How to Install a Combination Boiler/Water Heater | Ask This Old House

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 พ.ย. 2015
  • This Old House plumbing and heating expert Richard Trethewey replaces a water heater and boiler with a single unit that's much more efficient. (See below for a shopping list, tools, and steps.)
    SUBSCRIBE to This Old House: bit.ly/SubscribeThisOldHouse
    Richard replaces an old water heater and heating boiler with a single unit that is much more efficient.
    Shopping List for How to Install a Combination Boiler/Water Heater:
    - Plywood panel, used for mounting new combination boiler[BR]
    - Combination boiler/water heater, including mounting hardware
    - PVC pipe and fittings
    - Outdoor temperature sensor
    - PVC condensate line with limestone neutralizer
    - Condensate pump
    Tools List for How to Install a Combination Boiler/Water Heater:
    - Screwdriver
    - Drill/driver with 4-inch hole saw
    - Tape measure
    Steps for How to Install a Combination Boiler/Water Heater:
    1. Mount a plywood panel to the basement wall to serve as a mounting panel for the new combination boiler.
    2. Run new gas, electrical, and plumbing lines to the plywood panel.
    3. Screw the metal mounting brackets to the plywood panel, then hang the combination heater onto the brackets.
    4. Drill two 4-inch-diameter holes through the house wall for the exhaust vent and air intake vent. Be sure the air intake is above the snow line, and that the exhaust vent is 12 inches from a window and 12 inches from the air intake.
    5. Use PVC pipe and fittings to create the exhaust and air intake vents. Run the piping from the boiler through the exterior wall.
    6. Connect hot- and cold-water lines to the combination boiler to deliver water to the heating system and the domestic water fixtures.
    7. Connect the gas line and new electrical cable to the combination boiler.
    8. Mount an outdoor temperature sensor onto the north side of the house to help regulate the production of hot water.
    9. Run a PVC condensate line with limestone neutralizer from the combination heater to a nearby utility sink drain or floor drain. Use a condensate pump to drain away the excess condensation.
    10. Turn on the combination boiler, and it should immediately start making hot water.
    11. Remove and discard the old boiler and water heater.
    Expert assistance with this project was provided by Barry Cullen of Comfort Technology [www.comfort-technology.com/].
    Richard and Barry installed a condensing wall-mounted boiler, model number E75C, manufactured by Rinnai [www.rinnai.us/]
    About Ask This Old House TV:
    Homeowners have a virtual truckload of questions for us on smaller projects, and we're ready to answer. Ask This Old House solves the steady stream of home improvement problems faced by our viewers-and we make house calls! Ask This Old House features some familiar faces from This Old House, including Kevin O'Connor, general contractor Tom Silva, plumbing and heating expert Richard Trethewey, and landscape contractor Roger Cook.
    Looking for more step by step guidance on how to complete projects around the house? Join This Old House INSIDER to stream over 1,000 episodes commercial-free: bit.ly/2GPiYbH
    Plus, download our FREE app for full-episode streaming to your connected TV, phone or tablet: www.thisoldhouse.com/pages/st...
    Follow This Old House and Ask This Old House:
    Facebook: bit.ly/ThisOldHouseFB
    Twitter: bit.ly/ThisOldHouseTwitter
    bit.ly/AskTOHTwitter
    Pinterest: bit.ly/ThisOldHousePinterest
    Instagram: bit.ly/ThisOldHouseIG
    bit.ly/AskTOHIG
    For more on This Old House and Ask This Old House, visit us at: bit.ly/ThisOldHouseWebsite
    How to Install a Combination Boiler/Water Heater | Ask This Old House
    / thisoldhouse
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 547

  • @marcosmota1094
    @marcosmota1094 5 ปีที่แล้ว +30

    I know it's an old video, but it's nice to see Roger!

    • @jnictv1075
      @jnictv1075 3 ปีที่แล้ว

      Where in this video is Roger????

    • @jakegardiner6304
      @jakegardiner6304 3 ปีที่แล้ว +1

      @@jnictv1075 the end of the video... did you even watch it?

  • @Lionscall111
    @Lionscall111 ปีที่แล้ว +6

    I loved how they picked up the unit by its internal and valuable sensitive parts to hang on the wall.

  • @PatrickvanderStoop
    @PatrickvanderStoop 6 ปีที่แล้ว +4

    this one i love, because this heater is made in the Netherlands... so two things i love the most... America and the dutch heaters..... great show guys..

  • @Anakwad
    @Anakwad 5 ปีที่แล้ว +5

    Thanks for the information ! I love This old house.

  • @etem.a.4974
    @etem.a.4974 3 ปีที่แล้ว +3

    That basement is so neat ... Organized .... Wow...

  • @omaxman1
    @omaxman1 7 ปีที่แล้ว +1

    can't stop watching these videos..

  • @paulg444
    @paulg444 5 ปีที่แล้ว +9

    I like the old cast iron system.

  • @edyflorida6344
    @edyflorida6344 6 ปีที่แล้ว

    i m so happy follow ask this old house on youtube

  • @jacob60617
    @jacob60617 3 ปีที่แล้ว +8

    I had one install on my home. It’s really good. But can be expensive to maintenance if it breaks down

  • @CastleBomb44
    @CastleBomb44 3 ปีที่แล้ว

    Ok I am convinced. I really want my first house to have a Gas Combination Boiler/Water Heater

  • @reubenyoder6990
    @reubenyoder6990 6 ปีที่แล้ว +9

    Use a Navien combi boiler and you can vent it with 2 inch pipe.

