    In this video you will learn how to fix warnings in etabs
    Check warnings in etabs
    check warnings error
    Fix check warnings in etabs
    How to remove model warnings in etabs
    How to get rid of warnings in etabs
    How to remove model warnings in etabs
    Remove warnings in Etabs
    Fix etabs model warnings
    Line load transfer error
    area load transfer error
    shell overlap error
    beam over lap error
    etabs warning area load transfer,
    etabs warning too close,
    etabs warning messages,
    etabs warning check meshing,
    etabs warning check meshing reduction,
    etabs warning zero ritz starting vector eliminated,
    etabs warning horizontal rigid diaphragm,
    etabs warning no ritz modes were found,
    etabs warning are too close,
    etabs warning line load is not transferred,
    check meshing warning etabs
    #etabs #engineering #design

ความคิดเห็น • 53

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  4 ปีที่แล้ว +1

    Watch "Remove check warnings in and fix errors in ETABS model"

    • @owaissofi5321
      @owaissofi5321 4 ปีที่แล้ว

      Sir i have run the check model there is no warning

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      @@owaissofi5321 Thats a good thing .

    • @alexmusaddique_7864
      @alexmusaddique_7864 ปีที่แล้ว

      @@EngineeringLearningPlatform how to rectify this error please elaborate it ( F21 and B216 are too close )

  • @abdurahmanharitsfadillah1896
    @abdurahmanharitsfadillah1896 2 ปีที่แล้ว

    very helpful, thanks

  • @tariqnuman4087
    @tariqnuman4087 ปีที่แล้ว

    Very nice vedio.

  • @Penghuoth
    @Penghuoth 2 ปีที่แล้ว +2

    load case : solving linear stiffness from zero (unstressed) initial conditions
    how about this one??

  • @alikarim7027
    @alikarim7027 3 ปีที่แล้ว

    can you please make a video for the design of masonry brick wall in etabs ? i shall be very grateful for you

  • @touphikshaikh7860
    @touphikshaikh7860 3 ปีที่แล้ว

    Sir, After defining the material properties when we save the file it shows error saving and (file may be incomplete) please reply.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      We need to look into error, contact our team at facebook.com/engineeringlearningplatform

  • @pi_arjun
    @pi_arjun 2 ปีที่แล้ว

    Joint labels Storey 4, 30 and 30 are too close? What does it mean?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  2 ปีที่แล้ว

      Turn on joint visibility, see where it is occuring and redraw the elements which have those joints

  • @uniqueindian217
    @uniqueindian217 4 ปีที่แล้ว +1

    Sir plzzz make some videos on detailing plzz

  • @williamsentemtz9652
    @williamsentemtz9652 4 ปีที่แล้ว +1

    Sir, please upload some tutorials on steel connection design in RAM connection software

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว +1

      Thanks for request, Next video will be on steel deck design and then connection in a couple of days .

    • @williamsentemtz9652
      @williamsentemtz9652 4 ปีที่แล้ว

      @@EngineeringLearningPlatform Thank you for your kind response sir.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว +1

      @@williamsentemtz9652 Sure. Please share as much with your classmates, co-workers to encourage :) Have a good day!!

    • @williamsentemtz9652
      @williamsentemtz9652 4 ปีที่แล้ว

      @@EngineeringLearningPlatform yes sir so many students of our college are regular viewer of your youtube channel. And I also recommended my juniors to follow your tutorials.

  • @rehmanmatti
    @rehmanmatti 2 ปีที่แล้ว

    there is an error that comes in etabs for what i was here for
    that is Error no. 0, error cleaning numbers arrays.
    you can fix it by going to edit>relable all .
    cheers .

  • @jahedulalam566
    @jahedulalam566 3 ปีที่แล้ว

    How to remove a point that is in a grid line and this point is connected to the bottom floor when diaphragm. Now how can this point be deleted?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว +1

      As u mentioned it is on the edge of a n element, thus it cannot be deleted unless the connected element itself is deleted

    • @jahedulalam566
      @jahedulalam566 3 ปีที่แล้ว

      @@EngineeringLearningPlatform Thanks for your support.

