Time stamps: 0:00 In this video 02:32 Frame hood removal 07:08 Spring and Arm removal 09:56 Lock ring removal 15:50 Important tip for lock ring removal 18:58 Bowl hood and Main seal ring removal 20:55 Top Disc Removal 25:10 Distributor and disc stack Removal
Hlo Sir. What a great video thank you.. I just want to ask u something regarding 946 s flex hfo purifier.. I opened cleaned changed rectangular ring and box it up back. It ran without any alarm but after 24 hours it started giving alarm pt5 outlet pressure low. I tried to desludge and started again without any problem then after 4 hours same alarm. I opened up the top housing and saw nothing worng with the pairing tube, But after inspection of paring tube this alarm is coming again.. During initial start pt5 is 2.5-2.4 bar then goes upto 3.1 bar but after sometime it agin goes to 0 bar. I checked local and pannel pt5 reading is the same. I'll share the parameters Pt1- .21 Pt4-1.68 Pt5- 2.4 ( then goes to 0) Feed-1.4m3 Feed temp 98°c Fuel type- vlsfo density 972.5 Awaiting your response
Hi Arjit . Have you tried replacing the PT5 sensor (if you don’t have a new one , you can swap from a different purifier) If the problem still persists, try to see if the paring tube is chocked with sludge . Also you can check if the paring tube is moving freely and is coming back quickly due to the spring force . If paring tube is not moving freely, try replacing the bushes.
You are the best teacher chahe kuch b padhao apke jitni mehnat or dedication or kisi mai nai ho skti❤
Have only done self jectors uptill now but alfa levels wont be a problem with help of your videos ❤
now all my doubts are clear❤
Beautifully explained ✌️
Very nice explanation
Fantastic
Time stamps:
0:00 In this video
02:32 Frame hood removal
07:08 Spring and Arm removal
09:56 Lock ring removal
15:50 Important tip for lock ring removal
18:58 Bowl hood and Main seal ring removal
20:55 Top Disc Removal
25:10 Distributor and disc stack Removal
Hello my friend. Thank you. Where ı can find this alfa laval official video?
Hi . I’m not sure if this video is available online . I copied this vodeo from one of my croatian colleagues.
Hlo Sir. What a great video thank you..
I just want to ask u something regarding 946 s flex hfo purifier..
I opened cleaned changed rectangular ring and box it up back. It ran without any alarm but after 24 hours it started giving alarm pt5 outlet pressure low. I tried to desludge and started again without any problem then after 4 hours same alarm. I opened up the top housing and saw nothing worng with the pairing tube,
But after inspection of paring tube this alarm is coming again..
During initial start pt5 is 2.5-2.4 bar then goes upto 3.1 bar but after sometime it agin goes to 0 bar. I checked local and pannel pt5 reading is the same.
I'll share the parameters
Pt1- .21
Pt4-1.68
Pt5- 2.4 ( then goes to 0)
Feed-1.4m3
Feed temp 98°c
Fuel type- vlsfo density 972.5
Awaiting your response
Hi Arjit . Have you tried replacing the PT5 sensor (if you don’t have a new one , you can swap from a different purifier)
If the problem still persists, try to see if the paring tube is chocked with sludge .
Also you can check if the paring tube is moving freely and is coming back quickly due to the spring force . If paring tube is not moving freely, try replacing the bushes.