  • @GalaXy808
    @GalaXy808 8 ปีที่แล้ว +2

    wow? I got it,sounds like better than the regular water heater

  • @SureShotImages
    @SureShotImages 5 ปีที่แล้ว +2

    Clean install boys! #Nice.

  • @tre2472
    @tre2472 7 ปีที่แล้ว +4

    would you recommend the water in this system be treated? like a water softener?
    cast aluminum?

  • @Ringele5574
    @Ringele5574 4 ปีที่แล้ว

    Thanks TOH for posting some of your programming. I really enjoy them. Please don't listen to all of these 15 y/o experts in the comments.

    • @mnf65
      @mnf65 4 ปีที่แล้ว +2

      15+ years of experience not age. I would never vent that close to a window. Code is bare minimum, always try to exceed code.

  • @victorguery1492
    @victorguery1492 4 ปีที่แล้ว +3

    Do I need an external pump for the heat loop? Of is the internal pump strong enough for 3 zones?

  • @heroknaderi
    @heroknaderi 3 ปีที่แล้ว +1

    Incredible

  • @billdohinuk2679
    @billdohinuk2679 4 ปีที่แล้ว

    What about having one of these in my diy RV? Have heated floors and hot water, all-in-one?

  • @larrycurrier290
    @larrycurrier290 3 ปีที่แล้ว +2

    I'd like to see a video of years later and see just how happy this lady is with this thing. Don't ask somebody that's just put one of these in how they like it asked somebody that's had one for a while. This thing is very low water capacity I can imagine this thing having some amount of thermal shock when it sucks that nice cold water back from the system.

    • @OMGWTFLOLSMH
      @OMGWTFLOLSMH ปีที่แล้ว +1

      They've been using these units all over Europe for decades. Americans are so set in their ways and resistant to change. They sized the unit for her hot water requirements and the size of her house. Not sure what you mean by "very low water capacity". I bet you're a climate change denier and anti-EV too.

    • @larrycurrier290
      @larrycurrier290 ปีที่แล้ว

      @@OMGWTFLOLSMH as a 40-year plumbing and heating guy I probably know a little bit more about this than you do pal. As far as climate change goes, there was an ice age before there was an automobile And you're into electric vehicles I guess you don't realize where electricity comes from number one and number two the kids that died in mines mining lithium and cobalt for your Tesla. If you don't know anything about the life expectancy of certain heating equipment then you probably shouldn't say anything at all.

    • @joecliffordson
      @joecliffordson หลายเดือนก่อน

      @@OMGWTFLOLSMHwtf. You could not have just quit at Europeans have enjoyed these for years? Who hurt you so bad you have to jump to conclusions about a little question. Then you go on to use the most divisive terms possible that have no meaning. Tell you what. That attitude does not sell conservation. Good ideas that deliver what the consumer wants sell conservation . What is a climate denier anyway? You mean like those residing at the space station? Get with the program and sell the idea of responsible care for our planet if you want to be conservation minded. It takes a lot more than pointing and saying climate denier. EV denier. Maybe you need a psychiatrist.

  • @1chish
    @1chish 8 ปีที่แล้ว +43

    I first fitted a German made Vaillant combi boiler over 35 years ago here in the UK. It lasted longer than my marriage at 20+ years! I have fitted a few other makes for friends. Ideal, Baxi, Worcester (Bosch). All have lasted with annual servicing to keep them 100%. Last one I fitted was an Ideal Logic 30, cost me about £750 ($1060) and I fitted it in 2 days replacing a 30 year old floor mounted Mexico. Have to say the UK flue and intake systems seem to be far better than that US version. You hardly notice them as they combine the two into one pipe. Different Regs I suppose.

    • @H4zuZazu
      @H4zuZazu 6 ปีที่แล้ว +3

      And the combined flue pipe is more efficient, couse of Heat recover to preheat the combustion Air.

    • @RossKempOnYourMum01
      @RossKempOnYourMum01 6 ปีที่แล้ว +1

      What's your gas safe number?

    • @AMD1
      @AMD1 5 ปีที่แล้ว +6

      Grumpy Electrician They're called Concentric vents in North America, and they're commonly used.

    • @gfriedman99
      @gfriedman99 5 ปีที่แล้ว

      AMD1 nobody has them

    • @grizzlybear2702
      @grizzlybear2702 5 ปีที่แล้ว +6

      1chish its very sad that in today’s modern world a boiler can be more loving and caring than a wife

  • @Shao-wen_Wu
    @Shao-wen_Wu 4 ปีที่แล้ว +10

    "Can it heat the house and produce domestic hot water at the same time?" thank you for including that question, I have that one too.

    • @caru3257
      @caru3257 4 ปีที่แล้ว

      It has priority for hot water.

    • @autonomy5649
      @autonomy5649 3 ปีที่แล้ว

      The internal diverter valve reroutes the water either to space heating or water heating. The space heating water basically starts to cool off during a call for hot water. In the worst case, if someone takes a long shower, you'll have barely any heat for that time. Maybe some day someone will put in a valve that can be partially open and the boiler just modulates up to handle the load.

    • @M13x13M
      @M13x13M 2 ปีที่แล้ว

      No, you need a combo core with a water tank to do that.

  • @dfiore916
    @dfiore916 3 ปีที่แล้ว

    Is that thermal backing necessary? I wasn't sure if that was for code, aesthetics, or practicality.

