution of light load inside flats and Common Area Distribution of power loadinside Flats and Common Area Circuit formation of light and power load HVAC load distribution and circuit formation Plumbing load fire fighting load load schedule preparation of FDB load schedule preparation of SMDB's. oad schedule preparation of MDB SLD preparation load cand preparation Voltage drop calculation s...
DEWA Exam Model Questions. #dewa/#regulation2017
มุมมอง 3.9K9 หลายเดือนก่อน
1. Dewa exam model question 2. Dewa Regulation 2017 th-cam.com/video/NedUa8nZc4U/w-d-xo.html Dewa Exams Model Questions #dewa #dewa19 #regulation2017 #regulation #dubai
How to size earth continuity conductor & equipotential bonding conductor asper DEWA& ADDC Regulation
มุมมอง 8339 หลายเดือนก่อน
how to do the selection of ECC cable size as per DEWA and ADDC Regulation. how to select the equipotential bonding conductor as per DEWA and ADDC Regulation difference Between EARTH CONTINUITY CONDUCTOR AND EQUIPOTENTIAL BONDING CONDUCTOR #ecc #earthbound #dewa #addchannel #dubai #abudhabi #earthing th-cam.com/video/ckPKEMqH15E/w-d-xo.htmlsi=sicecDfmhNUzeKyy Difference between grounding, earthi...
Designing of Final Distribution Board Load schedule as per DEWA Regulation - Part-2
มุมมอง 1.2K9 หลายเดือนก่อน
power outlet placement in 2BHK light fixture distribution in 2BHK circuits formation for power outlet Circuit formation for light fixture Load schedule designing as per DEWA Regulation MCB rating selection as per DEWA Regulation ELCB rating selection as per DEWA Regulation wire and cable size selection as per DEWA Regulation Main Isolator Rating selection as per DEWA Regulation #dewa Regulation...
Designing of the Final Distribution Board Load schedule as per DEWA Regulation.
มุมมอง 3K9 หลายเดือนก่อน
power outlet placement in 2BHK Circuit formation for power outlet light fixture distribution in 2BHK Circuit formation for light fixture DEWA Regulation related to lighting, power outlets, Final Distribution Board Load schedule designing as per DEWA Regulation. #dewa #regulation #poweroutlet #lighting #dewa19 #dubai
What causes a motor to overload?
มุมมอง 1729 หลายเดือนก่อน
How do you check motor overload? How do you troubleshoot a motor overload? prevention of motor from overload symptoms of motor overload rotor lock pull out torque shafts misalignment poor ventilation higher ambient temperature under Design Phase loss bearing failure frequently On and off nuisance tripping fluctuating power supply aging of motor poor lubrication wrong operation against duty cycl...
How to select the Breaker, Contactor and OLR rating for a Motor in DOL starter technique?
มุมมอง 1.9K9 หลายเดือนก่อน
How to select contactor rating for A DOL starter? How to select breaker rating for A DOL starter? How to select OLR rating for A DOL starter? How do I choose an overload relay for my motor? What is the overload setting for DOL motor? What is the overload setting for a motor? #contactor #design #overload #relay #breaker #calculation What is AC1 AC2 AC3 and AC4 Contactor What is the different typ...
Why Overload relay required with motor as the MCB/MCCB is capable to provide overload protection?
มุมมอง 56110 หลายเดือนก่อน
Why is the Overload relay required in the motor circuit, though the Breaker already has a provision for overload protection? Calculations of Breaker,Contactor, and OLR for DOL starter. #olr #contactor #mcb #mccb #breaker #overload #relay #design #calculation #selection
Difference Between Contactors and Relays
มุมมอง 35610 หลายเดือนก่อน
Difference Between Contactors and Relays
Difference Between Overcurrent, Overload, Short-circuit and Earth fault.
มุมมอง 69610 หลายเดือนก่อน
Difference Between Overcurrent, Overload, Short-circuit and Earth fault.
Final Distribution Board(FDB) Designing as per FEWA Regulations
มุมมอง 1.2K10 หลายเดือนก่อน
Final Distribution Board(FDB) Designing as per FEWA Regulations
Difference between Alternator and Generator.
