Thank you so much for this vid. I installed a new AC unit about 2 months ago, but it would not blow cold or hot air. After going through youtube videos after videos and purchasing a vacuum machine along with all the bits and pieces such as cables and refrigerant (Believe me, "R32" is hard to come by in Europe!) I still could not get the Unit working. The extras I purchased didn't come cheap either and added at least another 200 euros onto the overall cost. However, after getting ready to give up with a total sad on... I came across this video and followed it step by step. (I luckily had a full bottle of R32) Best video by far. Again, thank you.
super video bro....excellent efforts that you have put in making this wonderful and informative video....it can be understood even by a novice like me...these allegedly AC technicians are burning my pockets every summer and they don't even explain what they did but they charge money stating that they have filled the gas.....now i got a clear picture....thanks a million for such a lovely video....good luck to you...
I watch your videos becouse i own same car (Kia) as you. And i find this video and i must say you are real pro. Becouse i work with AC units and the way how you can repair nearly everything and use old parts to helps you to succes is outstanding. So i wish you good luck ! Little advice, some refrigerants can be flammable and explosive so you cant always use your old compressor for make vaacum. GL
My name is Dian Pelangi from Jakarta in Indonesia, I am a fashion designer and I want to use this media to tell everyone to be careful about getting loans on the internet, so many lenders here are fraudsters and they are here. tricking you with your hard-earned money, I applied for a loan for around Rp900,000,000 women in Malaysia and I lost around 29 million without taking a loan, I paid almost 29 million still I didn't get a loan and my business was about crashing because of debt. When I searched for a reliable private loan company, I saw another online advertisement and the name of the company was THE WORLD LOAN COMPANY. I lost 15 million with them and to this day, I have never received the loan I proposed. Dear God, my friends who applied for loans also received the loans, introducing me to a trustworthy company where Mrs. Christabel worked as a branch manager, and I applied for a loan of Rp900,000,000 and they asked for my credentials, and after that they finished verifying my details, the loan was approved for me and I thought it was just a joke, and maybe this was one of the cheats that made I lost money, but I was stunned. When I get my loan in less than 6 hours with a low interest rate of 2% without collateral I am very happy that God used my friend who contacted them and introduced me to them and because I survived making my business soar high in the air and liquidated and now my business is flying high in Indonesia and no one will say it. know about fashion companies. So I suggest all people who live in Indonesia and other countries who need loans for one purpose or another to contact christabel mother via email: christabelloancompany@gmail.com You can also contact me at my email: (lianmeylady@gmail.com) and Sety introduces and talks about christabel, she also gets a new loan from christabel, you can also contact her via her email: permatabudiwati@gmail.com Now, all who will I do is try to fulfill loan payments that I send directly to their account every month. A word for wise men is enough Thank you once again for reading my testimony, and may the Lord continue to bless us and give us a long life and a prosperous life and may God do the same good work in your life. Good mother Christabel Missan What'sApp number +15614916019
thank you for sharing your knowledge with the us... and the world. may you prosper and become more of an expert in HVAC and split aircons. I just bought a 24,000 BTU Senville and will install it myself. Be well my friend.
Hi, I really like your video. I do have some doubts, if you able to help me with the same it will more helpful for me. 1) Is it necessary to put the gas cylinder upside-down while charging the gas? 2) I do have 1.5 ton LG window ac and the amp reading is like started with10-12 and goes upto 20-22. To cross-check I have changed the capacitor but it still the same. The amp mentioned in my ac is 8.5. I just wanted to know that is it okay or there is any kind of fault? 3) The ac is not dripping water. I mean the pressure is 64. It creates the cooling effect but not upto the point. It make water a bit in the condenser coil but not dripping. At the same place there is another ac which is dripping water like hell... I am waiting for your reply and thanks in advance.
He will get the fine sooner or later lol. I'm just puzzled with the fact he filled the unit with air rather than nitrogen... air is a non condensible and it doesnt belong in the unit. I hope I just missed something in the video.
why didn't you vacuum the middle (yellow) pipe also? if you did, you didn't have to purge it with gas. Vacuming does a better job and its also not eco unfriendly. At the end, why didn't you first close the valve with the allen wrench before unscrewing the blue pipe, so no gas would go out.. I am still learning so I want to know the right way to do this..