  • @TheOneWaja
    @TheOneWaja 6 ปีที่แล้ว +15

    Im from the UK. i have a Vailant turbomax 242, over 10 years old in my home. im a gas engineer and have barely had to touch my boiler other then to service it. Get your boiler serviced yearly, properly and it should last many years like mine. many new combis are made to break. however there are a few good new boiler makes out there which will last years. for example, the new Baxi range. Make sure your boiler has rigid materials such as copper and brass and my word, what a range of boilers they have. very innovative. i recommend all to have a look. easy to maintain and repair, what can go wrong!

    • @tommytmt
      @tommytmt 3 ปีที่แล้ว

      How do you feel about Rinnai and/or Naven? I’m in the US and I’m not aware of whether or not we can get Baxi here. I don’t know of any contractors who install them in my area. I’ve heard of them and from what I’ve heard they’re fantastic units, I’m subscribed to a HVAC contractor from the UK.

    • @juanfernandez1180
      @juanfernandez1180 3 ปีที่แล้ว +1

      @@tommytmt stay away from navien very fragile units I've installed many the stainless steel heat exchanger is horrible gets clogged very quickly and the acidic byproduct of the unit will eat through the heat exchanger quicker than other units I've installed. Being a plumber myself I just installed a cast iron unit and it's amazing never gives me problems like the wall hung units do and run it at 83 percent efficiency... wall hung units are great on efficiency but what's the point of you'll end up having to change it in 5 -7 years which I've done many so... and that's with maintenance can't imagine how long it'll last without...

  • @Maxid1
    @Maxid1 8 ปีที่แล้ว +91

    4:43 "Ok Ma'am, let me explain the hydra you have sticking out of the side of your house."

    • @thatoneukrainian649
      @thatoneukrainian649 6 ปีที่แล้ว +2

      And it was on market, this is rinnai q series, and they have good termination kits.

    • @guzman9011
      @guzman9011 5 ปีที่แล้ว +3

      Yeah they could of just installed two down facing pipes about 15 inches apart

    • @harrisonherring9194
      @harrisonherring9194 4 ปีที่แล้ว +5

      we have Coaxial flues in the UK for all boilers. does the job of exhaust and intake, whilst looking so much cleaner on the wall.... those two pipes are so ugly... or why not just move them apart, with a flat vent???

    • @squidproquo2241
      @squidproquo2241 4 ปีที่แล้ว +1

      OK Idiot let's hear what your problem is.

    • @squidproquo2241
      @squidproquo2241 4 ปีที่แล้ว +1

      @@harrisonherring9194 _ Or, why focus on the looks of the pipes instead of their efficiency? This mentality that focuses on how pipes looks like instead of their function is uglier than the pipes ... Even when it comes from a social class focused Britishit

  • @joshuacassino7297
    @joshuacassino7297 2 ปีที่แล้ว +1

    What’s a great combo brand?

  • @CRgamingMSFS
    @CRgamingMSFS 2 ปีที่แล้ว

    I bought a lochinvar noc199n. Mine did not come with the black peice yours has underneath. Do I still use the old circulator pump? Also, on the old boiler the out and return pipes were kept separate. The diagram shows a bypass pipe. With the bypass pipe how does the water get forced into boiler and not just circulate cold water?

  • @verbotn
    @verbotn 3 ปีที่แล้ว +5

    When I install condensing gas appliances, I will put the air intake and exhaust as far apart as possible. It made me cringe to see them putting the two side by side as that increases the chance of the air intake being subject to frost closure during extremely cold weather, when some of the moist exhaust is re-ingested and creates a hoar frost accumulation in the air intake. When the air intake is partly or entirely blocked by frost or any foreign material, a sensitive air-pressure safety switch will prevent the appliance from firing. The region they're installing in might make this less likely, but I'm in Calgary, Alberta so we do get some very cold spells during winter where this is a factor. If I am installing multiple condensing gas-fired appliances, I will bank all of the intakes together and all of the exhausts together with as much space between them as site conditions allow, though generally 6' is plenty. There is usually a prevailing wind direction, so I'll install the intakes upwind of the exhausts for the same reason.
    This past winter I had an interesting service call at a clients where his condensing gas furnace was not firing, upon arrival it had a fault code indicating a combustion air problem and I could hear whistling around some of the burner enclosure, so I suspected something blocking the intake. I went outside and found a plastic packaging 'pillow' from an Amazon package that had become lodged in the air intake, that was a new one, random garbage blowing in the wind that plugged the combustion air pipe.

  • @46fd04
    @46fd04 8 หลายเดือนก่อน +1

    I just had a similar unit installed at a family member's home. The company did not install the outdoor temp. sensor. They said it causes too many problems.

  • @smartchip
    @smartchip 5 ปีที่แล้ว

    In which areas or states do heated hot water systems? Intergas are the best combiboilers,

  • @heslind
    @heslind 5 ปีที่แล้ว +5

    Can’t wait to have one of these installed in my house

    • @heslind
      @heslind 3 ปีที่แล้ว

      @Kevin Edwards sorry to hear this. How often does yours have issues(

    • @wileecoyote5749
      @wileecoyote5749 3 ปีที่แล้ว

      DO NOT DO IT

    • @heslind
      @heslind 3 ปีที่แล้ว

      @@wileecoyote5749 haven’t yet but will need to replace current boiler soonish. What do recommend

    • @simpleagain1
      @simpleagain1 ปีที่แล้ว

      @@wileecoyote5749
      W
      H
      Y
      ?

  • @Danny-fs1hk
    @Danny-fs1hk 2 ปีที่แล้ว +1

    Love this show!

