Troubleshooting a Furnace Inducer Motor (The 4 Most Common Problems in 2021)

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024

ความคิดเห็น • 126

  • @foxfamilyheatingandaircond4696
    @foxfamilyheatingandaircond4696  3 ปีที่แล้ว +11

    Hey guys, today I wanted to expand on our recent gas furnace troubleshooting series. “The Easy Guide to Diagnosing a Bad Furnace Inducer Motor” will fill you in on what the inducer motor does, why it’s important, the most common of ways I’ve found inducer motors fail, and how to let the customer know what you’ve found.

    • @jeffthurman7127
      @jeffthurman7127 4 หลายเดือนก่อน

      Putting off a code 113

  • @Mike-fp5rc
    @Mike-fp5rc 2 ปีที่แล้ว +1

    This is not an instructional video, but more a training video for this company's techs.

  • @whaleoilbeefhooked3892
    @whaleoilbeefhooked3892 2 ปีที่แล้ว +1

    Just as stated in your video, most inducer fans are not serviceable so there's no point wasting my time troubleshooting a dead horse. Saved me a ton of time. In mine I just replaced the fan and all is good. TY

    • @nepilefulufhelo9072
      @nepilefulufhelo9072 5 หลายเดือนก่อน

      Mine is making noise when I start an engine, but after some time it will stop, is it a sign that I must take it for repair

  • @smoldt88
    @smoldt88 2 ปีที่แล้ว +1

    thanks for the video! diesel mechanic here. now i know a bit more about HVAC

  • @adamspears3819
    @adamspears3819 3 ปีที่แล้ว +6

    Your videos are gold!
    Thank you & keep uploading more videos, please.
    Yes! I frequently find myself informing my customer that this repair "might happen in multiple stages" meaning that I cannot guarantee that there will not be other expenses, until after I install such-&-such part so that I can get the system up & running to evaluate it's over-all performance.
    If I have noticed that the customer is religious, I tell them to "pray that the bleeding stops with just the need for that part repair" that I just quoted them.
    & yes, there are people out there that tell me that they understand this, but after informing them that new information has come to light, & today's service repair requires additional costs....some people still come unglued.
    BUT, that's when I nicely remind them that THAT could be the case after getting the system up & running; that additional costs are needed for a repair that entails multiple stages.
    It's not fixed, unless you have resolved ALL issues....& that is what every customer expects from me as a tech. So I remind them of that.
    I have yet to have a customer say, "Don't fix all the issues. I don't want it fixed. I'll just pay you to fix one issue."
    A customer will be upset, but in the end, they really want a thorough tech that finds & resolves ALL issues, so that they are not paying for several diagnostics.
    I also point this out to customer's & explain to them by only paying 1 diagnostic, they are saving potentially hundreds of dollars.
    "Which is cheaper?....several diagnostics?.....or just one?"
    "I am saving you grief & headache by finding EVERY issue on today's service call."
    (You should be thanking me, rather than ranting on me!)
    Every tech out there knows what I'm talking about.

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  3 ปีที่แล้ว +1

      Awesome stuff Adam. Yes this is what we face out there. It can be very uncomfortable sometimes for them, but as we say a lot here. It is what is. 🤷

    • @adamspears3819
      @adamspears3819 3 ปีที่แล้ว +1

      @@foxfamilyheatingandaircond4696 You got a fan in Corpus Christi, Texas. Thanks for the videos, I watch them & they help me as a tech.

  • @shawnolson4522
    @shawnolson4522 2 ปีที่แล้ว +1

    Awesome content right there. I work for a school that has old furnaces and mud dobbers built a nest in the inducer. I have zero Hvac experience and your video just shined a bright light o the world of furnaces for me. Thanks.

  • @timothygingras6939
    @timothygingras6939 6 หลายเดือนก่อน

    Good job, Fox and family great communication skills. You will have a customer for life.

  • @MegawattKS
    @MegawattKS ปีที่แล้ว +1

    Beautifully done video. I loved both the technical information, photos of parts and heat exchanger, and the advice on customer interaction. Well done. Thanks!

