What is the Difference between a Contactor and Reversing Contactor and How do They Work?

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 มี.ค. 2015
  • Wiring up a contactor and reversing contactor presented by Katie Nyberg for Galco TV. Buy the items featured in this video at 800-337-1720 or visit: www.galco.com/get/Contactors?s...
    Check out this video to find out the difference between a contactor and a reversing contactor. You will also learn how it works and see how to wire up contactors to be operated by a pushbutton. Contactors can be used to start or stop a motor. With forward and reversing contactors the motor can be run bi-directional in a clockwise or counter clockwise direction.
    Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/email/
    Connect with us!
    plus.google.com/+GalcoIndustrial
    / galcoindustrial
    / galcoindustrial
    / galcoindustrial
    / galco-industrial-elect...
    Don't forget to like and comment on this video, and subscribe to our channel!
    Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
    www.galco.com/safety
    With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
    GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.
    LEGAL DISCLAIMER:
    While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warranties of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 41

  • @tabletavina4615
    @tabletavina4615 8 ปีที่แล้ว +7

    im learning a lot from this channel, love the way she explains it very clear and precise, no unnessesary talk thanks

  • @JulesBartow
    @JulesBartow 7 ปีที่แล้ว +3

    Great intro to contactor reversing kits.

  • @kiflayzenebe2215
    @kiflayzenebe2215 6 ปีที่แล้ว +1

    Thanks for explaining.

  • @subramanian6857
    @subramanian6857 7 ปีที่แล้ว +3

    I love this channel thank u

  • @ryanwilson3049
    @ryanwilson3049 3 ปีที่แล้ว +1

    Thank you for this!

  • @nawazmatloobmuhal366
    @nawazmatloobmuhal366 8 ปีที่แล้ว +1

    you are great i learn lot things from you thank you

  • @nickhess5327
    @nickhess5327 ปีที่แล้ว +1

    Thank you this was a great video.

  • @edmondchampagne1199
    @edmondchampagne1199 4 ปีที่แล้ว +1

    awesome video thank you

  • @AdnanAlkalali
    @AdnanAlkalali 8 ปีที่แล้ว +1

    very help full Chanel thanks

  • @walyaldeenabdallah7679
    @walyaldeenabdallah7679 3 ปีที่แล้ว +1

    I'm thankful for you

  • @janetsterno
    @janetsterno 7 ปีที่แล้ว +3

    I always like the candy bar Galco sends in the box with the product. Galco is much better than most others!

  • @minyemekolani4974
    @minyemekolani4974 6 ปีที่แล้ว +1

    Nice, good video

  • @nemojac
    @nemojac 8 ปีที่แล้ว +1

    very nice,any idea how to wire up a three phase motor operating Ridder type screw 1-10 ratio worm gear running contentiously back and forward through a limit switch and on timer?,nice informative presentation,

  • @user-cy2pz4bj4w
    @user-cy2pz4bj4w 8 ปีที่แล้ว +1

    Very nice explanation

  • @abdulqadir150
    @abdulqadir150 5 ปีที่แล้ว +1

    I like it

  • @ashfaqali2681
    @ashfaqali2681 7 ปีที่แล้ว

    nice

  • @youssefmamouun7713
    @youssefmamouun7713 3 ปีที่แล้ว

    Nice

  • @youssefmamouun7713
    @youssefmamouun7713 3 ปีที่แล้ว +1

    Can you make a video explaining how the mechanical interlock works in a more practical way??

  • @erickjuma6211
    @erickjuma6211 7 ปีที่แล้ว +1

    can you please show us how to connect a contractor to automatic change over switch for a generator. .?

  • @niggisgaming1637
    @niggisgaming1637 4 ปีที่แล้ว +1

    Thx i learn too much

  • @mardiasultanamoni6060
    @mardiasultanamoni6060 5 ปีที่แล้ว

    gd job

  • @user-tp1zg9id6u
    @user-tp1zg9id6u 7 ปีที่แล้ว +1

    هvery good

  • @Froggability
    @Froggability 3 ปีที่แล้ว +1

    Should have included an electrical interlock as well.

  • @kyngdavid6246
    @kyngdavid6246 8 ปีที่แล้ว +1

    do i need to Stop the motor first with the same switch that i start it with in order to use the other switch to do the reverse

    • @TheRemotejon
      @TheRemotejon 8 ปีที่แล้ว +2

      +Keyoke Andson This is wired to only run the motor when the buttons are held down. Allow motor to stop before running it the other way :)

    • @davesoutdooradventures5523
      @davesoutdooradventures5523 8 ปีที่แล้ว +1

      +Keyoke Andson it is good practice to let the motor stop first, reversing it while in motion can cause the reduction of the motors life and overloading the circuit protection, if not more serious problems.

  • @JamaalMadan
    @JamaalMadan 5 ปีที่แล้ว

    I am in africa thuns for teaching yuo are profisional

  • @marnieorioque341
    @marnieorioque341 7 ปีที่แล้ว +1

    base on your demonstration you have only stop and start push button...how do you operate in reverse or forward the motor if only stop and start push button switch that you will use?its better to use a 3pole selector switch or stop,reverse,forward push button,to control the motor in forward reverse operation and to stop the motor manually.

  • @5822huron
    @5822huron 6 ปีที่แล้ว

    I use to build these at Siemens

  • @tonymaraj1564
    @tonymaraj1564 4 ปีที่แล้ว +1

    How do you wire a 3 phase motor to a single phase .

    • @Froggability
      @Froggability 3 ปีที่แล้ว

      Use an inverter or VFD designed for that purpose

  • @andreaschristodoulou4274
    @andreaschristodoulou4274 6 ปีที่แล้ว +2

    Actually there is not any difference on contactors, the difference its on the wiring setup

  • @YazidSG
    @YazidSG 8 ปีที่แล้ว +1

    Is this a star connection? I thought there should be at least 3 contactors to run a motor, main with overload, star and delta?Hmm..

    • @GalcoIndustrial
      @GalcoIndustrial  8 ปีที่แล้ว +2

      This video is for a single winding motor showing how to start it and how to reverse it using contactors. This video does not address the star-delta motor configuration. You are correct, for the star-delta configuration you need 3 contactors. The star-delta configuration would be used for either a two-speed motor or for a star start - delta run motor.

  • @bacjaz6741
    @bacjaz6741 7 ปีที่แล้ว

    so theres no wire connection to the interlock

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว

      No, this is a mechanical interlock only. However many installations will use both a mechanical and electrical interlock for double protection against energizing both contactors at the same time. With no interlock protection and both the contactors energized at same time it would put a short across the line and trip the supply breaker or blow fuses, NOT a desirable scenario, ok?