Preparing a New RECOVERY BOTTLE for the HVAC Service Truck!

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ส.ค. 2024
  • In this HVAC Training Video, I Show How to Prepare a New Recovery Tank for Service by Releasing the Nitrogen, Vacuuming to 300 Microns, and Breaking the Vacuum with Refrigerant from Another Full R-22 Recovery Bottle. I Show How To Know What Refrigerant is in the Bottle and How to Know if it's Contaminated! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    Tools Used In The Video
    CPS 4 CFM Vacuum Pump - amzn.to/2DxgPwY
    CPS Vacuum Micron Gauge - amzn.to/2v1nM3O
    Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • R-410A Charging and Re...
    • Refrigerant Recovery T...
    • Recovering Refrigerant...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicet...
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicet...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtoo...
    Refrigerant Charging Book and E-Book: www.acservicet...
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicet...
    Our Newest Articles: www.acservicet...
    Try our HVAC/R Quizzes! www.acservicet...
    Our Other Resources: www.acservicet...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicet...
    Our Tool List on Amazon: www.amazon.com...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtoo...
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.c...
    Apple Podcasts: podcasts.apple...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #recoverybottle #vacuum #vacuumpump #recoverytank #recoverybottle #r22 #refrigerant #microns #nitrogen
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

ความคิดเห็น • 98

  • @trenthelms
    @trenthelms 10 หลายเดือนก่อน +3

    Thank you for posting this video. It's clear and timely. It also convinced me to go ahead and buy that vaccum gauge. Looks like cheaper options can't be trusted.

  • @danthesupercontractorhvac9690
    @danthesupercontractorhvac9690 2 ปีที่แล้ว +6

    In my case, I pull my recovery tanks down to under 100 microns. Yes I also break the vacuum with refrigerant asap, im not sure the tank valves are vacuum rated.

  • @fernandofrancisco3106
    @fernandofrancisco3106 2 ปีที่แล้ว +6

    Thanks for sharing your wonderful video it’s full of great information. So much knowledge. Everything is well explained. Thanks Craig

  • @user-kt2hb8xr3p
    @user-kt2hb8xr3p 2 ปีที่แล้ว +4

    Great job, thank you brother. You are so talented

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 ปีที่แล้ว +1

    Anytime we prepared a tank it was ready for use,nice to know though !!! 😉
    🍺🍺🍺🥃🥃🍿🏌🏻‍♀️
    Stay safe.
    Retired (werk'n) keyboard super tech. Wear your safety glasses!

  • @alwysrite
    @alwysrite 2 ปีที่แล้ว +2

    thanks for the great practical knowledge

  • @Colt-wr6wx
    @Colt-wr6wx 2 ปีที่แล้ว +1

    Good practices but I mean really only takes 10 minutes.. thanks Craig 👍

  • @lubacotemobile
    @lubacotemobile 2 ปีที่แล้ว +1

    Glad I watched this.

  • @padilla7019
    @padilla7019 2 ปีที่แล้ว

    I keep learning so much from your videos

  • @davidnunez7889
    @davidnunez7889 ปีที่แล้ว +1

    Great video Craig thank you for the information

  • @a11ten071
    @a11ten071 2 ปีที่แล้ว +2

    TNX again for another great video, avid follower here.

  • @ivanbalmore7425
    @ivanbalmore7425 ปีที่แล้ว +1

    WOW, excellent video . Muchas gracias

  • @mikemaj8467
    @mikemaj8467 ปีที่แล้ว +2

    How would your procedure differ if you didn't have a full recovery cylinder to bleed into the new one under vacuum. Would i be correct to assume i would start recovery with the new tank under vacuum, bleed my hose with pumped refrigerant coming from the recovery machine or compressor, then slowly open the new tank to accept the recovered refrigerant? Thank you so much for your attention to detail in all of your videos. I have learned a great deal!

  • @hashimshams9633
    @hashimshams9633 2 ปีที่แล้ว +1

    Thank you, thank you, thank you

  • @theaustinite5320
    @theaustinite5320 2 ปีที่แล้ว +1

    Thanks for your videos.