  • @onyxe.s.4349
    @onyxe.s.4349 8 ปีที่แล้ว +11

    we have had them in the uk for over 20 years

    • @onyxe.s.4349
      @onyxe.s.4349 8 ปีที่แล้ว

      i don`t like the venting it`s bad

    • @briancnc
      @briancnc 8 ปีที่แล้ว +1

      +ONYX E.S. There has to be a more aesthetic way to vent that, I agree the PVC elbows like that are by no means attractive.

    • @acardboredbox
      @acardboredbox 8 ปีที่แล้ว

      +briancnc being white they look bad, but paint them black or the house color and they'd look fine.

    • @Sawashi32
      @Sawashi32 8 ปีที่แล้ว

      Congrats to you and the UK but these things are junk anyway.

    • @MKRM27
      @MKRM27 8 ปีที่แล้ว +5

      +Sawashi32 They aren't junk in the UK; perhaps they're just better quality engineering. As for the venting, I've never seen one like that.

  • @charlesstevensEnki
    @charlesstevensEnki 6 ปีที่แล้ว +5

    Once the scale is built up in the heat exchanger efficiency will drop. I like the separate heat exchangers just in case they have to replaced.

    • @morbo3000
      @morbo3000 5 ปีที่แล้ว +2

      Descaling by periodically pumping an acid (usually vinegar) through the heat exchangers is recommended if you live in an area with hard water. At 5:25, you can see that there are fittings installed for just that purpose.

  • @ukar69
    @ukar69 4 ปีที่แล้ว

    I’ve got a combi boiler that sits outside. Trouble is mice decided to use it to nest in. There’s no visible gaps but they still got in. It stinks when you open it.

  • @matthewkromer9256
    @matthewkromer9256 4 ปีที่แล้ว +2

    I love my new heating system.... don't mind my pos rusty air conditioner...

  • @peterryan7827
    @peterryan7827 6 ปีที่แล้ว +1

    We are at prsent deciding on a combi type boiler ,and enjoyed this very helpful video,i wonder could you explain to us what those other pipe connections units you have had to fit underneath the boiler ,one i assume is a pressure vessel and may be a non return valve,but you have a massive cast iron unit on the gas,hope you did not mind my asking,

    • @Slowhand871
      @Slowhand871 4 ปีที่แล้ว

      There is no cast iron on that unit.

    • @goudsekaas5673
      @goudsekaas5673 4 ปีที่แล้ว +1

      From left 2right:
      - outgoing hot water for heating
      - outgoing hot water for shower and sinks
      - incoming gas
      - incoming cold water
      - return of the hot water from heating

  • @michaelsmith9034
    @michaelsmith9034 2 ปีที่แล้ว +1

    Homeowner will probably regret removing that old boiler. Far more dependable.

  • @proverbs2life
    @proverbs2life 3 ปีที่แล้ว +7

    Combi units can definitely appease almost any home. They are able to be installed in a cascade to add more than one unit for higher demand. Plus you can always do domestic and hydronic heat from separate tankless units

    • @fgcbrooklyn
      @fgcbrooklyn ปีที่แล้ว +3

      Do you have a suggestion about the BRAND? I am looking into this but as usual the web is full of junk information and recommendations (secretly sponsored)

    • @Cody-ye3ye
      @Cody-ye3ye 7 หลายเดือนก่อน

      @@fgcbrooklynnavien is garbage

  • @joeellestad8912
    @joeellestad8912 3 ปีที่แล้ว +1

    Looking to heat a 2000sq radiant house along with hot water for 2 bathrooms and 1 kitchen. What is a good combination unit? Live in northern MN and will also have a outside wood boiler for the winter. Is it a good idea to have the propane as a backup unit when the owb is in use?

    • @spencerwilton5831
      @spencerwilton5831 3 ปีที่แล้ว

      Joe Ellestad In the U.K. 2000 sq foot would be considered a generously proportioned family home. Two bathrooms is a stretch for most combis if they are used at the same time- it's possible, but showering performance might be disappointing when the incoming water temperature is low. Although combi boilers have been widely used here for decades, for larger family homes with higher hot water demand a mains pressure hot water cylinder is still preferred. We use one boiler and a three port valve to serve both the cylinder and central heating. It eliminates the need for a separate water heater, allows for a backup (electric element in the cylinder) and means your boiler is in use daily rather than sitting idle for months at a time during summer which helps prevent parts seizing etc. It's also possible to integrate a wood boiler into the system by clever plumbing so you can run on either system or even both at the same time. There are various methods of doing so including the use of buffer tanks or simple manifolds that serve as a central point for both boilers, the heating and hot water circuits and allow for any combination of heat production and consumption.

  • @thomaspease208
    @thomaspease208 5 ปีที่แล้ว

    could you use this in a commercial restaurant

  • @mosthated8190
    @mosthated8190 7 ปีที่แล้ว

    what's the average installation price for one of these in California

  • @user-zi6os4jv6w
    @user-zi6os4jv6w 5 ปีที่แล้ว

    No bbn primer?

  • @elliottdiedrich3068
    @elliottdiedrich3068 ปีที่แล้ว

    In the third year when the computer motherboard craters, how much will it cost to repair the machine to running condition?

  • @BaconJD420
    @BaconJD420 ปีที่แล้ว

    What is the brand Combi was that?

  • @xiaojie895
    @xiaojie895 6 ปีที่แล้ว

    why some contractors put a storage tank beside the wall mount boiler but the demo installation on this video did not do it?

