Can 8 12/2 Romex be Put in One Multi-Cable Stacker by NEC?

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 ก.ค. 2024
  • Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Gardner Bender MCS-100W Multi-Cable Staple, Secures: (NM) Non-Metalic, Coaxial & Data / CAT 5, 100 Pk., Red: Amazon: amzn.to/2LtQGpC
    Gardner Bender #MCS-20W 20PK Wood Stud Staple: Amazon: amzn.to/377vxK6
    3M(TM) SI-1 Cable Stacker 25-Count: Amazon: amzn.to/3aanMoy
    Morris Products Cable Stacker - Secure Hold for Non-Metallic Cables, CATV, Telephone, Instrumentation, Security Cables - Polypropylene - Easy Installation - Pack of 25: Amazon: amzn.to/3oGgBZq
    Gardner Bender MPS-2100 Cable Boss Staple, ⅜ Inch., Secures: Coax: RG-6, Voice/Data: CAT 6, (NM) Non-Metalic 14/2, 14/3, 12/2, 200 Pk., White: Amazon: amzn.to/3a1qInF
    Gardner Bender PS-150 Plastic Staple, ½ Inch., 14/2, 12/2, 10/2 (NM) Cable, Quick / Easy Installation, for Romex, UF, (NM) & More, 100 Pk., White: Amazon: amzn.to/2JURiUM
    Gardner Bender GSE-205 Service Entrance Cable Staple, 2 in, 2 SEU, Grey: Amazon: amzn.to/37eKOZX
    DEWALT DCN701D1 20V Max Cordless Cable Stapler Kit: Amazon: amzn.to/36CA5rS
    National Electrical Code 2020, Spiral Bound Version (National Fire Protection Associations National Electrical Code) 1st Edition: Amazon: amzn.to/3omAbK5
    NFPA 70, National Electrical Code (NEC) Handbook, 2020 Edition 1st Edition: Amazon: amzn.to/37JUjPz
    NFPA 70, National Electrical Code (NEC), 2020 Edition: Amazon: amzn.to/39X0HFP
    Ugly’s Electrical References, 2020 Edition: Amazon: amzn.to/3lFqWD3
    Ugly’s Residential Wiring, 2020 Edition: Amazon: amzn.to/3lJXQTe
    Ugly’s Conduit Bending, 2020 Edition: 2020 Edition 3rd Edition: Amazon: amzn.to/3qnW2CF
    Ugly's Electric Motors and Controls, 2020 Edition Spiral-bound - July 10, 2020: Amazon: amzn.to/39SbyRB
    Ugly's Electrical Safety and NFPA 70E, 2018 Edition 4th Edition: Amazon: amzn.to/3oxE3Ik
    NFPA 70, National Electrical Code (NEC) Handbook, 2020 Edition 1st Edition: Amazon: amzn.to/37JUjPz
    Klein Loose Cable Stapler 450-100: Amazon: amzn.to/3hzLdYV
    Klein Tools 450-001 Heavy Duty Staples, 1/4 x 5/16-Inch Insulated Staples for CAT3 and CAT5e Data Cables, for Klein Tools Stapler No. 450-100: Amazon: amzn.to/3hzLr2d
    Klein Tools 450-002 450-003 and 450-004 Heavy Duty Staples,1/4", 5/16" and 19/32" Insulated Staples for Coax, CAT3, CAT5e Cables, for Klein Tools Stapler No. 450-100: Amazon: amzn.to/39tFBNl
    Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Fluke -A1-II Volt-Alert AC Non-Contact Voltage Tester: Amazon.com: amzn.to/13Tw7CY
    Leviton GFNL1-W Self-test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with Guidelight and LED Indicator, 15-Amp, White: Amazon: amzn.to/2I0nBRm
    Leviton GFTR1-W SmarTest Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, 15-Amp, White: Amazon: amzn.to/2Uvzm7c
    IDEAL Industries 61-164 SureTest Circuit Analyzer: Amazon: amzn.to/2Da3TwM
    Wago (100) 221-412 (50) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2WxqHxC
    Wago (25) 221-412 (25) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2HR6rDY
    Wago 221-413 LEVER-NUTS 3 Conductor Compact Splicing Connectors Qty 50: Amazon: amzn.to/2HMeYIr
    Wago 221-412 2-Conductor Compact Splicing Connectors (Pack of 100): Amazon: amzn.to/2Oy3Qzm
    Shipping, Entertainment, etc. Discounts:
    Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Prime Video Channel Free Trial: amzn.to/3mwgUEW
    Amazon Prime 30 Day Free Trial: amzn.to/3mqTcdq
    Amazon Music Unlimited Free Trial: amzn.to/35IlgC6
    Discount on Amazon Prime: amzn.to/37ZJmLN
    Audible Gift Membership: amzn.to/31Oxb08
    Try Audible and Get Two Free Audiobooks: amzn.to/37NMydc
    Amazon Business Account: amzn.to/31NGgGw
    Amazon Kids+ : amzn.to/2J6xFIt
    Exclusive benefits on Twitch: amzn.to/2HCWNpN
    Amazon Home Services: amzn.to/3jxIFez
    Kindle Membership Plans: amzn.to/31O9Pro
    Amazon Prime as a Gift: amzn.to/3jxxF0U
    Create an Amazon Wedding Registry: amzn.to/3jyHL1m
    Create an Amazon Baby Registry: amzn.to/35CGa5K
    Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com,

