ไม่สามารถเล่นวิดีโอนี้
ขออภัยในความไม่สะดวก

Air Conditioning electrical wiring | बिना Electrician को बुलाये AC electrical wiring कैसे करे ? |

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ส.ค. 2024
  • Air Conditioning electrical wiring | बिना Electrician को बुलाये AC का electrical wiring कैसे करे ? |
    in this video i will explain you about AC electrical wiring and home main switch board wiring diagram and connection.
    Buying guide
    Anchor ding dong bell : amzn.to/3oSftmU
    Taparia screwdriver set : amzn.to/3hXcwQD
    Screwdriver 31 set key for home and laptop : amzn.to/3wBstQr
    Havells DBox x MCB for AC,WASHING MACHINE etc. : amzn.to/3upO2lt
    float switch : amzn.to/3hQgLx1
    water level controller : amzn.to/2So91Ic
    water level controller : amzn.to/3ffyCMp
    My other video..
    1) What is Apprentice || Apprenticeship || ???? Qualification ?????? || Benefit & Opportunity ..
    • What is Apprenticeship...
    2) Apprenticeship Online Registration and apply in company for apprenticeship..
    • Apprenticeship Online ...
    3) ITI Course Details || Benefits || TOP TRADES ||100% JOB ???? || Hindi
    • ITI Course Details Aft...
    4) Why Birds Don't get Shock while Sitting on Electric live wire (In Hindi)
    • Why Birds Don't get Sh...
    Social Links: [FOLLOW]
    TH-cam - / technicalpa. .
    Instagram - / technicalpa. .
    Facebook - / technicalpar. .
    Email-paresh.patel247@gmail.com
    Don't forget to SUBSCRIBE Electrical Trainer
    #ACelectricalwiring #airconditioning

ความคิดเห็น • 313

  • @AdityaSingh-ou6pd
    @AdityaSingh-ou6pd 2 ปีที่แล้ว +3

    आपका चैनल बहुत अच्छा लगा
    आप हमेशा कमेंट का जवाब देते हो बहुत सही करते हो धन्यवाद

  • @jatinsharma8808
    @jatinsharma8808 ปีที่แล้ว +3

    Yes mcb is important for ac or heater . Thank you very much BRAIN FOR IT !

  • @muhammadrahim9148
    @muhammadrahim9148 3 ปีที่แล้ว +3

    Assalamu Alaikum sir AC Ka 1 board lagane ka tarika fancy

  • @Salimbaloch1344
    @Salimbaloch1344 ปีที่แล้ว +1

    Nice 👍 good video ❤

  • @jadejavishvadeepsinh9169
    @jadejavishvadeepsinh9169 4 หลายเดือนก่อน

    Thank you brother

  • @Guddu_Fashion_Fitness
    @Guddu_Fashion_Fitness 2 ปีที่แล้ว

    Bahut bhdiya h

  • @VinayKumarsur
    @VinayKumarsur 4 ปีที่แล้ว +1

    very nice video sir. keep it up.

  • @nitinagase7992
    @nitinagase7992 2 ปีที่แล้ว +2

    घर मे जो वायरिंग होती है जैसे की फॅन का कनेक्शन उससे न्यूटरल और मेन और अर्थीग कनेक्शन ले सकते है क्या

    • @nitinagase7992
      @nitinagase7992 2 ปีที่แล้ว

      मुझे 1 टन ac के लिये 16 amp का कनेक्शन निकालाने है

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      @@nitinagase7992 वैसे तो अलग से वायरिंग करना चाहिए लेकिन अगर आपका एक ही रूम हो और इसके अंदर 2.5 wire का वायरिंग किया हो तो इसमें से ले सकते है

  • @noname_760
    @noname_760 4 ปีที่แล้ว +1

    Good

  • @arjumandvillagecooking
    @arjumandvillagecooking 2 ปีที่แล้ว +1

    Nice❤❤👏

  • @rameshchandrasahu5610
    @rameshchandrasahu5610 3 ปีที่แล้ว +2

    Agar hum direct electric board se current le toh isme load jyada hone ke bad jalne Ka khatra rehta hai ki nahin.

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว +1

      Meine jo batya hai isme itna load nahi hai isliye mein use 2 saal se chalaya hai....lekin load hoga to jal sakta hai...isliye mene dusra video bhi banaya hai ....direct main board se kaise wiring Kare....