  • @johnburns4017
    @johnburns4017 5 ปีที่แล้ว +4

    ATAG, Dutch, re-badged by Rinnai. Quality. But the control system is complex. A pity Intergas, Dutch again, do not sell in the USA.

    • @mysticpizza02
      @mysticpizza02 4 ปีที่แล้ว

      Would have liked to have installed an ATAG but it was very expensive settled for an Alpha combi hope it lasts my previous standard boiler hot/cold water tanks lasted 34 years was very inefficient towards the end it was an Ideal mexico.

  • @danpham3804
    @danpham3804 3 หลายเดือนก่อน

    Do we have electric unit? thanks

  • @Mike-uf7oc
    @Mike-uf7oc 6 หลายเดือนก่อน

    I have Navien ncb 190/080h goes off on thermostat but it keeps running no/off every few minutes

  • @josht8288
    @josht8288 5 ปีที่แล้ว +3

    Oh goody' so if one small thing in the combi failed you lose both hot water and your heating. I would have left the old setup in place but isolated from the sistem as an emergency backup.

    • @iandouglas4992
      @iandouglas4992 4 ปีที่แล้ว

      That would be extremely combersum on the heating side, those systems have to be bled.

  • @johncoen869
    @johncoen869 7 ปีที่แล้ว +2

    You can get combi`s with hot water storage.

    • @jeffreyjohn2037
      @jeffreyjohn2037 4 ปีที่แล้ว

      You can get a condensing boiler with a indirect water heater.

  • @greentea7539
    @greentea7539 20 วันที่ผ่านมา

    We just had one installed and i been so worried that it is close to a window. I see though 12" is enough. Things have changed!!

  • @mr.dahliaking.202
    @mr.dahliaking.202 7 ปีที่แล้ว +5

    I hate my combi boiler because of the annoying cold water intervals whenever I turn off the hot tap and turn it on again. I changed my setup. I still keep my combi boiler for heating the house and basement, but the how water part for the taps I converted into closed zone, and by saying that I mean that I bought tesy bilight combinated 150 liters electric water heater with a copper spiral inside, and I am using termosthat to call the pump into action and water is circulating and the boiler thinks it's heating hot water for the taps when infact it is heating the tank water heater via spiral inside. It's like heat exchanger and it works great, no more cold water intervals and plenty of hot water pressure. I suggest this convert to everyone who hate the hot water fluctuation when the tap is turned on/off rapidly.

    • @jeanpierre-louis3986
      @jeanpierre-louis3986 6 ปีที่แล้ว

      Hi , I am very interested by your experience could send me some pics or a video. I wanna modify mine too. Thanks! My email: Zeledu1@gmail.com

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 11 หลายเดือนก่อน

    Yeah, I got a know that boiler over and over again because they are not reliable but that’s with any combination wall boiler, very touchy and expensive to repair. One major repair out of warranty you might’ve just spent up all your savings towards that one repair.
    But overall, they do save space they are efficient. They are reliable and they’re the way of the future versus big cast-iron boilers. They do make better sense as they’re more on demand. Just expect to replace them a lot sooner than the large cast-iron Boilers.

  • @stevepailet8258
    @stevepailet8258 4 ปีที่แล้ว +4

    as small a combi as this is. There are times when the heat call is still smaller than the combi will produce. So this is a great reason to keep the old tank water heater as a ballast tank with enough warmed water to supply the radiant without short cycling the combi. This seems to happen most often with using radiant heating as opposed to the convectors which usually have a much larger btu heat call. Radiant floor (could be in the wall or ceiling) spread the heat load and will have cooler water flowing than the convectors

    • @spencerwilton5831
      @spencerwilton5831 3 ปีที่แล้ว +2

      Steve Pailet a decent combi will modulate down to 2-3kw, sometimes lower. Short cycling shouldn't be too much of an issue on a well planned system.

    • @garethw001
      @garethw001 2 ปีที่แล้ว +2

      By the same principal could you use a traditional, inexpensive electric water tank to 'pre-heat' the water supply for the combi boiler to reduce the amount of gas used? (and fossil fuel burned)

  • @wardope
    @wardope ปีที่แล้ว

    Just installed a 30Kw air-to-water heat pump that runs off my Solar panels and wind turbine. free heat and free electricity. all the electricity I produce that I can NOT use or Store on the battery pack is being sold with. it's perfect for a 523901 Square inch house! alto this is a fare more expensive purchase up front but the entire system will pay it self off in about 10 years.

  • @nyglg44
    @nyglg44 6 ปีที่แล้ว +1

    Do these types of units exist for oil? Or are they just available for Natural Gas?

    • @Jessedog11
      @Jessedog11 ปีที่แล้ว

      no only gas- oil exhaust would clog the heat exchangers.

  • @Jason-wc3fh
    @Jason-wc3fh 5 ปีที่แล้ว +2

    Hack job venting install. Should use the deb4 deburring tool on the pipe before fitting them together and gluing them. Without deburring the end of the pipe, the bevelled end from the cut will push the glue out of the fitting and make for a weak joint.

    • @frmerrin2
      @frmerrin2 5 ปีที่แล้ว

      Yeah right.

  • @jonminnella4157
    @jonminnella4157 3 ปีที่แล้ว +6

    Great technology however when it brakes its expensive old boiler uses lots of gas but hardly ever brakes

    • @captaingreenhat
      @captaingreenhat 3 ปีที่แล้ว

      Exactly. With a little extra effort she could have kept her old equipment and still had a hybrid and efficient modern system.