  • @davewilson6880
    @davewilson6880 ปีที่แล้ว

    Your videos were a great help as our temps hit single digits coming this week any my furnace quit on a Saturday. You helped me narrow it down to my pressure inducer switch. A few taps and the switch started working again. Now I just need to find a new one on Monday. Thanks.

  • @cadavercasillas3901
    @cadavercasillas3901 3 ปีที่แล้ว +8

    GRACIAS 🙏 for the video!!! god bless you with more Knowledge !!! Thank you for sharing

    • @88BuckMeister
      @88BuckMeister ปีที่แล้ว

      Cadaver...is your dame really Cadaver? What does that translate to in Español? Because in Ingles, a cadaver is a dead body

  • @ian_snyder
    @ian_snyder ปีที่แล้ว

    This is awesome! I've got an old furnace and this is exactly the info I needed to troubleshoot what is going on. Thanks!!

  • @notoriouskelly
    @notoriouskelly 7 หลายเดือนก่อน

    Ecellent video with rapid, concise and understandable explanations! 👍

  • @josecastro7581
    @josecastro7581 7 หลายเดือนก่อน

    Gracias my friend already buy inducer motor for my furnace I try to fix by myself

  • @timcat1004
    @timcat1004 ปีที่แล้ว +6

    Wrong right out of the gate. The main board will check that the pressure switch is in the correct position before engaging the inducer motor. Then it will check for the proper change in the switch position after to prove that both the inducer and switch are functioning together. Some boards will check the switch after one cycle and then lockout if it thinks it's stuck or by-passed. This prevents a by-pass or tampering being left in a permanent state.

    • @jimbarron8688
      @jimbarron8688 9 หลายเดือนก่อน +1

      A lot of people fail to mention the self check of the pressure switch circuit as a step in the sequence. Also they fail to recognize that the heat safety circuit, limits, is under constant supervision. Lastly he mentions that the vent motor be checked for the correct voltage but neglects to mention that a good neutral is also essential.

    • @metalrooves3651
      @metalrooves3651 8 หลายเดือนก่อน +1

      these inducre motors are any easy fix and 60-175 ..for the motor only.with labor,ITS A ROBBERY..EASY DIY JOB!

    • @vero0992
      @vero0992 8 หลายเดือนก่อน

      So if the inducer motor is never kicking on, it could still be an issue with the pressure switch right? My manual indictes an issue with the pressure switch or venter. Hoping the pressure switch is bad or has some clogging nearby, but got a little confused since the inducer motor won't kick on at all. 25+ year old well-maintained Goodman.

  • @humancentered3447
    @humancentered3447 3 ปีที่แล้ว +8

    Think of it like this, would the manufacturer send out a furnace that breaks less than a year into service then have a garbage warranty that barely covers the part but none of the service which is specifically required by the warranty in order to qualify for the part? Yes. How about not making parts that you throw away and making parts that can actually be serviced.

  • @dureace
    @dureace ปีที่แล้ว +1

    How to know if their is no power getting to the furnace!! Great videos.

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  ปีที่แล้ว +1

      You would need a voltage meter to be able to tell. Thanks!

    • @dureace
      @dureace ปีที่แล้ว

      @@foxfamilyheatingandaircond4696 I will give it a try

  • @tomference4618
    @tomference4618 ปีที่แล้ว +1

    ..very good, prudent in steps!

  • @bertrand100ful
    @bertrand100ful ปีที่แล้ว

    Interesting Video; Thanks a lot from France!

  • @JA-vy1gp
    @JA-vy1gp ปีที่แล้ว +1

    Great video thank you for sharing your knowledge

  • @Digital_Photog1995
    @Digital_Photog1995 ปีที่แล้ว +1

    Thank you for this information! My American standard Gold (two stage) furnace (installed 5 years ago)has a Inducer motor making loud noises. The
    Repair (installer) has notified me the inducer motor is back ordered and unavailable for only god knows when. He will notify me when the item ships and will schedule the repair when he has the item. So far it’s taken a few months (so far). Waiting patiently but this is winter in New Hampshire and it has been very cold. Hoping the motor lasts through the rest of the winter! Any comments or suggestions would be appreciated. Thanks

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  ปีที่แล้ว

      Oh man. that's rough. You guys have had some cold temps this summer. What about Trane? Have you tried them for the part?