    • @yashdewangan8745
      @yashdewangan8745 2 ปีที่แล้ว

      @@ElectricalTrainer Sir, mere main line MCB box se 2.5mm wire hi aaya hai, to kya mai ek room me 1 ton inverter AC, aur dusre room me 1-2 cooler, aur baaki 190L 5 star fridge use krenge to, MCB main line (2.5mm) single wire me hi chla sakte hain kya sir ji? Ya fir load hoke ya wire jalne ka drr to nhi rhega? Plz btaiye✌🏼🙏🏼

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      @@yashdewangan8745 long time mein wire jal sakta hai...aap ac ke liye alag se line khiche...mean main mcb box se phase neutral aur earthing ki 2.5mm ka 3 core cable ka use kijiye

    • @yashdewangan8745
      @yashdewangan8745 2 ปีที่แล้ว

      @@ElectricalTrainer Accha thank you sir ❤️✌🏼

  • @HimanshuGoswamiOfficial
    @HimanshuGoswamiOfficial 4 ปีที่แล้ว +1

    Thanks bhai.. tumne mera 1000 bacha lia..🥰

  • @shivamsinha7270
    @shivamsinha7270 4 ปีที่แล้ว +3

    bhai connection wala kaam hame krwana hoga ya ac installation wale hi kr dete hain

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว +2

      Connection alag se hi karvana hota hai...

    • @shivamsinha7270
      @shivamsinha7270 4 ปีที่แล้ว

      @@ElectricalTrainer ok thanks 👍

  • @munni6003
    @munni6003 3 ปีที่แล้ว

    Wah Bhaiya 👌👌

  • @hemantabandichhod3672
    @hemantabandichhod3672 ปีที่แล้ว

    Thank u sir

  • @anantsharma715
    @anantsharma715 2 ปีที่แล้ว +1

    Sir Ghar ke signal Face miter me 1 ton ka ac chalana ligal hota hai kya

  • @deepsahu1371
    @deepsahu1371 3 ปีที่แล้ว +2

    Men bord me NP 1mm ki ho to kya use concetion 1.5 tn ki ac ke liye NP le sakte h kya

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      Nahi....2.5mm ki hi use kijiye...varna jal jayega

  • @rahulbhattacharya8152
    @rahulbhattacharya8152 2 ปีที่แล้ว +1

    Ek 3000 watt ki geyser keliya mere ghar pe already 16 amp socket with board hai kya usme 1.5 ton ac chalega?

  • @newway365
    @newway365 2 ปีที่แล้ว +1

    Sir, Mera old fitting d.p plug indoor AC unit se 3 meter dur lga h , Use kaise connect kre a.c se , kya wire ka jod lga kr d.p plug tk pahuchade pls bataye??

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Ha kar sakte hai lekin 2.5sq.mm ka joint acchi tarah se lagake kar sakte hai.... loose nahi rehna chahiye

  • @MJMAHIWAL
    @MJMAHIWAL 2 ปีที่แล้ว +1

    main meter se wiring krni h ya fer board se b kam chl jata h

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Main meter se accha rahega...agar 1 ton ka hoga aur 2.5mmka wire hoga tabhi board se kijiye...

  • @itsarnavld
    @itsarnavld 3 ปีที่แล้ว +2

    Bhai eveready ki 2 battery se chal jayga kya ac

  • @perumalv5807
    @perumalv5807 3 ปีที่แล้ว

    Thanks sir

  • @anuragtrivedi2205
    @anuragtrivedi2205 2 ปีที่แล้ว +1

    Kitne mm ki jarurat padati ha

  • @THE.DARK.
    @THE.DARK. ปีที่แล้ว +1

    Ho bhai kali sitch board se sari wire nikal le aur upar ac ke pss kali mcb laga de

  • @prasitrai2790
    @prasitrai2790 4 ปีที่แล้ว +2

    Distribution box se lega toh acha hoga na sir.....

  • @Mrs.SharonPintoMendes
    @Mrs.SharonPintoMendes 2 ปีที่แล้ว +1

    kya AC ka main switch ON hi rakhna hota hai? please reply

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Ha on rakha sakte hai...wo depends karta hai...agar aap ne ac ke pass MCB use Kiya hoga to off rakhiya ..aur sscombine usekiya hoga to offf rakhiye

  • @vimalsharma7379
    @vimalsharma7379 4 ปีที่แล้ว +3

    Sir, main meter se line de ya mcb box jo pure ghar ke liy hai usme se new 2.5 mm copper wire ki line de

  • @kattarhindu8860
    @kattarhindu8860 4 ปีที่แล้ว +1

    𝓒𝓱𝓾𝓽𝓲 𝓱𝓲 𝓱𝓸 𝔂𝓪𝓻

  • @aleemsheikh2106
    @aleemsheikh2106 3 ปีที่แล้ว +1

    Aap ne jo bord se mcb ko taar diya h vo kitne mm ka tha
    Kya bord se 2.5 mm ka taar mcb tak de skta h ya poore ghr ke main mcb se ac ki mcb tak 4 mm ka dena padega ?

