छत में कितने mm का सरिया इस्तेमाल करना है | slab steel thickness | minimum dia of steel for slab

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ก.พ. 2023
  • छत मे कितने सूत का सरिया बांधे | tmt bars for slab | minimum steel thickness for slab | slab reinforcement details | slab beam reinforcement details
    Join our 👇
    Telegram Group:- t.me/TecCivil
    Instagram page:- tec.civil22?igs...
    Facebook page:- profile.php?...
    Contact Details:-
    1. for Sponsorship and Business only
    Email:- tec.civil22@gmail.com
    Ph:- +91- 8234851478 (Only WhatsApp)
    Delhi,
    My Second Channel:-
    Techno Riq:- (For House Plans, Construction Videos, New tech & Tricks in Civil Engineering)
    / @mustwatchbytarique
    Top Most Video Playlist:-
    1. Plumbing Work:- • Plumbing Work
    2. Wood Work :- • Wood Work
    3. False Ceiling Work:- • False Ceiling Work
    4. House Construction Cost:- • House Construction Cost
    5. Steel checklist:- • Steel checking
    6. Checklist of Construction Material:- • Checklist of construct...
    7. House Construction Basic:- • House Construction Basic
    8. Construction Mistakes:- • Construction Mistakes
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - tec.civil22@gmail.com
    ✔Facebook Page: / civil-engine​. .
    ✔Instagram:
    ✔ Telegram Group:- t.me/TecCivil
    Note - This video is for educational purpose only. Copyright Disclaimer Under Section 107 of the Copyright Act 1976 , allowance is made for " fair use" for purposes such as Criticism , Comment , News Reporting ,Teaching , Scholarship & Research. Fair use is a use permitted by copyright statute that might otherwise be infringing.
    Non-profit , educational or personal use tips the balance in favor of fair
    crank bar, bent up bar in slab, bentup bar cutting length, crank bar kaise dena hai, minimum dia of steel for slab, chhat ke liye sariya ki motayi kitni rakhe, minimum dia of steel for slab,

ความคิดเห็น • 59

  • @user-jq8my2yd6g
    @user-jq8my2yd6g 3 หลายเดือนก่อน +1

    Very informative video..... Thank you very much....

  • @Rajvlogs4047
    @Rajvlogs4047 ปีที่แล้ว +1

    Good information jnab...👍👍...ma b main bar 10 mm or distribution bar 8 mm da rha hu..

  • @deveshdikshit90
    @deveshdikshit90 ปีที่แล้ว +2

    Sir 2500sq ft ka commercial building main slab main kitna mm ka Sariya use kare.G +3 floor construction main plz .

  • @pradiporaon3319
    @pradiporaon3319 ปีที่แล้ว

    Good information sir

  • @DheerajPal335
    @DheerajPal335 ปีที่แล้ว

    Residential House, Long span 16 fit shorter span 12 fit slab me kaun si baar use karen?

  • @smhentertainmentcricbuzz7447
    @smhentertainmentcricbuzz7447 ปีที่แล้ว

    Sir mera area 2000 sf he aur hall size 20*25 he usme konsa saria use kru

  • @raghunathbodke5718
    @raghunathbodke5718 7 หลายเดือนก่อน

    Nice information

  • @ratan6924
    @ratan6924 7 หลายเดือนก่อน

    If in a residential building we want to give 12 mm main bar and 10 mm distribution bar where pillar to pillar distance is only 12 ft. Then any problem. And also in pillar we used 8 bar of 16 mm for 4 storey building in ,15*40 plot size.

  • @rajusinghpatel9614
    @rajusinghpatel9614 ปีที่แล้ว

    Thnx

  • @mohammediqbal1842
    @mohammediqbal1842 ปีที่แล้ว

    Thankyou bro

  • @mandeepchoudhary961
    @mandeepchoudhary961 ปีที่แล้ว

    Slab me distribution bar 12 mm ka steel de skte hai kya???

  • @AnamuGouda-dm3jc
    @AnamuGouda-dm3jc 11 หลายเดือนก่อน

    Thaynkui

  • @zonoobtea4472
    @zonoobtea4472 ปีที่แล้ว

    Ek rod ka fasila kitni hana chahiye

  • @jyotisurati9124
    @jyotisurati9124 2 หลายเดือนก่อน

    12*10 ke Span slab me 10mm and 6mm Ka steel dal sakte hai? Kya 6mm Ka steel gov ne ban kiya hai?

