Delta VFD Factory Reset, Basic Set Up, Digital Keypad Start Up, Parameter Reset VFD-E. Potentiometer

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 พ.ย. 2024

ความคิดเห็น • 32

  • @wilfredosilva9476
    @wilfredosilva9476 3 ปีที่แล้ว +21

    I want to thank you for posting this.
    I have one on a York unit. They send the book but no instructions on how to access correctly.
    I was 14 hrs into this job. When I finally found your video

  • @xbeaureliqz9913
    @xbeaureliqz9913 7 หลายเดือนก่อน +2

    Thanks, mate. I was having trouble getting the VSD to adjustable frequency, which I then followed your video and set the potentiometer. Most appreciated!

  • @fifidanlisa89
    @fifidanlisa89 หลายเดือนก่อน +4

    Thank you for the information and knowledge, always be successful.

  • @luismiguelmartinez8245
    @luismiguelmartinez8245 ปีที่แล้ว +3

    Hello, after a long time I saw your post, I'm just starting the configuration and about your question about the fan, if it's still necessary, you have the answer in pr 03 08. Excellent video, thanks.

  • @madalinpetrisor9686
    @madalinpetrisor9686 3 ปีที่แล้ว

    Foarte bun,salut din România Mulțumesc 🙏

  • @talyaziraat4294
    @talyaziraat4294 11 หลายเดือนก่อน

    Its very helpful. Thank you.

  • @EtyakJohnson
    @EtyakJohnson 9 หลายเดือนก่อน

    Thank sir good explanation fan run cool all device inside motor

  • @javidvossough9540
    @javidvossough9540 2 ปีที่แล้ว

    Thank you for this video. I have a woodturning lathe which has this unit preconfigured and I cannot hear the fan running all the time. I was looking through the parameter manual and found the default is fan on always, you could change it with 03.08 parameter to come on when motor is running.

  • @omrishaltiel4632
    @omrishaltiel4632 3 หลายเดือนก่อน +2

    hi thanks for the video. for the fan use settings 03.08

  • @eduardoalvarado8720
    @eduardoalvarado8720 3 ปีที่แล้ว

    Hi friend, the explanation is very important ... thankyou man. Bye.

  • @skyaseman5561
    @skyaseman5561 2 ปีที่แล้ว +2

    Hi dear.
    U asked about the fan.
    I've got different model which has aluminium cooler on back to absorb the heat.
    Uk standard model come with cooling fan which most works continuously.
    I think if u look at the book u will find an option which blong to ambient temperature. Fan not working at any time .
    Good luck

    • @sjp1285
      @sjp1285  2 ปีที่แล้ว +1

      Thanks for Information.

  • @roddychisholm552
    @roddychisholm552 2 ปีที่แล้ว

    Thank you, I have a secondhand machine no doc,s great help.

  • @robdefietser6117
    @robdefietser6117 3 ปีที่แล้ว +2

    The switches behind the keypad have nothing to do with "Ready" "Run" "Fault". Switch 1 locks the drive to 50Hz max, switch 2 locks the drive to "free run to stop" and switch 3 to ACI freq. input. I suggest downloading the full manual or read it on the supplied disk. The paper manual is just a basic parameter list.

  • @horizontalkipper5832
    @horizontalkipper5832 2 ปีที่แล้ว

    I have the Delta VFD-EL UK version. fan control is function 03.08 perhaps you have similar option in the book?

  • @runbou3485
    @runbou3485 ปีที่แล้ว

    Thankអរគុណ👏

  • @Roger7137
    @Roger7137 ปีที่แล้ว

    Thank you so much!

  • @lochuynh3305
    @lochuynh3305 2 ปีที่แล้ว

    Hello
    I just bought a new DEVFD150C43E
    C 2000 delta.
    It is display a Fault overload ov at Decel.
    Can u Pl tell me how yo overcome this problem?
    Thanks
    Loc

  • @phongnghiemquoc2010
    @phongnghiemquoc2010 2 ปีที่แล้ว

    hi, could you help use "auto tuning" model?

  • @RUSHTheyellowbelt_.-
    @RUSHTheyellowbelt_.- ปีที่แล้ว

    good evening sir. may i know the unit of F.15.0 from the screen of the vfd e? is it rpm?

    • @mindaugasv85
      @mindaugasv85 ปีที่แล้ว

      F - preset frequency (Hz)

  • @philipmusyoki1687
    @philipmusyoki1687 11 หลายเดือนก่อน

    My machine is showing transmission failure what could be the problem with settings

  • @jaytownley72
    @jaytownley72 ปีที่แล้ว +1

    03.08 = Fan control

  • @ajstander2016
    @ajstander2016 3 ปีที่แล้ว

    Fan will run continuously to keep the unit temperature stable.

  • @mahendrameena8729
    @mahendrameena8729 3 ปีที่แล้ว +1

    Sir delta VFD error acl come in display

  • @kiranchoudhari4717
    @kiranchoudhari4717 3 ปีที่แล้ว

    You dont set motor data after reset the drive,, please explain

  • @phongnghiemquoc2010
    @phongnghiemquoc2010 2 ปีที่แล้ว

    how to change parameter of motor? ex: kw, ampe, pole...

  • @EtyakJohnson
    @EtyakJohnson 9 หลายเดือนก่อน

    Fan run to cool device inside drive

  • @thetooth
    @thetooth 3 ปีที่แล้ว +1

    first time playing with the variable frustration device huh?

  • @dhayacreations243
    @dhayacreations243 3 ปีที่แล้ว

    How can i remove pasword i forgot it please reply

  • @SoutheastHVAC
    @SoutheastHVAC 2 ปีที่แล้ว

    I am not a fan of these lol

  • @jambaldorjjambalbavuu3415
    @jambaldorjjambalbavuu3415 ปีที่แล้ว

    L