+Ivan Rimac Thank you Good question Answer first question The yellow tube i vacuum it at 1:30 to 3:15, but when i disconnect the yellow tube from the compressor, and connected to bottle that it refill the air again
+Ivan Rimac For the second question i close the valve or not the freon came out because when i close the valve it cut between the yellow tube and the outdoor unet.not cut the way between the indoor unet and the yellow so its useless to close it
Interesting, when the unit is in low in refrigerant in winter time. But dunno the technical side of it when removing the valve wires on the caps. Further details perhaps? Thanks!
+Arnel Angeles When the valves wire is removed on the capasitor in this case, the cycle of the Freon (R22) is reversed, and the hot air becomes cold. The result is that the tube that is connected with the gage is converted from push to pull and thus you can withdraw the freon (R22) from the bottle .welcome
Excellent video and description. I have a 1998 Mitsubishi split system 2.5 kw,, it is now 22 years old and still working,,, I have shifted the unit a few times, and lost some R22. My 5 kg bottle is empty and I cannot purchase more R22 because I am not licensed. All cooking gas in Aus is pure propane, so what I have done: purged the lives with propane, tightened the connection and the job done in 5 minutes. The amount op propane which escapes is less than opening for the gas cooking stove before igniting also same for my gas hot water system. I am about to install an new 2.5 kw split system with the new gas R32 which is compatible with R290 which I believe is pure propane (though I am not 100 % sure about that), but it is propane nonetheless, and I will use same procedure. I have pump and gauges,,, but why bother, purge the lines with propane.
You dont depend for charging freon 55 or 60 you should check first the running fullload amps of your compressor, not only for charging freon you must balance the charging and amps to proper charging to save any fault
Of all my years in installing/repairing AC units, I didn't have any issues or back-jobs in constantly charging 60psi for R22. And most of those process, I didn't even use AmpMeter. So, this video is 100% reliable for any R22 AC Units!
sir I having 1ton split AC. the gas level is 35psi . & also ice is forming in indoor copper tubes through small copper tube from outdoor . 1) can u analyse the problem. 2) technician said that he need to full whole gas up to 65psi(R-22). before that remaining 35psi(R-22) gas will be vacuumed completely is the process is correct ? 3) or we can able to top-up gas from 35 to 65 psi? 4) is there any chance to having hole in condenser coil . because I having aluminum condenser coil. or it will be minor valve joint leakage.? 5) because at last I not lose the hole gas nearly 50% gas there. Plz Reply me fast it will be helpful....
Well I will try to help you but step by step 1. You said there 35 psi and this means that there is a leakage of gas and easy recovery. Find a spot of oil that is blocked from Split. And when it is found, the leak will be inside this spot
No need. It is a single component refrigerant "Chlorodifluoromethane" and not a blend. You only need to invert the tank if the refrigerant is a blend (ie, mixture of 2 or more gases such as R410). All R400 & R500 series refrigerants are blends.
@@zana3587 , then how it is that the gas doesn't goes out if you did not close on the charging side valve, unless you got schrader valve installed in it.
Hi I have seen many videos of how to service air out door unit and could not catch upwith any ,but your clip can turn a zero to hero , Thanks i leanrt a lot from this .hope to see more clips on fridge service .. tks friend
Hi, you did a very informative video for such a DIY process. I want to make my own pressure and vacuum motor as what you did using the refrigerator motor. 1) is there any specific capacity for that motor to use to pressurize and vacuum my 2 tons split AC? 2) I saw the motor has "T" handle on the top. Did you weld it as it is or you separated the tank first since I also noticed that there is welding around the middle of the tank motor. Thanks buddy.
Thank you and sorry for late- for first question the motors name is (Danfus) from Denmark and about the capacity i am not sure and for second question yes i welding the (T) hand without open the compresor
At 0:20 seconds you opened some sort of valves with allen ranch. Do we always open these valves before charging refrigerant through the service valve? And don’t you have to close the valves with allen ranch after charging?
Hi, this is better that twice vacuum,after first vacuum charge a moment gas R22 ,to degree become above zero, second vacuum , and after full gas R22.Also that is better vacuum with two stage vacuum pump.good luck.
Коллега, используйте краны на шлангах, после ваккумирования, продувать шланг надо не закрывая вентиль на баллоне, будете иметь повышенное давление конденсации!
Thank you so much for this vid. I installed a new AC unit about 2 months ago, but it would not blow cold or hot air. After going through youtube videos after videos and purchasing a vacuum machine along with all the bits and pieces such as cables and refrigerant (Believe me, "R32" is hard to come by in Europe!) I still could not get the Unit working. The extras I purchased didn't come cheap either and added at least another 200 euros onto the overall cost. However, after getting ready to give up with a total sad on... I came across this video and followed it step by step. (I luckily had a full bottle of R32) Best video by far. Again, thank you.
thank you sir i hope it's helpful for you
how I know that the pipes has air .
