Gas chahe jo b hou Vacuum karna zaruri hai … and jo b vacuum ko skip karta hai shayad usse kaam thik se nhii aata yaa uske paas vacuum pump nhii houga and aalsi insaan houga vacuum nhii kar rha …😂😂😂😂😂😂😂 👍
90%Authorised service center Wale without vaccume kiye huwe AC install kar rahe hain aajkal,bolne par gol mol jabab de dete hain.customer to janta nahin kya kare.
Torque wrench not used, which means you failed to follow manufacturers instructions, over tightening or under tighten of flare nuts means damage to nuts and threads and gas will leak. You must also use Nylog Blue for thread choking or locking and gas will not leak.
But krta nai hai koi.....this Process is in the installation Process ??... Kindly confirm as i have bought split ac and gng to install in 1-2 days. Thanks!
@@kapilyadav8226 Vacuum is very important for ac to remove moisture and air from system doing which cooling and life of ac increases .Due to lack of knowledge and time consuming process most technicians avoid it.New ac also need vacuum. Force your technician to do it bcoz you are paying installation charges.
@@sarabjitsidhu6928 Vaccum process finally done after insisting many times to installation team but for 10 mints only. not sure yet for 1500 microns. But yess vacuum needle was in negative side in pressure gauge. Hope thr is not any issue.
vaccum pump should be used before gas r32 start. mix of air with R32 result ac will not proper cooling . and near feature ac compressor will be probem.
Kisi bhi bhai ko MI technical institute ka PDF chahie to humse sampark Karen MI mein Sara kawara saman se sikhate Hain kuchh nahin Sikh paoge 45 din ka course ek mahine ke andar ho jata hai samjhe bhai ka pahchan
AC agar ek jagah chal raha hai phir usako us jagah se dusari jagah lagana hai to AC ko chalate samay me gas ko band karana hai ya AC ko off karake gas band karana hai
Pipe ko to andar krna tha sir aap ko to pta tha ki pipe ko andar kiya jata h but aap bhi ase hi video bna diya.
Munna Bhai Lage Raho very nice
Bahut Sundar Bhai
Without vacuum per Aise Lagaya is bhai ne Shabash Shabash Shabash
गलत तरीका है
New ac ko vaccum kaun karta hai bhai
Aur kyun karna chahiye vaccum
Remote is like mereko kyu maar rhe ho 😂😂watch at 4:15 😂
बहुत ही शानदार नॉलेज मेंट दी है
Bahut achha laga bhai,,,,
Dusri side hol k pise v lozik hai dekho phle Bhai ne dril to Kiya tha nice work❤
Aeche✌ video 🎥 hai good👍 information💕
Dhanewad pravhu 🙏🙏
Aap apna what's app nuber desakte he 🙏🙏
Sahi hai dono sistam se bhi hota hai sir sahi bata rahe hai
Very nice bolte hai bhai aur ac ki jaankari de
Very nice video Bhai 👌
Bahut smjhaya sarji
Bhoot bariya
Sir practical video dalo apki video bahut achi hoti hai
Sar ji Aapka bahut bahut 🙏💕🙏💕🙏💕🙏💕 dhanyavaad sar ji
Very nice Bhai ji
Good work bro 😊
Gas chahe jo b hou Vacuum karna zaruri hai … and jo b vacuum ko skip karta hai shayad usse kaam thik se nhii aata yaa uske paas vacuum pump nhii houga and aalsi insaan houga vacuum nhii kar rha …😂😂😂😂😂😂😂
👍
Good commentary
अच्छी जानकारी
Sir aapka explain karne ka tarika bahot pasand hai mujhe, par wire connection samjh nhi paya mai sahi se please sir samjha dijiye please🙏
Nice video sir
आप को तो पत्रकार होना चाहिए non stop बोलते हो🥺
🤣🤣
Thanks for informative video.
