Daikin split ac indoor green light blinking || solution || daikin ac error code problems / part 1
ฝัง
- เผยแพร่เมื่อ 2 ก.พ. 2022
- daikin ac light blinking problem.
Daikin split ac indoor green light blinking
In this video we discuss about Daikin ac green light blinking . When Daikin ac green light blinking, it means ac have some issues. Daikin ac have self diagnosis feature. That issue we can see in error code.
First of all turn on the AC. When green led light started blinking the press cancel button and hod for 5 sec. We can see remote display switched.
Press cancel button again and again ac sounds a small beep when ac sounds a long beep then stop pressing button . Remote shows a code . This code tells us ac problem.
A1= INDOOR PCE DEFECTIVENESS
A5= FREEZE-UP PROTECTOR
A6= FAN MOTOR FAULT
C4= FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9= FAULTY SUCTION AIR TEMPERATURE SENSOIR
00 is not any error code.
part 2
• Daikin inverter ac err...
Reson of ice formation in split AC
• split AC में बर्फ क्यू...
How to check sensors and component of pcb
• मल्टीमीटर कैसे use करत...
Subscribe my channel
#certain_india
m.th-cam.com/users/results?sp=mAEA...
Follow me on instagram
/ certain_india
#daikin #airconditioner #inverterac #noninverterac #error #errorcode #subscribe
Very nice himashu bro..👍👍👎👍👍👍
Thanku kaafi help hui
Very Helping video
Thanks a lot brother for fixing my problem🙏
Thankyou 😊
good video thank you
Thank you
Best knowledge ❤ Ajay
Thanks bro thanks
Its a usefull information thanks dude
thankyou
Great work himanshu bhai
C9 error ko sahi krwane k kya charges lgte h
Thankyou sir
Nice bhai
This is very useful video for myself
Nice
Good
Offfoooooo...... 😁
C9 error code arha h toh display ka kitna price pad jayega bhai. Plz rply
Lagbhag 1.5 k
Cancel button dabane ke baad kuch bhi nhi ho rha hai kaise pta kare light blink continued ho rha h indoor me daikin ac hai
Voltas ac mein unit mein run mode led on hai phele nahi hoti thi woh kyun h
Display button se off kar do led
UO, UR, U2, UF error pe double beep aa raha hai, last season humne outer pcb theek karaya tha. Ab fir se vohi problem ho raha h. Kis vaje se pcb khara b hota h. Please bataye
Stabilizer lagwa leejiye
Sir mere pass diakin inverter split ac hai... Usme beep sound (jab on /off ya remote se kuch button dabate hai to beep sound bahut hi kam aa raha hai... Jo naye ac ka beep sound aata hai usase bahut kam aa raha hai... Solution kya hai
Display pcb repair ho jati hai bas uska buzzer change Kara do sound badh jayega
Beep sound nhi aa rhi kya vo bhi error h ?
Mera Daikin remote me 00 arah hay but thanda Nehi ho rehi hay ????
Bro Timer Lite Biking 3 time Kia Fault Ho skta Hy Power Off Kr K Ac On Kro Ho Jata Hy 15 Sy 20 mint Cooling Kry Ga Pir Timer Lite Billing krny LG jati Hy Or Outer Off Ho Jata Hy Plzz Guide tension me Hon Yr Koi Error beep b Ni Dy Rha
Sayad ac overload ho rha hai
Aap ye bataiye ac ki service huye kitne din ho gye hai...
Inverter ac hai ya normal..??
Sir Daikan split ac m continiuve green lifgt biling kar rhe h to keya karna h pl help me
Sabse pahle error ko check kar leejiye
Video me error ko check karna bataya gya hai
Sir display on krte hi Indore unit bnd ho ja rha or outdoor chal rha ...
Mere ac mein 2 green lights jal rahi hai ,kya error hai bhai, ek normal wali and dusri sath wali light bhi green hai
Nhi
ek hi green light hoti hai
Display pcb proper fix nhi hai bs isliye Aisha dikh rha hai .