ความคิดเห็น • 319

  • @wim0104
    @wim0104 3 ปีที่แล้ว +3

    Holy Cow, talk about video-on-demand! Thanks!

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Why, do you have a load center install coming up?

  • @fritzmiller9792
    @fritzmiller9792 2 ปีที่แล้ว +1

    I love the focused simplicity of his videos and wouldn't change a thing. That said, this topic is a perfect place to point out that more than two cables under a staple is against code. Also, running cables in parallel on a 2x4 will most of the time violate the 1 1/4" rule. (Sometimes there is not a finished surface on the backside of the 2x4 and another run of cable is not a violation.)

  • @TheModelmaker123
    @TheModelmaker123 3 ปีที่แล้ว

    Enjoy seeing these new products as well as a refresher on checking to see if it meets NEC.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      I'm learning too from making the videos. :)

  • @ianmackenzie686
    @ianmackenzie686 3 ปีที่แล้ว +3

    Lol! I knew it would be okay and legal before I even watched the video...all of that 12/2 cable looked so pretty and neat in that contraption everything seemed right with the world for a moment!
    I'm so happy you're back on TH-cam and that I had the chance to resubscibe. Thanks for what you do!

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Welcome back to Sparky Channel! Yay!!!

  • @iandrew6347
    @iandrew6347 3 ปีที่แล้ว +2

    Interesting cable fixings . Cool video

  • @choimdachoim9491
    @choimdachoim9491 3 ปีที่แล้ว +7

    When I built my home I installed 40 breakers...this product would have saved me tons of trouble. On the interior Distribution Panel-wall I used 2 X 6 top and bottom plates with 2 X 4 studs turned sideways creating a double-sided wall with a space between so that I could distribute cables from the Panel with every wire being 1 1/2" from the wall exterior. The mistake I made was not staggering opposing studs. Stapling all those wires with studs back-to-back was a chore. The weakness of my framing of that wall was there's no way to install fire-blocking. Why 40 Breakers you ask? I took the Electrician's Bible at it's word plus I put no lights on circuits with outlets (4 Lighting Circuits). I put no more than 10 outlets on any Breaker and each bathroom had a dedicated circuit. My appliance-circuits had no more than 3 outlets, fridge had a dedicated circuit, each bedroom (4) had one dedicated circuit and there were a couple circuits dedicated to computers, etc. and 2 exterior outlet-circuits. In defense of my overkill, I spent 34 years as a Union Electrician.

  • @timothywhieldon1971
    @timothywhieldon1971 4 หลายเดือนก่อน +2

    I started useing these, i now keep a case of them in my truck. Its 100% legal, its a way of fastening. I do bathroom remodels and bathrooms often have BIG boxes with a ton of wires. these are fast and keeps the 2x4 wall from having a LOT of work

  • @chaseoes
    @chaseoes 2 ปีที่แล้ว +15

    "Flat cables may not be stapled on edge" - what kind of sick twisted person was out there doing this that made them make this rule!?