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      Agar ek 1 ton ka AC hoga to board se 2.5mm2 wire le sakte hai lekin 1.5 ya 2 ton ke liye aap main board se hi wiring kijiye

  • @atikurrahmanansari1778
    @atikurrahmanansari1778 3 ปีที่แล้ว +1

    Bhai AC ke liye ghar me earthing jaroori he kya

  • @ramansanwaria
    @ramansanwaria 3 ปีที่แล้ว +1

    1.5 ton k ac k liye 2.5 mm ka copper wire Or 32 ampeqr ka mcb sahi rhyega kya

  • @dev4rajan
    @dev4rajan 3 ปีที่แล้ว +4

    MCB 25A is in the MainBoard for the room I want to fix 1.5T AC. Also a 20A 3way socket already in the room. I have spare Voltage stabilizer for the 1.5T.
    So do I still need to buy separate 25A mcb for AC cutout ?

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว +1

      Just use 16amp MCB for ac

    • @shoaibraza9824
      @shoaibraza9824 2 ปีที่แล้ว +1

      1 ton ac = 20 A MCB
      1.5 ton ac = 32 A MCB
      2 ton ac =40A MCB

    • @rharshith25
      @rharshith25 2 ปีที่แล้ว

      Sir for 0.8 ton mcb rating

    • @AdnanHaamZa--
      @AdnanHaamZa-- ปีที่แล้ว

      ​@@shoaibraza9824 20-25 is sufficient for 1.5 ton

  • @s.kjuneja3491
    @s.kjuneja3491 2 ปีที่แล้ว +1

    Yadi hamari fitting me earthing ki wire na ho to

  • @XPOSER6949
    @XPOSER6949 2 หลายเดือนก่อน

    kya hum starter kharidne ke bajaye direct MCB use kar skte h ??? temporary ke liye ? qki abhi earthing h nahi gharme....

  • @sheshankjaiswal1186
    @sheshankjaiswal1186 3 ปีที่แล้ว +1

    Hi I need your help!!!

  • @dileshwarmunda8365
    @dileshwarmunda8365 2 ปีที่แล้ว +1

    Stater canection kaise Kare bhaiya main line se

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Ispe Maine video banaya hai playlist check kare

  • @gulshanattri9833
    @gulshanattri9833 ปีที่แล้ว +1

    Bhai Maine aj he 1.5 ton ka Ac lagwya hai kon sa switch sahi hai

  • @utkarshDdatta
    @utkarshDdatta ปีที่แล้ว

    1.5 ton 3 star daikin ac k lie Mcb knsi and socket and switch knsa use kre

  • @sheshankjaiswal1186
    @sheshankjaiswal1186 3 ปีที่แล้ว +1

    Need yr help in wiring a 1.5 ton window ac

  • @kanhaiyalalkarotiya5181
    @kanhaiyalalkarotiya5181 16 วันที่ผ่านมา

    Ac ka board wire 2.5 mm ko room ke board 1.5 mm se add kar skte hain? Kyuki Main box MCB dur hai

  • @vimalsharma7379
    @vimalsharma7379 4 ปีที่แล้ว +1

    Sir, jo old mcb box hai main meter ke bad usme se ek new 2.5 mm copper wire ki line de deta hu aur ek new mcb jo 20 A hai wo aur power pulg 20 A wo lga deta hu bt jo wire main meter se mcb box jo pahle lga hua hai uss pr koi load ki problem to ni hogi na

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว +1

      Koi problem nahi hoga...aap ki main mcb kitene ampere ki hai ??? Aur ek chiz agar aap direct meter se supply leke waha pe bhi 20amp ki mcb lagake fir direct ac ke 16amp plug mein de doge to bhi koi problem nahi hoga..Maine apne Ghare mein ask tarah se wiring kiya hai..