  • @user-nk9yb9hc8o
    @user-nk9yb9hc8o 15 วันที่ผ่านมา

    Hello sir.... 15*15 hall me 9"*15" column me 4 baar 16mm 4 baar 12mm diya h or beam me 3 baar 16 mm at bottom and 2 baar 16 mm top and 2 xtra at top and 12 mm... And center me 16 mm ke 4 pc se hidden beam diya h ye safe h kya. G+ 2 ke liye. 🙏 plz reply

  • @udaychandan2200
    @udaychandan2200 6 หลายเดือนก่อน

    Dono bar 8mm liyeto chalegakalya

  • @RahulSingh-gd3od
    @RahulSingh-gd3od 6 หลายเดือนก่อน

    Sir 7.5 ki 30 steel kitna la gya

  • @sanatsejpada4127
    @sanatsejpada4127 4 หลายเดือนก่อน

    10 or 8mm ka saria 5"c/c...koi dikat hoga

  • @anmolvdubey2549
    @anmolvdubey2549 10 หลายเดือนก่อน

    Slab kitne inch ka karen sir

  • @Ride626
    @Ride626 5 หลายเดือนก่อน

    Crank ke paas binder niche se aana chahiye

  • @prakashsondarwa5350
    @prakashsondarwa5350 5 หลายเดือนก่อน

    video short m banaye sir

  • @mnarah-zy2bx
    @mnarah-zy2bx 5 หลายเดือนก่อน

    Only 8mm se hogi?sir

  • @magilalbhil546
    @magilalbhil546 10 หลายเดือนก่อน +1

    Bhai aapne. Mode pe jo sariya. Ooper lagaya hai. Bo. Niche ki taraf lagata hai

  • @rohitdhillon2374
    @rohitdhillon2374 ปีที่แล้ว +2

    Sir mera 42 ×100 ka lanter tha,jisme 20 rooms h,room size 9*12 hai,piller hai 18*12 pe,ek saal lanter daale huwa hai,6 room Mai crack aagaye,niche ke side,upper do room pe hai crack,usme Pani aata hai,steel bar lanter me 10mm,or 8mm lagaee thi,sir plzzzz soln

  • @paragg007
    @paragg007 ปีที่แล้ว

    slab ki beam pahale banana accha hota hai ya video mein dilhaye jaise beam with slab sath mein banana best rahata hai?

  • @Gamingwithshubham284
    @Gamingwithshubham284 21 วันที่ผ่านมา

    100 mm ka sariya istemaal kr sakte hai kyacht mai 🤔

  • @stanzinkhar405
    @stanzinkhar405 ปีที่แล้ว +4

    I have built an government building with only 8 mm bar in slab main and distribution both , it was recommended by the the government department . But the design was old style , there was no cranked bar provided but at l/4 from beam there was double mesh every where .

  • @civilenggdharmenderyadav209
    @civilenggdharmenderyadav209 ปีที่แล้ว

    ek video slab ka sariya kse bandte hai is topic bnaye

    • @TecCivilofficial
      @TecCivilofficial  ปีที่แล้ว

      Ok noted

    • @civilenggdharmenderyadav209
      @civilenggdharmenderyadav209 ปีที่แล้ว

      @@TecCivilofficial sir me kafi jagh dekha h ki columm casting or brick work krke slab casting krdete hai beam nhi dete hai toh kya ye load bearing structure h ya frame strture.. or beam na dene se kya fayda or nuksaan is topic pe video bnaye pls

  • @mikkasandhu1316
    @mikkasandhu1316 ปีที่แล้ว +2

    Agar kisi ne ghr mein get together rakhliya to? 🤣🤣

  • @mskaushikkaushik5856
    @mskaushikkaushik5856 ปีที่แล้ว +3

    Bhai sahab aapne ache se bataya par .aap camera 📸 rok ke Jo batana h wo batate to ache se samjh aa jata sab ko .aapka apni hi bole ja rahe ho camera chal Raha h kabhi edhar kabhi udhar .samjh na aa raha ache se kya samjhana chahte ho .jo bol rahe ho wahi camera rok ke ache se samjhao to koi Kami hi nai hoti