มุมมอง 4.7K2 ปีที่แล้ว
Difference between Alternator and Generator.
How to request and review Material Technical Submittals?
มุมมอง 3.6K2 ปีที่แล้ว
How to request and review Material Technical Submittals?
Difference Between Induction Motor and Synchronous Motor
มุมมอง 8752 ปีที่แล้ว
Difference Between Induction Motor and Synchronous Motor
DEWA Regulation related to LV Room and Service Electrical Room.
มุมมอง 9K2 ปีที่แล้ว
DEWA Regulation related to LV Room and Service Electrical Room.
Why transformer rating is expressed in KVA but the Motor rating in KW
มุมมอง 1.5K2 ปีที่แล้ว
Why transformer rating is expressed in KVA but the Motor rating in KW
Difference between VFD and Soft Starter!
มุมมอง 1.1K2 ปีที่แล้ว
Difference between VFD and Soft Starter!
Part--3 What is VFD and how its control the speed of the Motor.
มุมมอง 3882 ปีที่แล้ว
Part 3 What is VFD and how its control the speed of the Motor.
Part---2 What is VFD and how its control speed of the Motors
มุมมอง 3732 ปีที่แล้ว
Part 2 What is VFD and how its control speed of the Motors
What is VFD and how its control the speed of Motor---Part-1
มุมมอง 7752 ปีที่แล้ว
What is VFD and how its control the speed of Motor Part-1
the capacitor bank was installed before electrification.... We can review the pf of building after system working only then apfc installed better Commonly we expect the pf is 80% only
As per your chart 700mm cable tray available 692.5 is after step 5, above 692.5 - 700 is a good option??
I have developed an automation tool that allows you to create a cable schedule in just minutes." Let me know if you'd like to refine it further!
C class mccb with stand 5-10× rated current then why mccb rating will be increased?????
B/w load and Rccb, switch has been fixed Load operated by switch only When load is off phase current does not pass through the load bcoz switch is in off condition , then leakage current how happened??? When load is in off condition 3:59
Very good explain sir
6:07 Eg: I am a diploma holder in EEE 5 year uae Experience If i have supervisor visa Can i apply for it
thank sir please hidi spk
Please upload how to select generator size for small indestri generator size please sir
I have been looking for this information. Thanks!
Exactly what I was looking for, good info
Great helpful video. Thank you for ur valuable time.
Please guide me first we have to take lighting ckts as dewa can give approval for power ckt first
Sir you miss sin@ to calculate current rating I = Kvar/ 1.732×400x0.6
Hi, for question no.11, the answer is 200A not 400A. Refer DEWA Regulation page no. 38 & 39
Thanks for explanation
Excellent 👌🏻
Bring vedio on ADDC practical test as well , they are taking VIVA test as well.
Thanks Sir
Your What you experienced in life
Electrical site engineer or engineer interview questions make videos on this topic
Brother plz . Make a video on your experience engineer interview questions
An excellent explanation, sir! Sending thanks from California.
bhai heavily informative and GOOD WORK
Great bro
Good explanation bro
Great informative video ..
❤💎
Then what will be the difference between single line to ground fault and earth fault, as in both of them one phase wire gets in contact with earth/ground?
16
Very well explanation. Could you please share how is the pipe size related in this calculation. Thanks
Awesome explanation ❤
Thanks.... Any specific load limit for DB, SMDB? Suppose if we have to provide another SMDB after a particular load. Pls reply..
Great work
Thanks Bro, waiting for new videos.
Thanks
Thank you somuch sir
Superb !!!
Current carrying capacity of the cable must be greater than load current/correction or derating factor. But why are you calculating derating current carrying capacity for selected cable. We have to select the cable after getting the value based on the above formula. No need to calculate derating current for selected cable.
Please to consider ambient temperature derating in cas operating over than the standard design temperature (IEC 30°C)
Bro question no. 11. I think answer is option B, 12 single phase circuits. Please reply I have exam tomorrow 😢
Hello sir it will great full if you please provide material as well
Best video thanks v much
❤
❤
❤
❤
❤
❤
I'm just asking, is it necessary not to change the percent in the decimal number before multiplying it, because I investigated your solution and I changed the percent in decimal before multiplying, so my answer is very different from your answer.