Agar earthing me current flow ho raha ho tab us condition me phase ka current zyada hoga neutral ke comparision me, to kya us time pe RCCB trip ho jayegi?
In video you tell that 5A current will flow in both phase and neutral but Neutral wire carry zero ampere current in single or three phase circuit. it carry current only when unbalanced load system
Sir mitexpower bettery vs okaya bettary ke bare mein baat do sir bahooot jaroori hai hamko 1mahine main Lena hai sir iske bare main ek ya do din main video banadijiye sir 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
डियर सर, मैंने 4000 watt का paragon portable गीज़र लिया है। जिसके साथ 18 amp 240V का थ्री पिन प्लग मिला है। मेरे घर में earthing नहीं है। क्या मैं company के 18A के प्लग के जगह पर Havells का shock safe 16A 30mA PRCD Plug Top यूज़ कर सकता हूँ? कृपया मेरे इस सवाल का जवाब दें मैं आपका बहुत आभारी रहूँगा।
Without connecting earthing to rccb it will start malfunctioning and will not protect you from electrical shock. so earthing must be done with rccb . It is necessary to connect earthing with rccb as per IEC guidelines.
मैंने अभी नया घर बनाया है और इलेक्ट्रीशियन से उस घर की वायरिंग भी करवा दी है इलेक्ट्रीशियन में अर्थ का तार डाल दिया है । दिक्कत यह आ रही है कि वह अर्थिंग के तार में टेस्टर से चेक करने पर फेस का करंट दिखाई देता है। दूसरा मैं अपने मेन लाइन से घर की में सप्लाई के लिए आरसीसीबी rccb लगाना चाहता हूं । मेरे मन में यह एक जिज्ञासा है कि यदि कोई हेवी लोड जैसे ड्रिल मशीन कटिंग मशीन इस तरीके का और कुछ मशीन चलाई जाए जो ज्यादा बिजली कंज्यूम करते हैं तथा जिन से लाइट में फ्लकचुएशन आता है लाइट अप और डाउन होती है । क्या इस कंडीशन में भी आरसीसीबी rccb trip हो सकती है ?
बहुत अच्छी जानकारी दी अपने ,आपका धन्यवाद।
Mujhey ye video bht achaaa laga
Thanks electrical dost group 🙏🏼🙏🏼🙏🏼
thanqqq bhai mein ye video kafi time se wait kar raha tha 🙏🙏
Bht aaLa sir , thank you from 🇵🇰
Thank you so much sir
Very nice knowledge sir
Awesome explanation 💝
sir ! interview mein puche jaane wale question se related video bnao please. 🙏
Very Helpful Video
Sir aap kaun sa styles pen use karte hai....aur vedio ke liye kaun sa software or app use karte hai .. reply pls
Achha hai sir thank you..🙏
Very nice sir
The best knowledge
kya ek single RCCB and MCb use kr skte home mein main supply ke paas. ya phir har room ya equipment mein alg lag se lgana hoga
Thanks 🙏🙏🙏🙏 sir
Zabardast bhai
Bhai mere pas earthing hai kiya me rccb lagaloo kiya agar earth leak hoga to rccb trip to nhi hogaa please reply
Nice video and thank
Very nice
Sir, CT knee point test kese karte h iss pe ek video banaa dijiye sir🙏🙏
Sir miter ki main wire pehle rccb me lago ya MCB me
पहले dp MCB मैं बाद मैं rccb मैं बाद मैं mcb मैं
Sir, please explain phasor diagram of 3 phase induction motor and its equivalent circuit
Sir.. सिंगल कामप्रेसर ग्लैंड और डबल कामप्रेस ग्लैंड का उपयोग बता दीजिए plz🙏🙏🙏
Can you get a rccb repairing video bcoz its cannot available in TH-cam
Maine L&T company ka 40amp ka aur 30 ml amp ka rcccb liya hai to uska connection uper se dena hai ya niche se please replay me
Excellent sir
Thanks
Very good 👍
Sir solar GHI AND GII KE Bare me video banaye.🙏🙏
Gret job sir g
This info is very helpful 👍
Beautifully explained
Hi sir. DB box me Rccb aur MCB aur ice later. Ko conation karne ka sahi tarika bataye na sir please please 🙏
Rccb ke saath singal pole mcb laga ya doubal pole lagana h
Sir 15 miliampere par trip hone wali rccb bhi aati hai kya
Rccb aur elcb same h ya alg.... Elcb ko meter ke pas lgana h ya isolator ke bad aur mcb se pehle.....
