DTC(delta temp controller) - PLC Communication through MODBUS

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 พ.ย. 2024

ความคิดเห็น • 26

  • @shakilgadhakdawala8748
    @shakilgadhakdawala8748 5 ปีที่แล้ว

    I want to communication between Delta plc and ms1208 8 channel multispan temperature controller....how can I do that

  • @AhmedHassan-vh2wx
    @AhmedHassan-vh2wx 5 ปีที่แล้ว

    i do this program exactly but the value of regester D1050 WAS 32277 , IS THIS TRUE I DO NOT CONNECT TEMP SENSOR , I SHORTED BETWEN TERMINAL 1,2 IN DTC

    • @demoplcprog540
      @demoplcprog540  4 ปีที่แล้ว +1

      no its an garbage value.give right sensor type to DTC.

    • @Raiwind-boys
      @Raiwind-boys 4 ปีที่แล้ว

      Bahi ek sw ziada temperature controller kay lie yahi ho gi
      Programing
      D1050
      Secnd kiya ho ga d1051

  • @jaison1202
    @jaison1202 4 ปีที่แล้ว

    Excellent

  • @tariqjordan4334
    @tariqjordan4334 6 ปีที่แล้ว

    Can I connect PM2120 schneider power monitor with delta plc sx2 via RS485 modbus? thanks for your response

    • @demoplcprog540
      @demoplcprog540  5 ปีที่แล้ว +1

      Yes off course.. no issue with that

    • @tariqjordan4334
      @tariqjordan4334 5 ปีที่แล้ว

      @@demoplcprog540 thank you..could you please provide me the required instructions for communication and read data from pm2120 because I have tried the program in your video but I can't read from the controller.

  • @madhanraj38
    @madhanraj38 5 ปีที่แล้ว

    Sir,pls tell me what is difference between DTC temperature Controller and 4 channel Thermocouple module or rtd module

    • @demoplcprog540
      @demoplcprog540  5 ปีที่แล้ว

      DTC you can add multiple sensor like even current or voltage as temperature sensor having more options like graph, control, alarm etc more details are in manul. Still if you need something you can ask me.

  • @raheels.1068
    @raheels.1068 6 ปีที่แล้ว

    hi, how i can get out put 0-20ma ? delta dtb4896cr model ? i want use it with vfd without plc

    • @demoplcprog540
      @demoplcprog540  6 ปีที่แล้ว

      4-20 can be possible without any setting

  • @abdussamadmail4482
    @abdussamadmail4482 5 ปีที่แล้ว

    What about if two controller with a plc for d1050, for 2nd controller d1051?

    • @demoplcprog540
      @demoplcprog540  5 ปีที่แล้ว

      NO,2 controller device id is 1 and 2 address will be the same i.e.D1050 .you need drum sequence prog to move the value

  • @arunprasath3944
    @arunprasath3944 4 ปีที่แล้ว

    super bro. I done everything like you bro but { 6:53 } during online mode d1050 value not varied stayed in k306. i am varying temp also, can you guide me

    • @demoplcprog540
      @demoplcprog540  4 ปีที่แล้ว +1

      Please check drum Sequncer video maybe that will help you. If you are Communaiting with dop Or other hmi then it will be very easy to understand

    • @arunprasath3944
      @arunprasath3944 4 ปีที่แล้ว

      @@demoplcprog540Thank you very much Bro.it is working very well, can you post video about how to programming two dtc1000r at a time with delta plc

  • @raheels.1068
    @raheels.1068 6 ปีที่แล้ว

    It's temptaure controller. But I not getting output 4-20ma. Just all time on output 13.47v dc output.

    • @demoplcprog540
      @demoplcprog540  6 ปีที่แล้ว

      Raheel S
      ok I will check and revert to you
      send your mail id

    • @demoplcprog540
      @demoplcprog540  6 ปีที่แล้ว

      Please check what value it shows in 1012H and 1013H register
      You can also set it
      If it shows 100 and current is not 20mA then device must be faulty

  • @rockgangadharan8531
    @rockgangadharan8531 4 ปีที่แล้ว

    sir how to wire and communicate 14ss and delta hmi and dtc 1000

    • @demoplcprog540
      @demoplcprog540  4 ปีที่แล้ว

      For dtc and hmi direct 485 communication can be establish. And for hmi and plc use 232 communication.

  • @lalitsingh1105
    @lalitsingh1105 6 ปีที่แล้ว

    Hi,
    I wnt to Communicate 6 DTC what changes need in this program.

    • @demoplcprog540
      @demoplcprog540  6 ปีที่แล้ว

      Addressing of dtc will be chenge viz k1,k2,k3,k4,k5.
      But you also need drum sequncer otherwise your PLC show faulty value

  • @Raiwind-boys
    @Raiwind-boys 4 ปีที่แล้ว

    More then temperature controller control