Plinth Beam Load Calculation (Fixed and Simply Supported Support)

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ม.ค. 2025

ความคิดเห็น • 26

  • @omarabdullah9969
    @omarabdullah9969 2 ปีที่แล้ว

    Thank you very much ma'am...you are a great teacher..i got cleared all doubt about this topic....pls continue teaching...love from bangladesh

  • @Vasanth_TP
    @Vasanth_TP 3 ปีที่แล้ว +1

    looking forward to the next video.

  • @dilmahanmahato8766
    @dilmahanmahato8766 3 ปีที่แล้ว +1

    Nice explanation, madam.

  • @josephfernandes988
    @josephfernandes988 9 หลายเดือนก่อน

    Informative Video

  • @christiankalombo2621
    @christiankalombo2621 3 ปีที่แล้ว +1

    Thank you very much. It is not likely that we know and can do every single thing, we still need someone to refresh our memory

  • @rajendiranp122
    @rajendiranp122 2 ปีที่แล้ว

    thnx for your good job madam

  • @akshaybangad1174
    @akshaybangad1174 2 หลายเดือนก่อน

    nice one... can you please mention the clause or book from where you got the formula for depth , d= span/1%

  • @nizamali7027
    @nizamali7027 10 หลายเดือนก่อน

    Good class thank you

  • @onestructuredesign8043
    @onestructuredesign8043 3 ปีที่แล้ว

    Thank you teacher 🔥🔥

  • @er.k.suryakumaran2309
    @er.k.suryakumaran2309 3 ปีที่แล้ว

    Useful information after that academics..,thank u

  • @kennyomega8937
    @kennyomega8937 2 ปีที่แล้ว

    Nice

  • @kbasit65
    @kbasit65 ปีที่แล้ว

    Hi there, we did a full basement and on a ground floor we will parking two cars on top of basement. Is it safe to do so ? we give two columns and a beam.

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 3 ปีที่แล้ว +1

    Fine

  • @nizamali7027
    @nizamali7027 10 หลายเดือนก่อน

    If you show cross section of plinth beam it will be good for understanding

  • @RakeshKumar-ss9qm
    @RakeshKumar-ss9qm 3 ปีที่แล้ว

    Thank you madam.

  • @danishaman291
    @danishaman291 3 ปีที่แล้ว

    Hi. Can we provide only plinth beam without column in the house? Like in load bearing wall construction can we provide plinth beam what is the advantage and load calc in this case?

    • @laxminarasimhatutorials666
      @laxminarasimhatutorials666  3 ปีที่แล้ว +1

      We can provide without column, if the span is large, then you have to provide column

    • @danishaman291
      @danishaman291 3 ปีที่แล้ว

      @@laxminarasimhatutorials666 For how long span, what is the advantage of giving plinth beam in load bearing wall construction and how will distributed to foundation?

    • @laxminarasimhatutorials666
      @laxminarasimhatutorials666  3 ปีที่แล้ว +2

      Above 12 feet you can provide column.
      If only plinth beam is provided without column, there may be problems of sinking of foundation. If you provide column, it will give support to the beam and load will distribute from column to foundation

  • @devanandroutpahelaamaatipa7700
    @devanandroutpahelaamaatipa7700 3 ปีที่แล้ว

    Will u explain 16mm two bar in top and 16mm two bar in bottom is more strength then 12 mm three bar in top and 12mm three bar in bottom

    • @laxminarasimhatutorials666
      @laxminarasimhatutorials666  3 ปีที่แล้ว +1

      2,#16 area is 402mm2, that of 3,#12 area is 339mm2, Hence strength is more in 16mm dia, depend upon load in beam or column, accordingly bars will be provided

  • @abhisheklad3951
    @abhisheklad3951 3 ปีที่แล้ว

    B1 beam mei beach me column hota to calculations me kya changes aate??

  • @snrajtech668
    @snrajtech668 2 ปีที่แล้ว

    column load how you add in this load calculation

    • @shruthia8522
      @shruthia8522 2 ปีที่แล้ว

      That part I will explain in other videos later