    • @sudokillall
      @sudokillall 4 หลายเดือนก่อน

      Many of the rules were preemptive in nature

  • @tommycho9068
    @tommycho9068 3 ปีที่แล้ว

    You are video makes it easy to understand and also makes my job easier to work.
    Thank you.

  • @fritzmiller9792
    @fritzmiller9792 2 ปีที่แล้ว

    This one of the best products to come out for residential wiring in a long time, I just love these. I wish they would come out with something similar that is rated for MC/AC cable. I really like how these isolate the cables away from the studs/ framing members and place them in their own plane. Great product. Great video too.

    • @timothyjewett625
      @timothyjewett625 2 ปีที่แล้ว +1

      They have a similar product called CJ-7 which is made by caddy. Also known as Colorado Jims. They are very handy

    • @fritzmiller9792
      @fritzmiller9792 2 ปีที่แล้ว +1

      @@timothyjewett625 thanks ! I am getting that right now👍

    • @LVL1Yo-YoGuy
      @LVL1Yo-YoGuy ปีที่แล้ว

      @@timothyjewett625 them multi tap bat wings?

  • @brentbeatty4171
    @brentbeatty4171 10 หลายเดือนก่อน

    Appreciate your insight brother

  • @NotSoCrazyNinja
    @NotSoCrazyNinja 3 ปีที่แล้ว

    This is exactly what I was looking for to improve cable management in an upcoming project. I HATE messy cables.

  • @damianduarte5908
    @damianduarte5908 3 ปีที่แล้ว +1

    I used these at work. They are good 👍 makes work faster

  • @tedmcdonald3377
    @tedmcdonald3377 3 ปีที่แล้ว

    Cool product, thanks Bill😊

  • @markchidester6239
    @markchidester6239 3 ปีที่แล้ว +4

    Years ago I used something similar called stack it.
    I'm a homeowner who built an addition.
    The inspector was impressed. Said he doesn't see electricians use those.
    In fact, he said I did a better job than most electricians.
    Pays to study

    • @kenbrown2808
      @kenbrown2808 3 ปีที่แล้ว +2

      some electical shops would rather spend $5.00 of time than use a 50 cent part.

    • @feelingtardy
      @feelingtardy 3 ปีที่แล้ว +1

      yeah, i remember using those when i helped wire houses back in the late 90's to early 2000's.

  • @timdouglass4934
    @timdouglass4934 3 ปีที่แล้ว

    I like them because they're very functional and make a nice neat job.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Yes, I think they have their place and they can keep cables neat and organized. Thanks Tim!

  • @waltmooredanwilson8754
    @waltmooredanwilson8754 3 ปีที่แล้ว +1

    Cool video. I learned about a new product I didn't know about before. Thanks for the info and thanks for sharing. Take care and God Bless.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      They say that any day you learn something is a good day! :) Thanks!

  • @garystgermain5372
    @garystgermain5372 2 ปีที่แล้ว +2

    Legal and provides a neat job

  • @robnystrom5690
    @robnystrom5690 3 ปีที่แล้ว +7

    Drywallers love more bumps on the stud,love the show sparky

    • @kainenmattison674
      @kainenmattison674 3 ปีที่แล้ว

      Never understood electricians inability to see past their own trade. Also they never pick up after themselves fuckers.....

  • @KadianUrquhart
    @KadianUrquhart 2 ปีที่แล้ว

    Thanks for your videos

  • @JayZen707
    @JayZen707 3 ปีที่แล้ว +1

    Usually that many cables are only present above or below a panel. Rarely would a product such as this be needed. I like to install 2 horizontal blocks above and below the panel for stapling. There's never a shortage of 2x4 scrap lying around most job sites that ends-up at the dump anyway, and it doesn't cost anything. I try very hard every day to cut plastic out of my life. This is unfortunately impossible, but I can do little things like use scrap wood versus buying plastic to cut down on our plastic problem. Love your videos and glad that you are doing them.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Excellent work Jason!