  • @rawraj1578
    @rawraj1578 ปีที่แล้ว +1

    I heard now that Inverter AC do not require starters. They are recommending AC box with MCB. What is your expert opinion? Is AC box with MCB enough. WHere should we install Stabilizer Before the MCB or after the MCB?
    My house is old it has only one main MCB of 32amps in which one direct 2.5mm wire is given for AC socket. RIght now I have connected it to starter. But Gelco Digital Starter is showing wrong ampere usage(double, checked with clamp meter) Also Inverter AC brand new is making humming sound very loud. Especially when it starts then it becomes quiet but not silent like regular AC.
    SO I am thinking there is fault in starter.
    Also voltage here is 218-240 in day time and at night it is contantly above 260 sometimes reaching 270. Though My Panasonic 1 Ton ac is designed to take voltage from 110 to 290
    I want to install Stabilizer before giving AC for repair or replacement under warranty.
    So I thought of only installing Stabilizer but local technicians are telling it is must to install starter. While online many companies now don't make AC starters. They only call it Motor starters.
    As per them new generation Inverter AC does not require starter. As motor starts at very low ampere and I have seen it.
    My AC starts at 0.2 then 0.5 then slowly reaches 1 and then 2. and stabilizes at 4 ampere and once cooled come down to 2 and even 1 ampere.
    So now I am confused.
    What should I do. Should I just install MCB Box and Stabelizer or should I installed all three. Because I think MCB is required for this.
    Thank you

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว +1

      Actually stabilizer is compulsory required wher power fluctuations is very high..like 160 to 280..but normal l voltage rating like 190 to 250 ... doesn't required...

  • @vimalsharma7379
    @vimalsharma7379 4 ปีที่แล้ว +2

    Sir, stabilizers 1.5 ton lg ac ke liye chahiye kya ya nhi

  • @souravpal5332
    @souravpal5332 4 ปีที่แล้ว +2

    1 ton AC lagana hain, Room main 10A ka MCB hain, Usme se line nikalke AC starter pe de sakte hain ? our earthing kya Swich Board se lena hoga ? kiuki Switch board our MCB 1 meter distance pe hain ?

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Aap separate alag hi 10amp ki mcb use kijiye..aur starter aap 16 amp ka use kar sakte ho..aur earthing to bhi dena padega...ispe meine detail mein video banaya hai...aapko room ke board se supply nahi lena hai ...apko main apka electricity board se supply aa raha hainwaha se phase aur neutral lena padega

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Mera dusra video bhi wo aap channel par jakar dekhiye....aap ko sab details mil jayegi

  • @nitishyadav3597
    @nitishyadav3597 ปีที่แล้ว

    Stabilizer jaruri hai AC mein lgana kya, ya MCB se kaam chl jayega 1t ki

  • @AlokKumar-zb6lk
    @AlokKumar-zb6lk ปีที่แล้ว +1

    2.5 Sq mm Ki Wire Me A.c Chal Jayegi

  • @ravindaryadav7653
    @ravindaryadav7653 3 ปีที่แล้ว +1

    Sir mene 1 ton ka split ac liya hu uska connection ka se lu mere gharme jo normal board waha se le sakte hai kay koi problem to nahi hogi.koi alag se connection ki leneki koi jarurat to nahi hai

  • @shivendrasingh9192
    @shivendrasingh9192 3 ปีที่แล้ว

    Sir main board ko open karke video banaye

  • @Udb95
    @Udb95 4 ปีที่แล้ว +3

    Bhaiya mcb lagana jaruri hai kya?? Simple board mai nahi chalega ac?

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว +1

      Ha jaruri hai..maga main board mein alag se mcb use ki hogi aur isme load nahi hoga to use kar sakte ho...magar wire to apko direct ac se hi lagana padega....aaj meine use pe video banay ...aap dekhiye pata chal jayega

  • @user-vk8jv6bo2t
    @user-vk8jv6bo2t 4 ปีที่แล้ว +1

    Bhai 1.5 ton ke lie kitna amp ki MCB sahi rahegi 20 ya 25 amp

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      20amp enough hai... Waise to 16amp bhi chalegi

  • @SH-ef3xp
    @SH-ef3xp ปีที่แล้ว

    I have Samsung 1.5 ton inverter AC and planning to buy a 1 ton or 1.5 ton new split ac.
    I have Polycab 6.0 sq mm wire in home. Can I run two 1.5 ton Acs and will 6.0sq mm wire bear this load? I run AC at least 15 hours daily.... if 6.0sq mm wire will not bear this load then I will buy 1ton inverter split ac. Please suggest and revert in detail... Thanks!

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      For 1.5 ton AC ..2.5sq.mm wire is enough...but you have to do separate wiring from meter ...for each AC...

