How to Leak Test an AC With Nitrogen Pressure

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ก.ค. 2024
  • In another one of our animated air conditioning how to videos Bryan explains How to Leak Test an AC With Nitrogen Pressure.
    Read all the tech tips, take the quizzes
    and find our handy calculators at www.hvacrschool.com

ความคิดเห็น • 87

  • @evertvalencia920
    @evertvalencia920 3 ปีที่แล้ว +23

    I love the way your teache , I wanna know more about A/C and Refrigeration, thank you

    • @DanO181919
      @DanO181919 3 ปีที่แล้ว +2

      This is one of the best channels to learn on. Another good channel is AC Service
      tech.

    • @rajendraenglishclasses6465
      @rajendraenglishclasses6465 3 ปีที่แล้ว

      Great ways of explanation

    • @marcdorizar5742
      @marcdorizar5742 ปีที่แล้ว

      @@DanO181919 another great one is word of advice.

    • @DanO181919
      @DanO181919 ปีที่แล้ว

      @@marcdorizar5742 yes, I’m subscribed to that channel as well. 👍🏻

  • @craighvac1808
    @craighvac1808 3 ปีที่แล้ว +9

    Never knew what a hard shut off Txv was, seen that happen many times pressure testing splits. Thanks for the info!

  • @simplescrapping
    @simplescrapping 3 ปีที่แล้ว +8

    Greetings from Greece😃. I'm a hvac technician and I have watched all of your video. I have to say that I learned (or understand) a lot of things. Keep the good work😉

  • @ardichico205
    @ardichico205 2 หลายเดือนก่อน

    your video is the best one i've came across, ive been looking for 2 or 3 days, yours is very simple , straight steps that didnt go over my head or confused me . Thanks !!!!!😁😁😁😁🙌🙌🙌🙌

  • @osamajassim5204
    @osamajassim5204 3 ปีที่แล้ว +2

    Excellent way of teaching,god bless you.

  • @LongTrout
    @LongTrout 11 วันที่ผ่านมา

    Great Vid. Proper Procedure and Profound Techniques Produce Perfect Service Performance.

  • @fawzannn
    @fawzannn 3 ปีที่แล้ว +2

    Thanks for a wonderful explanation

  • @devbella5223
    @devbella5223 3 หลายเดือนก่อน

    Ahh wow lots of good info here- I love the core tools and the probes… less leak points this is great- need to save up for some probes, just ordered a testo 550s hoping they’re good

  • @kwj21st
    @kwj21st 3 ปีที่แล้ว

    Thanks for the useful video.

  • @gadgethunter5732
    @gadgethunter5732 3 ปีที่แล้ว +7

    I would add . Even after recovery to prepare for a pressure test , the system will have some refrigerant in it . Do a quick pressure test to eliminate any huge leaks . Purge the system. Pull a quick vacuum to try and remove some of that residual refrigerant { in the compressor oil etc } The extra residual refrigerant will mess with pressure /temp swings way more than just nitrogen. And for you new guys that might have just glanced the part about a 600 psig test pressure, thinking more pressure is better ? Remember, a compressor shell can experience tons and tons of pressure on its walls. Add too much pressure and it can become a bomb. Going to extremes on pressure testing can become deadly.

  • @halleffect1
    @halleffect1 2 ปีที่แล้ว

    very good info, thanks

  • @michaelstaley9979
    @michaelstaley9979 3 ปีที่แล้ว

    Great video.

  • @Vore667
    @Vore667 2 ปีที่แล้ว

    Excellent. Thanks!

  • @AutoTechWorld_DIY
    @AutoTechWorld_DIY ปีที่แล้ว

    That was a well made video. Thank you

  • @sunimalfernando4347
    @sunimalfernando4347 3 หลายเดือนก่อน

    Thank you!!

  • @charliewingard6244
    @charliewingard6244 2 ปีที่แล้ว

    Thanks!