    • @jsncrso
      @jsncrso 3 ปีที่แล้ว

      Sound like you dont wire up many 3 gang switch boxes.

  • @NAVY_NFO
    @NAVY_NFO 4 หลายเดือนก่อน

    Very nice! Thanks

  • @WeatherNut27
    @WeatherNut27 3 ปีที่แล้ว +1

    I love those straps but never seen one with the clip in the back. Cool!

    • @ArkamasRoss
      @ArkamasRoss 3 ปีที่แล้ว

      Home depot has these particular ones.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      Yes, I prefer the ones with the clips.

  • @commercialelectrician133
    @commercialelectrician133 3 ปีที่แล้ว

    Great video

  • @THEELECTRICSIDEOFTHINGS
    @THEELECTRICSIDEOFTHINGS 3 ปีที่แล้ว +1

    That's the first time I've ever seen one of those looks very useful it makes the job very neat I'm an industrial electrician and I don't usually use Romex that's what we call housewire in Canada

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Thanks!

    • @Jason_Canada
      @Jason_Canada 2 ปีที่แล้ว

      Ok iam gonna help you ..do not put the outside light above the door ..use coach lights on the side

  • @AsHellBored
    @AsHellBored 3 ปีที่แล้ว +1

    I like how these are daily information/quizzes, but my attention span is not this long

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      OK, I'll try to get right to the point with them, thanks!

  • @Abcdefghi4093
    @Abcdefghi4093 3 ปีที่แล้ว +25

    Can we get a video on how many wires can go through each hole in a 2x4, 2x6, etc. If the hole is 1/2", 3/4", etc.? Love the info 😀

    • @Jason_Canada
      @Jason_Canada 2 ปีที่แล้ว +2

      In Canada its a total of 3 cables ..basically because of wire abrasion

    • @Abcdefghi4093
      @Abcdefghi4093 2 ปีที่แล้ว +1

      @@Jason_Canada no mater the size of the wood?

    • @Jason_Canada
      @Jason_Canada 2 ปีที่แล้ว +2

      @@Abcdefghi4093 i believe you mean hole size and your correct

    • @SuperBadGab14
      @SuperBadGab14 2 ปีที่แล้ว

      @@Jason_Canada by curiosity what article of the CEC talk about that? Thanks!

    • @homesteadhaven2010
      @homesteadhaven2010 2 ปีที่แล้ว +1

      I was told by my inspector is the hole can't be filled more then 40% with wire. I used 7/8 holes in my 2x4 and was allowed (2) 12/2 romex thru each hole. Size of the board doesn't really matter. It's the size of the hole. The 40% rule...

  • @samuelt2072
    @samuelt2072 3 ปีที่แล้ว

    Yes

  • @ScrewThisGlueThat
    @ScrewThisGlueThat 3 ปีที่แล้ว +1

    Ding, Ding, Ding.... We have a winner.

  • @tomkristman1456
    @tomkristman1456 3 ปีที่แล้ว

    I do enjoy these videos but I think you should do an in depth install of the generac generators with ats. It would pull in a lot of views.

  • @gurjindersingh199
    @gurjindersingh199 2 ปีที่แล้ว

    I think these are reasonable. Sometimes when wiring a house with 2x4 interior framing it's really difficult to get all the switch legs amd power in and out down to the 4 gang box even 2 stacked together neatly on the stud it's too close to the sides of the studs. I think these have their place just don't use them for everything.

  • @garydirkse9900
    @garydirkse9900 3 ปีที่แล้ว +10

    The NEC has rules about adjacent cables over 2 feet being derated in ampacity.

    • @simmcowaPang122
      @simmcowaPang122 3 ปีที่แล้ว +1

      Code?

    • @zerosparky9510
      @zerosparky9510 3 ปีที่แล้ว +1

      @@simmcowaPang122 . I do think it is in the NEC
      I would have to dig out my code book. But look up about derating of cables run close to each other.