  • @donaldnaymon3270
    @donaldnaymon3270 2 หลายเดือนก่อน

    Great video. Good information. Thank you for sharing

  • @tube8533
    @tube8533 หลายเดือนก่อน

    Great video!

  • @SultansIsle
    @SultansIsle ปีที่แล้ว +1

    I thought Blue went to the bottom of the tank, the low side, while the Red, the high side, has no drop tube. Liquid verses Vapor. Never seen a tank where Liquid was Red. Just heard of them.

  • @hassanmohamed4445
    @hassanmohamed4445 2 ปีที่แล้ว +1

    Thank you you are very clever.

  • @WallaceRoseVincent
    @WallaceRoseVincent 2 ปีที่แล้ว +4

    Have you done a episode on component ( or additional circuits) that are supposed to extend the life of a compressor? Do they really work?

  • @AFTABAHMED41
    @AFTABAHMED41 ปีที่แล้ว +2

    Please can you explain on recovery cylinder red and green color valve what's working differently ?

  • @luiselizalde6757
    @luiselizalde6757 2 ปีที่แล้ว +1

    As always something new to learn, thanks teacher for such as wonderful videos, .

  • @D2DNYAC
    @D2DNYAC 2 ปีที่แล้ว

    Usually when pick those up from the supply house it’s already in a vacuum, useful video however

  • @robertdefreitas940
    @robertdefreitas940 2 ปีที่แล้ว +2

    im gonna guess you did this to reuse r22 in the same system. bc nobody does this for just recov....hell, with that tank in a vacuum, itll pull a good 3 or so pounds out wo the recov machine even on.

  • @Alex-jo2oi
    @Alex-jo2oi ปีที่แล้ว

    If I follow this process I can use the recovered refrigerant in the same system for service correct

  • @alohadoc1
    @alohadoc1 วันที่ผ่านมา

    Where did you get that hose!! I need one with 1/4' female flare both ends. Cant fine it anywhere.

  • @thegrt1hasarrvd
    @thegrt1hasarrvd 7 หลายเดือนก่อน

    Why must you set the units to Microns as opposed to using other units such as inches of mercury?

  • @pubchat2913
    @pubchat2913 2 ปีที่แล้ว +2

    Why is it bad to leave the tank in a vacuum for a few days?

  • @OminousCamaro
    @OminousCamaro 2 ปีที่แล้ว +1

    did he just say ooopen?

  • @dedwards0117
    @dedwards0117 19 วันที่ผ่านมา +1

    Will your books prepare someone for the EPA 608 Type II exam?

    • @acservicetechchannel
      @acservicetechchannel  19 วันที่ผ่านมา +1

      Epa answers are certainly weaved through the book and it will definetly help any reader do better on the epa test but its not a test prep book specifically for the test. This is about all the procedures we use in the field, thanks!!

    • @dedwards0117
      @dedwards0117 16 วันที่ผ่านมา

      @@acservicetechchannel Ok thank you

  • @OneBiteWillis
    @OneBiteWillis 2 ปีที่แล้ว

    Would it be better to, let's say the morning of recovery, to do the same process, but not break the vacuum with the already recovered refrigerant? Instead wouldn't it be better to break the vacuum with the refrigerant from the system you are recovering from in order to lower the recovery process time? It just seems like a little bit of rework rather than just keeping the nitrogen charge. Love your videos, and have learned SO much, just thought i'd ask the question. Thanks.

    • @jaycweingardt11
      @jaycweingardt11 ปีที่แล้ว

      That's what I thought, no reason to break vacuum

    • @RandomRepairGuy
      @RandomRepairGuy ปีที่แล้ว

      He said he was doing it because the bottle would be stored for some time.

    • @hjc4604
      @hjc4604 11 หลายเดือนก่อน

      @@RandomRepairGuy So why can't it be stored with a vacuum?

    • @ethanwaddell3005
      @ethanwaddell3005 3 หลายเดือนก่อน

      exactly what i was thinking why cant we just store it with the positive nitrogen charge its the same purpose as the positive refrigerant charge seems like a waste of time

  • @jimwhite9483
    @jimwhite9483 ปีที่แล้ว

    One and done if you hit it with liquid.