Very nice video bro
Very nice video 👍 bhai on Air conditioner installation
1- vaccum nhi kya
2-union pr teflon tape nhi lgate h
3-agar pipe indoor ke andar se hi nikalte tb jayada bst rhta
4-inverter ac ka kya fayada jbki vaccum nhi kiya
5-leakage nhi check Kiya
Sir, vacuum process is in the installation Process???
Bhai kul milakar ac kya laga jaise hagg diya gaya hai aisa lag ra hai jaise kisi helper ne lagaya hai
90%Authorised service center Wale without vaccume kiye huwe AC install kar rahe hain aajkal,bolne par gol mol jabab de dete hain.customer to janta nahin kya kare.
Very nice information sir
Thank you sir Infrometion dene keliy
बहुत सुंदर टांग दिया है 😂
Video acha hai par sawdhani aur safayi se kaam karne ki jrurat hai
Information video
Good sir Ji ❣️
Nice information
Thank you sir
Sir app plz,,,, inverter ac ka full video banaye with pcb explation
Torque wrench not used, which means you failed to follow manufacturers instructions, over tightening or under tighten of flare nuts means damage to nuts and threads and gas will leak. You must also use Nylog Blue for thread choking or locking and gas will not leak.
Very Nice video Sir
TQ sir .....ac ka Full kam karne ka video v de sir
Never use ac before vacuum at least for 30 minutes or (1500 microns vacuum ).The S wire is of sensing not starting as you said.
But krta nai hai koi.....this Process is in the installation Process ??...
Kindly confirm as i have bought split ac and gng to install in 1-2 days.
Thanks!
@@kapilyadav8226 Vacuum is very important for ac to remove moisture and air from system doing which cooling and life of ac increases .Due to lack of knowledge and time consuming process most technicians avoid it.New ac also need vacuum. Force your technician to do it bcoz you are paying installation charges.
@@sarabjitsidhu6928 Thanks!!
@@kapilyadav8226 t45ttrr444
@@sarabjitsidhu6928 Vaccum process finally done after insisting many times to installation team but for 10 mints only.
not sure yet for 1500 microns.
But yess vacuum needle was in negative side in pressure gauge.
Hope thr is not any issue.
Sir eak baar split AC ki fitting karte samay indore out dore aour steblizer me kaise current dete hai please eak video bna do
Very nice sir
Mast news
Nice
S wire means signal wire not starting
Vaccum v karna chahiye ache cooling ke liye aap ek jankaar admi hai to aap galat information na de
𝗦𝘂𝗽𝗲𝗿👌👌👌👌👌 𝘀𝗶𝗿
Jab hamara बैच था तब पुराना कबाड़ा एसी था sir
Your right brother 🤒🤒🤒
Bhai yaha sahi kaam sikhaya jata hai ap sikh GAYE???
@@Dahmer6799 no waha par purana ac lawade ka ac sekhate hai kam se kam 10-12 years old model sikhate hai 🙋🙋🙋🙋
Ab market me inwetar ac aa gaya hai us k ware me kuchh nahi padate hai
@@Dahmer6799 nahi bhai ac new bus dikhane k liye लाय hai
Installation me vaccum nahi hota use pahle se gas hoti hai isliye
Or gas filling ke tim vacuum karna jaruri hota hai
vaccum pump should be used before gas r32 start. mix of air with R32 result ac will not proper cooling . and near feature ac compressor will be probem.
Sahi kaha aap ne 👌👌
Ye whatsapp university ke engineer hai, Inne naa samjhaye!
Thanks Bhai 🙏❤️🙏
Kisi bhi bhai ko MI technical institute ka PDF chahie to humse sampark Karen MI mein Sara kawara saman se sikhate Hain kuchh nahin Sikh paoge 45 din ka course ek mahine ke andar ho jata hai samjhe bhai ka pahchan
Nice sir 👍
good
Thanks sir ji
Sir self vaquem par ek video banae sir please
Bro i am request for you ki ghar ka go Earth connection kasa kare boo is topic par eak video baniya please
Sir. Mai. Aapki. Pratek. Video. Dekhata. Hu
sir vaquem ke bare me ek vidio bnaiye sir please
Mast
No vacuuming...good
Galat fitting hai kyuki pipe nhi dekh sakti thi
Sir ek bar Tv repairing ka full video bnaao
Good video. What about the Exhaust Fan on the same wall? Model of the AC?
