Bhai thank you so much, mai pahli baar Kuwait k liye ja raha hu, genral fitter me kabhi kaam nhi kiya, lekin interview ko jane vala hu, aapke video ne bahut kuch sikha diya mujhe. Thank you again,
Dear I m watching from Saudi Arabia but very useful information thank you for your efforts and good information I try to machnical supervisor again and again thank you appreciate your speech very clear. Sincerely..
वाह सोनू भाई इतना बढ़िया एक्सप्लानेशन आजतक नहीं मिला था मुझे यूट्यूब पर। मै काम कर चुका हूं कॉलम पर बिल्कुल ऐसे ही काम होता है मैंटेंस का। हीटर, फिनफैन, एक्सचेंजर का भी ऐसे ही वीडियो अपलोड कीजिए। धन्यवाद।
Us ne bola hota hi nahi h.. Client ne bola Vessel me hota h.Mai Bola Sir Vessel me hota h. But Distillation Column me v hota h..Wo Direct bola hota hi nahi h. Pta na kaise-kaise Client bn ke aate h.
Mera Matlab ye hai ki bottom side sey manway tray open karty hai to us tray kaa numbering kaisey karty hai. Ex- ek column me 4 main hole hai. To bottom side sey manway Trey open karty huy top manway tray open karengy to sarey tray kaa numbering kaisey karengy.
Kvi bhi manway jab open hota h aur tray nikala jata hai to upar se niche ki ore jate hai aur numbering aapke upar depend karta hai ki aap kaise karte hai jaise pahle level per 1A, 1B, 1C....dusre level per 2A, 2B, 2C... tisre level per 3A, 3B, 3C.....agar total 40 tray ka level hai to last wala 40A, 40B, 40C....is tarike se aap kar sakte hai.
Wo depend karta h ki column ka dia kitna h, jitna jayada dai hoga utna jayada time lagega, waise 2 shift me bhi nikal sakta h, ye fitter per bhi depend karta h, koi fix rule nhi h, agar manpower ka baat h to 2 aadmi column ke andar, 2 bahar aur ek hole watcher total 5 aadmi chahiye minimum.
Buffing ek tarah se bhai grinding ki tarah hota h but isme grinding machine ke jagah buffing machine ka use karte h jo compressed air se chalta h jisse jitne bhi welding joints hote h unko clean kiya jata h
It is very simple if you are familiar of maintenance work but in simple you should have all spanners and always start opening trays from top side of manway of any column and go downward and similarly during installation you should always fix trays from downward to topward. If you have still any doubt please feel free to comment below. Thanks for asking questions...
Follow us on Instagram - instagram.com/sonusinghrefinery
Bhai thank you so much, mai pahli baar Kuwait k liye ja raha hu, genral fitter me kabhi kaam nhi kiya, lekin interview ko jane vala hu, aapke video ne bahut kuch sikha diya mujhe.
Thank you again,
Dear I m watching from Saudi Arabia but very useful information thank you for your efforts and good information I try to machnical supervisor again and again thank you appreciate your speech very clear.
Sincerely..
bhut acha ap ne samjhaya abhi tak jo bhi videos ate hain acha samjh me nhi ata ye bhut acha smajh me aa geya
Thanks brother...
वाह सोनू भाई इतना बढ़िया एक्सप्लानेशन आजतक नहीं मिला था मुझे यूट्यूब पर। मै काम कर चुका हूं कॉलम पर बिल्कुल ऐसे ही काम होता है मैंटेंस का। हीटर, फिनफैन, एक्सचेंजर का भी ऐसे ही वीडियो अपलोड कीजिए। धन्यवाद।
फिन-फैन और एक्सचेंजर का वीडियो डाला हुआ है मैं कोशिश करूंगा कि हीटर का भी वीडियो जल्दी अपलोड हो जाए
Bhai whatsap number please
Nice👍
Q1@@SoNuSiNgHRefinery
Thanks # sonu sir aapke bataye huye Har topik humne follo kiya,,, bahut bahut sukriya
Thank you
Bahut vadiya sonu ji bahut jayda sikhney ko mil raha hai aapsey
Thnk u vry good video I am from pakistan. Best video
Very helpful video
Video bahut achhi lagi ek chiz isme nahi bataya aap ne kuchh column me Trey ka hydrotest bhi hota hai uske bare me bhi bataye
Ha yar wo raha gya actually leak test bolte h usko...