How many bar did u needed with r32
Q1u
This will be very beneficial for us during this pandemic to DIY our AC repairs. Very good job, man.
Thank you sir
You made our life easy. You are honest and sincere person. Thank you so much and God bless you
One of best AC servicing video on TH-cam. You are very good at what you do. 👍👍
thank you sir
nice job. thanks for painstakingly making the video and posting it online for the benefit of others.
Thank you very much sorry for the late response
Are the pressure values with r32 the same ?
TH-cam.com/c/aaziztechnical
plz visit and subscribe a aziz technical TH-cam channel for HVAC and home appliances repairing video thanks ♥️
@@elektroniknissanx-trailrog2641 no they are completely different and even the pressures he gave for 22 are too low, 70 psig would work better for 22.
Thankyou nice job
super video bro....excellent efforts that you have put in making this wonderful and informative video....it can be understood even by a novice like me...these allegedly AC technicians are burning my pockets every summer and they don't even explain what they did but they charge money stating that they have filled the gas.....now i got a clear picture....thanks a million for such a lovely video....good luck to you...
Thank you sir, i hope it's helpful for you
Thank you! I love that you show the point and not mystify it. Good work!
Bu bu haftaBu y bu bu t hu,a
Dahen Zana, many thanks. Thorough and very well done.
Thank you
Brother, your video was smarter and more helpful, with no words, than 50 videos I watched, of my American brothers, endlessly talking BS.
Thank you.
Jayesh pandya Rajkot
Sangita Pandya
What language is that? I couldn’t translate it on google.
Well he did a shit job so I'd have to disagree
thank you
wonderfull training, i appreciate your teaching please ,more video about a/c conditional am biginner....GOD BLESS YOU
thank you
Thank you, Dahen. Yours is the best video for pure instruction....greatly appreciated!
Thank you there are more videos about (how to test the capacitor, how to close the air ( R22) by close the valve and more ....) soon
I watch your videos becouse i own same car (Kia) as you. And i find this video and i must say you are real pro. Becouse i work with AC units and the way how you can repair nearly everything and use old parts to helps you to succes is outstanding. So i wish you good luck ! Little advice, some refrigerants can be flammable and explosive so you cant always use your old compressor for make vaacum. GL
Straight to the point, thank you so very much!
thank you sir
very nice information thank u so much
+S.P. SIVAN welcome man
Спасибо, ты лучший коротко и всё понятно. Thanks a lot. You best, GOOD JOB. Russia.
Спасибо, сэр
excelente video muchas gracias por fin pude entender cómo se carga de gas el aire acondicionado saludos desde República Dominicana
bienvenido señor
no,good,you,fixce
Best video ever!! Quick and easy. Thanks.
nef003 You welcome
Thank you very much, may God bless you, and I wish you continued health, progress and brilliance
thank you sir i hope it's helpful for you
Fabulous information
Thank you sir
My name is Dian Pelangi from Jakarta in Indonesia, I am a fashion designer and I want to use this media to tell everyone to be careful about getting loans on the internet, so many lenders here are fraudsters and they are here. tricking you with your hard-earned money, I applied for a loan for around Rp900,000,000 women in Malaysia and I lost around 29 million without taking a loan, I paid almost 29 million still I didn't get a loan and my business was about crashing because of debt.
When I searched for a reliable private loan company, I saw another online advertisement and the name of the company was THE WORLD LOAN COMPANY. I lost 15 million with them and to this day, I have never received the loan I proposed.
Dear God, my friends who applied for loans also received the loans, introducing me to a trustworthy company where Mrs. Christabel worked as a branch manager, and I applied for a loan of Rp900,000,000 and they asked for my credentials, and after that they finished verifying my details, the loan was approved for me and I thought it was just a joke, and maybe this was one of the cheats that made I lost money, but I was stunned. When I get my loan in less than 6 hours with a low interest rate of 2% without collateral
I am very happy that God used my friend who contacted them and introduced me to them and because I survived making my business soar high in the air and liquidated and now my business is flying high in Indonesia and no one will say it. know about fashion companies.
So I suggest all people who live in Indonesia and other countries who need loans for one purpose or another to contact
christabel mother via email: christabelloancompany@gmail.com
You can also contact me at my email: (lianmeylady@gmail.com) and Sety introduces and talks about christabel, she also gets a new loan from christabel, you can also contact her via her email: permatabudiwati@gmail.com Now, all who will I do is try to fulfill loan payments that I send directly to their account every month.
