Configuring Danfoss VLT AutomationDrive FC 360 for CRANE (LONG TRAVEL) || DIGICON AUTOMATION

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ส.ค. 2024
  • Configuring Danfoss VLT AutomationDrive FC 360 for CRANE (LONG TRAVEL) Application || DIGICON AUTOMATION
    Parameters :
    1-01 MOTOR CONTROL PRINCIPAL [0] U/f
    1-20 MOTOR kW ONE VALUE HIGHER THEN MOTOR kW
    1-22 MOTOR VOLTAGE AS PER MOTOR NAME PLATE
    1-23 MOTOR FREQUENCY AS PER MOTOR NAME PLATE
    1-24 MOTOR CURRENT AS PER MOTOR NAME PLATE
    1-25 MOTOR RPM AS PER MOTOR NAME PLATE
    1-60 LOW SPEED LOAD COMPENSATION 180%
    2-10 BRAKE FUNCTION [1] RESISTOR BRAKE
    2-11 BRAKE RESISTOR (ohm) *
    2-12 BRAKE POWER LIMIT (kW) *
    2-20 RELEASE BRAKE CURRENT 30% OF MOTOR CURRENT
    2-22 ACTIVATE BRAKE SPEED [Hz] 10 Hz
    3-10 [0] MAIN SPEED REFERENCE 100%
    3-15 REFERENCE RESOURCE 1 0
    3-16 REFERENCE RESOURCE 2 0
    3-17 REFERENCE RESOURCE 3 0
    3-41 ACCELERATION TIME *
    3-42 DECELERATION TIME *
    4-14 MOTOR SPEED HIGH LIMIT 50 Hz
    4-16 TORQUE LIMIT MOTOR MODE MAXIMUM
    5-10 TERMINAL 18 DIGITAL INPUT [8] START
    5-11 TERMINAL 19 DIGITAL INPUT [11] START REVERSE
    5-12 TERMINAL 27 DIGITAL INPUT NO OPERATION
    5-13 TERMINAL 29 DIGITAL INPUT NO OPERATION
    5-14 TERMINAL 32 DIGITAL INPUT NO OPERATION
    5-15 TERMINAL 33 DIGITAL INPUT NO OPERATION
    5-16 TERMINAL 31 DIGITAL INPUT NO OPERATION
    5-40 FUNCTION RELAY [32] MECHANICAL BRAKE CTRL
    * As per product value or as per application

ความคิดเห็น • 12

  • @ajaypatel47
    @ajaypatel47 3 ปีที่แล้ว

    Thanks sir

  • @michaelnasief9245
    @michaelnasief9245 ปีที่แล้ว

    Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help

  • @alwayssmile6928
    @alwayssmile6928 4 ปีที่แล้ว

    Sir only pressure transmitter ke through danfoss drive ki speed kaise control Kare aur run command testing KE liye direct hoga please video banaye (( ye system water line KE liye hai tho Kya esa ho sakta ki water ka pressure jaise jaise up hoga vfd ka speed down hoga aur water ka pressure down hoga vfd pressure up hoga

  • @faturrohman1885
    @faturrohman1885 3 ปีที่แล้ว

    Can used for FC208?

  • @gurindersingh1606
    @gurindersingh1606 4 ปีที่แล้ว

    sir VLT drive with encoder and without encode kasay run karay

  • @pramodkumarmandal7940
    @pramodkumarmandal7940 4 ปีที่แล้ว

    sir, agar menu do bar daba ne par Om1 na aakar (pw)password aa jai to kiya ka re yadi pw pata na ho to

  • @rathodaravind2935
    @rathodaravind2935 4 ปีที่แล้ว

    sir LT ko muje 25%50%75%100%me speed ko kese control karne ka parameter kon sa he.olz reply

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 ปีที่แล้ว

      Use parameter no. 3-10 Preset reference,
      [0] 25%
      [1] 50%
      [2] 75%
      [3] 100%

    • @rathodaravind2935
      @rathodaravind2935 4 ปีที่แล้ว

      Thank you sir

    • @rathodaravind2935
      @rathodaravind2935 4 ปีที่แล้ว

      sir crane me resistance kyo lagana padta he plz rply sir

  • @reegansavio
    @reegansavio 4 ปีที่แล้ว

    Error 85 how to solve