Helpful video Sonu bhaiya 🙏🏼
Very nice video sir good explanation
Lots of thanks sir Really great sir ❤️❤️❤️❤️
Sonu Bhai very thanks Aap ko video banane ke liye
Sir iocl me apprentice chemical se kar liye hame v padhna hoga ye refinery me ham se ye work nahi karbaya gya tha
Ek client ne bola Distillation Column me Demister pad Nahi hota h.. Kya wo Sahi bola. Please Reply.
Sab me nhi hota h but aisa nhi h ki hota hi nhi h, bilkul column me bhi demister pad hota h
Us ne bola hota hi nahi h.. Client ne bola Vessel me hota h.Mai Bola Sir Vessel me hota h. But Distillation Column me v hota h..Wo Direct bola hota hi nahi h. Pta na kaise-kaise Client bn ke aate h.
Ab kya bol sakte h aise logon ko
Steam turbine Compressor ka details wala video nai he aapki channel par.
Very good explanation brother
Sir aap bhot achha information dete ho
Bhi volta meter khan use hota columns mn kindly detail mn btaiye?
Sir please upload full operator details of CUD,VUD etc.
Column ko kis chij se clean karte he
Nozzal kitne pirkar ki hoti hai
Bhai ek sawal kiya tha mujhe agar kisi tank par wL 40 likha ho to iska matlab kya hai
Given a great knowledge through this column regard.
Please be continued with another video.
And start from basic to end.
Sonu Bhai aap ki Umar long ho healthy ho
🙏🙏🙏
I like this your video sir
Thanks please share with friends
Sir colume maximum hieght Kitana hot hai
Sir kuchh during bhi h
Very nice video
U r all videos are awesome bro.pls elaborate more...
Thanks brother for your appreciation🙏🙏🙏 Please share it with friends
Gass kit kitna prakar ka hoten hai
Vari good vari NIS
So hrkuch mere bhai ...love u
Bahut badhiya tarike se aapane colum ke sambandh mein bataya thoda sa gas kit ke vishay mein bataen de please column mein hydro test liya jata hai
Avi Tak to Maine column ka hydrotest nhi Kiya h but ha seal pan ka leak test jarur hota h
Very good sir g
Very nice 👍 thank t
Sir column ke aandar nat bolt kholne ke liye kona sa spainer lagega
16-17 ka jayadayar lagta h
Tq sir ❤️
Domister pad ka thikness kitna hota hai
🙏reply to digiye sir 🙏
Tray ka thiknesss kitna hota hai
Aaj ka interview me pucha gya ye question
Column me tray k kitne step hote hai
Vessel ka or heat exchanger ka maintenance ka vedio banaw sir . Aap bahut super style hai samjha ka
Thanks brother please share video if you really like...
टोटल कितने प्रकार के एक्सचेंजर होते हैं
एक्सचेंजर वाला प्लेलिस्ट देखिए |
Sir Why tray manway box up is done from downward to upward.
Suppose you are going upward to downward then how will you exit from bottom? Think about it...
In column where we will stand?
Good 👍
pipe isometric drawing all shhet number and continuity how to find out immediately uptate sir.
good video sir g
sir kindly i want to know about what type of gasket use in destilation coloumn name please
and 2nd which size of spanner use for trays
Spiral wound gasket used and 17-18 spanner
@@SoNuSiNgHRefinery Thanks you sir for feed back
menave kaun sa pahale band hoga
Kaun sa kab use karate hai jaise ki bublecap tray,sive tray ,randum trays etc please sir
Ye sab material production or reaction per depends karta h ki andar kaun sa material h kya ban rha h
Well explained 👍❤️
Very nice video sir... Describe everything thoroughly
Very good
Superb
What is the work of pipe fitter and fabricator work in shutdown work in refinery .please reply.....
Hello sir..
Muje chemical company me maintenance me jana he to... reactor aur pressure vessel ko step by step maintenance kese karte he vo bataye na
Pressure vessel ka maintenance ka video playlist me hai aap ek bar jarur dekhe playlist... Agar kuchh samajne me problem ho to comment jarur kare
Thanks sir but aapka number mil sakta he.... Query ke liye
Sir please make a video about Furnace and Reformer
Sir very nice
Tray kaa numbering kaisey karty hai.plese explain Sanu ji
Thoda aur explain kijiye samajh me nhi aaya ki aap kya janana chahte h
Mera Matlab ye hai ki bottom side sey manway tray open karty hai to us tray kaa numbering kaisey karty hai.
Ex- ek column me 4 main hole hai. To bottom side sey manway Trey open karty huy top manway tray open karengy to sarey tray kaa numbering kaisey karengy.