A word for wise men is enough
Thank you once again for reading my testimony, and may the Lord continue to bless us and give us a long life and a prosperous life and may God do the same good work in your life.
Good mother Christabel Missan What'sApp number +15614916019
Exellent teaching I just followed yr Instructions and reload refrigerant r22 to my minisplit unit thanks...
thank you sir
@@zana3587 Amigo como ago barrido de mangueras de manometros nesesito revisar presion de gas minisplit R410a inverter
Zabardast
Thanks for demo,so easy so fast.
thank you sir
Very instructive.
Thank you
Hvala za čudovit prikaz.Thank you very much,great video!
hvala gospod, upam, da vam bo v pomoč
Saludos de TodoFrigorista 👍 Argentina
I really love this
thank you
Nice vdieo
+Mohd Riyaz Thank you
Nice video me too !
Iqbal Halani welcome
Mohd Riyaz ygcjvkm
hanhphuccorp.com/du-an/tai-sao-may-lanh-khong-lanh--213.html
Verry good and informative with out all the talk talk talk Thanks Chris Schmidt
Thank you sir
thank you for sharing your knowledge with the us... and the world. may you prosper and become more of an expert in HVAC and split aircons. I just bought a 24,000 BTU Senville and will install it myself. Be well my friend.
Thank you
thanks for the video. did you close back both valves after recharging and putting caps back on? missed that part. thanks again.
Thank you, you should not close both valves
good observation my good engineer, because of this i watch the video 3 times , good study er
@@zana3587 meaning both valves shld remain open always?
Yes sir . Sorry for late
@@zana3587 thanks for your reply sir
Nice video
Rinku RAJPUT Thank you
Great very informative video.
thank you sir . sorry for late
*Hi, I'm from Vietnam, I also work in refrigeration, I'm happy to get to know you and everyone, wish you and everyone always luck and success*
Thank you sir
Are you online
Nice
Thank you
Hi, I really like your video. I do have some doubts, if you able to help me with the same it will more helpful for me. 1) Is it necessary to put the gas cylinder upside-down while charging the gas? 2) I do have 1.5 ton LG window ac and the amp reading is like started with10-12 and goes upto 20-22. To cross-check I have changed the capacitor but it still the same. The amp mentioned in my ac is 8.5. I just wanted to know that is it okay or there is any kind of fault? 3) The ac is not dripping water. I mean the pressure is 64. It creates the cooling effect but not upto the point. It make water a bit in the condenser coil but not dripping. At the same place there is another ac which is dripping water like hell...
I am waiting for your reply and thanks in advance.
Well I will try to help you step by step
First do not put it upside-down
all air conditioner (indoor or outdoor) written on sticker (run amp and start amp)
What is the value of the capacitor you set ?
did you say 65 psi in your air conditioner ?
Thanks for venting!
Thank you
He will get the fine sooner or later lol.
I'm just puzzled with the fact he filled the unit with air rather than nitrogen... air is a non condensible and it doesnt belong in the unit. I hope I just missed something in the video.
@@michaelgalvin9994 I like how he purged the hose then turned off the gas before tightening the hose completely negating the purge
Very nice bro . Explaining to your moument
nice
Ranajit Bhunia Thank you
You said to find the leak you should charging the system with air until 460 PSI. This is very excessive pressure and could destroy the system.
I did not have another solution. Because it was a very small leak and I could not find it. But when arrived 460 psi . i saw bubbles
200 max with nitrogen it's basic stuff
You also probably a didn't see the leak because you caused it a 460 psi
You are wrong
Not air..nitrogen is the right gas, which recommended to use when performing refrigerant leak test.
Danke! genau was ich gesucht habe.
Sie sind willkommen, Sir. alle deutsch
Vy nice sir ji
Thank you sir
why didn't you vacuum the middle (yellow) pipe also? if you did, you didn't have to purge it with gas. Vacuming does a better job and its also not eco unfriendly.
At the end, why didn't you first close the valve with the allen wrench before unscrewing the blue pipe, so no gas would go out..
I am still learning so I want to know the right way to do this..
+Ivan Rimac Thank you Good question Answer first question The yellow tube i vacuum it at 1:30 to 3:15, but when i disconnect the yellow tube from the compressor, and connected to bottle that it refill the air again
+Ivan Rimac For the second question i close the valve or not the freon came out because when i close the valve it cut between the yellow tube and the outdoor unet.not cut the way between the indoor unet and the yellow so its useless to close it
@@zana3587 this answer doesnt make sense sir, please explain better how the valves work.