  • @sushantwaghmare7756
    @sushantwaghmare7756 4 ปีที่แล้ว +1

    Hi bhai muze new ac ka point nikala hai to mai same ese hi nkalu na koi power ka problem to nhi hoga

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Connection Aisa Hi karna hai magar main phase aur neutral mein hi ac ka phase aur neutral dena ha...jaha se electricity board ka supply ata hai main phase aur neutral lena hoga...jis room mein ac lagaya hai waha ka supply use nahi karna hai..main board se phase anu neutral use karna hai

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Kal mein uspe video banani ke try karunga

  • @bullandthebeast8782
    @bullandthebeast8782 4 ปีที่แล้ว +1

    Ac yaha lagana h waha s mcb power socket 15 feet dur h . Ac ka power cable extend kr sakte h

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Agar apke ghare mein itna load nahi ho to room ke board mein bhi laga sakte hai lekin room jo wirinv kiya hoga wo 2.5mm2 wire hona chahiye....lekin present day mein hum jo main meter laga hota waha se direct bhi phase aur neutral le sakte hai..ya fir jo main MCB lagi hogi waha se bhi le sakte hai...isme wire jyada lagega

    • @bullandthebeast8782
      @bullandthebeast8782 4 ปีที่แล้ว

      @@ElectricalTrainer ac ka hi box laga hua h already scocket + mcb . Bs ac jaha install hona h waha s 10 feet dur h

    • @bullandthebeast8782
      @bullandthebeast8782 4 ปีที่แล้ว

      @@ElectricalTrainerac ka powe socket 10 feet tak badhane s koi problem toh ni ?

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      @@bullandthebeast8782 koi problem nahi hoga. Don't worry...

  • @pradipmukhopadhyay8046
    @pradipmukhopadhyay8046 11 หลายเดือนก่อน

    Nice video.. i have one question, aapne jo phase aaur neutral normal switch board se lekar mcb may connect kiya for AC, toh kya normal switch board may bhi 2.5 mm sq wire hona chahiye ya agar switch board ka connections sare 1.5 ya 1 mm sq wire se kiya hua hai phir bhi hum same switch board se phase aaur neutral le sakte hai connect karne kay liye mcb may for 1 ton AC ?

    • @ElectricalTrainer
      @ElectricalTrainer  10 หลายเดือนก่อน

      agar load jyada nahi hoga to 1.5sq.mm mein 1 ton ka ac chal jayeg ...magar how sakte to 2.5sq.mm ka use kijiye..

    • @kamleshsuthar3004
      @kamleshsuthar3004 4 หลายเดือนก่อน

      Kya neutral 1 sq mm chalega. Phase 2.5 sqmm

  • @prasitrai2790
    @prasitrai2790 4 ปีที่แล้ว +1

    sir ac ka toh alak se circuit dal ta hena ...load lega swich board say.....

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว +1

      Ha waise alag hi line karte lekin aapke board mein kuch bhi jyada load nahi hoga aur jo wire ka use kiya hoga wo 2.5mmsquare ke hoge to koi problem nahi hogi...aur aap alag lagana chahte ho to uspe bhi meine video banaya hai...

  • @Jr.Techie
    @Jr.Techie 2 หลายเดือนก่อน

    Bro agr ac ke neutral and phase wire ko change krde koi dikkt to nhi hogi

    • @ElectricalTrainer
      @ElectricalTrainer  2 หลายเดือนก่อน

      Nahi ..phase ko phase mein hi Dena hota hai..

  • @anarulislam6014
    @anarulislam6014 3 ปีที่แล้ว +1

    Malum nahuwa Earth kesa korna he

  • @throwerprince29
    @throwerprince29 ปีที่แล้ว

    Sir L OR E SE BHI START HO JATA TO JARURI HAI F LENA HOGA

  • @THE.DARK.
    @THE.DARK. ปีที่แล้ว

    Hlw bahi kali switch board se mahi ho gye kya

  • @mv5091
    @mv5091 5 หลายเดือนก่อน

    maine AC ki wire lgayi ha alag se...uspe 20Amp ka MCB lgaya hai single pole wala....ab ac ko supply kahan se deni hai?...ghar ke DIP switch MCB se ya seedha main line se connect kr dena ha wiring ko??

    • @ElectricalTrainer
      @ElectricalTrainer  5 หลายเดือนก่อน +1

      Main line se acha rahega।।।agar jyada ton AC hai to

  • @divyaprakashdixit
    @divyaprakashdixit ปีที่แล้ว

    Sirf ampere bataoge ya mm thickness bhi btaoge

  • @abhichawla143
    @abhichawla143 3 ปีที่แล้ว +1

    Sir 1.5 ton ke liye kitne mm ka wire sabse best hai aur budget mein bhi ho

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว +1

      2.5mm ka wire aram se chal jayega...

    • @abhichawla143
      @abhichawla143 3 ปีที่แล้ว

      @@ElectricalTrainer 4mm ka jada kharcha karne ki jarurat to nahi padegi na

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      @@abhichawla143 nahi....2.5mm mein aram se chalega....split AC hai kya ??