  • @eugeneb3682
    @eugeneb3682 3 ปีที่แล้ว

    Thanks

  • @MarcinDrozdowskiMMM
    @MarcinDrozdowskiMMM 4 หลายเดือนก่อน

    Very valubale. Thank You.

  • @HCheatNcool
    @HCheatNcool 2 ปีที่แล้ว

    Sman 480v has a tightness test that accounts for temp which is nice

  • @kirill26reg
    @kirill26reg 3 ปีที่แล้ว +5

    Спасибо!!! thanks in russian!!!

  • @raymondlaine9617
    @raymondlaine9617 10 หลายเดือนก่อน

    Who/how are you making these animations? Love it.

  • @davids8133
    @davids8133 3 ปีที่แล้ว

    Question unrelated to latest video: What temperature difference if any can be expected on a gas furnace in heat mode across the a/c evaporator coil?

  • @genepierson1728
    @genepierson1728 3 ปีที่แล้ว

    Do you need to pressure test on both the highside and lowside scrader valves?

  • @spencerwilliams3385
    @spencerwilliams3385 12 วันที่ผ่านมา

    New to the trade. How often do you test your manifold/measurement equipment for leaks?

  • @ChuckBaggett
    @ChuckBaggett 11 หลายเดือนก่อน

    Can at ultrasonic detector detect dry nitrogen? I see some advertised as doing so. An AC tech said they can't, but that might be because I suggested it.
    Also, nitrogen lets you use soap bubbles, hear it, and anything else.

  • @danleitner1635
    @danleitner1635 2 ปีที่แล้ว

    What brand of core removal tool, with side port, do you recommend?

  • @kevinvega1572
    @kevinvega1572 2 ปีที่แล้ว

    When adding nitrogen for a leak test do you guys recover all the freon before adding the nitrogen or do you add the nitrogen with freon in it

  • @MrMelo313
    @MrMelo313 ปีที่แล้ว

    Do you have to pump the system down/remove all refrigerant before nitrogen testing? Does it also need to be vaccumed after everything?

  • @cj691
    @cj691 2 ปีที่แล้ว +1

    That is a Victor gauge. The Western HVAC regulators have fixed test pressures.

  • @soleilsoleil8287
    @soleilsoleil8287 3 ปีที่แล้ว

    suuuuuuuuuuper vid.

  • @gilbertjaramillo8735
    @gilbertjaramillo8735 หลายเดือนก่อน

    My ac compressor and condenser have no refrigerant, so I need to do a pressure test on the whole system. Can I open the service hi and lo valves so the nitrogen can go thru both the compressor and condenser or should only the evaporator and its lines be checked? Same question to do a vacuum test? All the system or just the evaporator side?

  • @swamiadharpanda3646
    @swamiadharpanda3646 3 ปีที่แล้ว

    Saluting you sir

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 3 ปีที่แล้ว

    Did big blue change there product? I bought a 1 gallon jug to refill my spray bottle. I noticed the new stuff is thicker. Nothing on the jug says to dilute it.

  • @Howie875
    @Howie875 3 ปีที่แล้ว +6

    If you pressure test a system without having the service valves front seated, you will introduce this high pressure to the inside of the compressor shell, which is normally the low side pressure when it is running or equalized pressure while it is off .A 410a system can have pressures at the discharge line of over 500 psig when it is running, but this is not the pressure that the compressor shell is ever exposed to. There would be no problem with the heavier duty semi hermetic compressors but a thinner hermetic compressor could rupture under these pressures. I used to pressurize systems to 400 psig all the time until I read some information from Copeland compressors that ( from what I remember) recommended a maximum of 200 psig on the old R-22 compressors. May be higher for the 410a systems but I think 600 psig is excessive . You might want to recheck that.