Interesting, when the unit is in low in refrigerant in winter time. But dunno the technical side of it when removing the valve wires on the caps. Further details perhaps? Thanks!
+Arnel Angeles When the valves wire is removed on the capasitor in this case, the cycle of the Freon (R22) is reversed, and the hot air becomes cold. The result is that the tube that is connected with the gage is converted from push to pull and thus you can withdraw the freon (R22) from the bottle .welcome
dahen zana I can see your logic behind it in blowing hot to cold.
Sorry for the delay in the answer - in the winter can not run the air conditioner in the cool mode because the compressor not start in the cool mode
круто! ни одного слова! а всё понятно! спасибо!попробую снимать так же!
Спасибо, сэр
Ok...But You Are Hide Many More Main Steps...Any How. Gud Job☺️
Thank you sar
thank you
Do the valves where you removed the knuts from stay open even when you were done with the rifrigerent refill??
yes sir
yes u have to keep that open so refrigerant can cycle
Hi sir
Awesome video,very clear and easy to understand,keep doing these videos as it helps all of us.
From south africa
thank you sir i hope it's helpful for you, great to south africa
Excellent video and description. I have a 1998 Mitsubishi split system 2.5 kw,, it is now 22 years old and still working,,, I have shifted the unit a few times, and lost some R22. My 5 kg bottle is empty and I cannot purchase more R22 because I am not licensed. All cooking gas in Aus is pure propane, so what I have done: purged the lives with propane, tightened the connection and the job done in 5 minutes. The amount op propane which escapes is less than opening for the gas cooking stove before igniting also same for my gas hot water system. I am about to install an new 2.5 kw split system with the new gas R32 which is compatible with R290 which I believe is pure propane (though I am not 100 % sure about that), but it is propane nonetheless, and I will use same procedure. I have pump and gauges,,, but why bother, purge the lines with propane.
thank you sir
R32 is most definitely NOT compatible with propane.
R290 is propane
R32 is difluoromethane
Not even close to similar, or compatible
Vry good
You dont depend for charging freon 55 or 60 you should check first the running fullload amps of your compressor, not only for charging freon you must balance the charging and amps to proper charging to save any fault
You can not depend on an amp because the compressor and other compressor are different, especially the bad-made compressor need more amp
inverter almost connot detect the amper
Of all my years in installing/repairing AC units, I didn't have any issues or back-jobs in constantly charging 60psi for R22. And most of those process, I didn't even use AmpMeter. So, this video is 100% reliable for any R22 AC Units!
Can you make one R32?
maybe in the future
Perfect and professional way of work as well as well explained....
Hats off brother
Thank you sir
More like half assed and amateur, I'd fire a tech if they did this
@@larrynutt1581 you want to make it complicated that people ask you to do it for big money....
@@klausschumacher7126 it has to be complicated because that's the law
Nice job keep it up God bless
thank you sir
Very.sir.
thank you
ok
ok
Nice video zindabad thanks for your help
Zindabad!
hanhphuccorp.com/du-an/tai-sao-may-lanh-khong-lanh--213.html
Mulțumesc Seara frumoasa
sir I having 1ton split AC. the gas level is 35psi . & also ice is forming in indoor copper tubes through small copper tube from outdoor .
1) can u analyse the problem.
2) technician said that he need to full whole gas up to 65psi(R-22). before that remaining 35psi(R-22) gas will be vacuumed completely is the process is correct ?
3) or we can able to top-up gas from 35 to 65 psi?
4) is there any chance to having hole in condenser coil . because I having aluminum condenser coil. or it will be minor valve joint leakage.?
5) because at last I not lose the hole gas nearly 50% gas there.
Plz Reply me fast it will be helpful....
Well I will try to help you but step by step 1. You said there 35 psi and this means that there is a leakage of gas and easy recovery. Find a spot of oil that is blocked from Split. And when it is found, the leak will be inside this spot
After repairing the hole, vacuum the air as you did in the video
Can you explain more 4. I did not understand?
sir can i topup the gas level
or I should completely vacuum out & refill?
4) I typed as that there is any chance leakage in joints & valves?
the gas r22 must be revers when you charge it
You mean the bottle?
@@zana3587 yes
@@zana3587 ...
Why should it be in reverse position?