    • @abhichawla143
      @abhichawla143 3 ปีที่แล้ว

      Ji split ac hai blue star non Inverter

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      @@abhichawla143 ok

  • @STROMGAMING.01
    @STROMGAMING.01 3 หลายเดือนก่อน

    Bhai to 1.5 ton ac me 2024 model he to uspe kitne mm ka wire lagana cahiye 3 star ka he

    • @ElectricalTrainer
      @ElectricalTrainer  3 หลายเดือนก่อน

      2.5mm aur 16A / 20A type c MCB

    • @STROMGAMING.01
      @STROMGAMING.01 3 หลายเดือนก่อน

      @@ElectricalTrainer ac ke liye alag se waring lena chahiye main board se kyu ki mere main board pe 2.5 mm ka wire pada he

    • @STROMGAMING.01
      @STROMGAMING.01 3 หลายเดือนก่อน

      Boliye

  • @ipshitadas1381
    @ipshitadas1381 2 ปีที่แล้ว

    bhai thoda reply karna humare ghar se electric pole tak connection 2.5mm wire se ki gaya hai humare ghar me 1.5 ton ac lagane ki soch raha hoon kya wire 2.5 mm sahi rahega ya thoda zyada mm ki lagane ki jarurat hai abhi philal fridge , computer chal raha hai ghar mein itna hi load hai

  • @yashwanttiwari5886
    @yashwanttiwari5886 3 ปีที่แล้ว

    Sir mai 1.5 ton ka AC lagana chahta hu to jiske liye connection board se du ya main line jo miter ke pas laga usse du .

  • @SHUBHAMSHARMA-hp5iw
    @SHUBHAMSHARMA-hp5iw ปีที่แล้ว

    Sir 2 ton non inverter window AC ke liye electrician ne 2.5 sq mm ka wiring kiya hai...kya ye shi hai?
    Plz batayen

  • @vikashpanwar5
    @vikashpanwar5 3 ปีที่แล้ว +1

    A

  • @debprasadbanerjee5005
    @debprasadbanerjee5005 3 ปีที่แล้ว +1

    Sir mene ac liya hai, mera main line box, 1st floor me hai aur ac 3 rd floor me, kya 1.5 ton ka ac me switch board se direct line le sakta hu, kya stabilizer chahiye?

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      Aap main line se connection kijiye...1.5ton ac hai isliye

  • @user-qr7yk4vv7f
    @user-qr7yk4vv7f 7 หลายเดือนก่อน

    Bhai ac ka inphut wari kitne mm ka hona chaiye

  • @rajivdas8824
    @rajivdas8824 ปีที่แล้ว

    Is starter compulsory for 1.5 ton 3 star/5 star inverter AC ?

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      If you have voltage fluctuation at your place than its compulsory..

  • @anupBroLogs
    @anupBroLogs 3 หลายเดือนก่อน

    3 core Wire copper hai ya alluminium.

  • @rajarshidas5487
    @rajarshidas5487 ปีที่แล้ว

    Sir,I have one question. My AC vendor says it's not required to draw a 4mm wire from the main switch. For one AC of 1.5 ton capacity, an MCB of 16 amp is enough. As my home is already wire with 1.5 mm wire.

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว +1

      Yes it's enough but in some.case it's burnt wire so for safety use 2.5mm

    • @rajarshidas5487
      @rajarshidas5487 ปีที่แล้ว

      @@ElectricalTrainer thank you Bhai. For your reply.

  • @user-xc2qt5cu5c
    @user-xc2qt5cu5c ปีที่แล้ว

    डबल फेस मे चलता है क्या sir AC
    या सिंगल फेस मे चाल जाएगा

  • @neerajkumaonisinger9497
    @neerajkumaonisinger9497 3 ปีที่แล้ว

    Sr ismai mother board kaha pr hota hai or kya kaam krta hai

  • @pankajshrivastav9204
    @pankajshrivastav9204 3 ปีที่แล้ว +1

    Earth kaha se de

  • @GaneshGaneshsoni-iy8fb
    @GaneshGaneshsoni-iy8fb ปีที่แล้ว

    sir mera ac ka power jo h wo kam colling krne k bad v àchànk se badh jati h,sir kya kare iske liye

  • @adityasoni4007
    @adityasoni4007 3 ปีที่แล้ว

    Bhai m 1.5 ton inverter ac 2.5mm wire ka use kar satka hu kaya
    Ya 4mm use karu

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      2.5mm enough hai....check out my latest video jisme meine pura samjhaya hai

  • @vimalsharma7379
    @vimalsharma7379 4 ปีที่แล้ว +1

    Mera meter room se 80 ft door hai to aap btyo ki kya kre

  • @nileshharal2533
    @nileshharal2533 2 ปีที่แล้ว

    Sir muze ac Lena hai mere ghar mai ac point nahi bnaya hai ... To ac installation Wale ac point banke denge kya