    • @chooch5728
      @chooch5728 3 ปีที่แล้ว +3

      Everything is expensive to fix. old or new

    • @jochimbenschneider1915
      @jochimbenschneider1915 ปีที่แล้ว +1

      Electric boiler is better

  • @thatguy4234
    @thatguy4234 4 ปีที่แล้ว

    Lawd I’d hate to troubleshoot that thing

  • @dorianlord6576
    @dorianlord6576 3 ปีที่แล้ว +6

    I would definitely want the outdoor venting pipes on the side of the house--they are a bit unsightly.

    • @beoutside
      @beoutside 2 ปีที่แล้ว

      There are much better low profile venting options.

    • @OMGWTFLOLSMH
      @OMGWTFLOLSMH ปีที่แล้ว +1

      Yeah, that was a cheapy install. There are much better solutions.

  • @Djm02152846
    @Djm02152846 4 ปีที่แล้ว

    Wondering what's the company's name that did the work? Can hear his name Barry Cohen?

  • @ozm8642
    @ozm8642 4 ปีที่แล้ว

    USE A PANCAKE TERMINATION! Looks so much better than seperate or concentric IMO

  • @davidalearmonth
    @davidalearmonth 8 ปีที่แล้ว +2

    Hi! Could you please tell me what Make and Model you used? I see Rinnai?
    I'm looking at installing one This Week in my house. (in Ontario, Canada). It is a big old house, probably close to 3000 sqft, so I am curious if current models can handle that? My guy is recommending Navien combo boiler. (not sure what size. I think 240)
    Thank you for your help!

    • @thomasmacgowan
      @thomasmacgowan 8 ปีที่แล้ว +1

      +David Learmonth IBC Boilers are made in Vancouver!

    • @davidalearmonth
      @davidalearmonth 8 ปีที่แล้ว

      +Thomas Macgowan Thanks! I installed mine back in February. Ended up going with Viessmann. Works fairly well.

    • @tombomombodombo
      @tombomombodombo 3 ปีที่แล้ว

      @@davidalearmonth how come you got it over the navien? My plumber is recommending the navien.

    • @davidalearmonth
      @davidalearmonth 3 ปีที่แล้ว

      @@tombomombodombo Viessmann is just a really good name, and I think our previous boiler from the 80s might have been from them.
      We've been quite happy with it. Although the one change I would make is I would have had the boiler heat a small tank for domestic hot water instead of doing it completely on demand with the combi unit. The on demand domestic hot water is very quick to start, but the problem is due to safety the system still runs for 30 seconds after you turn off the hot water at the tap, which means that if you or an appliance request hot water again in that time suddenly you are getting cold water.

  • @Gamerz.280
    @Gamerz.280 5 ปีที่แล้ว

    Let me ask you a question what if you still have the old time boiler combo with the hot water intake would new boilers still work with it and how do the new boilers work compared to the boiler combo with the water intake

  • @Spiek-ICT
    @Spiek-ICT 5 ปีที่แล้ว

    Funny, the heater is from dutch manufacturer Atag. We use this type of combi heater for year's.

  • @Carmeri1928
    @Carmeri1928 ปีที่แล้ว +1

    How much is the price

  • @davidzhang7212
    @davidzhang7212 4 ปีที่แล้ว

    Why not use PPR pipeline?

  • @WILSON.1
    @WILSON.1 7 ปีที่แล้ว

    Is that expansion tank okay to be horizontal like that?

    • @macpatel7810
      @macpatel7810 4 ปีที่แล้ว

      Perfectly fine.. water in one half and compressed air in the other..

  • @silk33105
    @silk33105 8 ปีที่แล้ว +2

    @thisoldhouse this looks like a wonderful system but you didn't talk about price. how does it cost??

    • @malachy1847
      @malachy1847 7 ปีที่แล้ว

      Greetimgs from Ireland....They are mainstream over here in Europe so in that regard once sales in North America ramp up, the price will tumble..[.have a unit running off bulk kerosene unit installed in a rental property for the last 10 years ours is a 'Boiler house ' model ..... and apart from annual service zero issues] grantengineering.ie/high-efficiency-heating_products/best-oil-boiler-brand/

    • @andreyyaromich8277
      @andreyyaromich8277 4 ปีที่แล้ว

      10g+ installed

    • @autonomy5649
      @autonomy5649 3 ปีที่แล้ว

      The units aren't very expensive, relatively speaking, but for some reason installing them the labor jumps 3x despite all the propress, premade manifolds, and combi valves that are out there these days. $10K is about what I've heard, for labor only.

  • @robertjackson4121
    @robertjackson4121 5 ปีที่แล้ว

    What is part failure rate of each component of each unit with or without a service contract.

    • @MMKLYH
      @MMKLYH 5 ปีที่แล้ว

      Not that common, depending on the type of boiler but most of the parts you get within a few days, combi boilers are one of the best inventions ever honestly would highly recommend getting one if you don’t have too many radiators

  • @BetoTheButcher
    @BetoTheButcher 5 ปีที่แล้ว +5

    5:51: Nice to see Kurt Angle staying busy.

  • @r.t.7925
    @r.t.7925 6 ปีที่แล้ว +2

    Very nice! But will it be Ok in - 40? I've seen the exhaust frozen on condensing units, then pressure switch shuts it down .

    • @jadakkawi8152
      @jadakkawi8152 4 ปีที่แล้ว +1

      Your supposed to have a slope on the exhaust which is stated in the code book of your region to have the water go back into the appliance, there is a condensate trap in the appliance then it goes to a drain

    • @OMGWTFLOLSMH
      @OMGWTFLOLSMH ปีที่แล้ว

      That can happen on any type of high efficiency unit. It happened last winter on my parent's new natural gas forced air furnace. It's all about the install, which was shabby, in their case.

