HYDRAULIC PRESS VS STEEL AND FIBERGLASS REINFORCEMENT, CONCRETE

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ก.ย. 2024
  • We will test the strength of iron-reinforced concrete and fiberglass-reinforced concrete with a hydraulic press

ความคิดเห็น • 149

  • @BZAKether
    @BZAKether ปีที่แล้ว +49

    I bet a lot of work went into this video, more than usual. Thank you.

  • @CaptainHelias
    @CaptainHelias 10 หลายเดือนก่อน +101

    Civil engineer here, this test is wrong because there are no stirrups . The concrete fails from sheer stress before the rebar starts to have effect. This is not how we do this test.

    • @ChristianWagner888
      @ChristianWagner888 10 หลายเดือนก่อน +3

      Good point! Are fiberglass stirrups available?

    • @werdebauingenieur5825
      @werdebauingenieur5825 10 หลายเดือนก่อน +4

      ​@@ChristianWagner888In Germany WE already had some projects with Fiber Glass stirrups, but Not many. So it isn't really mainstream Up to now.

    • @docfarl
      @docfarl 5 หลายเดือนก่อน +2

      ​​@@ChristianWagner888 He could have used steel stirrups in the both the fibre glass and steel-reinforced samples, to test the difference in bending strength due to the material used for reinforcement.

    • @kushdeala6623
      @kushdeala6623 5 หลายเดือนก่อน +3

      Do you know of a better demo / explanation of the pros and cons of rebar?

    • @josephfarrar2983
      @josephfarrar2983 4 หลายเดือนก่อน +1

      Wouldn’t this test be a good indicator for use in driveways?

  • @familyplan979
    @familyplan979 ปีที่แล้ว +63

    The big benefit of fiber rebar is that it does not rust. Modern structures of concrete fail often because of the metal reinforcement oxidation. The rebar rusts and changes shape and size, the concrete often is defeated from the inside. Structures could possibly last centuries instead of decades because of a small change in materials.

    • @juanmatus5708
      @juanmatus5708 ปีที่แล้ว +10

      BS. Fiber rebars decompose in concrete due to alkaline

    • @mahyadnaadlaw3112
      @mahyadnaadlaw3112 11 หลายเดือนก่อน

      @@juanmatus5708 alkaline didnt decompose my gfrp.

    • @InspiredScience
      @InspiredScience 11 หลายเดือนก่อน +10

      @@juanmatus5708 - That's not accurate. Most FRP rebar has a coating to resist high-pH (anyone spec'ing FRP would assure this) and the lifetime of FRP rebar with pH-degradation would be similar to steel in a best-case environment, while obviously much more resilient in a corrosive environment.

    • @williamnunez9609
      @williamnunez9609 7 หลายเดือนก่อน +2

      @@InspiredScience You basically just let me know to not cut the FRP rebar, being that most people do because of size of project.

    • @InspiredScience
      @InspiredScience 7 หลายเดือนก่อน +2

      @@williamnunez9609 - Thank you. As with all reinforcing bar, ideally you want to have it shipped and use it in the maximum possible length for economy.
      Every time you have a cut/seam, it requires substantial overlap, plus the small bit of labor which adds-up as well.
      When it was suggested that FRP corrodes, that is not an issue to be concerned with, regarding cutting.
      The simplest way to think about it is to check what environment you're using the rebar in, then confirm the resins used and whether there is any issue.
      I don't know of any reputable FRP rebar resellers who are selling FRP rebar where there would be an issue; however, it cannot hurt to double-check.
      BTW - I spec a lot of coastal work in Florida; you wouldn't happen to work there, would you?

  • @stevecollins5308
    @stevecollins5308 หลายเดือนก่อน +3

    It seems like the fiberglass reinforced concrete failed earlier than the steel reinforced concrete at least partly because the fiberglass bars didn't bond as well with the concrete. Although the fiberglass bar alone was brittle and not ductile, those characteristics didn't seem as big a factor in it's failure mode. It seemed rather that the concrete spalled away much worse with the fiberglass than with the steel. Thank you for the informative video.