Kvi bhi manway jab open hota h aur tray nikala jata hai to upar se niche ki ore jate hai aur numbering aapke upar depend karta hai ki aap kaise karte hai jaise pahle level per 1A, 1B, 1C....dusre level per 2A, 2B, 2C...
tisre level per 3A, 3B, 3C.....agar total 40 tray ka level hai to last wala 40A, 40B, 40C....is tarike se aap kar sakte hai.
Super information
Thanks
Sonu bhai
Why do tray box-up from downward to upward
Plz explain in brief
Sir colum ke andar jane ke liye konsi parmit lena chahiye sir
Confined space ka
Sonu bhai colum ka inspection ka ek video bnaye na
Reactor ka maintenance kaise karte hain..
Please make a video Sonu bhai
What is weir height in distilation column?? This question was asked by interviewer to me.
Typically 25 to 50 mm
@@SoNuSiNgHRefinery ok sir but weir height kise kehte hai?
Downcomer ke sath me angle jaisa laga rhta h jo tray per fluid ko hold karta h to Jo angle ka height hota h use hi weir height kahte h
Sir please column trey ka image and name bataye please
Sir column ka trays kitni par ka hota hai
4-5 tarah ke mainly use kiye jate h jaise valve tray, sieve tray, bubble cap tray, dual flow tray....
1to 19 tray remove karne me kitna shift lgega aur kitne manpower lgega yh questions aj mujh se pucha gya
Wo depend karta h ki column ka dia kitna h, jitna jayada dai hoga utna jayada time lagega, waise 2 shift me bhi nikal sakta h, ye fitter per bhi depend karta h, koi fix rule nhi h, agar manpower ka baat h to 2 aadmi column ke andar, 2 bahar aur ek hole watcher total 5 aadmi chahiye minimum.
@@SoNuSiNgHRefinery 4mm dia tha Coulmn ka
Bhai aap tank aur cooling tower Ka maintenance aur reactor Ka bhi video banaye
Nice video
Dil se se se salama
Really awsome
Bhai Mainway ka size kya hota hai
Mostly 24" Hota hai
Good
Sir riser keya hi
Boss meterial lifting shifting ke bare me details ki ek video banaiye
Hello sir bolt torquing ke bare mein bhi ek video banaen complete
Great information.
Turbine ka video share kare
Sir mai fresher hu aur refinery me job krne ja rhu hu,sir waha pe safety me kya kya dekhna hota hai,help me sir
Job se pahle daily Tool Box Talk hota h usme aapko bataya jayega safety ke baare me.
Nice vedio
Sir how to identify which type of gasket use in exchangers
Types of gasket used in the heat exchanger depends upon the process flow of fluid which is passing through exchanger...
Wow😯
Sir coluam ka drawing dekhna sikhne ke liye ek video banaye na please
sir colomn k andaar DIGREE kese nikalun???
Subhendu ji kiska degree nikalna h
kisi out/inlet ke ya fer andar marking jo kam hai uske barenain video banate to bohut a66a hota.
How many types of columns? distillation and other what?
Sir describe the distributor in distillation column
Hit exchengr ka floatinghed testing. Batao sir
Nice sar
Nice
Sonu ji Namaskar flange tee & 45 degree elbow fittup ka video daliyega
Vry nice bhai
Thanks bhai
Bro buffing kese Hoti he bro mujhe bta do bhai ...sat ya Sunday Ko interview ho skti he ...plz bta de bro
Buffing ek tarah se bhai grinding ki tarah hota h but isme grinding machine ke jagah buffing machine ka use karte h jo compressed air se chalta h jisse jitne bhi welding joints hote h unko clean kiya jata h
Ok bro... thanks
Tight bolt in opposite position.
Must Use Blinding and De-Blinding list.
Trays used:-
Bubbl cup tray
Valve tray
Sieve tray
chimney tray
Super brother please make more inspecton vedios on like exchanger, vessel, reactor ,& heater
Thanks brother
Good sir
Thanks brother
Your All video is Good... But please Elaborate more.
What are the common deffects found inside distillation tower found during shut down.
thank you sir
dear sir, can you explain the details regarading pressure vessel n ractor
How to remove trays and how to install in a distillation column
It is very simple if you are familiar of maintenance work but in simple you should have all spanners and always start opening trays from top side of manway of any column and go downward and similarly during installation you should always fix trays from downward to topward. If you have still any doubt please feel free to comment below.
Thanks for asking questions...