  • @thesilentonevictor
    @thesilentonevictor 2 ปีที่แล้ว +1

    Very interesting

  • @nathanguerrero882
    @nathanguerrero882 10 หลายเดือนก่อน

    What about on a hotter day?

  • @cck1496
    @cck1496 2 ปีที่แล้ว +1

    Good video. Why did you fill the cylinder in pulses and not continuously?
    Thanks.

    • @The-H-inADHD
      @The-H-inADHD 9 หลายเดือนก่อน +1

      He was just trying to get the pressure just over 0 psi, but the gauge he used to check the psi was the gauge that was filling the tank. So the pressure goes up when adding the refrigerant, and when he stops adding it it reads the tank pressure.

    • @cck1496
      @cck1496 9 หลายเดือนก่อน +1

      @@The-H-inADHD Thanks for the clarification. Appreciate.

    • @The-H-inADHD
      @The-H-inADHD 9 หลายเดือนก่อน

      @cck1496 sorry I was a year late! lol

  • @jonweinberger8436
    @jonweinberger8436 2 ปีที่แล้ว

    Good video. Why shouldn’t you store the tank under a vacuum though?

    • @andrewschmidt7016
      @andrewschmidt7016 7 หลายเดือนก่อน

      Because the vacuum will decay - it’s easier to maintain a positive pressure on a tank where the vacuum was broken w refrigerant that to keep that vacuum.
      One reason could be that the tank valves aren’t vacuum rated

  • @alexibonnet2634
    @alexibonnet2634 10 หลายเดือนก่อน

    Question
    When I exchange a bottle from JOHNSTONE supply the bottle that I’m given does it have a vacuum on it or do I need to pull a vacuum on it

  • @MRamirez1885
    @MRamirez1885 5 หลายเดือนก่อน

    New from supplier with nitrogen charge? All my tanks come in a vacuum already

  • @PoliCronis86
    @PoliCronis86 2 ปีที่แล้ว +1

    Good evening from Greece. I have been watching your channel for a long time and thank you for what you have taught me. I want to ask you a question if you know and can you help me. I'm looking for the adapter you have on the pressure gauge. Do you know where I can find it? Thank you and keep up the good work.

    • @warenmann1042
      @warenmann1042 2 ปีที่แล้ว +1

      Amazon...Yellow Jacket 19110 Ritchie Quick Coupler

    • @PoliCronis86
      @PoliCronis86 2 ปีที่แล้ว +1

      @@warenmann1042 Thank you, you are awesome. I just ordered it.

    • @user-dy6on2ue4e
      @user-dy6on2ue4e 2 ปีที่แล้ว

      Ο καλύτερος δάσκαλος φίλε

    • @PoliCronis86
      @PoliCronis86 2 ปีที่แล้ว

      @@user-dy6on2ue4e πολύ καλός. Μήπως έχεις πάρει το βιβλίο του?

  • @stevengao8345
    @stevengao8345 2 ปีที่แล้ว +1

    thanks for this video, what if i left some nitrogen inside the tank and just vaccume it, will nitrogen ruin the overall quality of my refrigerant R410a and make it unusable ? thanks

    • @user-hu4hx6bm6m
      @user-hu4hx6bm6m 2 ปีที่แล้ว

      Yes

    • @user-hu4hx6bm6m
      @user-hu4hx6bm6m 2 ปีที่แล้ว

      Yes

    • @stevengao8345
      @stevengao8345 2 ปีที่แล้ว

      @@user-hu4hx6bm6m but i did a deep vaccume, i wait until under 250 Microns, i really don't want to waste my 10lbs of r410a, you know how expensive it is ?

    • @kyleperry1701
      @kyleperry1701 2 ปีที่แล้ว

      @@stevengao8345 if you vacuumed it to 250 then obviously the positive charge of nitrogen is gone so you are good

    • @jerrypeal653
      @jerrypeal653 2 ปีที่แล้ว

      You vacuumed out the nitro.

  • @royjohnson4741
    @royjohnson4741 6 หลายเดือนก่อน

    Where did you get the other yellow hose from 🤔

  • @Skunkhunt_42
    @Skunkhunt_42 5 หลายเดือนก่อน

    Why use 1/2" hose?

