Top extra bars are to restrict negative bending moment. As there are no negative bending moment in slab we don't provide extra bar in slab. In case of slabs, there is punching moments at support we provide extra bars there.
hi, how to provide bent-up/ crank bar in two way continuous slab , i mean if the slab size is 40'x60' , there are many beams for support, my question is crank bar can be provided at only in end beams are cranked in every beam, if it is in every beam, rods length is in one length with overlapping or it may be cut sizes according to slab sizes
sir during construction bbi lana ek video please sir kya kya test hota hai... kese krate h pre construction list kya hoti during casting kya hota hai please sir🙏🙏🙏🙏🙏🙏
At point where there is junction of primary and secondary beam but there is no column ( only junction of P beam & S beam) and ...do we have to provide extra top over there or else only continous steel is provided??
Bilkul dete hain as per drawing. Iss video me full detail mein checking ni ki hai sir ne. I have worked as an assistant Qc in Pakistan. There is also one thing missing in the video. Apne dekha hoga start walay beam me col ki 1 side py 3 extra thae aur dosre end py 4 extra this is because 2 different beams hain aur jahan per cols k sath 2 beams ayein tou jis ka extra bars ziada hote hain usy hum L/3 per lete haim iss liye dosre end per 3 ki jagah 4 extra liye bars.
what is to be done when the length of development length is still left even after providing 'L'..? should we insert the remaining part into the column or bent it towards beam..?
I have learned on site that for those cases, we decrease the total length of column below it. Like for a 10’ column, we only cast 9’ column to accommodate the corresponding development length of beam that will be inserted in it.
🟢 𝐅𝐨𝐫 𝐨𝐟𝐟𝐥𝐢𝐧𝐞 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠/ 𝐨𝐧𝐥𝐢𝐧𝐞 𝐥𝐢𝐯𝐞 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐨𝐫 𝐚𝐧𝐲 𝐚𝐬𝐬𝐢𝐬𝐭𝐚𝐧𝐜𝐞 𝐲𝐨𝐮 𝐦𝐚𝐲 𝒄𝒂𝒍𝒍 𝒐𝒓 𝑾𝒉𝒂𝒕𝒔𝑨𝒑𝒑 𝒂𝒕 +𝟵𝟭𝟵𝟳𝟭𝟭𝟭𝟱𝟱𝟱𝟴𝟱
🔴𝐅𝐨𝐫 𝗥𝗲𝗰𝗼𝗿𝗱𝗲𝗱 𝐬𝐞𝐬𝐬𝐢𝐨𝐧
𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐑𝐞𝐢𝐧𝐟𝐨𝐫𝐜𝐞 : 𝐂𝐢𝐯𝐢𝐥 𝐄𝐧𝐠𝐢𝐧𝐞𝐞𝐫𝐬 𝐥𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐚𝐩𝐩.
👉𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐚𝐩𝐩 𝐥𝐢𝐧𝐤 : bit.ly/425ebrk
👉𝐖𝐞𝐛/𝐏𝐂/𝐋𝐚𝐩𝐭𝐨𝐩 𝐋𝐢𝐧𝐤: web.reinforceqst.com/
👉𝐌𝐲 𝐢𝐧𝐬𝐭𝐢𝐭𝐮𝐭𝐞 𝐚𝐩𝐩 𝐟𝐨𝐫 𝐈𝐎𝐒 𝐥𝐢𝐧𝐤: apple.co/3HFwBqo
Org code : avywj
📧 Email : reinforceqst@gmail.com
🌐 Website : www.reinforceqst.com
Is roof me crank bar que nahin diya gaya?
Thank you sir.Detail me samjhane k liye.
Sahi samjhaya Bhai...aap samjhao ge to aam aadmi bhi engeneer samjhe ga.👍
Very very Good, Explained with live construction that is very important to get Idea.
गर्दा kr diya सर जी
Bahut acha samajh aya ❤
Thank u sir for sharing valuable information.
Thank you very much sir.
good video sir
Sir very nice video one more I am remember that
Nice, what happens if the extra bars are different on either side of intermediate columns.
Sir lapping zone ki video m btaya gya tha ki top m lapping centre pr dete hj ,ends pr nhi dete.shi kya h sir
Very good knowledge
Good explanation sir
One question.
Why crank bars and extra bars are not provided in the slab ?
Top extra bars are to restrict negative bending moment. As there are no negative bending moment in slab we don't provide extra bar in slab. In case of slabs, there is punching moments at support we provide extra bars there.
Good 👍
Thanks Sir.
thannks great explanation .
hi, how to provide bent-up/ crank bar in two way continuous slab , i mean if the slab size is 40'x60' , there are many beams for support, my question is crank bar can be provided at only in end beams are cranked in every beam, if it is in every beam, rods length is in one length with overlapping or it may be cut sizes according to slab sizes
sir during construction bbi lana ek video please sir kya kya test hota hai... kese krate h pre construction list kya hoti during casting kya hota hai please sir🙏🙏🙏🙏🙏🙏
good 🙏
Nice
Good sir
Tqq sir
At point where there is junction of primary and secondary beam but there is no column ( only junction of P beam & S beam) and ...do we have to provide extra top over there or else only continous steel is provided??
Good question, but as there is no column no shear force comes. So not required extra bars where P and S beams junction.
Please make a video on bottom reinforcement.
Why have you not hooked stirrups in 135 degree? None stirrups are visible to be bent at 135 degree with 10* dia hook or 75mm( which ever is greater)
Slab reinforcement, main and secondary bars are provided as mesh, why not provided crank bars or shear bars.
Sir primary beam Anchroge coloum development length coloum outer me hona chahiye but coloum ka center me provide kiya gaya hi videos me
Is video banane k tym pe abhi steel arrangement fixing fully nhi huyi thi
Sir
Secondary beam me
Top Extra bar dete hai ki nhi
Agr dete h kitna ?
Bilkul dete hain as per drawing.
Iss video me full detail mein checking ni ki hai sir ne.
I have worked as an assistant Qc in Pakistan.
There is also one thing missing in the video.
Apne dekha hoga start walay beam me col ki 1 side py 3 extra thae aur dosre end py 4 extra this is because 2 different beams hain aur jahan per cols k sath 2 beams ayein tou jis ka extra bars ziada hote hain usy hum L/3 per lete haim iss liye dosre end per 3 ki jagah 4 extra liye bars.
Thanks sir
Sir through out steel ja Raha wo column ki steel under Hona Chahiye
what is to be done when the length of development length is still left even after providing 'L'..?
should we insert the remaining part into the column or bent it towards beam..?
I have learned on site that for those cases, we decrease the total length of column below it.
Like for a 10’ column, we only cast 9’ column to accommodate the corresponding development length of beam that will be inserted in it.
Sir extra bar sirf top per hi daalte hai ki bottom me v
Btm mai v
Are Bhai sab ek bat btao ye Jo middle me column aarhe h ....inke liye extra steel cut krenge to l/4 k liye cutting length kaha se kaha tk lenge
There are lots of videos we made regarding this check our full content properly!!
Sir ring ka hook galt hai 135 digri me baniye
Sir please send this drawing for better understanding
👌👌👌👍👍👍sir
Sir ring ki band 35' nahi hai
Secondary Bheem ka details nahin bataya
Slab ka bato extra baar
Jo concept smghne k liye mne video dekha uska answer to Mila hi nahi yr😂
50 se jyda video hai playlist check krein humara
43o
s
Not useful
Aaapke slab ka bent-up kaha hai😁😁