Programmable triggered timing board 35238 MP | How to program ?
ฝัง
- เผยแพร่เมื่อ 3 ม.ค. 2025
- Microprocessor based, programmable, triggered timing module. Opto-isolated trigger input starts timing.
Programmable as a Delay on Start, Delay on Stop or Recycling.
Programmable ON Time/OFF Time/Number of Recycles (Looping)
Programming requires patience and practice.
Time Range: 3
Range:0.1sec. to 999min.
0-999 Minutes 1 Minute Resolution
0-999 Seconds 1 Second Resolution
0-99.9 Seconds .1Second Resolution
Power: 6-30VDC
Join my telegram channel for discussion or any problem in your Project :- telegram.me/te...
Click on the link to buy triggered timing board 35238 MP:- amzn.to/3rQQfFu
02:27 : circuit connection of triggered timing board 35238 MP
06:18 : set the second minute and hour in triggered timing board 35238 MP
07:06 : Program 1 of triggered timing board 35238 MP
09:00 : program 2 of triggered timing board 35238 MP
10:27 : program 3 of triggered timing board 35238 MP
11:34 : program 4 of triggered timing board 35238 MP
13:07 : loop program 5 of triggered timing board 35238 MP
Follow Facebook Page of techiqbal for science and technology-related update:- /
website:-techiqbal.com
Follow the Instagram page of techiqbal for science and technology-related update:- ...
#Programmabletriggeredtimingboard35238MP
#triggeredtimingboard35238MP
#timingboard35238MP
#35238MP
#education
#techiqbal
Bhai apka bhut Bhut Shukriya dil se❤❤❤❤❤ Jo mujhe settings chahye tha waise hi batya apne shukriya 😘
बहुत ही बढ़िया समझाया आपने hats off to you.
Can you provide a direct link to the English video? I followed all of the links in the description and none of them took me to it. Thank you!
هل يمكن ربطه مع محركين جهد كل واحد 4w المرجو الرد شكرا اخي
What load can be given on No and NC and between commen.
Can we start and run 1.5 ton AC with NO/NC and common.
No, the relay used in this can't take much load, you can remove the relay and put SSR (40amp) instead of that, now you can use it
Waah Iqbal Ji Waah
Waah Iqbal Ji Waah
Shuqriya shuqriya
Can we give direct current (without bettry) to this circuit as input?
we can use milliseconds............??
excellent video
micro USB power connector se power dekar circuit ko operate karna hai toh optocoupler ki pin no 3,4 ko short karke trigger Dene se circuit ko operate kar sakte hain (optocoupler ko voltage isolate ke liye use Kiya gaya hai )
agar USB power connector se supply dete Hain to trigger ke liye only push button switch Kam nahin karengi use trigger voltage Dene ki jarurat padegi battery positive and negative supply say trigger kar sakte hain ....... 🙂 very nice video
👍
Hi Iqbal,This is a very good solution to run the pump for desired time, further advance, can this device modify in such a way, that it can counts time. if there is load shedding within the desired time set, the pump will not run. So I want, if there is high trigger it the clock will count the time, in ansense of high trigger clock will stops, no reset of timer, again high trigger resume the timer count and so on, after the desired OP time, say one hour or two hours relay will be off. Can it be possible?
yes , it is possible
@@Techiqbal Thank you for prompt and positive response,. May I ask you to help or guide in this regard.
@@amitavadutta77 yes sure
@@Techiqbal Please help me to modify or reprogrammed the device to count the accumulated powered on time and off the relay after set OP time.
What is the program for when we click 2nd time in between, it has to compleat the first program and take some seconds and start again the second trigger automatically.
I am supplying DC 12V and want to get output DC 12V, but no output is coming. Relay is on and working, but no output on NC and common
I want to power the relay using just the 12V battery, so no secondary power from microusb
Same, i just confused, what is the value of output, AC or DC?
Ek bar power supply off hone ke bad dobara power on hone par kya set kia hua program ise yad rehya hy. Memory me save rehta hy
Pls reply
Assalam O alaikum...
Dear ap ny jz 801 ki setting batae thi.
Mujhy pochna ye tha k kya ye device 10 hours on rahy 14 hours off aur ye looping rahy.
Actually mn is module k through Solar inverter ka on off automatic krna chah rha hn is this possible?
Very nice explain
mujhe 20 milli second se 50 milliseconds ki timing chahiye, kaise karu?
so that the screen stays on standby, what do you do, the problem is that the screen goes out for a few minutes but it keeps counting.
Super description
Sir iska price kya hai. Aur kaha milega
brother how to use these programs ?
Bhai 5 min lagana hai number kaise kitna set kare 3 point me
Bro aap ne push bottom kiyun lagaya isse khud ba khud time k mutabiq turning kare
Bhai isme agar ek baar trigger karne ke baad 1 sec on aur 1 sec off aise loop karna hai to kya program karna hoga
I also want to know that
Thanks a lot dear
Output connection kaise honge
Bhai, Mera module ka relay bhi chalta hai Awaaz bhi karta hai lekin load mein power nahin aa raha hai.
check with the connection
Sar ham tri gal dabay tochale
Prrrooowaaming........ the prrroowaam.....
Sorry for the fun I like the pronunciation
Grand me red waer Donki pan h
Supper love you
सर पुश बटन के साथ मोटर कैसे चलाएं उसका कनेक्शन
WHY DO YOU PUT YOUR FINGERS WHEN OPERATION IS GOING ON. THE VIDEO IS SHOWING
AS IF YOU ARE PRESSING THE MICRO SWITCH
Timer kaha milega sir ?
link given in description box
🔥🔥
Output chalake to dikhate
Bahut bhadiya bhai🔥
Shuqriya bhai 👍👍
@@Techiqbal Bhai led me light nahi aa rha h Aisa q
Apko iske bare ma or sekh ne ki jarurat hai 😂😂
A hot Sahi
English!!
Sir aapka number milega