  • @rasiksolanki7058
    @rasiksolanki7058 2 ปีที่แล้ว

    Mini MCB Mein Pahle Se Nutan fees Diye Hue to board ke liye ke liye

  • @AdnanHaamZa--
    @AdnanHaamZa-- ปีที่แล้ว

    Sir mera 1.5 ton non inverter Ac hai...
    Technician ne Ac Ka plug se Starter tak 2.5mm neutral and phase aur 1.5mm earthing kara .Uske baad starter se 20 amp ka mcb tak 10mm service wire and 1.5mm earthing kara
    (62amp for house and 20 amp for ac) Sahi hai kya?

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      Ha chalega...lekin ghare ke liye 62 amp kafi jyada rating ki rakhi ha..

    • @AdnanHaamZa--
      @AdnanHaamZa-- ปีที่แล้ว

      @@ElectricalTrainer isliya ki Main switch ke badle vo wala replace kardiya 😅62amp mcb

  • @rasiksolanki7058
    @rasiksolanki7058 2 ปีที่แล้ว

    DP switch off ke baad connection kar sakte hain

  • @flyhigh5066
    @flyhigh5066 2 ปีที่แล้ว

    Maine ac 2 saal se use nahi Kiya hai Naya Ghar me shift karne ke baad, pack kar ke rakha hai, abhi chaega ac ya repair karna padega?
    Meter se wire khichna padta hai kya, Mera meter single phase ..65 kw ka hai?

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Ha meter se khicha padega...aur ac ko technician ko batake chalu kare

  • @kushaldeepchaujar3402
    @kushaldeepchaujar3402 2 ปีที่แล้ว +1

    Bhai aam insaan ke liye video nahin hai kyunki samjhaya nahin kuchh bhi aur jaldi jaldi bhi kar rahe

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Dusra video bhi banaya hai .. channel visikare

  • @dhaggu
    @dhaggu 4 ปีที่แล้ว +2

    Sir 1 ton k ac k liy mujhe
    Technician ne 10 mm aluminum ke wire btai the..
    To mane vahi lagwai hai
    To 1 ton k liy 10 m. m aluminum theek Rahege????

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Vaise to koi dikkat nahi rahegi...10mm cable mein...kyonki wo 50amp tak load le sakta hai..

    • @ramzansama2671
      @ramzansama2671 4 ปีที่แล้ว +1

      aluminum se acha 2.5 ka coper ka laga dete

    • @dhaggu
      @dhaggu 4 ปีที่แล้ว +1

      @@ramzansama2671 ab to. Lga dala... Ab to life jhinge lala🤣

  • @ankeshsinghbais878
    @ankeshsinghbais878 3 ปีที่แล้ว

    Sir mujhe window ac 1.5 ton ka lgwana h gaon m.. electrician keh rha h ki alag se wire lgani padegi aur separate earthing bhi.. filhaal ac ghr k switch board p nhi chl pa rha h.. electrician keh rha h ki earthing weak h..
    suggest kriye sir detail m bataiyega.. village m electricity bhi low high hoti rahti h

    • @ElectricalTrainer
      @ElectricalTrainer  3 ปีที่แล้ว

      Agar electricity low high rehti hai to alag se aapko line lagani padegi...ha lekin earthing agar ghare ka use karogo to chal jayega....

  • @himansusekharkar1676
    @himansusekharkar1676 4 ปีที่แล้ว

    Baha 1.5 ton ki AC keliye 2.5mm wire use kar sekte hain Kay??

  • @kashyapdeepak7335
    @kashyapdeepak7335 11 หลายเดือนก่อน

    Ac k liye kitne mm ki wire ka use kare

  • @MS-Hussain
    @MS-Hussain 2 ปีที่แล้ว

    Mera ac direct MCB me connected hai. Kya aisa sahi hai 🤔, without socket, plug?

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Waise koi problem nahi..lekin agar koi fault ataa hai to disconnect karne mein problem hogi aur jo right procedure hai wo aap socket ya s.s.combine use kijiyega

  • @shivamrathod4989
    @shivamrathod4989 2 ปีที่แล้ว +1

    Earthing na hoto ac kam nhi krega? Anyone reply!