  • @Rob-pg7rb
    @Rob-pg7rb 5 หลายเดือนก่อน

    I replaced my inducer motor and blower wheel because of bearing noise. Got them separately on Amazon. Now I got a lot of orange flame. Flame looks like crap. It was nice and blue before. Also seems like the flames are not being pulled/stretch enough inside the exchanger because the flames are not a narrow as before.
    Maybe didn't adjust the fan blade on the motor shaft far enough out?
    Maybe the new cheap Amazon blower wheel sucks?
    I got a nanometer, but haven't checked the vacuum on the inducer yet. Not sure if the manual has a spec or not.

  • @zack9912000
    @zack9912000 3 ปีที่แล้ว +2

    Easy to tell when they go bad, pressure switches are easy to troubleshoot. Volt meter seeing 24v power travel through the switch and a manometer to verfiy its getting enough vacuum to close. Easy to test contacts and the diaphragm.
    Basic knowledge of sequence of operation is a must. I always include a new pressure switch with any ventor motor replacment. Been burned only doing a ventor motor and then find the ps is bad or going bad.

  • @amurad4835
    @amurad4835 3 ปีที่แล้ว

    Thank you for the great advice will be ordering one and installing it, great company name

  • @tipsy09
    @tipsy09 2 ปีที่แล้ว +1

    nice video. for me it's the black wheel that often makes a scratching noise when the furnace comes on for the first 3 minutes and it wont' scratch the entire 3 minutes, just intermittently. after that, there's no noise.

    • @aitf99
      @aitf99 2 ปีที่แล้ว

      Were a throw away society....
      That needs to change...

  • @johnjohnson6838
    @johnjohnson6838 3 ปีที่แล้ว

    Fantastic explanation

  • @ejea8298
    @ejea8298 4 หลายเดือนก่อน

    My inducer motor is making a vibrating noise upon startup. When I press firmly on the motor then the noise goes away. Is there a quick fix for that? Maybe some love taps on the motor?!

  • @Dub-ry4cs
    @Dub-ry4cs 9 หลายเดือนก่อน

    I’ve tested with my multimeter and have 120 volts at the harness that plugs into the motor housing, but it’s not running. What would cause my inducer not to come on? When I first turn the furnace power on, I can hear a slight humming, but sounds like the motor isn’t running. This is a Bryant furnace. Also got a status code of 4 fast flashes and 2 slow flashes from the board, when the dip switch was set to status code retrieval, which as far as I can tell points to the inducer.

  • @RC-Heli835
    @RC-Heli835 2 ปีที่แล้ว

    I have an old 1980ish Rudd furnace hat doesn't have a circuit board.
    It only has relays. One 24V transformer for the thermostat circuit, one 110 volt relay for the Inducer motor and one relay for the blower motor.
    My inducer motor has quit getting 110 V from the relay.
    My blower comes on immediately the instant that the thermostat is set to call for heat.
    It does shut off once the thermostat is satisfied but will run indefinitely if the inducer motor has shut the gas off to the furnace before the thermostat is satisfied.

  • @jacobuszwanenburg1629
    @jacobuszwanenburg1629 10 หลายเดือนก่อน

    Oh no , my furnace quit !! It’s -15C
    What to do as this modern unit I have no idea.
    I see the videos.
    I make some basic checks. It hums but no fan turning.
    Maybe it’s stuck ?
    I assist the fan motor and it spins after lightly breaking free of something holding it ?
    I power the unit and it turns on inducer motor and I hear it rubbing the housing . I only grabbed the housing with light pressure and the u it became as quiet as a mouse again . Why did this happen to the unit ? It’s 5 years old . How did gravity make that housing rub ? It’s inside the furnace housing covered and very little dust after 5 years.
    Any way it’s all working fine again thank goodness. I gave myself a lesson on modern systems , bonus. Before my home reno the original heating system was from 1948. Gravity with an added blower system that worked fine until this new high efficient system put in
    With 3 flashes to help me start off troubleshooting lol

  • @tthoutx1
    @tthoutx1 2 หลายเดือนก่อน

    $600.00 to replace a Gas Value? Value Cost depending on the unit between $60 and $200 what’s your labor rate per hour?

