@@rajthiyagus4675 yes thermostat will automatically switch off the heating process and when temperature of water goes down which take time in summers the heating process will start again but only for upto 1 min depend upon different things , but you can say it will not going damage anything
ji drain bolt siraf panni drain karne ke kam aata hai or kuch ek geysers mai drain bolt ki jagaha hi a safety valve laga di jati hai or kuch mai don allage kagaye jate hai
Sir hamaara heater me garam paani ka oper ka pipe me paani nahi aathi pipe kolkar dega pipe sahi he baadme uska garam paani kaali kiya tanda pani ka lines iska kya problem bathayiye?
please problem thoda ache se bataye mujhe kuch bhi samajh mai nahi aaya upper ka pipe konsa gyser out let ya plastic pipe?? ya koi tap hai jo upper laga hai?
@@mujeebrhaman1194 aapki geyser ki outlet pipe under se jam hai , ho sakta hai usmai kachra ho ya phir calcium buildup ho gya ho, iske liye aapko geyser assembly open karni padegi or outlet pipe ko clean karna padega
safety valve is off, exit tap is closed and vacuum drain hole nothing comes !...waters still in.....! do i have to dig the vaccuum drain hole...i'm not sure, any suggestions sir....?
yes you can but then you have to attach a pipe to drain passage so that no water gets into electric parts which are in thermostat , if water gets in them , then in near future the rust will cause problems
bold?? bolt ki bat kar rahe hai? aagar niche ki cover plate jahan gyser element or baki chije lagti hai uski bat kar rahe hai to bo plate new bhi mil jati hai , jaha tak repair ki bat hai to aapko kisi ache welder se gar weling ke jariye repair karbani hogi
NRV non return valve means pani ka flow siraf ek hi direction mai hoga ,jese aap bta rahe hai ki ise ab inlet pipe mai laga rahe hai to agar aap mujhse puche to its useless (hosakta hai koi or bajase laga rahe ho , pani ka follow kam aata ho to shayad hi ye thode kam aata ho) maine aapko bataya that last comment mai ki pressure control valve hi ye sab kam kar deti hai rahi bat NRV valve ki to iska kam yehi hai ki pani back nahi aayega sirf ek hi direction mai flow hoga man lijiye ki pressure control valve fail hojaye to hot water tank mai hone ki bajha se pressure increase hota hai ese mai thoda pani (hot) inlet pipe ke jariye bapis aa sakta hai pressure release karne ke liye siraf esi condition mai hi NRV valve kam mai aayega or pani ko inlet pipe mai further janese rokega
Agar heating coil ka prob tut gaya to kya wire se thermostat se connect kar sakate hai? Konsa wire use kar sakte hai? Kya wire heat ho ke jal sakta hai? Please suggest. Thanks
main to yahi sala dunga ki aap new element hi daliye , agaar prob jahan tak plastic lagirehti hai vaha tak tut gayi hai to phir new element hi dalna sahi rahega or aggar thoda bahut prob ka hisa plastic se niche bacha hai to aap ek 1 mm ya 1.5 mm ki wire leke connect kar sakte hai
esa tab hota hai jab aapke reservoir tank mai pani na ho , esi problem dubara na ho iske liye tank ko empty na hone de ya phir jab tank empty ho to geyser ke tap ko na khole
@@abhinitj9276 re-install ke bad kya aapne geyser tank ki sari air nikali thi , output tap open karke water inlet open kiya tha ya output tap band tha?? fir bhi ye problem aapne aap solve ho jate hai 2-3 bar gyser use karne pe , agar abhi bhi ye problem aa rahi hai to pehle leakage check kare or phir inlet value pai jo safety value hai use bhi check kare ki bo sahi se tight hai ya nahi
@@SAIREPAIR sari air niakli thi aur bad m normal water ache se 1-2 bucket jane diya fir start kiya...uske 20 min bad jab tab open kiya tho air nikle lagi pressure se
as i check jaquar 10 lt geyser is in square shape and its build differently then normal geysers , you can drain it from inlet pipe ( if a non return valve is attached use that to drain it ) close the inlet valve and open the outlet tap then either use non-return valve or completely remove the inlet pipe and it will start draining , i don't have a jaquar geyser so can't say if it will drain completely or just a little water left in it after draining
kya aapne sari pipes bhi clean ki , agar haan to phir aapka reservoir tank ki height kam hogi isi liye flow kam hai, or kya aapne rubber gaskets bhi check ki jo outlet pipe mai lagi rehti hai??
