VLT® Drives: No display when powered up

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • This video discusses information and common troubleshooting tips for a Danfoss VLT variable frequency drive in which there is no display on the LCP (Local Control Panel) when the drive is powered.
    For additional information please visit www.danfossdri...
    * If you need immediate assistance contact Danfoss Drives: Phone: +1 888-DANFOSS (1-888-326-3677)
    or
    E-mail:
    Customer Service: Drives.CS.NA@danfoss.com
    Technical Support: Drives.TS.NA@danfoss.com
    After Sales Service: Drives.TS.Service.NA@danfoss.com
    For additional AC Drive Technical Support, subscribe to the Danfoss Drives newsletter at bit.ly/NAMDDSNews.

ความคิดเห็น • 10

  • @masumrana6469
    @masumrana6469 3 ปีที่แล้ว +1

    It's definitely significant for us, thank to so many

    • @DanfossdrivesNA
      @DanfossdrivesNA  2 ปีที่แล้ว

      You're welcome, we are happy the video helped.

  • @dariuszkopec3758
    @dariuszkopec3758 2 ปีที่แล้ว +2

    in my case, the replacement of four 35V 220uF capacitors helped, previously I checked the voltage on the DC BUS and it was ok also the voltage of 24V DC between terminals 12 and 20 was fine

    • @DanfossdrivesNA
      @DanfossdrivesNA  2 ปีที่แล้ว

      For installation, start-up, programming and troubleshooting assistance please email: Drives.TS.NA@Danfoss.com
      or if you need immediate assistance contact Danfoss Drives 24/7 tech support at: +1 888 DANFOSS (326-3677)

  • @protectorh9167
    @protectorh9167 2 ปีที่แล้ว +1

    I have an old vlt 2800 which the display will come on after a long time when energized but today the display stayed out, what I did: put the power out and took the wire out on connector 18 and 20 and then I put the power on. Direct the display started up 🤗
    Lucky me.

    • @DanfossdrivesNA
      @DanfossdrivesNA  2 ปีที่แล้ว

      For installation, start-up, programming and troubleshooting assistance please email: Drives.TS.NA@Danfoss.com
      or if you need immediate assistance contact Danfoss Drives 24/7 tech support at: +1 888 DANFOSS (326-3677)

  • @sergeysuranov7138
    @sergeysuranov7138 2 ปีที่แล้ว

    Blank display, I think that problem is in firmware of LCP or interrupt data stream.

    • @DanfossdrivesNA
      @DanfossdrivesNA  2 ปีที่แล้ว

      For installation, start-up, programming and troubleshooting assistance please email: Drives.TS.NA@Danfoss.com
      or if you need immediate assistance contact Danfoss Drives 24/7 tech support at: +1 888 DANFOSS (326-3677)

  • @joewaterbury266
    @joewaterbury266 3 ปีที่แล้ว

    DC bus overvoltage

    • @DanfossdrivesNA
      @DanfossdrivesNA  3 ปีที่แล้ว

      For tech support information please visit www.danfoss.com/en-us/service-and-support/fix-and-troubleshooting/drives-support/