  • @Ray-wr2wr
    @Ray-wr2wr ปีที่แล้ว

    How long it takes to pull vaccum below 500micron with 7cfm vaccum ?
    I have tez8 appion pump

  • @cowpiecowboy7599
    @cowpiecowboy7599 ปีที่แล้ว

    I messed up somehow I think I pulled vacuum pump oil into my tank

  • @viisteist1363
    @viisteist1363 2 ปีที่แล้ว

    so u dont have to pull the moisture out from the blue and yellow hoeses or even use a filter drier?

    • @wiley0714
      @wiley0714 9 หลายเดือนก่อน

      He used a filter dryer.....
      When he purged the hoses with refrigerant the filter dryer would absorb the moisture....

  • @jaycweingardt11
    @jaycweingardt11 ปีที่แล้ว

    Why do I need to break vacuum, seems unnecessary at all.

  • @automationpk6720
    @automationpk6720 2 ปีที่แล้ว

    I need this booklet in Pakistan

  • @4bearsi678
    @4bearsi678 2 ปีที่แล้ว +1

    I store mine vacced and ready for several days with no ill effect so I’m not sure why you’re saying not to

  • @KennethMillerdotcom
    @KennethMillerdotcom ปีที่แล้ว

    Can a recovery machine be used in place of a vacuum pump so that only one pump machine is needed?

    • @wiley0714
      @wiley0714 9 หลายเดือนก่อน

      Absolutely not.

  • @Devi1D0g04
    @Devi1D0g04 2 ปีที่แล้ว

    Im a little confused on Where you read that the tank was just above zero?

    • @lloydbrown1512
      @lloydbrown1512 2 ปีที่แล้ว +1

      he's using the blue gauge to see when it rises above 0

  • @xtreme7386
    @xtreme7386 ปีที่แล้ว

    Are you able to use that same pump for the extraction of the freon in the refrigerator?

    • @dylanwood1944
      @dylanwood1944 ปีที่แล้ว

      No it will break the vacuum pump. You'll need a recovery machine

    • @wiley0714
      @wiley0714 9 หลายเดือนก่อน

      That (pump) he used was a "recovery machine". The machines are rated for different refrigerants. If the machine matches the refrigerator refrigerant then yes.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 ปีที่แล้ว +1

    Why wouldn't you leave the recovery bottle in a vacuum.

    • @coldfinger459sub0
      @coldfinger459sub0 2 ปีที่แล้ว +4

      Because if there was a leak in the valve stem or the inner valve seal over time it was slowly leaking wet moist atmospheric air contaminating the bottle.
      Then later when you get out to your building that you need to recover refrigerant you would contaminate the refrigerant with that atmospheric moist air.
      Air is a non-condensable
      Moisture is a contaminant that causes acid, expansion valve freeze ups, breakdown of refrigerant oil.

    • @jasonjohnsonHVAC
      @jasonjohnsonHVAC 2 ปีที่แล้ว +1

      @@coldfinger459sub0 i understand that, but a leaking bottle is a leaking bottle. If it had refrigerant it would leak out as well. If it pulls a good vacuum and holds then you know it doesn't leak. I have tanks in a vacuum. When recovering it pulls the refrigerant fast from the system. Its all about pressure differential. I know my tanks are sealed, because i pull a vacuum on them whenever i use a new one. Its not like i sit on tanks for months at a time. In commercial/ industrial your systems hold big amounts that usually fill the bottle, so im constantly getting new bottles.