C3.Arr kis ka h
daikin ac E8 error when temprature is low ac work fine and temprature is up than ac light start blinking
Remote theek hai aur AC theek chalta hai per remote Kam Nahin karta kya problem ho sakti hai dusre AC mein remote theek kam karta hai
Display pcb me problem ho sakti hai repair karwa leejiye ya use chenge karwa leejiye
What is the cost to fix error C4 PLZ REPLY
Iska coil sensor short ya open ho gya hoga...
Isko fix karne me 500 se 800 rs tk lag sakte hai... Depends on authorised service center price
Mene dikin inverter 2 ton ac fitting kiya 2 din complet cahal abhi usme remote se on karte he to flep opan ho raha or turant close ho jata he bhai kya problem hoga isme ?
Ac on hota hai ki nhi
ac band hori he kya
Mere kahne ka matlab hai jb ac on hoti hai tab green light jalti hai
Jab green light jalti rahti hai blower bhi chalta rhata hai fir bhi flap band ho jata hai kya
Sir aapka WhatsApp number possible ho to do muje bahoot halp chahiye aapki sir
Aap insta par aa jaiye
C9 solve karne ka approx kharcha ?
1000 se 1400 ke beech ho jana chahiye
Sir Mera Daikin inverter AC h 1.5 ton 3 star voltage problem ho rhi h output 200 voltage Ane ac cooling nhi krta hai
Kitna purana hai
Stabilizer use Karo agar voltage ki problem hai
Sirf 00 mein long beep aaya..matlab ki koi error nahi hai. But fir bhi kbhi kbhi green light blink karta hai..jab ac chal rha ho tab. Iska kya matlab hua
Ac agar acche se kam kar rha hai to koi problem nahi hai,
Agar kabhi light blink karti hai or cooling band ho Jaye tab ac ko check karwane ki jaroorat hai
fan moter ne chal rahi
Daikin AC ka indoor Blower Fan 1 min baad chalu ho raha hai machine on karne ka baad... What is the problem
Ac shi hai koi problem nahi hai
Daikin ac k Nye model me blower late start hota hai
@@certainIndia bhai new daikin 2022 model me temp 24 degree se niche kyun nhi jaa rha hai 1-2 hour hi speed me chalne ke baad bhi
any solution
Sir mera koi error toh show nhi kar raha h fir bhi swing sirf half down or up move kar raha hai.kya karu
Aisi problem me erro nhi aata h
Ek bar ac on karke flap ko manually hath se band kake ac ko off kar deejiye 1 min bad ac ko dobara on keejiye agar same problem aa rhi hai to jyadatar chance hai ki swing motor kharab ho
Isse cooling pr koi bhi effect nhi aayega bs aapka flap khula hona chahiye or Han iska koi error bhi nhi aata hai
Mera bhi daikin ac 4months Hua.....remote main off karne ka baad bhi flap off nehi hota hain .....keya karu....
Mere daikin ac kaam tho kar raha hai but beep bandh ho gaya hai, plz help
Ac ke display pcb me buzzer lga hota hai wo kharab ho gya hoga wo repair ho sakta hai ya ap chahe to display pcb change kar ke apne problem ka solution pa sakte hai, buzzer kharab hone se coolling par koi fark nhi padega.
C3 or C6 aa rha hai
Kya kare
Mere ac me pili lite biling Kar rahi hai 2 baar kiya problem hai
Nhi
Ec code ka kya matlab hai
himansu bhai kya aap se baat kar sakte hai
Han bilkul bhai
Sorry for late reply
Insta pr msg kar lo
Bhai abhi mene ac ki gas fill karwai thi lekin 3 -4 din ke baad ac 32 par set kar rakha hai lekin cooling 18 wali kar Raha hai lagataar thandi hawa AA Rahi hai 32 par bhi kya problem ho sakti hai ac wale se bola to pcb check karne ko bol Raha hai
Koi error code bhi nahi show ho Raha hai remote me
Or beep ki sound bhi aati thi ab nahi aa rahi
Ho sakta hai connection galat ho gye ho jisse outdoor lgatar chal rha hai
PCB ki relay bhi short ho sakti hai
Jo beep ki sound nhi aa rhi hai wo display pcb ka buzzer kharab hone ki wajah se hai.
