15kw MEP-804A Military Generator major repair

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 มิ.ย. 2021
  • Tune in to my journey into repairing this Fermont 15kw 804-a diesel generator with an isuzu c-240 engine
    This video was powered by 70% diesel generator and 30% solar :)
    Special shoutout to Jim at Joilet electric motors for being able to rewind the exciter coils!!!
    Link to the manual. www.liberatedmanuals.com/TM-9...
    Link to voltage regulator. www.amazon.com/dp/B08L11GT66?...

ความคิดเห็น • 44

  • @ltr6541
    @ltr6541 2 ปีที่แล้ว +4

    Oh my God your projects turn out EXACTLY like mine do :-P there is nothing wrong with this its awesome...and I end up becoming an expert on what I'm fixing haha awesome generator :-) that will be with you the rest of your life now :-) I always smile when things go south with power and your neighbors show up with cords for their houses:-)

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว

      Yeah hahaha man this thing has been one heck of an adventure. I still have some minor parts that this thing needs that I can’t find yet like a fuel filler neck

  • @tujuprojects
    @tujuprojects 4 หลายเดือนก่อน

    I think you’re correct about those vibration plates, I have seen them in boat axels.

  • @johnweatherford5760
    @johnweatherford5760 2 ปีที่แล้ว

    Thank you for the video I really enjoy the details.

  • @rickyvasquez3157
    @rickyvasquez3157 2 ปีที่แล้ว

    VERY NICE that was intense.

  • @mafosa8519
    @mafosa8519 2 ปีที่แล้ว

    "thats a bad ass gen.!"
    great share!
    larry

  • @T2D.SteveArcs
    @T2D.SteveArcs 9 หลายเดือนก่อน

    That's amazing, I want one 😂

  • @tujuprojects
    @tujuprojects 4 หลายเดือนก่อน

    Sorry to say, but once your contactor pulls between two generators, they are not going to fall out of sync :) or an axel will snap.

  • @basspig
    @basspig 20 วันที่ผ่านมา

    It appears that the fuel gauge on this generator is not working as it's all the way down off the scale. Is that a simple fix?

  • @ryanschulte1437
    @ryanschulte1437 ปีที่แล้ว

    More Juice!

  • @T2D.SteveArcs
    @T2D.SteveArcs 9 หลายเดือนก่อน

    😎👍

  • @javidgunraj1500
    @javidgunraj1500 4 หลายเดือนก่อน +1

    Does the low voltage light come back on? Mine comes on startup even with nothing connect

  • @marshallsayre58
    @marshallsayre58 2 ปีที่แล้ว

    So you had the stator&rotor rebuilt? In Chicago?

  • @bubbajoe745
    @bubbajoe745 ปีที่แล้ว

    So that thing that was hanging was the stator for the alternator?

  • @tujuprojects
    @tujuprojects 4 หลายเดือนก่อน

    How good frequency stabilization that genset has? My Quattro is very picky and my old genset has a mechanical governor which is not stable enough.

  • @lenielupian2699
    @lenielupian2699 2 ปีที่แล้ว

    Hi, could you tell me What place did you get the rewind done in Chicago?? I have a gen with a similar problem. And what did it cost for the repair.Thank you...

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว +2

      A place called Joliet electric motors. I would call them and get a quote. Talk to Jim.

  • @marshallsayre58
    @marshallsayre58 2 ปีที่แล้ว +1

    Hi, whts the dial L-1,L-2,L-3? I saw the same dial on anthr genset. These are pretty cool. Ill have to chk ur othr videos too

    • @Ringele5574
      @Ringele5574 2 ปีที่แล้ว

      Lug 1, Lug 2, Lug 3. For going from single phase to 3 phase.

    • @dynomatic5099
      @dynomatic5099  ปีที่แล้ว

      @@Ringele5574 the dial is for reading the voltage of each phase as well as current between phases i definitely need an update video i have been very busy with this new job i got.

  • @rolyisern4550
    @rolyisern4550 2 ปีที่แล้ว

    I have the exact same problem and I order the voltage regulator you said to get. Any way you can point me in the direction when switching the original wires to the new regulator

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว

      Yes I will be making another video on it soon

    • @Colton-dl1ig
      @Colton-dl1ig ปีที่แล้ว

      Have you made this video yet? I'm also interested in how you transferred the voltage regulator over. Thanks.