  • @emilywalker7756
    @emilywalker7756 3 ปีที่แล้ว +1

    Please do a video explaining about the orifice that fits on the inducer motor assembly where the inducer motor goes to the condensate plate. On my furnace, there were no other symptoms except the darn limit switch kept tripping. When I go to replace the inducer motor, the new one came with two different size orifices that you are to clip in the opening upon installation. Well, I looked at the old inducer motor and there was NOTHING there. So I just assumed that these orifaces weren't needed. I finished installing the inducer motor without putting one of the extra orifices in it. Limit switch still tripping! I'm too frustrated to mess with it so I just have a space heater by the thermostat to keep the furnace from tripping. Im a very busy mom with three kids 9, 5, and 2. So getting back to the furnace took a few days. Tonight I went and looked to see what BTUH my furnace is and sure enough, it's a 60,000 BTUH and the smaller opening orifice is the one that I should have installed. So I take it off and put the correct size orifice in and put it back together. Praying it works, and it did! Now, someone tell me what happened to the old orifice??? There was no trace of it! It disappeared and I had no experience to know any better. I just thought it should look the same way the old one looked. Now I know! And hopefully I won't have anymore limit switch tripping for a while!!!

    • @nicksterry357
      @nicksterry357 2 ปีที่แล้ว +1

      I would really recommend just changing the limit switch as well. I'm a technician and I know they just get weaker and weaker when they trip.

  • @Andrew-rb4gs
    @Andrew-rb4gs 9 หลายเดือนก่อน +1

    This guy looks like a young Gene Hackman.

  • @familyshylov618
    @familyshylov618 ปีที่แล้ว

    Can't believe you had to explain how to provide quote to a customer:)

  • @virgil3241
    @virgil3241 3 ปีที่แล้ว +3

    More info like this, while I wont pretend to be a repair man, at least with this info a person can troubleshoot some before calling a tech, and then know what they are talking about when they explain issues

  • @dougd936
    @dougd936 3 ปีที่แล้ว +1

    Getting no voltage to inducer motor. Occaisioal liw voltage will turn it

  • @1985kenworth1
    @1985kenworth1 ปีที่แล้ว

    I seem to be having an issue with a loose connection on my has valve ,if i push in and up on the plug the gas valve will open all day ,everyday .Can the plug connection be replaced on the gas valve .All the furnace techs that have come out want to sell me a new furnace.Our furnace is a Lennox brand and came new with our new house which is 15yrs old now .

  • @yuriyfitak6942
    @yuriyfitak6942 ปีที่แล้ว

    Replaced the inducer motor 2 day ago it went out again. Is it a bad factory motor or something else is causing it to go out?

  • @billd.8336
    @billd.8336 2 ปีที่แล้ว +1

    Waiting 5 to 7 days to supply a new draft inducer will not work here in the north. It must be installed quickly or the plumbing will burst when the water freezes when the outside temp is 10 below. It's not IF but WHEN a draft inducer fails. A homeowner in the northern US should keep one on hand. Ebay has mine for about half the price that the furnace people charged me. I wish that I had never had a High-E furnace installed . We are on our second one; the first lasted only 10 years and the draft inducer on both funaces failed. The old-fashioned furnace lasted for 30 years and was still working when it was replaced. We have likely spent as much or more money for High-E furnace installation, parts and repairs than I would have spent for extra gas for the old furnace.

    • @jesuscastillo1083
      @jesuscastillo1083 ปีที่แล้ว

      Why did you replace it ?

    • @billd.8336
      @billd.8336 ปีที่แล้ว

      @@jesuscastillo1083 Bearings got noisy; did not want to wait until failure. This has happened twice now.