  • @mdanjarahmad5792
    @mdanjarahmad5792 ปีที่แล้ว

    Sir mera avi ek room bn rha hai..
    12 *11 ka (4column 12mm ka diye hai)
    Toh Usme kitna mm ka rod use krege chhat pe....??
    Nxt week casting hai
    Plz reply sir.
    Aur beam sirf bich me de rha hai mistry jhula beam.
    Wallbeam jaruri hai kya sir charo wall pe..??
    Budget jda nhi hai aur (G,G+1) tk hi bnana hai

    • @TecCivilofficial
      @TecCivilofficial  ปีที่แล้ว

      Beam to dena chahiye Kam se kam 9x9 inch ka usme 12mm ka 4 steel
      Or chhat me 10mm ka use kare

    • @slamansari91
      @slamansari91 4 หลายเดือนก่อน

      12 mm ke steel me kitna floor le ja sakte

  • @anthonypro9056
    @anthonypro9056 6 หลายเดือนก่อน

    Cover block nahi dene se kia problem hoga?

    • @user-km9sk9nd7k
      @user-km9sk9nd7k 4 หลายเดือนก่อน

      Bro salb ke niche aapka sariya dikhne lagega ok

    • @user-km9sk9nd7k
      @user-km9sk9nd7k 4 หลายเดือนก่อน

      Jaruri hai

  • @manbirchaudhary6921
    @manbirchaudhary6921 ปีที่แล้ว

    Sir 8mm ka sariya main or distributaion bar donome 5"/5" me dalahe or xat ki motai 6" he bim colam room k charo taraf he or 120sq fit ki room size he koi dikkat to nahi hogi?

    • @BAGWANIWITHGAURAV
      @BAGWANIWITHGAURAV ปีที่แล้ว

      Use 10mm main bar 8mm distribution bar plus centre to centre duri 7 inch best rahega क्रैंक जरूर दीजिएगा दो साइड

  • @nitishkumar-xf5ms
    @nitishkumar-xf5ms ปีที่แล้ว

    Sir chat me 10 mm or 8 mm sariya de sakte he room 10×12

  • @djmahendrabesragarmaramurk8331
    @djmahendrabesragarmaramurk8331 7 หลายเดือนก่อน +2

    Steel galat Bandha hai Bro

  • @nirmalchaudhari5397
    @nirmalchaudhari5397 7 หลายเดือนก่อน

    Sir main bar or distribution bar dono 10dia hoga to chalega na

  • @yogitamadhu488
    @yogitamadhu488 ปีที่แล้ว +2

    छत डालते समय पूरा 10 mm का सरिया दे सकते है या नही

  • @nirmalchaudhari5397
    @nirmalchaudhari5397 7 หลายเดือนก่อน

    Sir kya slab me primary steel 60% or secondary 40% Rakhe to chalega na

    • @TecCivilofficial
      @TecCivilofficial  7 หลายเดือนก่อน

      Secondary steel bhi achhi quality ka ho, IsI mark, Fe 550 grade

    • @nirmalchaudhari5397
      @nirmalchaudhari5397 7 หลายเดือนก่อน

      @@TecCivilofficial secondary steel Acchi grade ka 550d pura Ghar me use kar sakte hai kya ? G+1 house me

    • @nirmalchaudhari5397
      @nirmalchaudhari5397 7 หลายเดือนก่อน

      Koi dikkat to nahi aayegi na sir ?
      Me aaja steel ka order karne wala hu soch Raha hu konsa steel lu

    • @TecCivilofficial
      @TecCivilofficial  7 หลายเดือนก่อน +1

      @@nirmalchaudhari5397 ha bilkul kar sakte hai, Kay 2 lelo aap, kamdhenu, jindal, shyam,

    • @nirmalchaudhari5397
      @nirmalchaudhari5397 7 หลายเดือนก่อน

      @@TecCivilofficial hamare area me polaad ka milta hai sir

  • @dhananjaykevlog8700
    @dhananjaykevlog8700 6 หลายเดือนก่อน

    Is video me sariya Sahi nahi bandhaGaya Hai crank ke upar nahi hona chahiye