Solution:-
Ek bar pcb check karwa lo sab theek ho Jana chahiye ...
Air senor cost pls
Market me 100 rupees ka mil jayega
What to do in case of A5 error
Indoor ke cooling coil sensor ke karan ye problem aa rhi hai
Kya karna hei. Woh bathiye
Beep sound aa hi nhi rha hai..fir error kaise check kare?
Pahle display pcb repair krwa leejiye ya change karwa leejiye... Sound aane lagegi
what is the meaning of F.L % code
Iska matlab aaka ac ab full load par chal rha hai....
Sir hamare daikin split ac mai beep sound off ho gyi hai ye on kaise hogi
Display pcb repair ya change kra leejiye
Repair ho jayegi ye sasta bhi padega
Koi sound nahi aa raha matlab..error nahi hai?
Iska matlab hai ki aapke ac ki display pcb ka buzzer kharab hai
sir green light blink kr rhi hai ac on hi nhi ho raha
Jab kabhi ac me green light blink Karti hai iska matlab hota hai ki ac me koi problem hai jiske karn ye on nhi hoga
Jab tk ki use theek na kiya jaye
Bhai green light nhi jal rha h AC work kr rha h
Led kharab ho gyi hogi
Ya display pcb apni jagah se hil gyi hogi
Compplent thi ki blor moter nahi chal rahi thi. New moter change kar di to ye problem Ane lagi
Sir idu ki moter on hoti hai aur kuchh secnd chalti hai..fir jb green light blinking hone lagti hai to motor bhi band ho jati hai. Non inverter AC hai Daikin .
PCB thik karwali tab bhi wohi problem hai..
Usi pcb pr dusre ac ki motor fasclacss chala kr dikha diya pcb repair karne wale ne ..
Aur new motor lagane pr dikat de rahi hai
Kiya kare is halat me... Solution please
Error ko check kro or batao kon sa error aa rha hai
@@certainIndia Aaj wo customer dusri motor laya ..aur wo lagi to Aaj chal gaya fasclacss ac...
Pehli motor miss mach hone ke karan hi nahi chal rahi thi
Bai f3 error inverter
@@javeethalikhan8576
Bhai compressor overheat ho rha h
Outdoor saaf karo, fan speed check kro,
Return gas pipe check kro
F3 aa rha errror?
Outdoor ko service kr deejiye
Outdoor ke sensors check kar leejiye
Display pe long time yellow light show hora hai ac off karne ke bad be
ye problem kaise solve hogi????
Sir achank hi green light blink krni start hogi aur check krne pe C9 pe long beep aya ab kya kre
Display pcb change kar do
@@certainIndia daikin k service center se krvaye ya bahr se approx khrcha?
@@Jsk0311 1400 ke aas pas
@@certainIndia poori pcb change me kitna khrcha hoga?
Indoor or display dono ka 6000 tk..
00 mein long beep ho to kya hoga
Ac me koi error nhi hai...
Bhaiya humare ac me light blinking hoti hai par kuch der baad ac chalne lag jata hai. Fir chalta rahega regular jab tak band na karo aur band karte hi fir same problem ho jati hai isme kya problem hai
Sir mere ac me short beep ki awaz aa rahi hai
Agar ac lagatar chal rha hai our thanda kar rha to koi problem nahi hai
@@certainIndia bhaiya pr start karte waqt start nahi hota light blink hoti hai fir apne aap Start ho jata hai fir off karo to fir start nahi hota fir light blink hone lagti hai. Ac wale ko bulaya to wo bol raha hai ki PCP kharab hai.lekin jab start hota hai to koi problem nahi hoti cooling bhi sahi hoti hai na awaz hoti hai na hi kuch aur problem aur ac to abhi Naya hi hai 2 saal hi hue par tolal 6 month hi chala hai
Ok sabse pahle error check Karo our batao kya error aa rha hai
Inverter AC Daikin E1 problem????