    • @kevinkotchevar2339
      @kevinkotchevar2339 8 หลายเดือนก่อน

      You'r a professional and your going to tell customer 5 to 7 days for a part meanwhile they have no heat. ? Truly a BS video

    • @billd.8336
      @billd.8336 8 หลายเดือนก่อน

      @@jesuscastillo1083 Heat exchanger on the first Hi-E furnace burned/corroded to make a large hole.

  • @pauljasmine353
    @pauljasmine353 10 หลายเดือนก่อน

    We also need to communicate to the customer that they need to head out to Home Depot and purchase several space heaters since it will take a week to complete the repair, and if you don't, your pipes will burst and you might freeze to death.

  • @airborne350g
    @airborne350g 2 ปีที่แล้ว

    Why does my HVAC burners shutdown during high winds from a certain direction? I think the winds are increasing the pressure in the vent pipe causing an error that is 6 short flashes then 1 long flash on the heartbeat light. If I shut the system off and then back on after a few seconds it will run fine, till the next high ends again.

  • @JesusSaves71185
    @JesusSaves71185 2 ปีที่แล้ว

    What if it works and drops out mid operation? You didn't even busy out the manometer yet?

  • @stevenoliger2763
    @stevenoliger2763 2 ปีที่แล้ว

    I have a Carrier high efficiency propane furnace. Flames at the burner were orangey and dancing a lot. Tech replaced primary & secondary HEX. Flames *still* orangey and dancing a lot! And now from time to time there is a little water apparently leaking out of the collector box. Tech now says to replace variable speed inducer for about $1K. It seems to spin fine, however. Should I believe him? Can an inducer cause problems EVEN IF it seems to have plenty of power and it doesn't make any weird noises? Most of the utube videos on inducers talk only about obvious problems like not spinning or too noisy or hot to the touch. Could my inducer be causing bad flames or leaking condensate even if it appears to be fine?

  • @scdevon
    @scdevon 2 ปีที่แล้ว +2

    "4 most common problems": The worst problem is these sealed "lubed for life" ball bearings in these motors like the Amana ones. Would it kill them to just add an oil port so that some oil can be added once in a while? The planned obsolescence is just blatant on these designs. They don't even try to disguise it anymore.

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  2 ปีที่แล้ว +1

      Very good point

    • @Jmg354
      @Jmg354 2 ปีที่แล้ว

      Do I need to lubricate the wheel barerrings, it was not making noise the first 9 months a new one installed,
      Not its a lil noisy,
      Lubricate will make it non noisy? Thanks for reading

  • @truthseeker6713
    @truthseeker6713 ปีที่แล้ว

    If my inducer motor capacitor is rated at 3 micro farads but is reading 2.6, could it stop inducer motor from running?

  • @jonnymakers9560
    @jonnymakers9560 6 หลายเดือนก่อน

    My brand new furnace makes a horrible whine noise..I have troubleshoot this to the inducer motor...I have contacted the installer..so who knows...

  • @hellofriends8334
    @hellofriends8334 2 ปีที่แล้ว

    Will the inducer motor run if the pressure switch is bad?

  • @multicammando
    @multicammando 3 ปีที่แล้ว

    Awesome video!!!!!!!

  • @hansdoreen
    @hansdoreen 9 หลายเดือนก่อน

    My furnace always have the blower motor on first then the inducer motor + ignitor.

  • @tacktiician4978
    @tacktiician4978 2 ปีที่แล้ว +1

    Hello Fox! My lennox furnace is inconsistently and sparatically not kicking on. I get pressure sensor errors which make me assume its the inducer because i already changed the sensor and the issue persists. I hear a little rattling type noises coming from what seems like the inducer.. but what is odd is sometimes it can run fine for days and then out of no where trigger over and over.. any advice? Thanks

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  2 ปีที่แล้ว +1

      Check the back of the control board. If any of the solder connections are cracked (behind the plastic plug in to the board)trace those two wires to the inducer and check the solder connection on the back. My point is if those little Volcanos are cracked then the connections are intermittently not send the signal to the board. Not saying that's it, but good to check first. Make sure you unplug the furnace 😅