  • @tobyzahn9943
    @tobyzahn9943 2 ปีที่แล้ว

    I bought mine ina ebay auction, brought it home changed oil and filters, new suction line to feul tank, belt and batteries and walla. Tied into meterbase with a manual transfer switch. I ran it every sunday for a year powered up the house no issues. I am awaiting now the 2020 hurricane thinking how I will be her hero and envy of my neighbors......
    0430 AM... yes dear...the power is flickering storm is here...please go crank our generator. And I returned after an hour or so a ZERO. I cannot find infobon the F1 and F2 wires from the genhead itself. I think F2 ends up on terminal 1 of the voltage regulator? And am tracking back thru the fault relays to determine F1's destination?
    After a year of not completing my project I bought a engine controller and am in the process of dedicating my generator in a WYE High 240 configuration. I did replace the 6 rectifier diodes, just trying to determine the needs of F1 F2 ?
    The 10 lead lima mac info says self regulating and self exciting. What am I missing?

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว +1

      It is not self exciting. That is the purpose of the voltage regulator. What lights are on on the fault panel?

    • @tobyzahn9943
      @tobyzahn9943 2 ปีที่แล้ว

      @@dynomatic5099 thankyou for a reply. Well i got frustrated after the storm, 3 weeks w/o commercial power and no help and said ok 1800 rpm 1st purchased on ebay 100 bucks with low oil pressure/ overheat/over rev failsafes.
      No issue with the engine now.
      Next up no outputs. Lets just say I am only using the 10 leads WYE 3 PHASE, the contactor and a toggle switch. I am pretty sure i isolated and ohmed the 10 correctly, no shorts. I did find 2 bad diodes in the excite rectifier, replaced all 6.
      What options do i have for F1 / F2 ?
      I hope excitation and regulation are my final riddles...
      And I realize now all of the capabilites and options I lost, but wont ever ask anything more than crank, run and 120/240. And any T/S in the future should be just the basics. I really appreciate your time, thank you.

    • @tobyzahn9943
      @tobyzahn9943 2 ปีที่แล้ว

      @@dynomatic5099 I am looking into an AVR now, and I also am looking for another diode kit that includes 3 forward and 3 reverse diodes or an assembly.

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว +1

      I think it’s better if your able to have a voltage regulator because you can accommodate for voltage drop when loads are applied. A normal avr won’t necessarily accommodate for that and I definitely need it when I use my transformers so i’m able to use all 3 phases instead of one or two of the legs.

  • @hunterhines-qg2bn
    @hunterhines-qg2bn ปีที่แล้ว

    Can you show maintenance fluid to keep her top notch

    • @dynomatic5099
      @dynomatic5099  ปีที่แล้ว

      Yes I am working on another generator one soon within a month or two

  • @phemmymarruss
    @phemmymarruss 2 ปีที่แล้ว

    Hey, could you repair if I buy a used one?

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว

      Depending what’s wrong with it

  • @vespoli69
    @vespoli69 2 ปีที่แล้ว

    Why the transformers? Why doesn't the generator just output 208/3?

    • @dynomatic5099
      @dynomatic5099  2 ปีที่แล้ว +1

      It does but I like the higher voltages so it’s less of a voltage drop by the time it gets in the sub panel and I can configure the end voltage of 240 instead of just 208 for the house. I will be making a video of the complete system soon!

  • @juancervantes4128
    @juancervantes4128 6 หลายเดือนก่อน

    Mine runs fine but is not generating any power.

    • @dynomatic5099
      @dynomatic5099  6 หลายเดือนก่อน

      The only things it could be if it’s not generating any power is your voltage regulator has failed or maybe the same problem as mine were the exciter coils are gone or your main line contactors not pulling in Tri flipping battle short on and then pressing the on button to see if the mainline contactor pulls in and you get power out

  • @MrFungus2888
    @MrFungus2888 ปีที่แล้ว

    i have a 804a was working fine , then one day they only way it will make power is if you hold the start switch down .. what happened/

    • @dynomatic5099
      @dynomatic5099  ปีที่แล้ว

      Do you mean holding the main line contactor, closed or holding down the power start switch? Also, have you tried battle short yet??

    • @MrFungus2888
      @MrFungus2888 ปีที่แล้ว

      @@dynomatic5099 holding down the engine start switch it makes power. soon as you let of no power, as i said it was working. haven't tried battle short , will today

    • @MrFungus2888
      @MrFungus2888 ปีที่แล้ว

      battle switch made no difference, the under voltage light is on

    • @dynomatic5099
      @dynomatic5099  ปีที่แล้ว

      If the undervoltage light is on, that could mean that your voltage regulator is bad, the only way to check that is to measure the voltage on your exciter field windings.

    • @MrFungus2888
      @MrFungus2888 ปีที่แล้ว

      @@dynomatic5099 do you have a video on doing that ? i'm not an electrician