Machine Expert - Selected target system is different from the connected device. Version mismatch

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 มิ.ย. 2024
  • EcoStruxure Machine Expert Training - M11.1 Selected target system is different from the connected device. Version mismatch
    Firmware compatibility: • Modicon M241 M251 - Co...
    _M6.2 Firmware via SD Card for M262: • EcoStruxure Machine Ex...
    _M6.3 Firmware via SD Card for M241/M251 : • EcoStruxure Machine Ex...
    _M6.4 Firmware via USB/Ethernet for M262 : • EcoStruxure Machine Ex...
    _M6.5 Firmware via USB/Ethernet for M241/M251 : • EcoStruxure Machine Ex...
    The software to program the Modicon M241, M251, M258, M262 and PacDrive MotionController is EcoStruxure Machine Expert (former SoMachine / SoMachine Motion).
    For the Modicon M258 the version required to use the software is the EcoStruxure Machine Expert v1.2.x.
    The version of EcoStruxure Machine Expert v2.x does not include the M258 in the hardware list.
    In order to install this software you need to download "Schneider Electric Software Installer" from the next link:
    download.schneider-electric.c...
    Then you should be able to install EcoStruxure Machine Expert.
    The software EcoStruxure Machine Expert has a Free version after the 42 days trial, please check pages 14 and 16 for more information for the free version limitations:
    download.schneider-electric.c...
    The user that wants to use this software needs to have an account in our License Portal in order to register the software:
    www.se.com/ww/sites/corporate...
    In the past the software was SoMachine and the latest version of this software was the SoMachine V4.3 SP2.
    The reference for SoMachine is the SOMNACS43:
    www.se.com/ww/en/product/SOMN...
    The firmware version of the Modicon M241, M251 and M258 for PLC programmed in SoMachine starts in v4.x.x.x and in Machine expert it starts in v5.x.x.x.
    In order to program the Modicon M241, M251, M258, M262 you can use a miniUSB cable (TCSXCNAMUM3P or BMXXCAUSBH018) , SD Card (not M258 this one use pen drive) or an ethernet cable (depend on the version).
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 3

  • @hakimchabane746
    @hakimchabane746 13 วันที่ผ่านมา +1

    Traduire du texte avec votre appareil photo
    another question if you allow, on PLC M251 I tried to create a routing table but always there is an error network Mask and network destination is not valid, Can you give us an exemple ?
    Thank you so much

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  11 วันที่ผ่านมา +1

      Hi there! I believe I have some examples some where but I need to check if they are mine. In order to access to some devices you will need to add that route also in the laptop otherwise it will not work , I did test that before the table routing I will need to play with again. If you get many errors and you think the addresses are correct I advice to contact the technical support in your country

    • @hakimchabane746
      @hakimchabane746 6 วันที่ผ่านมา

      @@LeTomasAHUMADA
      Thank you for your réponse,I have équipments connected to ETH2 at adresse 192..... and SCADA will connect it to ETH1 10.....
      but when I add the routing table there is Always an error that appears( Route 10... and local network cannot overlap)