    • @coldfinger459sub0
      @coldfinger459sub0 2 ปีที่แล้ว +1

      @@jasonjohnsonHVAC Yes I constantly have nearly 40 bottles between 30 pounders and 50 pounders and 240 pounders
      It’s easy not to have a leak under vacuum the difference between a complete vacuum and atmospheric pressure is only 14.7 psi depending on your refrigerant when you have even one drop or 20 pounds of liquid refrigerant it could be 70 psi or 220 psi at room temperature.
      And if it’s the recycle containers we turn in for exchange they often have bad shaft seals on the handles when you mid seat them during your vacuum or pressure and usually you cannot tell under vacuum they leak until you front seat them all the way down.
      And he’s only filling it to just above zero psi.
      So there’s only 14.7 psi difference between your system pressure in the cylinder you’re about to fill with nearly no mass because you have zero liquid in the new cylinder.
      And if you were going to reuse the refrigerant and put it back into the customers system you would rather have 0% chance of a vacuum leak taking in air noncondensibles and moisture.
      Then if you had the slightest leak if you were at one or two psi positive with refrigerant so what if it leaked out it’s negligible when you go to use your tank at least it doesn’t have moist atmosphere mixed in that you’re about to re-introduced back into the customers unit.
      In my local region we have Plax Air and Airgas. As our suppliers in our local refrigerant warehouse distributors.
      To cut corners on cost and time and materials they used to come pre-charged with nitrogen now they deliver us cylinders that are under vacuum.
      And because their seals are not perfect you often discover The seal has leaked and now you have a tank full of air.
      And if you send one of your employees or yourself on a job and you’re near $300 an hour your technician now have to break out a vacuum pump terret up on the roof that he already has his tank that he just discovered had a vacuum leak and vacuum it down before recovering refrigerant.
      It’s happened to me and many other people on several occasions that’s why we do not leave the cylinders stored under vacuum.
      Either storage under positive pressure refrigerant or positive pressure nitrogen.
      And when you’re pulling a vacuum on your refrigerant cylinder and discover you cannot get below 100 µm it’s probably because the packing in the shaft seal of the valve is leaking.
      So while it’s under vacuum pulling down and you discover the situation you put a little silicone grease or a little nail log around the valve stem of the handle screw it down a little bit and you’ll see the vacuum leak disappear and you continue on pulling your cylinder down well below 100 µm.

  • @jaredj631
    @jaredj631 2 ปีที่แล้ว

    I accidentally put a little r404a into my r134a tank yesterday 🤦‍♂️

    • @ethanwaddell3005
      @ethanwaddell3005 3 หลายเดือนก่อน

      how did you end up fixing that? curious i am in tech school for hvac

    • @jaredj631
      @jaredj631 3 หลายเดือนก่อน

      @@ethanwaddell3005 I don’t remember, I also don’t remember writing this or doing it. Lol.

  • @lamonjackson5109
    @lamonjackson5109 2 ปีที่แล้ว

    How and where can I purchase that hose?

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 ปีที่แล้ว

    👍

  • @wiley0714
    @wiley0714 9 หลายเดือนก่อน

    My new recovery tank has a "rattle" sound inside.
    I did vacuum it to about 350 microns.
    Why does it rattle. Anyone wanna help me on that one.
    Its a legal DOT approved brand. Not an Amazon special aka Vevor tank.......?????

  • @fireyourrocketts
    @fireyourrocketts ปีที่แล้ว

    Is this needed to recover Car AC System Freon 134a? Got same tank but none of the car recovery videos show vacuum the tank, only bleed air from lines. In my case whatever I recover will take in for recycling, I am not re-using what comes out of the car but new freon.

    • @wiley0714
      @wiley0714 9 หลายเดือนก่อน

      EPA regulations state your must recover the refrigerant.
      You can also take an EPA609 online class and be certified to do that.

  • @user-ic9pp5ix1o
    @user-ic9pp5ix1o 3 หลายเดือนก่อน

    How is freon R22 still available ? :/

    • @dontmesswiththeman
      @dontmesswiththeman 13 วันที่ผ่านมา

      It’s only available as old stock, it’s no longer available in the US. There are substitute refrigerants available to keep old R-22 systems running with a currently produced refrigerant that is less costly than old stock or recovered R-22.

  • @rajaguilar
    @rajaguilar 2 ปีที่แล้ว

    how to buy ac tech book sir? where i can buy for that.? im in the Philippines..

  • @brianmenendez
    @brianmenendez 2 ปีที่แล้ว +2

    yeah and then you go and recover contaminated r22 from a customer who already used several backyard mechanics defeating the purpose, but thanks, good video anyways

  • @roseelectronics4582
    @roseelectronics4582 2 ปีที่แล้ว

    First

  • @karaors8970
    @karaors8970 2 ปีที่แล้ว

    🇹🇷👍🤳🛠️