  • @ihdieselman
    @ihdieselman ปีที่แล้ว +58

    I wonder what the strength difference would be if you subject them to salt water spray for 5 minutes every hour for a year.

    • @enekojobajuria3397
      @enekojobajuria3397 ปีที่แล้ว +5

      Ahí sin duda las varillas de fibra de vidrio arrasan frente a la varilla de acero. Obviously the GFRP doesn't suffer corrosion, so the result could be even better for the GFRP concrete against de steel reinforced one.

    • @devkumardevaghanghash5077
      @devkumardevaghanghash5077 4 หลายเดือนก่อน

      ​@@enekojobajuria3397😅😅😊😊😅

  • @jamesortiz5388
    @jamesortiz5388 ปีที่แล้ว +20

    Large stones in a small space gives it
    less strength.

  • @craigbooth5414
    @craigbooth5414 ปีที่แล้ว +15

    I've never seen fiberglass reinforcement like this. Usually fiberglass reinforcement in concrete is in the form of chopped strands mixed throughout the concrete. I'd be curious as to their impact on the strength

    • @bogey19018
      @bogey19018 ปีที่แล้ว +2

      Home depot sells it now. I'd stick with steel.

    • @lem8304
      @lem8304 ปีที่แล้ว

      Can concrete with fiber glass potentially be hazardous for your health? When inhaling the dust?

    • @craigbooth5414
      @craigbooth5414 ปีที่แล้ว

      @@lem8304 Cement by itself is already harmful to your health when inhaling the dust. Adding the fiberglass won't really make it much worse.

    • @enekojobajuria3397
      @enekojobajuria3397 ปีที่แล้ว +3

      The concrete by itself can produce silicosis in the long term, adding chopped glass fiber is thge same, but in a gfrp the glass fiber goes incapsulated by a polymer. El propio hormigón contiene arena de sílice y el polvo que produce puede generar silicosis a largo plazo, añadir fibra de vidrio cortada no lo empeora mucho más, ahora bien, con las varillas corrugadas de fibra de vidrio no hay ese problema ya que van encapsuladas en un polímero, eso sí, al cortarlas desprenden polvo tóxico por inhalación.

    • @enekojobajuria3397
      @enekojobajuria3397 ปีที่แล้ว +1

      The chopped AR fiber glass in concrete is mainly used for flooring. El hormigón reforzado con fibra de vidrio cortada del tipo Álcali Resistente se usa mayoritariamente para soleras, no para forjados, vigas o pilares, los cuales suelen ir armados.

  • @hartur1212
    @hartur1212 7 หลายเดือนก่อน +3

    Could you try placing the reinforcing stirrups in the steel and the polymer? Should it result in greater resistance in both cases?
    I will be attentive to your comments, thanks

  • @brianblithe2271
    @brianblithe2271 9 หลายเดือนก่อน +10

    can you do fibreglass mesh strands and steel rebar then steel strands and steel rebar ?

  • @aaronsmith8073
    @aaronsmith8073 ปีที่แล้ว +5

    Like a moth to a flame...here I am watching another one of these videos 😂

  • @novicewatcher5109
    @novicewatcher5109 5 หลายเดือนก่อน +4

    More fiber glass is needed because the rebar is heavy. Maybe 1:2 ratio

  • @vivekkumarpandey5100
    @vivekkumarpandey5100 2 หลายเดือนก่อน +2

    Steel rods with a cover of fiberglass straw🤔 to keep rustfree from at least outer surface.... basically a fiberglass coated steel rods...