  • @toolbeltworkshop6692
    @toolbeltworkshop6692 3 ปีที่แล้ว

    Thanks for this video Bill.. Normally I would not feel comfortable as an Electrical Inspector and Instructor with this since as the cables go up through the top plate, some electricians would drill out a single large hole and run all 8 cables through it, once they put in the fire stop, 334.80 kicks in which says that Table 310.15(B)(3)(a) applies and now we have an ampacity adjustment “derate” based on 16 current carrying conductors which is a 50 percent reduction from the 90 degree column of table 310.15(B)16 in the 2017 code and table 310.16 in the 2020 code which brings us down to a maximum OCPD of 15 amps which might be ok depending on what they are feeding and we also need to know what continuous loads there are which will require those portions to be subject to 125 percent of the continuous load plus 100 percent of the non-continuous loads on the respective branch circuits. What happens if they spray insulation in that cavity and fully encapsulate those bundled conductors? Sometimes, these fancy gadgets can get the electricians in trouble, I think it’s best for the electrician to always separate the NM-B cable and assume that it will be encapsulated in foam insulation or fire stop so that they have nothing to worry about. Again thanks Bill for your great videos.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Thanks!

    • @kenbrown2808
      @kenbrown2808 3 ปีที่แล้ว +1

      number of wires in the support is totally different from number of wires through a hole. that sprayfoam they put in the holes is a wire killer.

  • @garydudgeon
    @garydudgeon 3 ปีที่แล้ว

    Good morning Sparky. I was betting that the Gardner Bender product if properly placed on the stud was ok. Good company with a reputation of making good reliable products and tools that make electricians lives easier. Good video.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Well I did stretch their UL listing to the limit. I don't think I would put 8 12/2 in the device in actual practice but it's good to know that I can if I have to.

    • @garydudgeon
      @garydudgeon 3 ปีที่แล้ว

      @@SparkyChannel Agree, really eight together is too much unless absolutely no other way but if they have to be close neatly organized is best.

    • @kenbrown2808
      @kenbrown2808 3 ปีที่แล้ว +1

      actually, I've always found GB products to be slightly less efficient to use than other brands.

  • @SgtJoeSmith
    @SgtJoeSmith 3 ปีที่แล้ว +2

    It better be cause I just done it last week

  • @user-wk7wv8rn8h
    @user-wk7wv8rn8h 3 ปีที่แล้ว +3

    I have never seen anything like this in the UK; I thought I was ahead of the curve with my dewalt stapler

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      I love my DeWalt cable stapler!

  • @Eddy63
    @Eddy63 3 ปีที่แล้ว +5

    Wild Bill , has any of the people who wrote the NEC Code ever worked out in the field ??? Lol ... I'M glad some body like yourself can understand it ... And thanks for sharing your knowledge with us ...

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      I really doubt it!!! LOL, funny question! Thanks Eddy!

    • @JasonW.
      @JasonW. 3 ปีที่แล้ว +3

      Written by engineers for engineers.
      Used by electricians and inspectors.
      Fully understood by no single person.

    • @MasterTheNEC
      @MasterTheNEC 3 ปีที่แล้ว +4

      False....alot of us on CMP Panels are Master Electrcians and have worked in the field for decades. Also, the NEC changes based on "PUBLIC INPUTS" by individuals and not simply us sitting at a table thinking of things to add. This shows folks have no clue what goes into the development of the NEC.

    • @ronald5728
      @ronald5728 3 ปีที่แล้ว +1

      @@MasterTheNEC Excellent points

    • @Jason_Canada
      @Jason_Canada 2 ปีที่แล้ว

      If Bill dont know it ..I do willing too help who ever I can

  • @maestrovso
    @maestrovso 2 ปีที่แล้ว

    I take the quiz. It is legal as all 8 romex are secured at the required intervals. The inset gives them the protection from screws and nails. It is like when you run a single romex and secure it to the middle of the stud.

  • @kenbrown2808
    @kenbrown2808 3 ปีที่แล้ว +1

    what I didn't guess was that it could only accommodate two 3 conductor cables.

  • @lindseyyah1
    @lindseyyah1 3 ปีที่แล้ว +2

    yes its legal

  • @Clayform14
    @Clayform14 3 ปีที่แล้ว +3

    So flat 12/3 are not shown on the package as being allowed. ???

