Load Testing Prius Modules

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.ย. 2024

ความคิดเห็น • 29

  • @dc5duben96
    @dc5duben96 หลายเดือนก่อน +1

    thanks for the video and explanation, this helps me as im currently going through my modules

  • @myfriendscott9830
    @myfriendscott9830 2 ปีที่แล้ว +2

    The thing is they are hooked up in series so when the car is pulling 30 amps it 30 per block. It is easier to understand if you convert to Watts.

    • @ZookeeperJohnG
      @ZookeeperJohnG  2 ปีที่แล้ว +1

      In series, every module (2/block) sees the 30A, yes.

    • @jayviz
      @jayviz 3 หลายเดือนก่อน

      @@ZookeeperJohnG. 30A and then some!

  • @theaussienurseflipper.8113
    @theaussienurseflipper.8113 2 ปีที่แล้ว

    My Camry ex taxi. Over 800,000kms 2010, I know the owner and he never changed the battery. I have the car 5 years. Last 12 months the code throws. First it was every couple weeks, now some days it throw 3 times in one day. But it still go weeks sometimes. Funny only at major part he change was abs. Except for tyres and oil, the only thing, I've changed is a wheel bearing in 5 years. Need a lot now. Hard choice to keep it or flick it.

  • @AMF_TRAVELERS
    @AMF_TRAVELERS 5 หลายเดือนก่อน +1

    Which company this load test? Did you have any link to buy?

  • @guidobraun2920
    @guidobraun2920 3 ปีที่แล้ว +2

    Only defective modules can be found via the voltage. With a capacity measurement, weak modules can also be found. These weak modules are among the first to be broken the next time. I found a 7.4 volt module with only 1800 mAh. Normally old modules (year 2007) have approx. 5500 to 6500 mAh.
    Here you find the way to check the capacity of your cells:
    th-cam.com/video/g5KAPge-f6E/w-d-xo.html

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 หลายเดือนก่อน

      Correct, if you will notice the title is LOAD testing, not capacity testing, they do not measure the same thing. Why load test? No point in doing a capacity test if the module cannot carry even a small load and so save huge time.

  • @jasonalexander6417
    @jasonalexander6417 3 ปีที่แล้ว +3

    Load testing with around 2-3 amps for only a few seconds? I wouldn't think that would be long enough to determine if a battery is good or not. Others have recommend 2 minutes.

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 ปีที่แล้ว +1

      Not capacity testing, load testing to find bad modules. Performing a capacity test takes a lot longer and will find OK, but weak modules.

    • @jayviz
      @jayviz 3 หลายเดือนก่อน +2

      that's such a minuscule load I find it hard to believe it's very effective. Think of the load these things are normally put under in normal use!

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 หลายเดือนก่อน

      It is super effective at weeding out failed modules that capacity testing would be a total waste of time on and that was my goal.

  • @NextStepinlearning
    @NextStepinlearning ปีที่แล้ว +1

    Thank you for the video!
    I have load test my 2012 camry battery cells with an old headlamp bulb known as h4; all calls were holding 7.45 volts range and I had meter on for 20 seconds for each cell. If cells are showing capacity where it should be then what should I check next to fix P0A80 fault code? Thanks

    • @ZookeeperJohnG
      @ZookeeperJohnG  ปีที่แล้ว +1

      If all the modules check out ok, I would suspect corrosion on the terminals, or the whole pack is just worn out.

  • @unsolvedhookup
    @unsolvedhookup 5 หลายเดือนก่อน

    0:24 Make sure you careful with that power supply. Its not a charger. Cool video, I've burned many power supplies before learning i need a charger in the middle. A nice rc charger will do

    • @ZookeeperJohnG
      @ZookeeperJohnG  5 หลายเดือนก่อน +1

      There is no power supply in this video.

  • @eddjo11
    @eddjo11 4 ปีที่แล้ว +1

    i bought a used pack. about six of them were at 7.53v. the rest were 6v , 4v, 2v and 0.45v. i replaced two bad modules with the 7.53v and my prius is good. the low volts ones, i have been trying to balance . i noticed they discharge by themselves quickly or slowly over a few minutes or in a day. the rate discharge differs. the 7.53v would not discharge at all. i did not try to balance them. i just swapped them out.

  • @physicalivan
    @physicalivan 4 ปีที่แล้ว +1

    what is the voltage it should hold under a load and without a load?

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 ปีที่แล้ว +3

      If a module is

    • @cawag98
      @cawag98 3 ปีที่แล้ว +2

      On priuschat I've seen a lot of comments that the load test should be 100W or 150W and a two minute to the second time, to get the correct results.

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 ปีที่แล้ว +1

      150w on a 7.5V battery is like 20A, no way they will take that for two minutes. I think folks are confusing the motor current the inverter produces and the battery current from the High Voltage pack, which are not at all the same thing.

  • @21boxhead
    @21boxhead 3 ปีที่แล้ว

    EVERYONE ELSE THAT LOAD TEST DOES IT LONGER
    YOURS IS TOO QUICK

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 ปีที่แล้ว +2

      To identify failed ones, this is perfectly fine.

  • @peng28
    @peng28 3 ปีที่แล้ว +1

    thanks you for video. simple explain , easy to understand

  • @felixdostie9024
    @felixdostie9024 4 ปีที่แล้ว

    I would have liked to see the voltage without load on the bad cells! Can a bad cell show suffucent voltage without load? Thank you!

    • @ZookeeperJohnG
      @ZookeeperJohnG  3 ปีที่แล้ว

      Yes they can. A truly bad cell will have low open circuit voltage, but marginal ones can show close to normal.

    • @michaelbaer5494
      @michaelbaer5494 ปีที่แล้ว +1

      I had an exploded cell. Literally black and burned and leaking liquid. Still gave me a reading of around 8 volts.