aap inlet pipe ke jariye se kuch pani drain kar sakte hai sara nahi aagar light chali jaye to bhi jo hot water gyser mai hoga bo nikal jayega , haan agar resiorvoir tank mai pani khatam ho jaye to aap inlet pipe open karke or out let ke tab ko ON karke kafi pani bahar nikal sakte hai
ye ek safety valve hai , agar isse pani aaraha hai to iska matlab ye puncher ho chuki hai aapko ise replace karna padega , plus geyser ke baki components jese thermostat ko jarur check kar lijiye ga ki bo properly work kar raha hai ya nahi, kyuki ye valve kise reason se hi puncher hui hai
Hi sir how to check that my 25 ltr storage water Gyser stored water in it? Because my Gyser is not delivering water if I turn of inlet. Please reply soon
there is no visible way to check that , if you really want to know then you need to lift the geyser , check your inlet safety valve if its not too tight to stop the water inlet , plus open the plastic pipe from outlet pipe and check if the water is coming out after you open inlet valve or not, if still no water is coming out then the outlet pipe of geyser might be choked and you need to clean it
inlet pipe me jo valve hot hai use pressure control valve bhi kehte hai, iska kam cold water ke pressure ko control karne ka hota hai jab aap hot water outlet open karte ho to ye hi valve hota hai job cold water ekdam se tank mai fill na hojaye use rokta hai, kyuki aap jante hi honge ki cold water aggar jada matera mai hot water se mill gays to use bhi cold kardega bahut sare geyser mai is valve ko adjust karne ke liye spring loaded screw bhi diya hota hai jisse aap cold water ka fllow jada ya kam bhi kar sakte hai plus ye ek pressure relief valve ka kam bhi karta hai agar thermostat or baki ke safety system fail hojaye or tank mai water ka temperature kafi jada hojaye to is valve se automatic pani bahar nikalne lagta hai hope this info helps you
@@ijagtarsidhu sir agar cold water geyser mai nahi jayega to hot water bhahar kese aeyga , geyser ki inlet or outlet pipe dono geyser tank ke top tak hoti hai ,jese hi cold water geyser tank mai pahuchta hai output pipe water mai dubjati hai or phir bo pani niche tap se nikalta hai, is valve se aap siraf cold water ke pressure ko control karte hai naki use rokte hai , ye ek basic science hai ki hot water cold water ke upper tarta hai ,agar is valve ko pura open kardoge to cold water jaldi hot water mai mix hone lagega, isliye ise na jada tight kiya jata hai na jada lose
cut off kaha se ho raha hai manual reset se ya thermostat se, agar thermostat se to temperature thoda increase karde or agar manual reset se to uska bhi temperature increase karde, local thermostat or manual reset bese to 45 degree pe set rahte hai lekin koi surety nahi hoti ye hil bhi jate hai
@@SAIREPAIR lagta hai sahi ho gya hai .....syed thermostat ka clip body mein touch nhe hua tha isly problem aa rha tha Thanks for your support. Kya aap ACE Vaccum cleaner old se related meri help kar sakte han. M.N. 8825107970
What to do if there is no drain bolt? Kenstar Jacuzzi 15L has a vaccum release valve on outlet and pressure release valve at inlet. how do you drain the geyser in this case?