Kya yah Bina arthing ke kam karegi
Nice Learning
Saras
Sir RCCBO ki bare mea bi ekk video bonaiea.
Hi bro
Can single earth pit rod will work for two separate meters and two sepaearth wires ?
thank you sir ❤️
Nice video...
MCB board mei 63 dp ki need nhi hogi jb rccb lagaye us jagah?
Sir inverter per RCC bhi kam Karega
Yes
Kya mccb aur rcb saath main use kar sakte hai???
Sath me he use karte he
@@sunilkilledar4061 ok bro thnx
Bhai wireless charger kaise kaam karta hai?
Video banao please 🙏
Havells shock safe prcd plug bina earthing ke work karega ya nahi?
Nice information
Thanks sir ji
Agar earthing me current flow ho raha ho tab us condition me phase ka current zyada hoga neutral ke comparision me, to kya us time pe RCCB trip ho jayegi?
Hello bhai, rccb mein phase neutral ulta pulta hoo jaye (means phase k jaga neutral cable or neutral k jaya phase cable lagaye) toh rccb work karega yaa nahi
Sir mera ghar me rccb or mcb duno hai mere ko duno phase garm garam phase add kar sakte hai ya nahi
Mcb .or .Rccb .के शाथ .कैसे AC कनेक शन कीया जाता है .बाताइए .odisa sy . p.tandi
Sir daily vdo upload kijea na
Sir wo bhi detail main batayega 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
In video you tell that 5A current will flow in both phase and neutral but Neutral wire carry zero ampere current in single or three phase circuit. it carry current only when unbalanced load system
sir Home keley kon si type ki rccb use karna chahiye
Sir ji earthing cebale ko sabhi board socket me dalne ke bad aagar mcb box me earthing na joje to kya hoga
Mare Ghar main 32amp dp MCB ke sath kitne amp ka rccb lagana chahiye ?
Sir rccb lagane ke bad hi aaishuletr lagye kya or bad me MCB..
पहले इसोलीटर फिर rccb बाद मैं mcb
@@swapnilbhatapkhalebhatapkh9538 ok thanks 👍 sir
Sir mitexpower bettery vs okaya bettary ke bare mein baat do sir bahooot jaroori hai hamko 1mahine main Lena hai sir iske bare main ek ya do din main video banadijiye sir 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Kya MCCB single phase ki hi hoti hai?
Good
Sir plz make the video on capacitor bank and why it is necessary in ss
Sir apka electrical book milta hai ya nhi
Rccb electric shock protect hain kya?
Thank you sir
Sir g ghar main rccb phle lgana chiye ja mcb?
Only RCBO
@@silentkiller-tj9tm RCBO kya hota he ??
@@bhaveshpanchal8092 residual circuit breaker with overload...ghar m yeh sbse best hai Rccb mcb lganey ki jaroorat nhi pdegi
@@silentkiller-tj9tm गलत हैं भाई mcb जरुरी है
@@swapnilbhatapkhalebhatapkh9538 bhai rcbo jaroori h woh rccb ka bhi kaam kr lega
❤❤
क्या ये बिना अर्थिग के काम करेगी क्या
Barish m bijli kadakne s fan karab ho ja rha h bar bar swech bnd rehta h fir v to uske liye kya lgana chahiye mcb lgaye huye h
RCCB slipper pehne rhenge aur legega to Kam krega ki nii?