    • @jeffb8437
      @jeffb8437 3 ปีที่แล้ว +1

      I believe it’s 350 psig max on the compressor shell R22 or 410. The weld around the shell and terminals being the week links

    • @sqeekykleen49
      @sqeekykleen49 2 ปีที่แล้ว +1

      Most have a plug in the bottom of the comp shell. When exposed to extreme heat as in a wildfire/grassfire, or structure fire this rupture disc expels an instant cloud of refrigerant and almost all of the oil in the can. Seen a few, very scary for g public.

    • @sqeekykleen49
      @sqeekykleen49 2 ปีที่แล้ว

      Some pop the disc where the leads connect.

    • @Howie875
      @Howie875 2 ปีที่แล้ว +1

      @@sqeekykleen49 In the larger commercial equipment I have seen fusible plugs that will turn into a liquid form and blow the charge at a predetermined temperature in case of excessive temperature and I have also seen pressure relief valves that are actuated at a certain PSI which is always higher that the high pressure switch rating for that particular unit. Was once silver soldering on a flat circuit on a dual circuit unit and inadvertently let my torch get to close to the fusible plug on the other circuit which caused it to melt and it released the molten metal and a stream of liquid refrigerant right at my face. Was lucky enough to somehow walk away unscathed from that one,

  • @rhumzalicante3822
    @rhumzalicante3822 5 หลายเดือนก่อน

    Can i use SCBA(Self Contained Breathing Apparatus) instead of Nitrogen tank? For leak test

  • @djguyvah8769
    @djguyvah8769 9 หลายเดือนก่อน

    Great

  • @sterlingarcher46
    @sterlingarcher46 3 ปีที่แล้ว +6

    For us Europeans it blows our minds that you lot are still using freon as a tracer gas , we stopped doing that years ago because its sooo forbidden !
    We use Trace-a-gas which is a mixture or 95% nitrogen and 5% hydrogen, then you just use a hydrogen electronic detector and voilà.
    And now they make electronic leak detectors that react to HFC , HFO and hydrogen so you only really need one leak detector which is very handy.
    There's really no reason to vent refrigerant anymore to be honest.

    • @tonyjr9757
      @tonyjr9757 3 ปีที่แล้ว

      We use trace-a-gas too - for strength, pressure and first leak check all in one, then to OFN for triple evac. Hydrogen being the smallest molecule should reveal the smallest of leaks.

  • @frankduarte7109
    @frankduarte7109 6 หลายเดือนก่อน

    How long do you purge the lines for before pressuring the system

  • @user-vy2sx9hn1x
    @user-vy2sx9hn1x 2 ปีที่แล้ว

    I have one question : What is the less purity of Nitrogen we must use for leak testing ???

  • @Armikrizaful
    @Armikrizaful 2 ปีที่แล้ว

    Nice video, is there any standar for nitrogen pressure for leakage test?

    • @tonyp6088
      @tonyp6088 4 หลายเดือนก่อน

      Hi there, that is a really good question and I'm surprised it wasn't covered in this video given that's the most important part.
      The answer is the test pressure should be 63 degrees Celsius saturated temperature of the refrigerant used. For example if you are using R134a 63 degrees is approx 1700kpa. You you would not pressure test above that. And for the low side of the system it is advised not to exceed 45 degrees sst.
      I hope this helps someone. Remember different refrigerant operate at different pressures. The pressure test needs to be at the highest operating pressure which is 63 degrees Celsius. (High side)

  • @markfowler9692
    @markfowler9692 3 ปีที่แล้ว +1

    Soooo what about Mini split systems - Only one evacuation port on the Suction line... Please explain how to do this on Minisplit systems...Recently started following your chnl, if you have already addressed this then please send me to the video etc...Thanks and love your videos !!!!

    • @justinrichard4190
      @justinrichard4190 3 ปีที่แล้ว

      the liquid and suction is basically a loop, you only need one port to add pressure, i usually go around 500 lbs on mitsubishi. then bubble check every flare, i usually bubble test then go around and hit them again before i wipe them off.

