  • @nplsevou
    @nplsevou 3 ปีที่แล้ว +1

    Sir, since 50% of load is transferred through connection and the gusset plates are provided on each flange why that 50% is not divided equally for each . In welded gusseted connection that 50% is again divided equally for each gusset. Why it is not done in this bolted gusset connection??

  • @sg7.......352
    @sg7.......352 ปีที่แล้ว

    The number of bolts provided
    How to provide them
    gusette flange and angle 24 bolts
    OR
    Gusette flange and angle 12 bolts
    Angle and base plate 12 bolts
    How to provide base plate bolts

  • @sg7.......352
    @sg7.......352 ปีที่แล้ว

    2.5 kb d t fu nominal bearing capacity
    Sir, thickness t
    When gusette plate is 16mm
    When Angle is 75×75×10
    So,
    t=16mm or 10mm