  • @joshtargo6834
    @joshtargo6834 4 ปีที่แล้ว

    what's the black foam covered thing below the boiler?

    • @autonomy5649
      @autonomy5649 3 ปีที่แล้ว

      Think it's a hydraulic separator but not sure which brand

  • @GalaXy808
    @GalaXy808 8 ปีที่แล้ว +1

    I have a question sir.i wanna know if is this a water heaters or it is? boiler combi

    • @MMKLYH
      @MMKLYH 5 ปีที่แล้ว

      It’s a combi boiler, a combi does heating and hot water it just gets rid of the need for having a hot water cylinder

  • @dcavic6157
    @dcavic6157 6 ปีที่แล้ว +1

    Are these available for Oil fuel?

    • @Ryan_D1994
      @Ryan_D1994 6 ปีที่แล้ว

      dcavic6157 yes

  • @jeffwright5794
    @jeffwright5794 2 ปีที่แล้ว +35

    Seems like a great idea..until it breaks down. Parts take days to weeks. Which is fine if you have backup heat for the house. Inevitably the thing will fail when it’s the middle of the winter. When that happens it’s quicker to replace the whole unit than waiting for parts. Supply houses usually have entire boilers in stock. Not so much for parts. Also when using radiators or base board heat you still need to run the boiler temperature at 180deg. Which reduces the efficiency substantially. These work best for radiant in the floor heat where the water temperature is usually at 130 deg. There are multiple plastic parts, sensors and control boards Also yearly maintenance must be done to keep the heat exchanger from becoming plugged with minerals. I’ve worked on these for decades, you won’t find one in my house.

    • @Keegeth
      @Keegeth 2 ปีที่แล้ว

      Rinnai and Naviens are very easy to get parts for in RI. Lochinvar and nti are a different story.

    • @jeffwright5794
      @jeffwright5794 2 ปีที่แล้ว +3

      @@KeegethIt recently took a week to get a three way valve for a Navien up state NY in a unit that was less than a year old . Other similar type units I've worked on I've always needed to wait for parts. My comments stand.

    • @Keegeth
      @Keegeth 2 ปีที่แล้ว

      @@jeffwright5794 that sux. For a 3 way valve for an ncb unit that had a bad 3 way valve I called plumbers supply and they had one on hand.
      An ncb heat exchanger was leaking combustion gases in the cabinet causing cabinet temp to rise, causing oil to be extracted out if the plastic parts and the pcb board to go bad took 2 days.

    • @adriansmith7104
      @adriansmith7104 2 ปีที่แล้ว

      What about the Polaris isn't that brand supposed to outlive you and your next generation. Is not tankless but it works for both.

    • @jeffwright5794
      @jeffwright5794 2 ปีที่แล้ว

      @@adriansmith7104 never heard of one up here and don’t have a local supplier for parts either

  • @marshall5132
    @marshall5132 5 ปีที่แล้ว

    all these how to videos are in homes that are freakin ridiculous. So much space to work... where is this paradise?

  • @captaingreenhat
    @captaingreenhat 3 ปีที่แล้ว +2

    Kills me how quick this old house is to punch holes in exterior walls. 😱

    • @chipdayton1625
      @chipdayton1625 3 ปีที่แล้ว

      So you want them to vent the boiler into the basement?

    • @jaredsmith1871
      @jaredsmith1871 2 ปีที่แล้ว

      @@chipdayton1625 Why couldn't they run an intake and exhaust vent up the existing chimney? They make concentric pipe for this purpose. Then you don't penetrate the wall with unsightly and possibly obtrusive venting. The woman moved the units to the wall but now has an unused chimney.

    • @chipdayton1625
      @chipdayton1625 2 ปีที่แล้ว

      @@jaredsmith1871 That can be an option sometimes.

  • @jamesvelvet3612
    @jamesvelvet3612 2 ปีที่แล้ว +2

    Original 1962 American Standard boiler and Westinghouse burner. Boiler has a coil, no external tank. 60 years old and works fine. So simple a cave man can fix it ;-)

    • @simpleagain1
      @simpleagain1 ปีที่แล้ว

      Throughout history cavemen have always received an unfair knock

  • @dantebbe
    @dantebbe หลายเดือนก่อน

    How much does something like this cost? Efficiency is great, but it it's not going to pay itself off for 15 years, most of us can't take the plunge.

  • @bmkolb
    @bmkolb 5 ปีที่แล้ว +7

    I love cast iron boilers the Combi is very very expensive to repair and service.
    Blowers cost from 300 to 600 plus labor.
    Controls cost from 350 to 1,000
    Anyone one of those two parts go bad your savings is gone on efficiency.
    The boilers might last 15 to 20 years vs cast iron 30 to 50 years

    • @gfriedman99
      @gfriedman99 5 ปีที่แล้ว

      B K like everything else nowadays it’s disposable. If it breaks you throw away and buy new

    • @DW-bo3qw
      @DW-bo3qw 4 ปีที่แล้ว

      You would be lucky to get 15

    • @hughjazzole2037
      @hughjazzole2037 5 หลายเดือนก่อน

      what blower?? its baseboard

  • @Jallelab99141
    @Jallelab99141 4 ปีที่แล้ว +2

    How come you did not use a low profile termination kit on the side of the house for the vents? Something like Rheem Horizontal Vent Termination Kit, or the IPEX Plastic Side Wall Vent Kit, or Trane BayVent?