No need. It is a single component refrigerant "Chlorodifluoromethane" and not a blend. You only need to invert the tank if the refrigerant is a blend (ie, mixture of 2 or more gases such as R410). All R400 & R500 series refrigerants are blends.
good information for beginners and still required demo bith more technical details and sequence...Thank you
+Sridhar K welcome
Thats excactly what i need, THX a lot...👍
Set vacum is wrong.must do by special set vacum
What is the wrong?!
@@zana3587 a lot is wrong with how this was done
Don't you have to close the valves?
Thank you sir, and sorry for late. No sir
Why not?
If you close the valve, you close the system gas
@@zana3587 , then how it is that the gas doesn't goes out if you did not close on the charging side valve, unless you got schrader valve installed in it.
@@edward1394ablemy question exactly. Did you get an answer?
Thank you for sharing,I hope this video can give me a bit knowledge as benefits.
BRAVO, regards and THANK YOU
Thank you sir
Excellent and to the point video
thank you sir
This very nice continue thank you for that
thank you
Very clear. From Philippines
thank you sir
Best video for mini split refill!
thank you
Straight to the point useful video
thank you
Great video, nice showing big greetings
thank you sir . sorry for late
Good video thank you.
Thank you sir
بہترین کام 🌷
Thank you
thanks for sharing sir..nice job godbless
Thank you sir
Great video....it has helped me alot...thanks
Thank you sir
10/10 video grt work 👍
Thank you sir
Nice vacuum pump!
Good video . good detail and also showing the leak fault good teacher thank you 😊
thank you sir i hope it's helpful for you
Hi I have seen many videos of how to service air out door unit and could not catch upwith any ,but your clip can turn a zero to hero , Thanks i leanrt a lot from this .hope to see more clips on fridge service .. tks friend
Thank you . There is more to come
Hi Dahen Zana , thanks for the swift reply , Do you have notes about the aircon servicing .
welcome . I have another video about test air conditioner capacitor
Now I understand. Guy who works and not talks
It's awesome. Thank you bro.
thank you sir
TH-cam.com/c/aaziztechnical
plz visit and subscribe a aziz technical TH-cam channel for HVAC and home appliances repairing video thanks ♥️
super vedio good explain i like this
thank you sir i hope it's helpful for you
Best Air conditioner video on youtube. I watch many to learn but this is by far the best for noobs like me than plans to do some DIY ac work
thank you sir i hope it's helpful for you
Hi, you did a very informative video for such a DIY process. I want to make my own pressure and vacuum motor as what you did using the refrigerator motor. 1) is there any specific capacity for that motor to use to pressurize and vacuum my 2 tons split AC? 2) I saw the motor has "T" handle on the top. Did you weld it as it is or you separated the tank first since I also noticed that there is welding around the middle of the tank motor. Thanks buddy.
Thank you and sorry for late- for first question the motors name is (Danfus) from Denmark and about the capacity i am not sure and for second question yes i welding the (T) hand without open the compresor
Bsbsvxv
great job
das xosh bet sarkawtw bit
sopast dakam . bbura ka taxer walamm dawa
Good Sir Ji
Thank you
This one of the best videos i have come across thank you keep it up. But i heard you have to turn the cylinder upside down when you are charging
thank you sir, you have not to turn the cylinder upside down
At 0:20 seconds you opened some sort of valves with allen ranch. Do we always open these valves before charging refrigerant through the service valve? And don’t you have to close the valves with allen ranch after charging?
Great sir
Thank you sir
Nice job ,mr
Thank you sir
gostei muito do voço trabalho quero aprender mais
Obrigado, eu vou tentar
Wow - you are the man, thank you a lot - easy, specific, pragmatic - the way I like!
Very very good go ahead 😍
thank you
You must give the gas with scales. The pressure can fool you. The pressure varies according to the air temperature. Greetings from Turkey 🇹🇷
Beğenin la
Thank you for your information
Very nice video
Thanks
you welcome sir
AC compressor use it as a vacuum pump we used to use them to blow up bike tires back in the old days
Good work
thanks a lot very useful .
Thank you
Ola amigo qual e o compresso que vc usa para fazer o vacua deste agradeco
an excellent vedeo
Thank you
This is very helpful to me my is low on refrigerant
Hi, this is better that twice vacuum,after first vacuum charge a moment gas R22 ,to degree become above zero, second vacuum , and after full gas R22.Also that is better vacuum with two stage vacuum pump.good luck.
Коллега, используйте краны на шлангах, после ваккумирования, продувать шланг надо не закрывая вентиль на баллоне, будете иметь повышенное давление конденсации!
Спасибо за информацию