HT Motor Protection || Relay Settings || HT Motor Protection faults Explanation | Hindi | Q&A |

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ส.ค. 2023
  • In this video we have discussed | HT Motor Protection | Protection against all faults || Relay settings of HT motor || In hindi language || So watch this video and gain electrical knowledge|| Also discussed electrical Interview questions related to this Topic ||
    What is the protection of electrical HT motor?
    What is HT and LT motor?
    Why is motor protection relay used?
    What is the function of 50 51 relay?
    Explain Relay Settings of HT motor Protection?
    Discuss all faults for HT motor Protection?
    what is thermal overload and it's Settings in Relay for HT motor?
    what is Short Circuit protection and it's Settings in Relay for HT motor
    what is Overcurrent Protection and it's Settings in Relay for HT motor
    what is Earth fault and it's Settings in Relay for HT motor
    what is Unbalance Protection and it's Settings in Relay for HT motor
    what is Differential protection and it's Settings in Relay for HT motor
    what is Bearing Protection and it's Settings in Relay for HT motor
    what is No of Starts and it's Settings in Relay for HT motor?
    Explain HT motor Protection against faults with ANSI code ?
    #electricalengineering
    #electricaljobs #electrician #electricalinterviewquestions #electrician_theory #powersystem #electrical #electricaltechnology #electricaltheory #switch_gear_protection #electricalmotor #electrical_engineering #electrical_engg_jobs #electrical_engineer #diploma_electrical_engineering_jobs #diploma_engineering #diplomajobs #electricalrelay #relays #relay #motors #
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 53

  • @parmarramesh9897
    @parmarramesh9897 8 หลายเดือนก่อน +2

    Great video for knowledge improvement & interview preparation thank you sir ji 🤗

  • @sanjeebbadaik2912
    @sanjeebbadaik2912 8 หลายเดือนก่อน +1

    The way of your explanation is too good sir, very helpful video, God bless you forever ❤

  • @surendrakverma555
    @surendrakverma555 10 หลายเดือนก่อน +2

    Excellent explanation Sir. Thanks 🙏🙏🙏🙏

  • @Kevin-ub3pt
    @Kevin-ub3pt ปีที่แล้ว +2

    Bahut hi achchha concept de diya sir....

  • @br8121
    @br8121 5 หลายเดือนก่อน +1

    Straight forward and deep explanation thankyou & God bless you dear

  • @dineshmundel9419
    @dineshmundel9419 11 หลายเดือนก่อน +1

    Superb Technical Sound 👌 very helpful for me..😊

  • @sarikajeswal6016
    @sarikajeswal6016 ปีที่แล้ว +2

    Super Hit❤❤❤❤VDO👏👏👏

  • @khajashaik6315
    @khajashaik6315 5 หลายเดือนก่อน +1

    Very good explanation sir I appreciate you thanks.

  • @naveenjsw1990
    @naveenjsw1990 5 หลายเดือนก่อน +1

    Excellent explanation. Thankyou

  • @Creativemindset007
    @Creativemindset007 6 หลายเดือนก่อน +1

    Very good explanation

  • @ankitkumar-ix5mc
    @ankitkumar-ix5mc หลายเดือนก่อน

    Very informative
    Thanks a lot sir

  • @saisantosh6623
    @saisantosh6623 6 หลายเดือนก่อน +1

    Valuable video

  • @rjsportsnews8191
    @rjsportsnews8191 3 หลายเดือนก่อน +1

    Very nice sir...

  • @sudhi944
    @sudhi944 หลายเดือนก่อน

    👏👏👏👌👌👌👌👌👍👍

  • @comedyraja-sk8xs
    @comedyraja-sk8xs 10 หลายเดือนก่อน +1

    Thnks for a make this.

  • @shivshankarkumbhkar225
    @shivshankarkumbhkar225 11 วันที่ผ่านมา +1

    Thank u so much sir, but in last topic we can adjust bearing temp around 85-95’c if I’m not wrong

    • @electricalpracticalfunda
      @electricalpracticalfunda  11 วันที่ผ่านมา

      @@shivshankarkumbhkar225 yes bearing temp limit vary for LT and HT motors also .

  • @shahidchowdhury5091
    @shahidchowdhury5091 หลายเดือนก่อน

    Mv motor explain. Mv vfd panel. Cascaded circuits se kaise kaam krta hai

  • @bilalanwer7490
    @bilalanwer7490 6 หลายเดือนก่อน +1

    51N used for HT Motor Ground fault protection in our plant kindly upload related Short video for understanding

  • @panchipaliwal
    @panchipaliwal 27 วันที่ผ่านมา +1

    Settings for differential

  • @tanzeemkhan85
    @tanzeemkhan85 14 วันที่ผ่านมา +1

    Exceptional!!

  • @swarupmohanty3655
    @swarupmohanty3655 ปีที่แล้ว

    Ek HT slipring induction motor me rotor circuit current kitna hona chahiye? Eg 360KW L n T motor

    • @electricalpracticalfunda
      @electricalpracticalfunda  ปีที่แล้ว

      For that we need other parameters also ex operating voltage, rotor resistance etc..we have HT Motor of 3380 KW op vol -11 kV and rotor current is 2855 A and Rotor V - 2800 V .

  • @ivanmartinez6623
    @ivanmartinez6623 2 หลายเดือนก่อน +1

    I wish this was in English or subtitles

    • @electricalpracticalfunda
      @electricalpracticalfunda  2 หลายเดือนก่อน

      As per your request I will try to make same video in English...

    • @electricalpracticalfunda
      @electricalpracticalfunda  2 หลายเดือนก่อน

      I will try to make this video again in English as per your request..

  • @sandeepkumarmahto2579
    @sandeepkumarmahto2579 7 หลายเดือนก่อน +1

    Motor ke neutral point ko ground kyu nhi karte h. . .karne se kya faida ya nuksaan hoga

    • @electricalpracticalfunda
      @electricalpracticalfunda  6 หลายเดือนก่อน

      a motor operates on the principle of electromagnetic induction, which does not require a neutral connection. Moreover in case of earth fault( phase to earth) relay can't detect the fault and motor winding mayl get burn and there is only loss no benefit...

  • @ItopaMusari
    @ItopaMusari หลายเดือนก่อน +2

    I need this video in english pls

    • @electricalpracticalfunda
      @electricalpracticalfunda  หลายเดือนก่อน

      Ok I will try to make this video in English also....

    • @irfanulhaq5350
      @irfanulhaq5350 19 วันที่ผ่านมา

      @@electricalpracticalfundapls do it

  • @ashishfasate4850
    @ashishfasate4850 11 หลายเดือนก่อน +1

    What is cold load pickup in HT motor

    • @electricalpracticalfunda
      @electricalpracticalfunda  11 หลายเดือนก่อน +1

      When power supply has been unavailable for a period of time or motor is not in running state for long period of time so that the load has reached a COLD STATE before being re-energized .

    • @ashishfasate4850
      @ashishfasate4850 11 หลายเดือนก่อน +2

      @@electricalpracticalfunda sir please make video on cold load pick up

    • @electricalpracticalfunda
      @electricalpracticalfunda  11 หลายเดือนก่อน +1

      @@ashishfasate4850 sure !!👍