  • @wanderer3444
    @wanderer3444 ปีที่แล้ว

    Hi, power surge while furnace was running at peak in January in Alberta so...cold!!! ( Comfortmaker Model G9MAE1002122A) caused inducer motor fault. I reset at fuse box and rebooted with panel switch 5 or 6 times and inducer kicked in and ran as normal (no unusual sounds) Furnace ran great. Skip to roughly April (warming up, still cool) I was away from home for a week came home and clocks were flashing, so another power surge! Furnace is shut off...inducer motor fault again, have tried the reset routine....well a lot more than 5 or 6 times! and no luck, any ideas? Thank you in advance!!!

  • @boatbuilder1954
    @boatbuilder1954 2 ปีที่แล้ว +1

    Can I just buy the motor instead of the whole assembly?
    I have a jakel 119394-00 or icp1172823 inducer assembly and need just the motor
    I see several motors on the internet but don't know just the motor number. Thank You

  • @mikesbigpics8697
    @mikesbigpics8697 3 ปีที่แล้ว

    Great video

  • @marshallandroxy
    @marshallandroxy ปีที่แล้ว

    When the thermostat calls for heat, my unit works just fine. But when running a/c the induction fan just keeps cycling on and off, (but spinning slower than when running heat). Gas never turn on during the cycling and the igniter never glows. What do I need to check first? Thermostat voltage?

    • @billd.8336
      @billd.8336 8 หลายเดือนก่อน

      Failed control board? I have lost one each with two Hi-E furnaces. I want my old fashioned furnace back but they took it away and I let them do it; stupid me!

  • @deansherrick3998
    @deansherrick3998 2 ปีที่แล้ว

    I have noticed that our TRANE XV90 inducer fan runs for a while after the furnace reaches the temperature that is on the thermostat. Sometimes for 15 minutes or more.
    When I shutdown the furnace; either by the master switch or the thermostat and then turn it back on, the inducer fan is quiet.
    This is not the main air flow fan directed into the house, but the smaller fan connected internally to the furnace - the inducer fan.
    This fan & its smaller squirrel cage appears to draw combustion air from the furnace and exhaust it out of the house via the PVC pipe installed. This fan is a PSC unit as it does not have a square variable speed unit - it is simply a cylindrical motor mounted to this small squirrel cage - I think it is a two-speed unit though.
    Any thoughts as to why this inducer motor would run on for so long after the furnace reaches the temperature set on the thermostat? Thanks in advance!

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  2 ปีที่แล้ว

      15 minutes is a long time. If that is true though something could be sticking on the board. Is it the same amount of time every time?

    • @deansherrick3998
      @deansherrick3998 2 ปีที่แล้ว

      @@foxfamilyheatingandaircond4696 Thanks for getting back to me. I am not sure as I usually turn it off via the thermostat and then back on. When I do this it does not come back on.
      If there is something "sticking on the board" as you list, I am concerned. Both operationally and financially.

  • @christineciccione3954
    @christineciccione3954 ปีที่แล้ว

    I just had a furnace guy out here to clean/service my furnace. My furnace gas had a rattle sound, and he said it is the inducer. The inducer was hot and when he turned it, it sounded like a skateboard wheel. He said that since my furnace is 16yrs old, he told me to start thinking about another furnace rather than replacing the inducer. Is that the only sensible choice?

    • @johnwilliamson4511
      @johnwilliamson4511 ปีที่แล้ว +1

      Typically, heat exchanger(s) are the most expensive component to replace on a gas furnace. Blower or inducer motors are servicable parts and pretty economical in comparison to a new system. Replace the inducer motor now and start planning for a new system in future. Get minimum three quotes and try compare similar systems.

    • @johnwilliamson4511
      @johnwilliamson4511 ปีที่แล้ว

      Could be inducer motor bearings or blower wheel going bad. Typically not servicable and require inducer motor replacement. Does not mean need new gas furnace and requires total gas furnace replacement.

    • @SpyderBlackOfficial
      @SpyderBlackOfficial ปีที่แล้ว

      No do not replace furnace.