Check outdoor pcb connection, wire and attach part and sensors
Or
Outdoor pcb failure
C3 ka to bataya nai
cassette ac ka error hai
Water level ka error hai
E11 error stands for?
E1 hoga....???
@@certainIndia E11 he error hai
E11 central hai sir plz help
Outdoor unit working of Daikin inverter AC, Inside unit Led Blinking continuously, error code 04 with high beep
Or U4 error code
Ek bar signal wire 3no. Wire ko check kr leejiye wo problem kr rhi hai
Mera ac indoor 10 min chalne ke baad off ho rha h or green light blink ho rhi h baar baar please reply me m apko paytm se paise bhi bhej dunga
Sir sabse pahle error code check kar leejiye
Error check karne ke liye remote ko ac ke samne karke cancel button ko kuch Samy tk hold rakhiye lagbhag 5 second ke bad aapko ac se long beep aayegi uske bad cancel button ko bar bar press keejiye jb tk next long beep na baje jb long beep aa jaye to jo no aapke remote screen pr dikhai de wahi error hai
Jo error aa rha hai wo mujhe bta deejiye
Ac remote को respond नहीं कर raha kya karein?
Aap remote ki led light ko mobile ke camera me dekh sakte hai
Jab remote remote shi hoga to remote ki button dabane par LED glow karegi
Agar aapka remote shi hai us condition me ac ki display problem kar rhi hogi
Aap use repair ya change karwa sakte hai
@@certainIndia yes remote ki led light glow कर रही है, ac service karane k baad remote को response नहीं कर रहा. Ac par on off button se hi chal रहा hai
Display problem hai
Sensor par Pani Jane ki wajah se Aisha hua hai
A1 beep long error
Indoor pcb problem hai
Change hogi
Banane ka bahut hi kam chance hai
Cancel button long press karne pe kuch nahi hua Kyu?
Remote pr 00 likh kar aaya hoga
Nhi aaya
Ab kya kru
Original remote nhi h... Tb bhj ye technique work kregi?
00 code long beep , green light linking , also yellow light bhi beech beech mein jalti hai
00 koi error nahi hai
Mere me koi long beep nai aarha or fir bhi green light blinking hori h
@@Dipsbajaj apka ac thik kiya apne ?
Mera bhi same to same huya hain.
Kuch solution Mila apko ?
Plzs reply
Vai apke ac ko thik kiya hai ?
Mera bhi same to same prblm hain solution mila apko ?? Plzs reply
Facing same problem 00 code
I Have Daikin Ac Having Issue Showing Time Light And Outdoor Not Getting Start
Your ac's timer is on, turn off the timer.
Ac on rhta h pr chlta hi ni h
Kya aapne error ko check kiya
@@certainIndia nii
00 pe long beep aa raha hai
Ye koi error nhi hai
@@certainIndia ok sir
@@certainIndia 00 pe long beep aa raha hai.. lekin green light fir bhi blink ho Rahi hai.. aur kisi error code pe long beep nahin ho Rahi.. sensor ko reset kaise karen?
Agar green light blink kar rhi hi or ac thanda nhi kar rha hai iska matl. Koi problem hai
Aapko ek bar service center se contact karna chahiye
94 code kya hai bhai
Ac kon si hai
@@certainIndia Daikin inverter
Jo connecting wire 1 aur 2 wire hai wo check kr lo agar wo sahi hai to fan unit ki pcb me problem hai
@@certainIndia ac bara bar chal raha hai agar wiring galat hoti tao ac chalo nh hota bas earth nh hai kya ya wajha ho sakti hai
Han ho sakti hai lakin agar ac pahle se Chal rh hai to Bina earth ke pahle bhi nhi chalta
Dain ac ki inverter ac me earth ka bhi error aata hi
C9 ERROR CODE KAISE THIK HOGA????
Display pcb change kar do
Sir apka Number dijiye Plz. Video call karna hai iska solution chaoye hai ac wala 3000₹ maang raha hai
7355078433
Sir app ka number kya h
Insta par call kar sakte hai
C3 arr
Please reply
Room air
Floting volve check kar lo......
Ya fir drain motor nhi chal rhi hogi