How To Test a VFD (variable frequency drive)

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ก.ย. 2024

ความคิดเห็น • 39

  • @pjofurey6239
    @pjofurey6239 ปีที่แล้ว +1

    Nice.simple.clear .suspect a grumpy VFD on my lovely old skool mill, this film gives me the enthusiasm to investigate .subbed.

  • @svsoleil3255
    @svsoleil3255 4 หลายเดือนก่อน +2

    "They explode a bit and let the smoke out.." LMAO...

  • @carlhutchison4118
    @carlhutchison4118 7 หลายเดือนก่อน +1

    Very good have 27kv pump motors and 12 wire soft start motors at work good testing thanks

  • @bryanvigil6554
    @bryanvigil6554 6 หลายเดือนก่อน +1

    Very useful I actually came across one today and I needed this video

    • @engineeringsupport247
      @engineeringsupport247  5 หลายเดือนก่อน

      This is why I make them, glad you found it useful

  • @jonerasmus9399
    @jonerasmus9399 ปีที่แล้ว +4

    Thank you for the video . The only thing I wish was you showing on the schematic which points your were testing between a little more clearer. Otherwise I quite enjoyed your vid . Thank you for your effort to teach us things the technicons failed to do

    • @engineeringsupport247
      @engineeringsupport247  ปีที่แล้ว +1

      Thanks for the feedback, I will try to do an update on the schematic

    • @jonerasmus9399
      @jonerasmus9399 ปีที่แล้ว +1

      @@engineeringsupport247 I'd very much like that . Thank you so much ...legend

  • @NONEYAZ
    @NONEYAZ ปีที่แล้ว +4

    Good Teaching!
    Just A Tip For The Young Bucks & Doe's Out There! When Your In Industrial Manufacturing As A Technician Responsible For Troubleshooting, Fixing And Preventive Maintenance Of Equipment.
    Your Ultimately Responsible For Optimum Up Time, Output And Quality Of Equipment And The Products Being Produced & Processed! Therefore, There's Not Much Time In Production For Testing & Troubleshooting!
    Remove Smoking, Burnt Defective Modules, Assemblies, Devices, Etc! Swapping Them With New Ones Whenever Possible! Once Verified The Equipment Was Up And Running In Optimum Condition By Troubleshooting With New Modules Along With All Other Equipment Of Responsibility Being Up And Running! Take The Suspect Modules, Etc, In Engineering/Technicians Lab To Repair By Opening And Removing, Replacing Said Burnt Defective Components! Then, Test As Needed Or You Could Send Them Out For Repair Or Replacement To Vendor(s) Depending On Free Time Of Up/Down Time Of High Volume Production Equipment! Most Of The Time As A Technician You Have To Learn To Put Out The Fire(s) And Read Every Vendor(s) Machine And Equipment User/Troubleshooting And Repair Manual You Can! The Internet Wont Always Be Here Or Up & Available Due To Censorship Or Who Knows What!?!
    Thus, There's Always Time To Learn To Wash, Polish And Wax The Fire Truck After It's Repaired, Maintained & In Working Order If You Spend Time Wisely Reading The User & Repair Manuals! 😎

  • @austrianpainterinhiding88
    @austrianpainterinhiding88 ปีที่แล้ว +2

    Good video with a straight forward and simple explanation of theory. I work in hvac and run into these quite a lot. Just subbed.

  • @anirutkhaopluem6485
    @anirutkhaopluem6485 2 ปีที่แล้ว +2

    Good explanation, THANK YOU!

  • @frobertopereira
    @frobertopereira ปีที่แล้ว +1

    Very nice. Helped a lot. Thank you.
    In my VFD 9600D-1T-00220M case, the brake resistor is internal. It has two output connectors to attach an external resistor but was internally not wired, so I had to open it to access P+ and P-.

    • @engineeringsupport247
      @engineeringsupport247  ปีที่แล้ว +1

      Sounds like a nightmare, but good work for figuring it out 👍

  • @AshrafIbrahim-r2c
    @AshrafIbrahim-r2c หลายเดือนก่อน

    Thanks, dear.

  • @donnacorbett5165
    @donnacorbett5165 2 ปีที่แล้ว +1

    excellent video learned a lot, nicely explained

  • @jaykesapalaran5434
    @jaykesapalaran5434 ปีที่แล้ว +1

    Wow great tutorial.. please make more educational video.. you deserve to be subscribe.

  • @bikefarmtaiwan1800
    @bikefarmtaiwan1800 ปีที่แล้ว +1

    Nice video - maybe you will be interested to know that the wiring in the bridge rectifier is what "magically" turns AC into the full wave rectified DC . The capacitor takes this wavy DC and then smooths that into the power that is used on the DC bus . The bridge rectifier wiring does some crafty re-routing to achieve this which had me confused for a while .... how does negative become positive ?? Regardless of the side that the AC wave is on compared to the zero volts line it is all voltage potential so half of the bridge flips the lower ( negative part of the AC wave ) up to the top to give you full rectification - no gaps ! Hope that helps

    • @engineeringsupport247
      @engineeringsupport247  ปีที่แล้ว

      Thanks, that takes me back to college. It also stumped me for ages how the rectifier works.

  • @igieborjolly1106
    @igieborjolly1106 ปีที่แล้ว

    Nice one, I have an issue with a seimen 120 ac drive. When you put power on the 3phase incoming I don't get a DC voltage on the capacitor side.

  • @electrical8308
    @electrical8308 2 ปีที่แล้ว +2

    Panel got 'cleaned' 😂. I know exactly what you mean! 'hygiened' by any chance 😂

    • @engineeringsupport247
      @engineeringsupport247  2 ปีที่แล้ว +1

      Yeah lol “what would happen if I put a high pressure hose on that”

  • @ChandrashekarCN
    @ChandrashekarCN 4 หลายเดือนก่อน +1

    💖💖💖💖

  • @tupachillin
    @tupachillin 11 หลายเดือนก่อน +1

    So when your checking reverse bias, you want an infinite or OL reading?

    • @engineeringsupport247
      @engineeringsupport247  10 หลายเดือนก่อน +1

      I believe this depends on the meter, my Fluke multi meter will show OL and my Megger Low ohm meter will show infinity.

  • @blackbearbowie8162
    @blackbearbowie8162 6 หลายเดือนก่อน +2

    can you show how find out the kw of a vfd that has no data plate ?

    • @engineeringsupport247
      @engineeringsupport247  5 หลายเดือนก่อน

      I don’t know how to do that sorry

    • @kevinmithnick9993
      @kevinmithnick9993 2 หลายเดือนก่อน +1

      One possible solution is when configuring parameters, particularly current limits, you go for the upper limit. That value can give you an idea of that vsd capabilities
      Greetings from Colombia

    • @youngestincharge1998
      @youngestincharge1998 2 หลายเดือนก่อน

      @@engineeringsupport247 can you post more videos very helpful

  • @larrybassik2768
    @larrybassik2768 2 ปีที่แล้ว +1

    Great Content Learned Alot

  • @HCheatNcool
    @HCheatNcool ปีที่แล้ว

    When you call those a bridge rectifier, is that the same thing as SCR silicone current rectifier

    • @engineeringsupport247
      @engineeringsupport247  10 หลายเดือนก่อน

      I don't believe so, a bridge rectifier turns AC to DC, an SCR in my understanding is a Thyristor with a Gate that will only conduct when the right current is applied to the Gate.

  • @mikeadler434
    @mikeadler434 9 หลายเดือนก่อน

    👍👍