  • @5_fun_facts123
    @5_fun_facts123 3 ปีที่แล้ว

    Don't run into that many very often, great video. Hey Bill can you do a video on use of deox? I have heard it is not needed with today's aluminum chemistry. I called and talked to a specialist at Eaton, and they said they do not instruct to use it on their breakers or terminals in the load centers.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Interesting, thanks!

    • @kenbrown2808
      @kenbrown2808 3 ปีที่แล้ว +1

      I saw that video, too. use the deox. the next guy will be much less likely to curse you.

  • @dwoodog
    @dwoodog 3 ปีที่แล้ว +3

    My OCD'ness approves of that level of cable management.

  • @guyjones4936
    @guyjones4936 3 ปีที่แล้ว +6

    Jurisdictions often have extra rules. In our area, these are not allowed to be used to maximum capacity because our inspectors say it violates the NEC code concerning bundling of cables.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +2

      Thanks Guy!

    • @glasshalfempty1984
      @glasshalfempty1984 3 ปีที่แล้ว

      Can't stand inspectors like that.

    • @travismeyers3516
      @travismeyers3516 3 ปีที่แล้ว +4

      Inspectors often aren’t knowledgeable enough about their own jurisdictional code to be qualified to inspect in their jurisdiction.

    • @thomasmarable6818
      @thomasmarable6818 2 ปีที่แล้ว

      Your inspectors really need to go to school

    • @stephensalvador6667
      @stephensalvador6667 4 หลายเดือนก่อน

      Anything over 9 current carring conductors must be deratrd. That's no more then 4 Rome. Even in conduit no matert the size same rule applies no more then 9 current carring conductors before derating

  • @larrys8086
    @larrys8086 ปีที่แล้ว +4

    IMHO there seems to be a conflict between what the NEC says and what the manufacturer's document states. Some here say that the cables are being bundled, but if installed according to the manufacturers instructions, there are slight air gaps between the cables, so, is this installation truly bundling? The NEC says that if you follow the manufacturers installation instructions, it should pass code.

  • @MrTooTechnical
    @MrTooTechnical 3 ปีที่แล้ว

    Those should be code. They make the wiring look pretty

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Good morning Dave! Yes, they look quite organized.

  • @HapyHippie4.20
    @HapyHippie4.20 2 ปีที่แล้ว

    I’m having a hard time referencing how many NM-B sheathed cables (12/2&3w/gr) I can run through a 3/4” hole? Many channels say 2-3, but there’s a difference between 2&3! In my particular case I can easily pull (2)12/2w/gr & (1)12/3w/gr through a 3/4” hole inside the wall up through the ceiling going into the attic,but should I? Thanks for any help you can lend.

  • @anthonyelectric6045
    @anthonyelectric6045 3 ปีที่แล้ว

    And isn’t that much better? Use them anywhere on walls and ceiling joist. I’m with ya Bill👍

  • @Chris_In_Texas
    @Chris_In_Texas 3 ปีที่แล้ว +4

    Just an FYI the Amazon website and at 3:51 show figure 2, don't follow this, if you want to maintain your CATx rating. You never run communications/data and power cables parallel next to each other. Always space apart and if you must cross a data cable with power always do it at right angles only. NEC specifies (I don't recall the section) a minimum of 8" separation between UTP and power cables and then 2" between STP and power cables. Also considering 4:09 that RG6 (6.85mm) has a larger diameter than RG59 (6.15mm) I am not sure how that is possible?