    • @Papasquatch73
      @Papasquatch73 3 ปีที่แล้ว

      Depends on the size mini. A lot have two ports

  • @rajarmk8850
    @rajarmk8850 2 ปีที่แล้ว

    Indoor or out door split AC checking pressure 380 it's wrong or right

  • @kevincowan7131
    @kevincowan7131 11 หลายเดือนก่อน

    What is the allowable drop after an hour ???Say you pressurize the system with 250 what is accessible ?75 degrees??

  • @mikecastillo5941
    @mikecastillo5941 3 ปีที่แล้ว

    Question for all you intelligent HVAC people . What is the Max pressure you would pressurize a new lineset with a new condensing unit with charge behind the service valves . Would you worry about forcing nitrogen into the condensing unit with to high of testing pressure ?

    • @Wpg204wpg
      @Wpg204wpg ปีที่แล้ว

      I always think about that .especially if I'm pumping down to leak search . Those valves always tend to have trace refrigerant in them .

  • @80SWoods
    @80SWoods ปีที่แล้ว

    Do you have to use Nitrogen gas to pressure test? I’m installing my own system and have welding tanks on hand which are argon/O2 which have the same attachments as Nitrogen. I’m thinking that once you’re done testing and open the lines to vacuum pump, any Nitrogen has leaked out anyhow. Do you think it matters?

    • @bryanswanson5007
      @bryanswanson5007 ปีที่แล้ว

      Nitrogen only

    • @keithosterkamp6207
      @keithosterkamp6207 ปีที่แล้ว

      In the presence of any moisture CO2 in your weld mix will form carbonic acid and you don’t want that circulating in your system.

  • @johannesvangalen2300
    @johannesvangalen2300 3 ปีที่แล้ว

    Do you use dry nitrogen?
    If so where can you purchase?
    Thanks

    • @tonyruiz2046
      @tonyruiz2046 2 ปีที่แล้ว

      HVAC supply distributors and welding supply distributors carry the dry nitrogen tanks and pressure regulator that you'll need.

  • @astromaddox1989
    @astromaddox1989 ปีที่แล้ว

    Do I leave the nitrogen tank open while waiting to see a pressure drop

  • @ffrgdert540
    @ffrgdert540 2 ปีที่แล้ว

    Hi, can anyone here let me know if its ok to charge r22 to a converted 407c system? I have a old r22 walk in cooler that was changed to 407c changed compressor . But there was a small leak, and the tech charged r22. Please let me know if that will cause a issue to the compressor. Appreciate your reply.

    • @sambaron1319
      @sambaron1319 2 ปีที่แล้ว

      No! R22 is mineral oil. 407c is POE oil...

  • @Vikis42
    @Vikis42 2 ปีที่แล้ว

    Sir ham 600psi peresure dety hin par suba kam hoa hota ha 560psi leakg b nhi ha ...kia masla ho skta ha

  • @johndoe-zz1nr
    @johndoe-zz1nr 2 ปีที่แล้ว

    How much the test should cost

  • @Bryan-Hensley
    @Bryan-Hensley 3 ปีที่แล้ว +18

    Never ever ever ever ever ever put more than 350 PSi in a system. The compressor shell is rated around 350 PSI. The shell is never exposed to the output pressure of the compressor. 33 years experience working on heatpumps.

    • @achempel46
      @achempel46 3 ปีที่แล้ว

      Copeland says 150psi

    • @merckxherve9116
      @merckxherve9116 2 ปีที่แล้ว +3

      Daikin ask 725 PSI for warranty in Europe. 350PSI is to low for detect very small leaks.