proper draining is done only from drain nuts , but if its not present then there will be a safety valve tube (plastic pipe coming down from center ) you need to open it and it will act as drain point
@@rgkoshie lol what you did , that valve is thread on to the geyser assembly , if just that broken then no worries you can get replacement easily but if broken from the geyser assembly then you need whole assembly to get replaced
let?? or LED if both of them sparking it could be because of many reasons like the loose connection of there wires inside the safety cover or there insulation (plastic) got striped and touching the body or other wires,or the most common due to the loose connection the socket it self either from outside or inside the power socket plus some times rust deposit on the terminals that cause both sparking and over heating of wires and switches
blot tuta hai to kisibhi gyser repair shop pe jaye baha se mil jayega , nahi ti uski jagha ek safety valve bhi laga sakte hai jesa choti pipe bali jagha mai laga hota hai
@@SAIREPAIR sir, drain bolt ke chudi wala part Tut kar , uske chudidar cover mein rah gya hai. Plastic ka valve bhi nikal gya hai. Repair wala gas welding se is ko parmanent band karne ko bol Raha hai. Jo baad mein shayad problem dega. Aap apna number share kare mein aap se baat karunga
@@onkorsidhu1143 aapka kehne ka matlab ki jo upper ki taraf plate hai jisme drain nut lagta hai bo tuta hai ?? fir to sir welding ek sasta option hai ya fir puri geyser assembly change hogi
agar water kam hot ho raha hai to iska element (rod) kharab ho chuki hai use replace kare or agar kam water bahar nikalne ki bhi problem hai to pipes ki o-rings change kare , kyuki kuch time bad mai bo hot water ki bajha se ful jati hai or water flow ko kam kar sakti hai
Since the Video is not taken with bright light we r unable to see all the bottom parts of the Geyser properly though he may be knowing more about all its parts&its functions.Really video taken in darkness did not show its real purpose to the viewers.Explanation may be alright.Tnx...
thank you for your valuable comment , yes this video is one of my earlier and at that time i don't know how to properly take shots and more over holding phone with one hand and working with another on the hanging geyser and standing on the chair was really challenging , i hope i got the time to make more good videos on geyser when i got time
PVC pipe jo hoti hai bo ek safety valve hai jese pressure cooker mai hoti hai ,agar thermostat or thermal cut out dono fail ho jaye or water bohot jada hot ho jaye to ye valve melt ho jata hai or hot water yaha se nikal jata hai
wiring ki video instant geyser pay bani hui hai chenale pe mil jayegi , usme bataya hua hai ki is tarha ke geyser ki wiring kaise hogi , time laga to ispe bhi alag se video bana dunga
@@adnanmushtaq124 sir aap chahe to geyser pura month one rakhe isse panni na ane ka koi link nahi hai, aap sabse pehle ye check kare ki inlet or out let pipe ke valve open hai phir inlet pipe ko open karke check kare ki panni ki supply aarahi hai ya nahi , kuch phassa to nahi hai pipe mai, geyser ka ek simply funda hai aagar ismai panni nahi daloge to panni bahar hahi aatta hai, agar iske bad bhi problem solve nahi hui to batana
ji bulkul agar by chance thoda bohot water thermostat pe girgaya ya strip wires area pe gir gaya to rust lagne ke chances bad jate hai jisse components jaldi kharab hone lagte hai
you mean drain the water from the valve area and not to open the bottom cover for draining??? then you must first know that this will not completely drain the tank
@@arunkumarmishra6197 depend karka hai ki leakage kahan se ho rahi hai , agar geyser assembly se ho rahi hai ya geyser element se to aap chahe to bina utare bhi theek karsakte hai per aapki arms pe kafi jor padega or aagar leakage geyser tank se hai to phir use repair karneke liye apko utarna hi padega
Thank you sir, because of your help, I removed all stored water from my water geaser today!