    • @miket5506
      @miket5506 3 ปีที่แล้ว

      First, this isn’t labeled for use with CAT-X, only NM-B and RG6/RG59.
      Yes, RG6 is thicker than RG59...must be a typo. Doesn’t surprise me considering it’s probably made in china

  • @fonkenful
    @fonkenful 3 ปีที่แล้ว

    Pardon the question, but as “legal” as this application might be, is it really a good idea to stack that many NM cables that closely together? Sure they’re all flat, and looks like a very convenient and quicker installation than routing them side by side but what about capacitive or inductive coupling, or the joy in isolating and single one of those cables should the need ever arise? If you need that many cables in a wire chase, there’s always a stud or joist on the other side of the cavity,

  • @drewbush6535
    @drewbush6535 3 ปีที่แล้ว +1

    Sure I use them..I don't like them but works well

  • @tombell1906
    @tombell1906 2 ปีที่แล้ว +3

    They need to update the 14-3 and 12-3. It also comes in a flat cable

    • @timothyjewett625
      @timothyjewett625 2 ปีที่แล้ว

      Agreed, also I much prefer the 3M stackers over these. I find them sturdier and quicker

  • @hangngoaigiare
    @hangngoaigiare 2 ปีที่แล้ว

    Those drywall guys love this they will screw them right through

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว

      That would be a problem.

    • @hangngoaigiare
      @hangngoaigiare 2 ปีที่แล้ว +1

      @@SparkyChannel best is never stack wires like that. Bigger target for dummies

  • @Elfnetdesigns
    @Elfnetdesigns 2 ปีที่แล้ว +3

    Cool concept but I am curious to see the state of the holders in 10 - 15 years. Will the snap hold still hold or will it crumble? Also the NEC LOVES run on sentences lol

    • @erintheangry
      @erintheangry 2 ปีที่แล้ว

      plastic seems to hold up really well if there isn't drastic temperature changes or UV light involved so possibly? I guess we'll see in time.

  • @562sela8
    @562sela8 3 ปีที่แล้ว +2

    DOPE CHANNEL

  • @arthurperrea3714
    @arthurperrea3714 2 ปีที่แล้ว

    Sparky great videos I'm learning a lot .lm hoping you will help me out. Backhoe hit a underground 12_2 wire out to my chicken coop and it was repaired but a lot of ground water in hole . I like to make sure repair was done well and not leaking stray current into ground my electric those still work in coop .but I'm worry please tell me how to check for this or direct me to video . BEST REGARDS

  • @Marcel_Germann
    @Marcel_Germann 3 ปีที่แล้ว

    Does such a construction have an impact on the current rating of the cable? Here in Germany it does. The fuse rating of a circuit depends on the way the cable is installed, and how many cables are in the range and if they have direct contact or a spacing in between them of the size of the outer diameter of the cable (our cables are mostly round). It's about heat dissipation and to prevent that the conductor temperature gets above 70°C (158°F). That's the critical temperature for PVC insulation, at that temperature it starts to degrade, and the effect is cummulative. Meaning the insulation becomes more and more damaged with every overload, until it completely fails.
    The way cables are installed depends on: Wall thermally insulated, cable embedded into plaster, buried into the ground, hanging in the air, installed in cable trays, surface mounted (wall or ceiling), cable trench, hanging outdoor on a supporting cable. It's also of interest if it's a single- or a three-phase circuit.
    Found this one on a british site, we use the same system:
    www.voltimum.co.uk/sites/www.voltimum.co.uk/files/fields/attachment_file/gb/others/T/2008121096912008120444055868.pdf
    But three-phase is uncommon in british residential installations. So they didn't cover it in the PDF. The BS 7671 is the regulation for electrical installations, so that's their NEC.
    I got a slide rule for the different methods, numbers of cables next to each other, and wire sizes. So I can read the maximum rating of the breaker. Also got one for voltage drop, depending on cable length, rating of the breaker and the operating current, this is for designing a circuit and to see how long can that cable be and of which size and get an acceptable voltage drop that's not too high. Or should I better install one size larger to keep the voltage drop lower at the same length of cable?

    • @ShadowThiefGaming
      @ShadowThiefGaming 3 ปีที่แล้ว +1

      We pretty much have the same rules here in the use for THHN-2 wire and others thats aren’t nm cable. When you start to use THHN-2 you have to consider bundling, voltage drop, derating for heat in we’re the pipe is located what kind of pipe used and how many conductors in the pipe. Anything over 3 current carrying had to get derated. In residential I noticed it’s all up to the inspectors if they are lenient on using these listed products by adding all the cables together, or the inspector would just say it’s not allowed only can have 3 current carrying conductors and need to add another support.
      Basically in residential it’s a little easier to do this

  • @tobloo174
    @tobloo174 7 หลายเดือนก่อน +1

    Hi M. Sparky...Still one question about this product. How can you install this device if you want your cables going cross floor joist if you dont want to drill through all of them, under second floor and over suspended sealing for example ?

