Worked on a lot of different VFD'S. Danfoss is the best. Great tech support. On 75 to 150 HP Danfoss old VLT 6000 & Newest FC200'S had trouble numerous times drawing high current say above 54 Hertz. Found out that too many room dampers were either closed or only partially open. Would place motor in bypass and it would draw over rated motor nameplate amps. Also had higher ampere where bearings were going so was told to ramp max speed down until repair could be done.
Hello I just replace a TR 150 drive with the VLT FC 102 but I cant make the motor run to max speed the manual says to check the output limits on 4-13 but it doesn't show on the display. It only shows 4-12 and 4-14. Any Idea on what am I doing wrong? Thx
Worked on a lot of different VFD'S. Danfoss is the best. Great tech support. On 75 to 150 HP Danfoss old VLT 6000 & Newest FC200'S had trouble numerous times drawing high current say above 54 Hertz. Found out that too many room dampers were either closed or only partially open. Would place motor in bypass and it would draw over rated motor nameplate amps. Also had higher ampere where bearings were going so was told to ramp max speed down until repair could be done.
Sir we have 2 kw VFD.. we face problem .. 3 mA out put Defrance.. we apply 16 mA with source..... Get out put 13 mA .... .. what's problem..
Regards
Thank you for sharing your experience and knowledge .
Very beautiful 🎉
Hello
I just replace a TR 150 drive with the VLT FC 102 but I cant make the motor run to max speed the manual says to check the output limits on 4-13 but it doesn't show on the display. It only shows 4-12 and 4-14. Any Idea on what am I doing wrong? Thx
Danfoss = Great
Hi ! can you tell me if with this setting if you can save the pump? because every two years the pump burns. Thank you
Sir how to increase the VFD brand HEDY industrial automation thank you
When i change the frequency and press OK it goes back to the settings saved before. Could this mean the drive is locked to do changes?
If I limit current, will the vfd trip or just adjust the speed?
Could the motor overheat due to an error in the parameters?
Hello sir, Is this type of speed settings process can be used in all types of VFD s.
Thank you.
Hand on equals manual?
Danfoss VLT - Alarm 1059 ( Modi-pro) , Help me pls!
Hai
how to change 50hz to 60hz frequency when it is in auto mode
Hand on mode can change..but how in auto mode
How to change in auto stupid tell me that
@@omsaiproperty8843 connect potentiometer
how do u set the cut off point for the pump you are running to leave a certain amount of volume in a tank so it dont suck it dry. thank u
use a sensor
Display. Lcd not working
bro just run the pump without checking if that is okay and doesn't do like overflows