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว +1

      Yes it's run...means run karega leking safety nahi rahegi

  • @neelthakkar3633
    @neelthakkar3633 4 ปีที่แล้ว

    bhai ac starter buy karne k liye koi link do plz

    • @ElectricalTrainer
      @ElectricalTrainer  4 ปีที่แล้ว

      Local market se mil jayega.. Around 500rs ke under...agar branded ke 800rs

  • @Brief_knowledge
    @Brief_knowledge ปีที่แล้ว

    Sir kya me AC ke wire ko direct normal board jisme hum phone ka charger lagate hai usme lga sakte hai.😅 Pls reply

  • @mohdshaban2037
    @mohdshaban2037 2 ปีที่แล้ว

    Bhai stebilizer ke bina bhi ac chala sakte hain kya?? ... Kyuki Humare yaha light thik aati hai kam zyada nhi hoti.... Plz rply

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      Agar power ka fluctuations jyada hoga tabhi lagaye Varna lagane ki jarurat nahi hai...

    • @mohdshaban2037
      @mohdshaban2037 2 ปีที่แล้ว +1

      @@ElectricalTrainer thnax sir

  • @rayyanshaikh2176
    @rayyanshaikh2176 2 ปีที่แล้ว +1

    Wire Kitne mm ke Use karna hai??🤔

  • @vimalsharma7379
    @vimalsharma7379 4 ปีที่แล้ว +1

    Plz reply sir

  • @sauravnandy4511
    @sauravnandy4511 2 ปีที่แล้ว

    Hamare ghar mein 1.5 ton ac ke liye electrical connection karwani hay. To iske liye 10mm Service Wire ( Aluminium ) se connection karein ya fir 4mm Copper Wire se connection karein? Kismein bijli ka bill kam ayega? Sirf AC ke liye alagse MCB jaruri hay kya?

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว

      2.5 mm copper ka bhi chal jayega 1.5 ton AC ke liye...aur alag se mcb lagaye....

    • @Subhendu_31
      @Subhendu_31 ปีที่แล้ว

      @@ElectricalTrainer Sir 2.5mm or 4mm copper wire which is best for 1.5ton inverter ac?

  • @sailendrakumaragrawal
    @sailendrakumaragrawal ปีที่แล้ว

    I use only DP MCB 32amp for my 1.5 ton ac is it ok

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      16amp is enough...you. Can check my latest video on it...

    • @sailendrakumaragrawal
      @sailendrakumaragrawal ปีที่แล้ว

      @@ElectricalTrainer I have now use 32amp Dp mcb can I change it to 16amp mcb or chale ga?

    • @sailendrakumaragrawal
      @sailendrakumaragrawal ปีที่แล้ว

      Can I use 32 AMP MCB for 1.5 ton non Inverter AC

  • @yashdewangan8745
    @yashdewangan8745 2 ปีที่แล้ว

    Sir, 1 ton inverter AC k liye 2.5mm hi enough hai ya 4mm lgega.
    2. Mere main line MCB box se 2.5mm ka single wire hi lga hua hai rooms tk. Mean AC ka wiring nhi hua hai, to kya mai room k 16A power switch board se hi AC use kr skta hun, ya koi separate wire lgani pdegi.

    • @ElectricalTrainer
      @ElectricalTrainer  2 ปีที่แล้ว +1

      2.5mm enough hai ..agar dusra koi load nahi hoga to aap room se le sakte hai...lekin neutral bhi 2.5mm ka hona chahiye ...waise maine bhi room se hi liya tha...aur 2 saal tak chalaya iske baad meine alag se line khichi hai...agar sirf fan aur bulb ka hi load hoga to room se bhi chalega...

    • @yashdewangan8745
      @yashdewangan8745 2 ปีที่แล้ว

      @@ElectricalTrainer Accha, Sir, agar 1st room me sirf ek 1 ton inverter AC, aur 2nd room me 1 2 cooler aur 190L 5 star fridge chlayenge to, MCB se nikla 2.5mm pe load pdega kya, mean wire jal skta hai ya safe rhega....

  • @shuvamsingh9051
    @shuvamsingh9051 ปีที่แล้ว

    Mera electrican bol rha ye 3 core 2.5mm2 wire ko electric meter ke paas starter hai...waha se lene ke liye..isse distance bohot zyada 60mtr ho ja rha hai....isliye Mera sirf wire ka cost 6000/- rupay aa rha hai....kya Karu?

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      Agar room mein 2.5mm ka use Kiya hoga to 1 ton AC chal jayega ..nahi to fir nayi line meter se hi Leni padegi

  • @LuckyManVlog5094
    @LuckyManVlog5094 ปีที่แล้ว

    Main board se AC ka socket ke sath connection kaise huga

    • @ElectricalTrainer
      @ElectricalTrainer  ปีที่แล้ว

      अलग से वीडियो बनाया है।।। चैनल पर जाकर देखे