  • @nafisfuadnipu693
    @nafisfuadnipu693 3 ปีที่แล้ว

    How to solve stair area load transfer?

  • @minaahmadzai9403
    @minaahmadzai9403 3 ปีที่แล้ว

    What to do with line load not transferred warning??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      There are different reasons, when the line is on a slab which is having none property, or slab is membrane and supporting the beam, or the line is disconnected from Structure .

    • @minaahmadzai9403
      @minaahmadzai9403 3 ปีที่แล้ว

      @@EngineeringLearningPlatform is there any easy way to connect lines?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      Use modify tool

  • @lifeline7673
    @lifeline7673 3 ปีที่แล้ว +1

    how to solve warning ralted to lime load not transfer ??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      It means the element slab or beam is somehow not transferring the load to the supporting members . Deleting and remodeling and re applying load may help

    • @lifeline7673
      @lifeline7673 3 ปีที่แล้ว

      @@EngineeringLearningPlatform i have assigned a none beam and assigned parapet load there now how can i delete beam?? If i delete it and redraw than load will gone which means combination will get affected??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว +1

      @@lifeline7673 for line load purpose, you need a beam, not a null line so define a section having properties of any minimal non zero stiffness (for instance 1"x1") dummy section intead of null line

    • @lifeline7673
      @lifeline7673 3 ปีที่แล้ว

      @@EngineeringLearningPlatform thankyou so much.it work!d

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      Welcome do checkout our professional courses
      www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7

  • @SaifulIslam-yh7fn
    @SaifulIslam-yh7fn 3 ปีที่แล้ว

    etabs warning zero ritz starting vector eliminated & etabs warning no ritz modes were found, ??????
    Where????

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      This occurs when there is abnormal modelling errors, one of which may be due to structure hanging in air (no supports assigned)

  • @arbazshaikh6771
    @arbazshaikh6771 3 ปีที่แล้ว

    Sir why we not model plinth beam in Etabs or any other software

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      Its not your choice . Doesn't affect the super Structure behavior mu h

    • @arbazshaikh6771
      @arbazshaikh6771 3 ปีที่แล้ว

      @@EngineeringLearningPlatform if i want to design plinth beam then what loading should I consider
      Or if I want to model plinth beam in Etabs how I applied soil pressure on beam
      And one more query when i analyzed my Etabs model with considering all stiffness modifiers and 1st storey I am getting very less bending moment then it's upper floor why sir
      And thank you for your time and help 😊❤️

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 ปีที่แล้ว

      @@arbazshaikh6771 For plinth beam design simply take wall load and apply on beam and design manually . As= Mu/4d . For second query it is very common that seismic moments increase with height .

    • @arbazshaikh6771
      @arbazshaikh6771 3 ปีที่แล้ว

      @@EngineeringLearningPlatform thank you so much sir

    • @arbazshaikh6771
      @arbazshaikh6771 3 ปีที่แล้ว

      You are very responsive I recommend your channel to my college colleagues and my friends

  • @owaissofi5321
    @owaissofi5321 4 ปีที่แล้ว

    Sir am not getting the results after running the analysis.. Can u help it out

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      Explain further

    • @owaissofi5321
      @owaissofi5321 4 ปีที่แล้ว

      @@EngineeringLearningPlatform sir as i run the analysis in my laptop it loads the analysis but the results and all doesn't show

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      @@owaissofi5321 Go to analyse tab and click on set load cases to run . See if it shows completed or not run

    • @owaissofi5321
      @owaissofi5321 4 ปีที่แล้ว

      @@EngineeringLearningPlatform sir it shows in status not run and in action it shows run

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      @@owaissofi5321 Your model is corrupted

  • @Lunaticboy9182
    @Lunaticboy9182 10 หลายเดือนก่อน

    Errors after importing files