    • @213BRANDONP
      @213BRANDONP 2 ปีที่แล้ว +3

      LOL you're all right and you're all wrong one size never fits all just follow the manufacturer recommendation I assure you they know what it can handle

    • @213BRANDONP
      @213BRANDONP 2 ปีที่แล้ว

      @@achempel46 unfortunately it's usually not feasible to go off of Copeland's suggestion of course they don't want any load put on their compressors but if the system operates at higher pressure and they're telling you to test for the test on whichever pressure is higher
      Copeland also recommends no less than 20° super heat but good luck finding a manufacturer that agrees

    • @213BRANDONP
      @213BRANDONP 2 ปีที่แล้ว

      Myself I always just go off the low pressure max PSI stated right on the plate

  • @knutrichardvanderloock7914
    @knutrichardvanderloock7914 10 หลายเดือนก่อน

    Is there a reason why you are using nitrogen? Can I use co2?

  • @Joy-tb1cp
    @Joy-tb1cp 3 ปีที่แล้ว +1

    And how is a leak fixed if one is found when nitrogen pressured?

  • @MrSprintcat
    @MrSprintcat 3 ปีที่แล้ว +4

    Don't put the r410a in as vapor you will screw up the whole 30 pound jug

    • @pedrocastano6410
      @pedrocastano6410 10 หลายเดือนก่อน

      I would like to know why, not questioning in a bad manner, just would like to know what happens to the rest of the refrigerant, if you c an explain. Thank you

    • @MrSprintcat
      @MrSprintcat 10 หลายเดือนก่อน

      The 410 a is a blend . Needs to go in as a liquid. If you put it in as a gas it will screw up the whole blend .😮

  • @Jeff-Lawrence
    @Jeff-Lawrence 3 ปีที่แล้ว

    I’m might be missing something but this got me thinking...
    the flow is cut off at the compressor and if so how does the air get purged between the high side service valve through the evaporator to the compressor or the low side service valve to the compressor.
    Just wondering

    • @Oldthesis
      @Oldthesis 3 ปีที่แล้ว +1

      There is a complete circuit through the line-set (liquid line and vapor line) back to the outdoor unit, any air would be purged by pressurizing either side. Here, they show the liquid line pressurized first, which is typically the direction of refrigerant flow in the cooling mode.

  • @janibashamolla
    @janibashamolla 2 ปีที่แล้ว

    Thanks a lot sir 👍👍 you explains very good but too fast talking...

  • @glennhendricks4111
    @glennhendricks4111 3 ปีที่แล้ว

    Will someone help me understand how to nitrogen purge, test, and vacuum the Entire system....... inside unit, line set and( THE OUTDOOR UNIT ) of a mini-split with only one service port? Seenville 12,000 btu heat pump. The system is 6 yrs old, was given to me with no refrigerant in it. The owner let me have it for free. He said the only problem was leaking flares. He hired a cheap guy on craigslist to fix it.....well the guy supposedly lost the charge and never came back to fix it. Professionals wanted to charge him enough to get him to just buy a new one. I carefully removed it from his home. I have 2 other mini splits that I installed myself and I love them....I have all necessary tools and know how to use them....what I don't know is if the outdoor unit will allow my nitrogen to flow all the way through it. How do I know if the entire system loop is accessible through the one service valve? Does the EEV need opened up with a doughnut magnet? Is there some refrigerant trapped in the compressor that could be contaminated with air/moisture.....how do I make sure I have a clean, dry, and tight system in this situation? I wish I could just make new flares, hook up the lines, open both hex ports add nitrogen to the one service valve on the larger line, fill it to 200 psig and crack the flare nut on the small line a let it purge out, then seal the system and do a leak test. Is it that easy? does the entire system loop pressurize ....or is there going to be some point where the nitrogen bypasses the compressor or EEV?

  • @octavioussplevinski1409
    @octavioussplevinski1409 ปีที่แล้ว

    was the bro really brazing with normal, non tinted safety glasses....

  • @sangeetachauhan1807
    @sangeetachauhan1807 3 ปีที่แล้ว

    Will be more helpful if speak slowly

  • @mtz5582
    @mtz5582 ปีที่แล้ว

    Somehow disappointed with the contents from the Chanel I dearly treasure.I am a rookie and the information delivered was too technical and only useful for advanced engineers.