  • @jaredabegg8202
    @jaredabegg8202 2 ปีที่แล้ว

    Zero trouble shooting in this video

  • @thurm101
    @thurm101 2 ปีที่แล้ว

    Bingo!!!! You hit mine fight on the nose.

  • @macktheknife1432
    @macktheknife1432 ปีที่แล้ว

    I have a carrier furnace with inducer with an AO Smith motor. The inducer makes a whining noise for about 2-3 seconds when the furnace starts up and after that there are no abnormal sounds coming from it. Any thoughts on my problem. Thanks for the video information.

    • @jeffbudzisz160
      @jeffbudzisz160 ปีที่แล้ว

      Same here, what did you find out?

    • @macktheknife1432
      @macktheknife1432 ปีที่แล้ว +1

      @@jeffbudzisz160 it turned out to be a bad bearing in the fan motor which I found out after replacing the inducer. So I got both new.

  • @michaelhernandez439
    @michaelhernandez439 ปีที่แล้ว

    I changed the control board and the inducer motor now runs counter clockwise.

  • @fissahadarge302
    @fissahadarge302 2 ปีที่แล้ว

    I was trying to order the base plate to which the inducer motor housing is secured. Since I couldn't figure out the name or part number of the product I was unable to order. It is the part from which the pressure switch orifice protrudes. Any help is appreciated.

    • @The1JBanks
      @The1JBanks 2 ปีที่แล้ว +1

      I think you mean the flue box cover if it’s a package unit.

  • @jamesnorth1063
    @jamesnorth1063 3 ปีที่แล้ว

    Should the inducer motor continue running when the main blower comes on, or should it stop at that point?

  • @steven-ky2ps
    @steven-ky2ps 3 ปีที่แล้ว

    my funace quit altogether. the LED is showing no faults. i put 120 to inducer and it runs fine. get 24 volts from the thermostat. when i turn up the thermostat I can hear a 'click', what i assume is a relay for the inducer motor, but nothing happens. Furnace is one year old. Bad relay you think?

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  3 ปีที่แล้ว

      If you're reading 120 leaving the board then bad motor, if not leaving the board from the inducer terminals then bad board. Check with an amp clamp too. Like you said when you jump it, it works so I'm thinking something upstream of the motor. If there are any safeties tripped. Ie pressure switch stuck open, open high limit, etc that could prevent voltage getting to inducer as well. Good luck! 😊

  • @jmsjro6
    @jmsjro6 3 ปีที่แล้ว

    Will the furnace kick on and work if the inducer motor is not operating?

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  3 ปีที่แล้ว

      No it shouldn't. The inducer is a safety feature that gets rid of the spent gasses of the furnace. No inducer, no pressure switch activates, no gas valve etc.

    • @jmsjro6
      @jmsjro6 3 ปีที่แล้ว

      @@foxfamilyheatingandaircond4696 I didn't think so. We just moved into this house not long ago and our old house you could hear the motor. In this house I had to look in there to make sure it is working...It is spinning, but quiet compared to our last home. Thanks for the reply.

  • @thejusticeappalachianhomes1454
    @thejusticeappalachianhomes1454 2 ปีที่แล้ว

    Ok...fire burns...got it!

  • @hotwheel6663
    @hotwheel6663 2 ปีที่แล้ว

    Mine was whining but stopped?

  • @dougd936
    @dougd936 3 ปีที่แล้ว +1

    REPLACE INDUCER MOTOR 2 YR AGO STILL TURNS SMOOTH NO NOISE. NO POWER GETTING TO MOTOR

    • @aaronrodden8121
      @aaronrodden8121 ปีที่แล้ว

      Did you figure this out? Check power source, check the connection, check control board solder joints.

  • @spooky9030
    @spooky9030 ปีที่แล้ว

    Man im cold as hek and my furnace is😮😮 not working i already tried a few tips. Nothing seems to work but again im not a professional so i dont do more than i should. And im broke right now Fml.
    Guess I’lljust have to deal w it.