  • @jovandievski9116
    @jovandievski9116 7 หลายเดือนก่อน +2

    I see most of the coments comparing steel, concrete and fiber implementations in construction mostly. Yea theres oxidation and etc. But fiber is more efficient in modern techn regarding windmilss and such. Lighter, easier to shape and mold. It takes good procces of mixing,wraping,heating,drawing out air from the structure and such but it makes it much more efficient and less expensive for making and repairing. Its modern day eras material that industries use to pervent old ways and long ways of making em. Fiber is the best for coating for everyindustry besides constructing buildings acording to me despite they use it for some specific type buildings which are rare and not designated to be for living of people.

    • @tharuneswar4001
      @tharuneswar4001 28 วันที่ผ่านมา

      Can build a new home for frp

  • @sergiojunior4458
    @sergiojunior4458 ปีที่แล้ว +2

    Sempre tive curiosidade de saber se uma coluna de concreto era realmente resistente

  • @niveknospmoht8743
    @niveknospmoht8743 7 หลายเดือนก่อน +2

    Looked like way too much rock in the mix. How about a video with a proper mix with Helix steel for additional reinforcement

  • @Htoon2008
    @Htoon2008 ปีที่แล้ว +3

    Teste muito bom e satisfatório.

  • @TheUjjwalarora
    @TheUjjwalarora 4 หลายเดือนก่อน +1

    How about steel rebar and added glass fiber for reinforcement?

  • @docfarl
    @docfarl 5 หลายเดือนก่อน +2

    You dont get the full benefit of fibre glass reinforcement when you bunch it up like that in a rod. You should finely chop up and mix the individual strands with the concrete, to provide bonding strength between the concrete and fibre glass.

    • @probinson7967
      @probinson7967 2 หลายเดือนก่อน

      I live in the Dominican Republic. Retired American. No experience in construction. I live about 2 mi from the Caribbean. Presumably there is some salt content in the air here. I see a lot of failed concrete around with rusted swelled rebar literally blowing the concrete apart.
      I am fascinated with the idea of replacing iron rebar with fiber reinforcing in some applications.
      The best roofs around are flat poured concrete with rebar. This can also be the flloor of a second story, etc. A lot of labor goes into building the plywood forms and supporting the forms with beams and a forest of posts underneath.
      I have a yearning to build a very different kind of roof. I imagine a roof poured in strips in the form of a downward-arching catenary shape. I understand that a catenary puts the shape under pure tension. There would need to be some kind of sling (a sort of hammock) to support the cement while setting.
      When set, the catenary shape would be flipped over (arch upwards) which should put the material under pure compression. I'm imagining eliminating the iron and just using fiber. Multiple abutting strips would form the roof. No good for second floor, but a pleasant arched ceiling indoors.
      Does anything make sense here? Does anyone want to talk about this? Peter. prx555 at gmail

  • @zozobp
    @zozobp 13 วันที่ผ่านมา

    it would be good to see a micro fiber concrete too

  • @tanzeemfatima3034
    @tanzeemfatima3034 หลายเดือนก่อน +1

    #Accurate Result 💯💯💯
    We Cant Believe On Plastic , If We Build House

  • @donalfinn4205
    @donalfinn4205 3 หลายเดือนก่อน +2

    This is fine for a home ‘test’/ fun, but bears no absolute resemblance to a real structural test.

  • @enekojobajuria3397
    @enekojobajuria3397 ปีที่แล้ว +1

    Very good behavior of the GFRP rebar reinforced concrete, even better of what I was expecting for...
    Muy buen comportamiento del hormigón reforzado con varillas de PRFV, mejor de lo que me esperaba.

  • @dhananjayshendageshendage8838
    @dhananjayshendageshendage8838 24 วันที่ผ่านมา

    मस्त भाई दोनोका फरक दिखा दिया ❤❤

  • @barnowl6807
    @barnowl6807 ปีที่แล้ว +3

    If your primary requirement is strength for a short time (say

    • @Promilus1984
      @Promilus1984 ปีที่แล้ว +5

      Yeah... and here I'm sitting in a house built in 1956 using A0 steel rebars - unless they had insufficient concrete cover all those bars suffered very little corrosion and surface only. It's very different in things like bridges or foundations - where there's plenty of water during the lifetime. And yet there are bridges made by nazis (up to 1945) with little to no degradation of rebars. And same goes to bunkers etc. As with everything - it depends. It depends how fast pH of concrete will drop below ~10.8, it depends how often water would penetrate concrete, it depends how much chlorium will sink into a concrete etc. etc.