Glad I could help
Noobea
Very NEATLY EXPLAINED
Good explanation. Thank you sir.
you're welcome
Thank you sir
My problem is solve
Thank you very much.. ur video Is very helpful
Good video, fruitful information
Nice information help me to empty my geyser 🙏🙏
Very helpful video thank you
You're welcome
Is there any problem ? If we don't off power switch last 5hours. Does It affect or damage any parts
no it will not damage anything
@@SAIREPAIR Mmm K bro. It Mean's Automatically It will be off and Manage ?
@@rajthiyagus4675 yes thermostat will automatically switch off the heating process and when temperature of water goes down which take time in summers the heating process will start again but only for upto 1 min depend upon different things , but you can say it will not going damage anything
@@SAIREPAIR Hmmm kkk Bro .Tqq
Does the water in the tank of geyser come out completely by this process or some water remains in the tank?
yes completely
@@SAIREPAIR Is it possible to clean the tank of installed geyser. If yes how?
Thanx for the response.
@@sheshsharma6988 sorry , i was not around to reply , yes its possible to clean the tank by just removing the geyser element
Thankyou very much for your reply & response.
sir inalsa k gyser mein wo bolt ni jo last mein aapne khola khali karne k liye...plz reply soon...waiting
plz call62843661195
@@abhipaul4979 drain bolt?? nahi hai ya side pipe bala?? agar gyser 2lt bala hai to nahi hoga but mostly bade gysers mai drain bolt hota hi hai??
Sir mere me bhi nhi h please call me 8419957402
Sir is ka outlet open rakhne hai ya close
close rakhiye ya open koi jada phark nahi hai
Thanks, it really helped.
drain bolt 11no ka or kya kaam hota h iska please bataye sir
ji drain bolt siraf panni drain karne ke kam aata hai or kuch ek geysers mai drain bolt ki jagaha hi a safety valve laga di jati hai or kuch mai don allage kagaye jate hai
Sir thanks for informing us
Sir hamaara heater me garam paani ka oper ka pipe me paani nahi aathi pipe kolkar dega pipe sahi he baadme uska garam paani kaali kiya tanda pani ka lines iska kya problem bathayiye?
please problem thoda ache se bataye mujhe kuch bhi samajh mai nahi aaya upper ka pipe konsa gyser out let ya plastic pipe?? ya koi tap hai jo upper laga hai?
@@SAIREPAIR geeser ka outl et pipe nahi aathi
@@mujeebrhaman1194 aapki geyser ki outlet pipe under se jam hai , ho sakta hai usmai kachra ho ya phir calcium buildup ho gya ho, iske liye aapko geyser assembly open karni padegi or outlet pipe ko clean karna padega
@@SAIREPAIR pipe line open kar saktha he
@@mujeebrhaman1194 nahi pura geyser assembly open hoti hai, jo nichese sides pe nut dikhte he unsab ko open karke assmbley open ho jati hai
Pls guide me how to fix wire in bajaj majesty 25 ltr geyser 2009 model
you mean how to connect wires ?? , there is a wiring video on instant geyser , you can do the wiring exact same way following that video
safety valve is off, exit tap is closed and vacuum drain hole nothing comes !...waters still in.....! do i have to dig the vaccuum drain hole...i'm not sure, any suggestions sir....?
well in this situation open the exit tap and close the inlet one
Why thermostat are to be removed
Can i directly open nut ?
