    @aleksandrahadzic4785 2 ปีที่แล้ว +2

    I've got a Delta EL series VFD that's been in service for a year. It's been and still continues to work flawlessly.
    However I'd like to change the accel/decel parameters.
    I'm unable to read or update any parameter. Every parameter reads as zero and any update produces an ERR.
    An example would be 00.06 which should show the software version, it reads 0.
    I've tried to update 01.09, 01.10 which should have a default of 10, but show zero. I'm able to change the value to whatever I want, but hitting the enter button to save the value produces an ERR.
    00.02 which is the Parameter Reset displays a 0 and like other parameters doesn't allow an update.
    Does anyone have an idea what is wrong and how to go about correcting it???

    • @starautomation
      @starautomation  2 ปีที่แล้ว

      Try changing parameters when vfd is in stop mode.
      Next, try to reset the vfd to factory setting and then change required parameters.
      Hope it helps

  • @mmgupta4707
    @mmgupta4707 ปีที่แล้ว

    Driv me electric connection kaise kare

  • @chandrakantpoilkar5319
    @chandrakantpoilkar5319 2 ปีที่แล้ว

    how to rev direction

  • @sssethi5148
    @sssethi5148 3 ปีที่แล้ว

    Is this on off switch can be used for 3phase vfd ????

  • @ezajahmed3008
    @ezajahmed3008 ปีที่แล้ว

    I try many times but couldn't reset my EL W drive plz solve this problem

    • @mindaugasv85
      @mindaugasv85 ปีที่แล้ว

      What do you mean "reset"?

  • @vemurirao1362
    @vemurirao1362 2 ปีที่แล้ว

    How use reverse and forward options in this drive

    • @starautomation
      @starautomation  2 ปีที่แล้ว

      It can be done by parameter setting. We will discuss about vfd parameters in the next video

  • @arshiansari3951
    @arshiansari3951 2 ปีที่แล้ว

    Hello
    Timer ki application use krne ke liye
    External TIMER ka kaise use kr skte he drive ke sath.

    • @starautomation
      @starautomation  2 ปีที่แล้ว

      If you want to provide delay in starting VFD, then use timer Normally Open contact command in series with VFD start command.

  • @rajneesh08
    @rajneesh08 ปีที่แล้ว

    Lenze Drive ka parameter delta me kaiae setting karee

  • @PeterCullen-c2m
    @PeterCullen-c2m หลายเดือนก่อน

    Thank you

  • @tikamchandsahu2787
    @tikamchandsahu2787 2 ปีที่แล้ว

    22 frequency se niche me motor nhi ghumta uske liye kya kare plz bataiye sir

    • @starautomation
      @starautomation  2 ปีที่แล้ว

      May be the vfd is not able to power the load at freq. Lower than 22Hz.
      One way is to use one rating higher vfd model.

    • @tikamchandsahu2787
      @tikamchandsahu2787 2 ปีที่แล้ว

      @@starautomation dusri machine me same moddel laga h usme 15 frequency me bhi chalta h.. Delta ms300

  • @rohanpatil5428
    @rohanpatil5428 3 ปีที่แล้ว +1

    Please send me information for rotary switch

  • @uzairali6875
    @uzairali6875 3 ปีที่แล้ว

    Please make a series of videos on this vfd.

  • @siddayya-swamy
    @siddayya-swamy ปีที่แล้ว +1

    Nice

  • @Roshanyadav-xc2sb
    @Roshanyadav-xc2sb 2 ปีที่แล้ว

    Sir mera meter kam nhi kar rha plz koi uppye batao

    • @starautomation
      @starautomation  2 ปีที่แล้ว

      If you have connected power and the meter is not powering up, then it is hardware fault in meter and it should be repaired or replaced

  • @Csolution
    @Csolution ปีที่แล้ว +1

    Good

  • @gauravbharti6622
    @gauravbharti6622 2 ปีที่แล้ว

    nice description

  • @patricktaty9276
    @patricktaty9276 7 หลายเดือนก่อน

    Hello I have a delta which is blocked even to resolve it does not work the problem is or please thank you for the re

  • @runbou3485
    @runbou3485 ปีที่แล้ว

    Thankអរគុណ👏

  • @najirnajir3247
    @najirnajir3247 2 ปีที่แล้ว

    Sukriya sri

  • @ankitvishwakarma1457
    @ankitvishwakarma1457 3 ปีที่แล้ว

    Off Time kam kaise kare

    • @starautomation
      @starautomation  3 ปีที่แล้ว

      Adjust the parameter named DECELERATION TIME

  • @PritamSingh-sk8ky
    @PritamSingh-sk8ky 2 ปีที่แล้ว

    Sir.dovol ki ac drive ki programing ki video send karo ji

  • @electricaljob7626
    @electricaljob7626 2 ปีที่แล้ว

    Thanks

  • @avnishsinghparihar2256
    @avnishsinghparihar2256 9 หลายเดือนก่อน

    Program parameter ka PDF bhej denge sar

    • @starautomation
      @starautomation  9 หลายเดือนก่อน

      Email me
      satya.starautomation@gmail.com

  • @babu-di7oi
    @babu-di7oi 2 ปีที่แล้ว

    👍👍👌

  • @uzairali6875
    @uzairali6875 3 ปีที่แล้ว

    thanks.vfd par or b videos bnae please.

  • @giuseppearena7760
    @giuseppearena7760 4 หลายเดือนก่อน

    Video in italiano

  • @LatestGadgets2021
    @LatestGadgets2021 3 ปีที่แล้ว

    Nice video

  • @mahalaxmidiselservicepinku5122
    @mahalaxmidiselservicepinku5122 2 ปีที่แล้ว

    ph no dijie

  • @indu-ux6nw
    @indu-ux6nw ปีที่แล้ว

    Sir mujhy apka number chahiye mere pass delta ka vfd hy ous ko speed badhani hy