Hi moja
Bhai g s wire signal wire hoti h na ki starting
AC agar ek jagah chal raha hai phir usako us jagah se dusari jagah lagana hai to AC ko chalate samay me gas ko band karana hai ya AC ko off karake gas band karana hai
अरे चाचा जो टेक्निशियन एसी खोलने आता है, उसे पता रहता है और हान एसी चालू करके ही गैस बंद कर जाति है
Sir deep freezer ka internal lik pe video banaye sir plzzzzz
Thankyou
पतला और लम्बा होता है उसको बोलते है इंडोर🤣🤣🤣🤣🤣
Thanks
Ac shi nhi lgi h sir pipe nhi dikhna chaye tha indor ke plait ke just hol krna chaye tha sir riply dejiyega
Yes
Bilkul sahi kaha bhai
👍👍👍👍👍👍
Sahee kaha bhai isse acha saaf mai laga deta huu ause lagaya hai jaise hagg diya gaya hai
New technician lag rha hai bro😂😂😂
Outdoor unit ke dono pipe , wire Pani Bala pipe indoor unit ke left side nikalte h ki right side ya dono side me se kisi bhi side me nikal sakte h
Motar pump ka ek video banaye sir
❤❤❤❤❤❤❤❤❤❤❤❤❤
Outdoor को छत पर लगाया है क्या उसको छत पर ऐसे ही रखना चाहिए या स्क्रू / पेच से Tight कसकर लगाना चाहिए
Koi fark nhi padta itt bhi rakh skte hai
bhai tape se leak band nahi hota. vo copper ki pipe apne aap roke leti h
Bhai thodaa km or prkt bolegaa naa to badhiyaa rahegaa
The air of the indoor pipes should have been released before opening the suction line.
Compressor theek se kaam nahi karega vaccum karna chahiye tha.
Guru g hole nahi dikhna chaiye
indor ke andar hona chaiye tha
Right
𝗦𝘂𝗽𝗲𝗿👌👌👌👌 𝗔𝗰 𝘀𝗶𝗿
Sel Vaquem hi krle te sir ab se krlena 🙏
Best book for Electric Engineers ?? Jisko padh kar basic chize + interview ka preparation ho jaye.
Rate bahut jyade hai
Sab acha se samjhaya but pipe Indore ke piche se hi le sakte they aap..
मकान मे प्लास्टर जरुरी था या AC?
Jinda rahega to plaster 4 mhine bad kra lega garmi bhot jda h abi ac jaruri tha😂
Sir ji cr22 Compressor ke bare me btaye aur really ke bare me bhi
5 inch k kamzor wall par AC ko mount kiya ja sakta hai kya plz bataye
Gas kholne se pehele vacuum karna chahiye tha
Gas refilling ki videos with details daliya
Pipe ka air to andar Raha giya, vacuum kue nahi kiya ?
Nice work exauste fan kyae
Outdoor unit me rubber pads kui nahi lagaya
बिना वेकयुम पम्प A.c को वेकयुम कैसे करें सर इस पर विडियो बनाओ सर
Sir bike wiring ke bare me video banai please
Vacuum nahin karogi to install Sahi kaise hoga .
Sir tower ac package ac ductable ac ka video banaiye please wiring ke sat
I'm waiting
एक ऐसी में कितना ग्राम गैस भराएगा सर उसका एक वीडियो बनाई और कितना एंपियर लेने से सही चलेगा
guru ji sabse bhle ye btana chaye ac kholne se pahle CBU code chek kr lane chaye agar invetior model hai to