yes you can but then you have to attach a pipe to drain passage so that no water gets into electric parts which are in thermostat , if water gets in them , then in near future the rust will cause problems
hi sir mere gyser ka plate crack hai bold ke side se to repair ho sakat hai kay
bold?? bolt ki bat kar rahe hai? aagar niche ki cover plate jahan gyser element or baki chije lagti hai uski bat kar rahe hai to bo plate new bhi mil jati hai , jaha tak repair ki bat hai to aapko kisi ache welder se gar weling ke jariye repair karbani hogi
Hello sir, ab new geyser mei Hume inlet pipe mei Alag se nrv valve lagana padta hai uska kya kaam hota hai sir please please bataye
NRV non return valve means pani ka flow siraf ek hi direction mai hoga ,jese aap bta rahe hai ki ise ab inlet pipe mai laga rahe hai to agar aap mujhse puche to its useless (hosakta hai koi or bajase laga rahe ho , pani ka follow kam aata ho to shayad hi ye thode kam aata ho) maine aapko bataya that last comment mai ki pressure control valve hi ye sab kam kar deti hai
rahi bat NRV valve ki to iska kam yehi hai ki pani back nahi aayega sirf ek hi direction mai flow hoga
man lijiye ki pressure control valve fail hojaye to hot water tank mai hone ki bajha se pressure increase hota hai ese mai thoda pani (hot) inlet pipe ke jariye bapis aa sakta hai pressure release karne ke liye siraf esi condition mai hi NRV valve kam mai aayega or pani ko inlet pipe mai further janese rokega
Aus nrv ka kaam hoota hai ki woh paani wapis naa choode.
The Nrv we install in inlet pipe simply stops the water that goes back.
@@firdousrather8311 thank you for sharing your knowledge
@@SAIREPAIR sir itz my pleasure
gysor me paani 2-3 saal se bhra rhe to koi dikkt bhi hoga??
koi dikkat nahi hogi
Agar heating coil ka prob tut gaya to kya wire se thermostat se connect kar sakate hai? Konsa wire use kar sakte hai? Kya wire heat ho ke jal sakta hai? Please suggest. Thanks
main to yahi sala dunga ki aap new element hi daliye , agaar prob jahan tak plastic lagirehti hai vaha tak tut gayi hai to phir new element hi dalna sahi rahega or aggar thoda bahut prob ka hisa plastic se niche bacha hai to aap ek 1 mm ya 1.5 mm ki wire leke connect kar sakte hai
@@SAIREPAIR thanks lot for advice. Bahut dhanyawad.,🙏🙏
good job sir
thank you sir
Sir agar mai safety valve khol du or outlet v khol du to kya outlet se pani ayega??
ji aayega lekin isse gyser puri tarha se drain nahi hoga
ji aayega lekin isse gyser puri tarha se drain nahi hoga
Thank you sir
It was indeed a good vedio. Please try to focus your Camera, it was shaking badly.
thank you for pointing out, i'll try my best
Sir geyser me air pressure bana raha usks solutions bataye ..tap open krne p pressure se air nikal rhi h
esa tab hota hai jab aapke reservoir tank mai pani na ho , esi problem dubara na ho iske liye tank ko empty na hone de ya phir jab tank empty ho to geyser ke tap ko na khole
@@SAIREPAIR tank b full tha sir.. n tap b phele normal chal raha the... Coil chnge ki...fir reinstall ke bad ye problem aarhi h
@@abhinitj9276 re-install ke bad kya aapne geyser tank ki sari air nikali thi , output tap open karke water inlet open kiya tha ya output tap band tha?? fir bhi ye problem aapne aap solve ho jate hai 2-3 bar gyser use karne pe , agar abhi bhi ye problem aa rahi hai to pehle leakage check kare or phir inlet value pai jo safety value hai use bhi check kare ki bo sahi se tight hai ya nahi
@@SAIREPAIR sari air niakli thi aur bad m normal water ache se 1-2 bucket jane diya fir start kiya...uske 20 min bad jab tab open kiya tho air nikle lagi pressure se
@@SAIREPAIR aur jo inlet pipe thi us se b noise aaraha tha popping ka
Heat water inlet se back pipe me ho ja rha h kya kare
inlet pipe mai kahi lekage hogi tabhi esa hoga , ya jo safety valve lagi hai vo jada open hogi ya kharab hogi
Sir gyser leakage h...assembly ka price kya rhta h
500 se 1000 plus tak milti hai price quality , geyser capacity pe depend karta hai
Please let us inform how to drain water from jaquar geyser 10litre
as i check jaquar 10 lt geyser is in square shape and its build differently then normal geysers , you can drain it from inlet pipe ( if a non return valve is attached use that to drain it ) close the inlet valve and open the outlet tap then either use non-return valve or completely remove the inlet pipe and it will start draining , i don't have a jaquar geyser so can't say if it will drain completely or just a little water left in it after draining
Sir maine poraa clean kiya khol k lekan fr v pani km a raha hai
kya aapne sari pipes bhi clean ki , agar haan to phir aapka reservoir tank ki height kam hogi isi liye flow kam hai, or kya aapne rubber gaskets bhi check ki jo outlet pipe mai lagi rehti hai??