    • @mahyadnaadlaw3112
      @mahyadnaadlaw3112 ปีที่แล้ว

      Depends on the quality of rebar

  • @ManishKumar-ym3rx
    @ManishKumar-ym3rx 29 วันที่ผ่านมา

    Bhai ase or bhi test kro good

  • @kenmorrisproducer
    @kenmorrisproducer 4 หลายเดือนก่อน +1

    Noting that the fiberglass did not shatter or splinter when encased in concrete.

  • @Cat_of_America
    @Cat_of_America ปีที่แล้ว +2

    Good

  • @qs3850
    @qs3850 ปีที่แล้ว +5

    Wayy to much stone in that mix

  • @AlwaysHopeful87
    @AlwaysHopeful87 3 หลายเดือนก่อน

    Try putting both to a temperature test for expansion, then humidity, then both temperature and humidity, then both with stress. Leave each in a salt bath for a month too.

  • @-TrafficCone-
    @-TrafficCone- ปีที่แล้ว +17

    ⬇️The count of people who finds enjoying this type of videos⬇️

  • @ShreeKateel-wd9hn
    @ShreeKateel-wd9hn หลายเดือนก่อน

    For simply supported beam, why you are using top bars

  • @mrbackyardmechanic3956
    @mrbackyardmechanic3956 ปีที่แล้ว

    Great comparison. But, like others have said, maybe less or smaller crushed gravel. I've been using pink bar recently, 7 ft. basement cinder block wall repairs. Wear gloves, they do have splinters, ouch. Might use rebar again, $1 more for fiberglass 10 ft. but for 7 - 8 ft. walls, rebar might be overkill.

    • @mhxxd4
      @mhxxd4 9 หลายเดือนก่อน

      How does pinkbar compare to steel? Pouring a slab in 2 days

  • @robnowe5464
    @robnowe5464 ปีที่แล้ว +2

    Interesting that the FRP didn't shear, but the concrete-FRP bond failed.

  • @thekingofmeerut6716
    @thekingofmeerut6716 17 วันที่ผ่านมา

    Once you put both the iron rods and the fiber in the fire, make a video and show it.

  • @AbhirupBhowal
    @AbhirupBhowal 5 หลายเดือนก่อน +2

    any body who understands engineering and design can make a fiberglass pillar stronger than steel.

  • @TheGentlemanTalk
    @TheGentlemanTalk 2 หลายเดือนก่อน

    one fiber breacks tis waste but steel can be use again right

  • @TundeEszlari
    @TundeEszlari ปีที่แล้ว

    The video was sensational.

  • @ccxcxv
    @ccxcxv ปีที่แล้ว +4

    It's not an accurate test because the concrete with steel reinforcement failed in concrete shear before the steel failed.

    • @gutersteinker
      @gutersteinker ปีที่แล้ว

      Like why the heck would you perform a test that is no representative of real life construction methods

  • @GuzzarAwan
    @GuzzarAwan 2 หลายเดือนก่อน

    carbon Fiber Rebars and its Slabs made with Concrete shd also be tested to tell weather it can compete with steel or not.

  • @BrainBulbFacts
    @BrainBulbFacts ปีที่แล้ว +3

    Can I use your video clips for my shorts video 🇮🇳❤️

  • @joosepkunder
    @joosepkunder ปีที่แล้ว

    Thank you, it was well made test and very interesting! :)

  • @shreeshdixit3391
    @shreeshdixit3391 2 หลายเดือนก่อน

    Stainless steel or zinc coated galvanized steel is better option, in steel plants rustproof chemicals should add while melting

  • @Elvis-x8o
    @Elvis-x8o ปีที่แล้ว

    Can u make another video using both materials in one Concrete and test it. I bit the results will surprise u 👍🏻

  • @tdobson888
    @tdobson888 3 หลายเดือนก่อน

    Steel is used in the main support members and fiber can only be used for non critical structure like flooring the reason is steel is stronger and also more flexible than fiberglass.

