Complete Alfa Laval Purifier Intermediate overhaul - Tips, Tricks and best practices.

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ธ.ค. 2024

ความคิดเห็น • 12

  • @garimasharma140
    @garimasharma140 2 หลายเดือนก่อน +1

    You are the best teacher chahe kuch b padhao apke jitni mehnat or dedication or kisi mai nai ho skti❤

  • @harmanpreet_07
    @harmanpreet_07 2 หลายเดือนก่อน

    Have only done self jectors uptill now but alfa levels wont be a problem with help of your videos ❤

  • @devanshsaini2384
    @devanshsaini2384 2 หลายเดือนก่อน +1

    now all my doubts are clear❤

  • @arnabhreja4608
    @arnabhreja4608 2 หลายเดือนก่อน

    Beautifully explained ✌️

  • @jagmohanvashisht6305
    @jagmohanvashisht6305 2 หลายเดือนก่อน +1

    Very nice explanation

  • @MichaelUkken-l9w
    @MichaelUkken-l9w 2 หลายเดือนก่อน +1

    Fantastic

  • @SeaworthySailors
    @SeaworthySailors  2 หลายเดือนก่อน +2

    Time stamps:
    0:00 In this video
    02:32 Frame hood removal
    07:08 Spring and Arm removal
    09:56 Lock ring removal
    15:50 Important tip for lock ring removal
    18:58 Bowl hood and Main seal ring removal
    20:55 Top Disc Removal
    25:10 Distributor and disc stack Removal

  • @nonono7674
    @nonono7674 หลายเดือนก่อน

    Hello my friend. Thank you. Where ı can find this alfa laval official video?

    • @SeaworthySailors
      @SeaworthySailors  15 วันที่ผ่านมา

      Hi . I’m not sure if this video is available online . I copied this vodeo from one of my croatian colleagues.

  • @Arjit90270
    @Arjit90270 27 วันที่ผ่านมา

    Hlo Sir. What a great video thank you..
    I just want to ask u something regarding 946 s flex hfo purifier..
    I opened cleaned changed rectangular ring and box it up back. It ran without any alarm but after 24 hours it started giving alarm pt5 outlet pressure low. I tried to desludge and started again without any problem then after 4 hours same alarm. I opened up the top housing and saw nothing worng with the pairing tube,
    But after inspection of paring tube this alarm is coming again..
    During initial start pt5 is 2.5-2.4 bar then goes upto 3.1 bar but after sometime it agin goes to 0 bar. I checked local and pannel pt5 reading is the same.
    I'll share the parameters
    Pt1- .21
    Pt4-1.68
    Pt5- 2.4 ( then goes to 0)
    Feed-1.4m3
    Feed temp 98°c
    Fuel type- vlsfo density 972.5
    Awaiting your response

    • @SeaworthySailors
      @SeaworthySailors  15 วันที่ผ่านมา

      Hi Arjit . Have you tried replacing the PT5 sensor (if you don’t have a new one , you can swap from a different purifier)
      If the problem still persists, try to see if the paring tube is chocked with sludge .
      Also you can check if the paring tube is moving freely and is coming back quickly due to the spring force . If paring tube is not moving freely, try replacing the bushes.