Agar geyser bolt replace karna ho kya karein
kisi bhi geyser repair shop pe mil jayega
Thankyou sir
you're welcome
kya inlet pipe aur outlet pipe ko kholke geyser drain nhi hoga kya...
kabhi geyser mein grm pani hota hia, pwr chalajata hai, to kya input thanda pani band karke, bas geyser se garm pani kaise nikale... inlet aur outlet pipe kholke pani kue nhi niklta
aap inlet pipe ke jariye se kuch pani drain kar sakte hai sara nahi
aagar light chali jaye to bhi jo hot water gyser mai hoga bo nikal jayega , haan agar resiorvoir tank mai pani khatam ho jaye to aap inlet pipe open karke or out let ke tab ko ON karke kafi pani bahar nikal sakte hai
Rubber tube vale pipe se paani as Raha h.. us pipe Ka kya function h
ye ek safety valve hai , agar isse pani aaraha hai to iska matlab ye puncher ho chuki hai aapko ise replace karna padega , plus geyser ke baki components jese thermostat ko jarur check kar lijiye ga ki bo properly work kar raha hai ya nahi, kyuki ye valve kise reason se hi puncher hui hai
Thanks!
you're welcome
Thank you 😊
Hi sir how to check that my 25 ltr storage water Gyser stored water in it? Because my Gyser is not delivering water if I turn of inlet. Please reply soon
there is no visible way to check that , if you really want to know then you need to lift the geyser , check your inlet safety valve if its not too tight to stop the water inlet , plus open the plastic pipe from outlet pipe and check if the water is coming out after you open inlet valve or not, if still no water is coming out then the outlet pipe of geyser might be choked and you need to clean it
Hello sir, is geyser k inlet pipe me Jo valve hota hai uska kya naam hai aur uska kya kaam hota hai sir please please please please aaj hi bataye
inlet pipe me jo valve hot hai use pressure control valve bhi kehte hai, iska kam cold water ke pressure ko control karne ka hota hai jab aap hot water outlet open karte ho to ye hi valve hota hai job cold water ekdam se tank mai fill na hojaye use rokta hai, kyuki aap jante hi honge ki cold water aggar jada matera mai hot water se mill gays to use bhi cold kardega
bahut sare geyser mai is valve ko adjust karne ke liye spring loaded screw bhi diya hota hai jisse aap cold water ka fllow jada ya kam bhi kar sakte hai
plus ye ek pressure relief valve ka kam bhi karta hai agar thermostat or baki ke safety system fail hojaye or tank mai water ka temperature kafi jada hojaye to is valve se automatic pani bahar nikalne lagta hai
hope this info helps you
@@ijagtarsidhu sir agar cold water geyser mai nahi jayega to hot water bhahar kese aeyga , geyser ki inlet or outlet pipe dono geyser tank ke top tak hoti hai ,jese hi cold water geyser tank mai pahuchta hai output pipe water mai dubjati hai or phir bo pani niche tap se nikalta hai, is valve se aap siraf cold water ke pressure ko control karte hai naki use rokte hai , ye ek basic science hai ki hot water cold water ke upper tarta hai ,agar is valve ko pura open kardoge to cold water jaldi hot water mai mix hone lagega, isliye ise na jada tight kiya jata hai na jada lose
@@ijagtarsidhu you welcome bro
Sir inlet se pani chodne k bad,,,outlet se pani kitni der me niklega,,,,
jese hi tank full hoke outlet pipe ke level tak pahunch jayega uskebad tap se pani ana shuru hojayega