  • @nerobasta3242
    @nerobasta3242 ปีที่แล้ว +2

    👍

  • @TheFneal
    @TheFneal หลายเดือนก่อน

    Let´s calculate how much should it resist then crush it and than compare it to the expectation! It should have been much more fun.

  • @TheGentlemanTalk
    @TheGentlemanTalk 2 หลายเดือนก่อน

    when earth quick comes , steel service due to flaxibilty but fiber down in in single shot . so care full dont go with advartised

  • @asif55walikar
    @asif55walikar 8 หลายเดือนก่อน

    Can anyone tell me the load taken by steel concrete and frp concrete to collapse?

  • @RamchouhanChouhan-sg2kt
    @RamchouhanChouhan-sg2kt 24 วันที่ผ่านมา

    उज्जैन में मिल जाएगा क्या रतलाम में मिल जाएगाक्या

  • @haikelarcia199
    @haikelarcia199 9 หลายเดือนก่อน +1

    Stirrups?

  • @neil111ci
    @neil111ci หลายเดือนก่อน

    stirrups please in both cases.

  • @ganeshrao4454
    @ganeshrao4454 26 วันที่ผ่านมา +1

    🎉🎉🎉🎉❤

  • @GauravSingh-zz9rf
    @GauravSingh-zz9rf ปีที่แล้ว +1

    do you know how to conduct tests for real ? The strength for steel here is ultimate as shown by you but it becomes useless at soon as it reaches the yield strength. you know plastic and elastic deformation ? the yield strength of GFRP is much higher than steel but you are considering the failure strength here.

  • @goodknowlage2952
    @goodknowlage2952 2 หลายเดือนก่อน

    Agar jalaya jaaye to fiber turant jal sakta hai bhai

  • @HoussamCommercialORAN
    @HoussamCommercialORAN 10 หลายเดือนก่อน

    I DON'T GET IT, GFRP SHOULD RESICTE MORE THAN STEEL,? CAN SOMENO EXPLAIN IT ?

    • @jurirao6853
      @jurirao6853 3 หลายเดือนก่อน

      My guess is that steel rebar is better anchored in the concrete than the fiberglass, since no rebar was broken. Ofcourse, since no stirrups were used, the ultimate limit state was achieved by shear force, not the moment, and therefore rebar didnt reach the maximum tensile force. Still, a good test for youtube :)

  • @perfecttechnical5123
    @perfecttechnical5123 ปีที่แล้ว

    Very good

  • @kiwibonsai2355
    @kiwibonsai2355 ปีที่แล้ว +3

    Call me old fashioned but I miss the mentality of building things to last generations.
    Iron reinforcement in concrete seems to me like a short term fix, like lead water pipes or asbestos ceilings, just not the right material to be using for the job.

  • @andrewjackson244
    @andrewjackson244 6 หลายเดือนก่อน +1

    Why not just use an actual concrete mix instead of making your own with those giant rocks?

  • @AlexSantos-db6fm
    @AlexSantos-db6fm 5 หลายเดือนก่อน

    Concreto com fibra já tinha rachado muito muito antes dele considerar como a quebra.

  • @시오리이뻐욧
    @시오리이뻐욧 ปีที่แล้ว

    개인적으로 돌을 강가에 있는 타원형 돌을 사용했다면 강도다 더 올라갈것으로 생각됩니다. 모래또한 마찰을 주어 모난 부분을 제거 해준다면 강도가 더 올라갈것 같습니다.

