I tried to watch other people's videos on how to do a bending schedule, I did not understand them until I landed on this video. I now feel like I am an engineer. I am doing a bending schedule for my house and you simplified the process. Thank you very much
Simply fantastic and so easy to understand, Excellent presentation. The stirrups spacing near the columns should be 150 mm and in the middle 300 mm maximum. 500 mm throughout is too much
Nice explanation 👍 But for proper Bbs you have deducted bend And development length concept And stirrups length Please explain by considering all points so it will be economically Beacause at site it's no matter But by professional bbs and to save steel and wastage we should want to calculate proper cutting length But overall good explanation Keep it up 👍
Sorry Sir. But you have to add +1 while calculating the no of stirrups. Also you have to deduct all the bends while calculating the length of the rod. The formula for that deduction is *(no of bends X d)* where d is the dia of bar.
By seeing comment i can bet that everyone understand correctly....... Dought comes when u understand the things😜😜😜..... But 1 issue we cant provide 0.5m =1.64 ft spacing sir 🤪🤪🤪🤪🤪
My question is this type of reinforcement is so common okay but also there is another type is with crancked bar. In Turkey cracked is not very common anymore but I am wondering the situation in global? Is it using or forbidden?
Subscribe to my new Channel :)
th-cam.com/channels/FON1In_xIuPqWc_GGWawUQ.html
I tried to watch other people's videos on how to do a bending schedule, I did not understand them until I landed on this video. I now feel like I am an engineer. I am doing a bending schedule for my house and you simplified the process. Thank you very much
You are so welcome!
Hmm bro you can carry on
Simply fantastic and so easy to understand, Excellent presentation.
The stirrups spacing near the columns should be 150 mm and in the middle 300 mm maximum. 500 mm throughout is too much
Glad it was helpful!
10.608 x 4 =42.432........... sir ji☝️
Nice explanation 👍
But for proper Bbs you have deducted bend
And development length concept
And stirrups length
Please explain by considering all points so it will be economically
Beacause at site it's no matter
But by professional bbs and to save steel and wastage we should want to calculate proper cutting length
But overall good explanation
Keep it up 👍
Thank u sir lots of love
Always welcome
nice line 😁 bro..
hi sir, explanation good .....bottom beam total No. 42.432m not 53.5m and add +1 when adding stirrup
Thanks sir this video has helped me alot
Most welcome
Explanation is clear
Way better explanation compared to my professors 😅
Hi sir..
Can you help me what does 330 means in this detail?
2T12 125-330 B1
You didn't subtract bend which is 2 d, and why do some people use 12d for hook length instead of 9d or 10d
Nice explain sir Thank you.
You're most welcome
Sorry Sir. But you have to add +1 while calculating the no of stirrups. Also you have to deduct all the bends while calculating the length of the rod. The formula for that deduction is *(no of bends X d)* where d is the dia of bar.
Thanks, appreciated
No of bend x 2d is correct
@@selvarajmurugan9996
For 45° it is (x1)
For 90° it is (x2)
nice one. i like it, can you explain about the design of circular footing.
Bar bending schedule of column
thank you sir..
Welcome!
By seeing comment i can bet that everyone understand correctly....... Dought comes when u understand the things😜😜😜..... But 1 issue we cant provide 0.5m =1.64 ft spacing sir 🤪🤪🤪🤪🤪
hhhhhh..i also noted this point ..*******
Should the stirrups be closer at both ends of the beam?
Fantastic beam bar bending schedule # but the formula for hook ( development length for 135 dgree angle is 2d #
Its 3d bro
Awesome teach sir 🙏🙏🙏
Nice thanks to share
Thanks for watching
All bottom bars are 12 mm dia??
Tnx alot
🎉
Bro u have dint added bend length ......2*d
Hook lenght is 9d
Why too much space between stirups? Pls share formula?
Niceeeeeee. Sir
Normaly the number of stirups = length/ space +1..please clarify this
yes. you are correct
Yes, ur correct
Why we are taking hook length 12d
Yes
Specing no 500 mm mix 300 mm
And how is the distance between the buttons bar I mean the space between the four bars or how did we get four bars and the top bar two
Hi sir was interested
Why we are taking hook length 12d
Some books using 12d
Kindly can you advise is it not required here to deduct the length extended after bending in two ends of top and bottom bar?
I think beam clear cover is 20mm
Is 456 suggest that spacing between stirrups is max. 300 mm
Thisa is explanation according to American code
How we can used in excel sheet..please make a video
Hook length is 12d. From which code you hate got this value?
My question is this type of reinforcement is so common okay but also there is another type is with crancked bar. In Turkey cracked is not very common anymore but I am wondering the situation in global? Is it using or forbidden?
Its using in almost every code
Why does the button bar contains more bar than the top bar
Gd..
L = 6D AS PER M Chakraborty
Excel sheet melega kya
You are resting 400mm wide beam in 200 mm wide column. It dosent matter here. But try to avoid these things.
Beam detail droing and measument
the number of top bars should more compare to bottom bars and u didn't subtract the bend length
Wrong the stirrup will be 21
Calculate rwong
Can you explain in Telugu sir
10.608*4 is not 53.5
right bro
4x10.608 equals 53.5?
42.432 is the ryt answer
42.438 correct answer
For every 90° bend 2d will be minus
Yes ur the correct.
1d for 45° & 2d for 90°
its wrong
Pakistani aur indian BBS different method sy😑confusing
Hindi m batao bhai
10 m beam will fail when you provide such a minimum dimension clm