Nice information...but Bhai ji aapko bhi dhyan dena cahiye ...ek led lamp ka wire tod diya aapne , ...😄
dayan se video dekhne ke liye dhanybad , us lam ki wire kafi pehle se tuti hui hai
Thermostat se water leak kar rha hai...kya karen
geyser assembly open karke leakage balli jaga pe brazing karbao ya phir puri geyser assembly change karo
@@SAIREPAIR Thanks for your suggestions
Informative
Thanks
you're welcome
Was helpful... Thank you
you welcome
Mera same geyser baar baar cut off ho ja rha hai jabki element, thermostat and manual reset sab naya lagya hun local ..... please batay ab kya kare
cut off kaha se ho raha hai manual reset se ya thermostat se, agar thermostat se to temperature thoda increase karde or agar manual reset se to uska bhi temperature increase karde, local thermostat or manual reset bese to 45 degree pe set rahte hai lekin koi surety nahi hoti ye hil bhi jate hai
@@SAIREPAIR lagta hai sahi ho gya hai .....syed thermostat ka clip body mein touch nhe hua tha isly problem aa rha tha Thanks for your support.
Kya aap ACE Vaccum cleaner old se related meri help kar sakte han. M.N. 8825107970
@@BirendraKumar-pm2bi sorry mere pass vacuum cleaner nahi hai is liye mujhe unke bare mai kuch knowledge nahi hai abhi may be in future
What to do if there is no drain bolt? Kenstar Jacuzzi 15L has a vaccum release valve on outlet and pressure release valve at inlet. how do you drain the geyser in this case?
proper draining is done only from drain nuts , but if its not present then there will be a safety valve tube (plastic pipe coming down from center ) you need to open it and it will act as drain point
@@SAIREPAIR I tried that and it broke :-(
@@rgkoshie lol what you did , that valve is thread on to the geyser assembly , if just that broken then no worries you can get replacement easily but if broken from the geyser assembly then you need whole assembly to get replaced
@@SAIREPAIR I used a 11 number spanner and turned and it broke... Does this mean I better buy a new geyser? :-(
@@rgkoshie well its totally upto you :p
Both the let are sparking.... Why
let?? or LED if both of them sparking it could be because of many reasons like the loose connection of there wires inside the safety cover or there insulation (plastic) got striped and touching the body or other wires,or the most common due to the loose connection the socket it self either from outside or inside the power socket plus some times rust deposit on the terminals that cause both sparking and over heating of wires and switches
Very good
Thanks
Drain bolt Tut gya- kya karen
blot tuta hai to kisibhi gyser repair shop pe jaye baha se mil jayega , nahi ti uski jagha ek safety valve bhi laga sakte hai jesa choti pipe bali jagha mai laga hota hai
@@SAIREPAIR sir, drain bolt ke chudi wala part Tut kar , uske chudidar cover mein rah gya hai. Plastic ka valve bhi nikal gya hai. Repair wala gas welding se is ko parmanent band karne ko bol Raha hai. Jo baad mein shayad problem dega. Aap apna number share kare mein aap se baat karunga
@@onkorsidhu1143 aapka kehne ka matlab ki jo upper ki taraf plate hai jisme drain nut lagta hai bo tuta hai ?? fir to sir welding ek sasta option hai ya fir puri geyser assembly change hogi
@@SAIREPAIR ok thanks Sir, par welding karwane ke baad - next time geyser ki safai ke liye paani kese nikalenge?