  • @Jmg354
    @Jmg354 2 ปีที่แล้ว

    I replaced it 12 months ago,
    A new one, and wheel already making noise again

  • @davidcoles2113
    @davidcoles2113 3 ปีที่แล้ว +1

    Does the inducer motor stay on while the heater is running

    • @foxfamilyheatingandaircond4696
      @foxfamilyheatingandaircond4696  3 ปีที่แล้ว +2

      Yes it does. In order to keep drawing those gasses out of the heat exchanger

    • @davidcoles2113
      @davidcoles2113 3 ปีที่แล้ว

      @@foxfamilyheatingandaircond4696 ok tks went to start my heater and it took a min to start spinning, heater fired up, checked on it after a few mins and it was not turning, heater was starting to melt the wire for the igniter

    • @davidcoles2113
      @davidcoles2113 3 ปีที่แล้ว

      @@foxfamilyheatingandaircond4696 tks for the fast answer it's cold and no heat lol

  • @moistj69
    @moistj69 3 ปีที่แล้ว

    Good videos, but all you have to do to work on it is turn it off on the circuit box. Definitely not that dangerous. Plus 50 bucks for a new motor is way better than 50 bucks for a new motor plus 150 bucks for somebody to come replace it.

    • @metatechnologist
      @metatechnologist 2 ปีที่แล้ว +1

      He has to cite what he did for legal reasons some people are not careful.

    • @madcowusa4277
      @madcowusa4277 2 ปีที่แล้ว

      $50? I'd like to know where. Around $335 for an inducer motor, part and gasket only. You can get them from distributors selling on Amazon if need be.

    • @moistj69
      @moistj69 2 ปีที่แล้ว

      @@madcowusa4277 it’s a hypothetical price. My point is it’s cheaper to do it yourself

  • @georgekolos5255
    @georgekolos5255 3 ปีที่แล้ว

    Start winding on inducer motor (;

  • @michaelmyers4999
    @michaelmyers4999 4 หลายเดือนก่อน

    Or there's a bird in the motor

  • @ronalddaub9740
    @ronalddaub9740 2 ปีที่แล้ว

    I must be a professional then because I can fix that except for that stupid computer but give me some more diagnostic tools and I'll figure it out I got a wire running to my bedroom right now to fool that pancake switch into thinking it's getting vaccine until I get it fixed properly, I know electronics I know physics and I know electricity and I know relays capacitors limit switches thermal switches if you just got to know which ones do what when

  • @crand20033
    @crand20033 2 ปีที่แล้ว +2

    Charges $600 dollars to replace a 50 dollar gas control valve? No thanks I'll just watch TH-cam and learn how to replace it myself. You guys are crooks.

    • @hatethetube46
      @hatethetube46 2 ปีที่แล้ว +1

      The guys that made and gave you the video content that allowed you to save $600 are crooks?

    • @crand20033
      @crand20033 2 ปีที่แล้ว

      @@hatethetube46 OK, but I guess you can charge whatever you want when the heat shuts down and it's really cold outside. I had one guy come out and charge me $250 and all he did was clean my flame sensor so the furnace would work again. So that why I want to learn what to do and fix it myself. The ignitor wouldn't be hard to replace if that goes bad either.

    • @hatethetube46
      @hatethetube46 2 ปีที่แล้ว

      @@crand20033 Hey I fully agree. I just taught myself how my furnace works on TH-cam and fixed it for free, saving unknown hundreds of dollars.
      I’d like to extend a huge than you to Greg Fox and company for this video and the “diagnosing furnace pressure switch” video. Both helped me through my project.

    • @crand20033
      @crand20033 2 ปีที่แล้ว +1

      @@hatethetube46 Yes and you might have to replace your Inducer Motor too if that starts making noise. It's fairly easy to do.

  • @reeceportal1530
    @reeceportal1530 7 หลายเดือนก่อน

    too much mug shots

  • @rickye7738
    @rickye7738 8 หลายเดือนก่อน

    My inducer motor isn't coming on until the flame lights, and both immediately shut down because of open pressure switch. I've replaced the board, pressure, inducer motor and flame sensor. Any idea?