    • @mythocrat
      @mythocrat 8 หลายเดือนก่อน

      Interesting point

    • @시오리이뻐욧
      @시오리이뻐욧 8 หลายเดือนก่อน

      @@mythocrat 근데 재료값이 올라감 ㅋㅋ

  • @mattrich8812
    @mattrich8812 8 หลายเดือนก่อน

    Can you try this with MST bar?

  • @scottweinberg3268
    @scottweinberg3268 ปีที่แล้ว

    You need bigger rock, smaller mixing container, smaller point load (or just the opposite for testing purposes) Just saying...

  • @lorriecarrel9962
    @lorriecarrel9962 ปีที่แล้ว +3

    If you would have used the same weight in glass fiber bars as what the steel weighs and did the test that way you would get better result,pound for pound type thing

    • @GauravSingh-zz9rf
      @GauravSingh-zz9rf ปีที่แล้ว +1

      exactly, GFRP has low midulus of elasticity hence it requires more surface area

  • @manthenashivasai7033
    @manthenashivasai7033 8 หลายเดือนก่อน

    Where we get this?

  • @Doraemon-o8f
    @Doraemon-o8f 3 หลายเดือนก่อน

    Nice video but annoying loud music

  • @victorkucastro8027
    @victorkucastro8027 2 หลายเดือนก่อน

    Yea good

  • @tealkerberus748
    @tealkerberus748 22 วันที่ผ่านมา

    Nobody mixes concrete in a bucket. If you can't afford a barrel mixer, at least mix it in a wheelbarrow.

  • @mehmetcantutar9306
    @mehmetcantutar9306 ปีที่แล้ว

    try with carbonfiber rebar bro

  • @TheGentlemanTalk
    @TheGentlemanTalk 2 หลายเดือนก่อน

    still is steel is steel i will go with steel becuase one fiber brack it cant pe joint but steel can be joint

  • @userFundamentalRights
    @userFundamentalRights 14 วันที่ผ่านมา

    Whatever it is,steel is much more safer and worth reliable.

  • @jimmatrix7244
    @jimmatrix7244 2 หลายเดือนก่อน

    concrete + fibreglass started hairline crack at more than 900+

  • @Greenville-vm3yu
    @Greenville-vm3yu ปีที่แล้ว

    If you press them like a beam, the bars must be the bottom of concrete

  • @zeft81
    @zeft81 ปีที่แล้ว

    what was the size of the concrete

    • @mhxxd4
      @mhxxd4 9 หลายเดือนก่อน

      About 350

  • @SachidanandSharma-u1x
    @SachidanandSharma-u1x 15 วันที่ผ่านมา

    Dono me ring nahi Hai to majbooti kaishe ayega backwash video

  • @Robin-hy6sz
    @Robin-hy6sz ปีที่แล้ว

    Am i the only one who's only now noticing that he's wearing a jacket from the German military

  • @LinKueiDragon
    @LinKueiDragon ปีที่แล้ว +1

    Just proves older cars are better than new ones, yet again.

    • @micci123456789
      @micci123456789 ปีที่แล้ว +1

      Are you smoking man? Did you seriously say that and mean it? You're telling me something that is less than half the weight of the steel is only marginally weaker because the weight wasn't taken into account in the amount of material used. If he used the number of bars of fiber glass that would weigh the same as the steel it wouldn't budge.

  • @shreeshdixit3391
    @shreeshdixit3391 2 หลายเดือนก่อน

    After bending glass lost every thing needed it is fragile useless, Hard plastic pipes containing greased steel bars are permanent solution

  • @siargao_life
    @siargao_life 8 หลายเดือนก่อน

    Качество композитной арматуры зависит от применяемых материаллов и квалификации производителя.

  • @AlexanderA80
    @AlexanderA80 ปีที่แล้ว

    Нужно было добавить стекловолокно в виде коротких волокон в раствор, чтобы волокна распределились по всему объёму. Арматуру тоже нужно оставить.