@@onkorsidhu1143 jo pipe lagi hai choti si use open karke water drain ho jayega , nahi to pir direct element hi open karna padega
Sir isme water hot water nhi ho raha hai aur kam aa rha hai to kya kre
agar water kam hot ho raha hai to iska element (rod) kharab ho chuki hai use replace kare or agar kam water bahar nikalne ki bhi problem hai to pipes ki o-rings change kare , kyuki kuch time bad mai bo hot water ki bajha se ful jati hai or water flow ko kam kar sakti hai
Itna khol khal krenge to mushkilen aa sakti hn koi asan tàriqa ho to btayen
sir complete drainage ese hi hoti hai or koi tarika nahi hai
Since the Video is not taken with bright light we r unable to see all the bottom parts of the Geyser properly though he may be knowing more about all its parts&its functions.Really video taken in darkness did not show its real purpose to the viewers.Explanation may be alright.Tnx...
thank you for your valuable comment , yes this video is one of my earlier and at that time i don't know how to properly take shots and more over holding phone with one hand and working with another on the hanging geyser and standing on the chair was really challenging , i hope i got the time to make more good videos on geyser when i got time
Geyser ke andar Ek Chhota Sa nikala Hua PVC ka pipe hota hai vah Kis Liye Hota Hai Iske bare mein Mujhe bataen
PVC pipe jo hoti hai bo ek safety valve hai jese pressure cooker mai hoti hai ,agar thermostat or thermal cut out dono fail ho jaye or water bohot jada hot ho jaye to ye valve melt ho jata hai or hot water yaha se nikal jata hai
Thermostate jaja lagta hai use hall se Pani kyo lik kar raha hai
भाई इसके wiring कैसे करेंगे??
wiring ki video instant geyser pay bani hui hai chenale pe mil jayegi , usme bataya hua hai ki is tarha ke geyser ki wiring kaise hogi , time laga to ispe bhi alag se video bana dunga
@@SAIREPAIR शुक्रिया भाई बना देंगे तो बेहतर होगा 👍
Nice job:aap ki voice in between kam ho jati hai
sorry for that , kam karte karte pata nahi chalta or mic dab jata hai
What is toll free number of wonder company
Gas kaise remove krege
gas?? ye electric geyser hai ismai gas use nahi hoti
SAI REPAIR mera geaser 1 din pura on rha ab paani ni aa rha kya kru
@@adnanmushtaq124 sir aap chahe to geyser pura month one rakhe isse panni na ane ka koi link nahi hai, aap sabse pehle ye check kare ki inlet or out let pipe ke valve open hai
phir inlet pipe ko open karke check kare ki panni ki supply aarahi hai ya nahi , kuch phassa to nahi hai pipe mai,
geyser ka ek simply funda hai aagar ismai panni nahi daloge to panni bahar hahi aatta hai, agar iske bad bhi problem solve nahi hui to batana
Thermostat nikaalne zaruri hain kya, water drain karne k lie?
ji bulkul agar by chance thoda bohot water thermostat pe girgaya ya strip wires area pe gir gaya to rust lagne ke chances bad jate hai jisse components jaldi kharab hone lagte hai
Thank you sir....
What to do if drain bolt thread broken how to fix
Sir drain water bolt nhi h
ok , to phir aapko purane tarike se hi pani nikalna padega , pehle sake wires ko hatade phir rod ko loose karke halka sa niche karke pani nikalne de
Ye toh bahoot tough hai
ji bilkul, old models mai to drain bolt bhi nahi hota that usbakt to direct element ki jagha se karna padta tha :p
Why dnt u open non return valve fully and blow air from mouth into inlet line water will come out no need for all this
you mean drain the water from the valve area and not to open the bottom cover for draining??? then you must first know that this will not completely drain the tank
Drain kyon kar rahe hai ?
geyser element change karne ke liye ya fir cleaning karne ke liye
@@SAIREPAIR
Kya water leakage bhi bina utare thik ho sakta hai ?
@@arunkumarmishra6197 depend karka hai ki leakage kahan se ho rahi hai , agar geyser assembly se ho rahi hai ya geyser element se to aap chahe to bina utare bhi theek karsakte hai per aapki arms pe kafi jor padega or aagar leakage geyser tank se hai to phir use repair karneke liye apko utarna hi padega
Thanks bro