Can rccb used as circuit beaker
Ghar ka andar ground wirening pura karne ke baad paip se sab wire ko nikal sakte hai
Can I get a heart thanks
डियर सर,
मैंने 4000 watt का paragon portable गीज़र लिया है। जिसके साथ 18 amp 240V का थ्री पिन प्लग मिला है। मेरे घर में earthing नहीं है। क्या मैं company के 18A के प्लग के जगह पर Havells का shock safe 16A 30mA PRCD Plug Top यूज़ कर सकता हूँ?
कृपया मेरे इस सवाल का जवाब दें मैं आपका बहुत आभारी रहूँगा।
सर अगर अर्थिंग करी हुई है तो क्या rccb फिर भी लगाने की जरूरत है?
Earthing ka power kitna hona chahiye or Kaise check krrte hai ek video banao na bhai is topic pe.
1 bag bentonite powder
Without connecting earthing to rccb it will start malfunctioning and will not protect you from electrical shock. so earthing must be done with rccb . It is necessary to connect earthing with rccb as per IEC guidelines.
Uu
Sir please tell me RCCB lagane ka charge in Uttar Pradesh
Karti hai, RCCB neutral ke sath kaam karti, backflow current
फेस 2 फेस इस्टेप्लेजर में Rccb काम करेंगी की नही वीडियो बनाओ सर जी
❤
Nice
पूरे घर के सिर्फ 1 RRCB को सीधा इंसुलेटर या मैन स्विच के बाद लगाया जाता है या RRCB प्रत्येक कमरे में अलग अलग लगाई जाती है?
MCB Ke Baad Main Line Mai 1 Hi RCCB Lagana Hota Hai
Sir abb RCBO aa rhe hai
O mean RCCB WITH OVERLOAD
Pulse relay ko samjha sakte hain kya aap
Baarish me rccb trip karne ka solution..?
Inverter ke sath rccb kam Karega
Kya rccb tabhi kam karegi jab ham har ek point ka neutral aur face alag lete hai
Sir. 11000volte. Ki line ghar me a jati hai. Kaise bachaye.
Mene bhi RCCB lagai hai....
But vo lightning mai bar bar trip kyu ho jata hai bataye....
Nice sir 3phase rccb me neutral connect nhi kre to kya wo work kregi kya
Nahi kaam karega rccb without neutral
@@chetanpatil5305 tino phase ka current unblance ho to kya hoga ydi neutral connect ho
Sir mere dono said fes aaraha hai bahar se Maine kamplen kiya unhone kaha transfermar me gaud nahi hai isake liye kya karen
Sir aap ki sab video dekhte hai bahut accha lagta hai
Sir Three phase RCCB kaise kam krti hai.
मैंने अभी नया घर बनाया है और इलेक्ट्रीशियन से उस घर की वायरिंग भी करवा दी है इलेक्ट्रीशियन में अर्थ का तार डाल दिया है ।
दिक्कत यह आ रही है कि वह अर्थिंग के तार में टेस्टर से चेक करने पर फेस का करंट दिखाई देता है।
दूसरा मैं अपने मेन लाइन से घर की में सप्लाई के लिए आरसीसीबी rccb लगाना चाहता हूं ।
मेरे मन में यह एक जिज्ञासा है कि यदि कोई हेवी लोड जैसे ड्रिल मशीन कटिंग मशीन इस तरीके का और कुछ मशीन चलाई जाए जो ज्यादा बिजली कंज्यूम करते हैं तथा जिन से लाइट में फ्लकचुएशन आता है लाइट अप और डाउन होती है ।
क्या इस कंडीशन में भी आरसीसीबी rccb trip हो सकती है ?
Bhai pin kr de plz bahut meharbani hogi plz ❤🥺🥺❤
कहा पे सिंगल कामप्रेसर ग्लैंड का उपयोग कर और कहा पे डबल कामप्रेसर ग्लैंड का उपयोग कर 🙏🙏🙏🙏
Bhi earthing ke bina to kise ko b shock lg sakta h
Sir RCCB bina earth ka kam kargi
सर हमारे ट्रांसफॉर्मर पर बोल्ट होने पर घर के उपकरण जल जाते है इस के लिये कया लगाये