  • @AhmedIbrahim-yt5xw
    @AhmedIbrahim-yt5xw 8 หลายเดือนก่อน

    This the truth😂😂😂

  • @life-vida1439
    @life-vida1439 ปีที่แล้ว +2

    Bad concrete mix.

    • @MattRio
      @MattRio ปีที่แล้ว

      I agree with you 100%. That looked like they used 3 inch crushed stone. Should have used no bigger than 3/4 inch. 33% sand, 33% 3/4 inch crushed stone and either a 60-80 lbs bag of cement. And properly mixed, felt like it wasn't even mixed right either.

  • @SquidwradThomas
    @SquidwradThomas ปีที่แล้ว +2

    China learning how to reinforce their concrete be like. Plastic is good enough 👍

    • @kiwibonsai2355
      @kiwibonsai2355 ปีที่แล้ว +1

      Yet America waits on Chinese steel.
      I remember when America had a backbone of industrial might, sadly its cheaper to pay someone overseas rather than paying a fallow countryman a living wage.
      Its not about being fair it's about the freedom to do business Reagan reckoned, how's that going?
      Dont hate educate.

  • @hanamantankushi4466
    @hanamantankushi4466 29 วันที่ผ่านมา

    नंबर

  • @coldcrankinamps
    @coldcrankinamps ปีที่แล้ว +1

    If concrete was truly this weak then it wouldn't be the second most used substance in the world. These videos are incredibly misleading and you'd be hard pressed to find a better substitute for concrete in our world.

    • @gb4939
      @gb4939 6 หลายเดือนก่อน

      I really hope you're right about that because thousands of concrete buildings have people who work or live in it. Also concrete houses are cheaper in my country and I am interested to buy one but I read some very alarming things about concrete that I hesitate a lot.

  • @PaikraGroups
    @PaikraGroups หลายเดือนก่อน

    Steel is best don't trust on fiber glass

  • @mcchupka9718
    @mcchupka9718 2 หลายเดือนก่อน +1

    WAY too much aggregate (stone) in that mix for a fair test of anything strength related, even a comparison test.

  • @shantanuzadke
    @shantanuzadke ปีที่แล้ว +1

    कोण कोण मानता है की अपनी माता पिता की चरणो मे स्वर्ग है ❤️❤️

  • @makromikro273
    @makromikro273 ปีที่แล้ว

    Unreliable test, fatal concrete... Actually, it's not concrete, but a cake.

  • @8eSix
    @8eSix ปีที่แล้ว +5

    I wonder if hair would be a beneficial additive. I believe this was done with plaster in the past. They also have coated rebar that resists corrosion. I'd like to try a combination of the hair and coated rebar for a test.

    • @mhxxd4
      @mhxxd4 10 หลายเดือนก่อน +1

      Coated rebar bad

    • @ChooseLife.YourLife
      @ChooseLife.YourLife 6 หลายเดือนก่อน +1

      Horse hair and lime in plaster or something like that

    • @andrewjackson244
      @andrewjackson244 6 หลายเดือนก่อน +2

      Pretty sure hair and other fiber is for resisting cracking when portland cement is not involved

  • @Soma-7662
    @Soma-7662 ปีที่แล้ว +2

    shouldn't the mixture be 50/50?!! that was more like 66/33 sand to cement

  • @luciusirving5926
    @luciusirving5926 3 หลายเดือนก่อน

    If concrete, like say papercrete, is made using hydraulic or mechanical pressing, then of course it will get used to being pressed again, even after curing.

  • @bsm2001yt
    @bsm2001yt 2 หลายเดือนก่อน

    The bars are not pretensioned? Contrete works best under compression. I'm not sure this is an accurate test of how concrete would actually be used.

  • @elhoward7440
    @elhoward7440 2 หลายเดือนก่อน

    But... isn't rebar for tension, not compression strength?

  • @perfecttechnical5123
    @perfecttechnical5123 ปีที่แล้ว

    Buitefull