  • @hmdwn
    @hmdwn 4 ปีที่แล้ว

    Ahhhhhh, so the combi gas boiler/hot water heater may NOT be able to handle 2.5 bathrooms operating at the same time showering/tub filling) plus, a dishwasher and supply hot water to a full house of baseboard heat.

  • @allentoyokawa9068
    @allentoyokawa9068 ปีที่แล้ว +2

    Made in Japan!

  • @mihaelalobontiu2050
    @mihaelalobontiu2050 4 ปีที่แล้ว

    Where may I buy a Vaillant boiler in US? I am rehabbing my home in Washington, DC. What other brands would be available in my area?

    • @TheHVACkid
      @TheHVACkid 4 ปีที่แล้ว +1

      Mihaela Lobontiu I used a Bosch Greenstar combi boiler in my house, it’s worked great for the past three years!

    • @mihaelalobontiu2050
      @mihaelalobontiu2050 4 ปีที่แล้ว

      @@TheHVACkid Thank you for your advice. I will try to get more info about Bosch Greenstar combi boiler

  • @DavidWilliams-wj4sc
    @DavidWilliams-wj4sc 2 ปีที่แล้ว

    Limitation 3. It can't cool your house like a forced air furnace/AC combo. Time to add some mini splits. Should have touched on that I think.

  • @orucheruyathra1517
    @orucheruyathra1517 3 ปีที่แล้ว

    Where are you located at . I would like you to come to my house and look at it

  • @dandano2602
    @dandano2602 4 ปีที่แล้ว

    What happens when you lose power in the winter? No hot water and no heat?

    • @autonomy5649
      @autonomy5649 3 ปีที่แล้ว

      Get a generator and you've got both, assuming you have hydronic heat and not a hardwired forced air handler.

  • @jaymorin4466
    @jaymorin4466 5 ปีที่แล้ว +5

    Don’t get to comfortable holding that expansion tank as you install that boiler. Most vulnerable connection on that boiler!

    • @macpatel7810
      @macpatel7810 4 ปีที่แล้ว

      Lol. I was thinking the same...

  • @MrPoofydrop
    @MrPoofydrop 4 ปีที่แล้ว +1

    Ive never seen flue pipes placed in such close proximity to a window. The flue pipe exhaust fumes will go right back into the house. Especially that house since they have an air conditioner in the window. The air conditioner will pull the exhaust fumes into the house when its running. im shocked that was allowed. No primer on pvc either? what state are they in and do they have inspectors?

    • @rainmaker3700
      @rainmaker3700 4 ปีที่แล้ว +1

      @@brennatrix I believe code is 36" from any opening.

    • @rainmaker3700
      @rainmaker3700 4 ปีที่แล้ว

      @@brennatrix Navien and Rinnai require 12" between the flue and the intake. But UBC requires 36" betweeen any opening and the flue pipe. Atleast that is what is enforced in my area of Northern Cali. I install 10-15 Navien boilers/water heaters a year.

  • @MemoGrafix
    @MemoGrafix 8 ปีที่แล้ว +1

    I can't do both heat and hot water at the same time, not good for Me.

  • @MrFy2013
    @MrFy2013 6 ปีที่แล้ว +8

    I love how many commenters here know better than Trethewy. Or think they do. #Dunning-Kruger

    • @kyleholland527
      @kyleholland527 5 ปีที่แล้ว +3

      Dunning Kruger IS the internet. And the White House.

  • @lucasvargas4580
    @lucasvargas4580 4 ปีที่แล้ว +2

    hello i´m from south of brasil, and we used this wather heater a lot of time, we never used a boiler, we used a gás passager. He just work wen you open the shower, when you closed he stop whith a gás.... This way we can saver money!

  • @san379
    @san379 8 ปีที่แล้ว +1

    better than a house fullllllll of ductwork but no A/C

  • @BlackRockian
    @BlackRockian 6 ปีที่แล้ว

    Should have installed an IBC.

  • @demil3618
    @demil3618 6 ปีที่แล้ว +1

    Amazed they still don’t work in metric...
    But why not install a condenser builder that recycles more of the exhaust heat with a pipe-in-pipe flue?

  • @MrPromerican
    @MrPromerican 4 ปีที่แล้ว +2

    I see hydraulic, air and dirt seprator, but where is the expansion tank? I guess rennai doesn't require it? But hydronic principle does...

    • @jamesfisher5391
      @jamesfisher5391 4 ปีที่แล้ว +2

      it's the red thing inside the boiler. You could add another depending on the water content of the heating system. 3:36 you can see him trying to break it off while hanging the boiler. lol

  • @centrumsolutions4744
    @centrumsolutions4744 3 ปีที่แล้ว

    Metal hole saw to cut the exterior hardi board??

    • @chipdayton1625
      @chipdayton1625 3 ปีที่แล้ว

      That's regular cedar shingle, not Hardi board.

  • @abccba7301
    @abccba7301 4 ปีที่แล้ว

    9:08 I take really long showers LOL

  • @zackdreamcast
    @zackdreamcast 4 ปีที่แล้ว

    What’s the difference between this and just running a tankless water heater?

    • @davidwooten3430
      @davidwooten3430 4 ปีที่แล้ว +1

      zackdreamcast This is just a guess but a tankless only heats water for use at a appliance. This does that and heats water in a loop for the heater upstairs without running up your water bill. Otherwise you would need to put in 2 separate tankless systems.