    • @KLAWNINETY
      @KLAWNINETY 4 หลายเดือนก่อน

      A different product made by rack a tiers exists for the purpose you've outlined. It's just a plastic deal with like 8 holes in it for supporting your home runs across joists

  • @KrazyKajun602
    @KrazyKajun602 ปีที่แล้ว

    what about running nm cable in the attic on ceiling joist for nec 2020 code? Do you have to staple or not?

  • @VengaboysFansiteEI
    @VengaboysFansiteEI 3 ปีที่แล้ว +9

    Now you need to make a video that explains how the WAGO lever nuts meet code for the real stubborn wire nut loving electricians.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +3

      Excellent suggestion, thanks!

    • @ethelryan257
      @ethelryan257 2 ปีที่แล้ว +1

      Please!!!!!!!!!

    • @NickFrom1228
      @NickFrom1228 2 ปีที่แล้ว

      I'm glad you specified lever nut. Wago also makes push in connectors which I'm not a fan of but the lever nuts are good.

  • @garystgermain5372
    @garystgermain5372 2 ปีที่แล้ว +1

    It is very legal

  • @Lilmiket1000
    @Lilmiket1000 2 ปีที่แล้ว

    Can I email a picture to you? I need to know if the way this cable stacker is used is legal. Also, I only have like 4wires to run. Do I stack all 4 in one slot or put 1 cable per slot? This seems like overkill for me. Also, I thought the point was to secure the cable. If I only have 4 it's going to fit in there very loosely. Which I have no problem with if it's legal. I hate for the wires to fit snug because if you need more wires pulled out a little in the future you cant do it. I learned from a guy to make a roll or loop of wire in the wall after the staple exactly for that purpose. Per your channel though from what I have gathered is that its ok to loop after the staple so long as the loop of wire doesnt exceed 14inches in length. correct?

  • @scotttribout1150
    @scotttribout1150 3 ปีที่แล้ว +3

    My question is, how does this compare to bundling? And the NEC rule on bundling?

    • @MasterTheNEC
      @MasterTheNEC 3 ปีที่แล้ว +3

      The rule is where you do not maintain spacing. If you use these devices as listed you are maintaining spacing. The NEC doesn't give a "value" for what is considered enough spacing...just demands that you maintain it or otherwise you will have to make adjustments accordingly. Until a separation, value is listed in the code (becareful of what you ask for) this will be how the inspectors should rule if they adhere to the NEC.

  • @Sparkeycarp
    @Sparkeycarp 2 ปีที่แล้ว +3

    I was surprised to see the 12/3 and 14/3 nm cable was reduced to 2 slots and not able to use all 4 slots. Does not make logical sense to me. Must be some heat rating calc. Overkill.

  • @1tufgt
    @1tufgt 2 ปีที่แล้ว +2

    Can these be used for network cables? I see it says coaxial but do t see anything for network.

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว

      Yes, they can be used to organize network cables as well.

  • @jcaleca60
    @jcaleca60 ปีที่แล้ว

    I guess right ✅️

  • @mrevohk7423
    @mrevohk7423 2 ปีที่แล้ว +8

    Rev up your Romex!

    • @Squay313
      @Squay313 2 ปีที่แล้ว

      haha! foreal

  • @tomkristman1456
    @tomkristman1456 3 ปีที่แล้ว +1

    If it fits it ships

  • @maxslomoff
    @maxslomoff ปีที่แล้ว +3

    The code says when more then 3 conductors (not counting neutrals) are bundled together for more then 24” then you must derate. are you saying these clips keep the pairs of cables separated with the plastic enough to allow you to use them at their full rating? or derate the whole bundle?

    • @chvydrptop
      @chvydrptop ปีที่แล้ว

      Think bundling only comes into play when running wires for more then 24". Here is a good video that touches on that th-cam.com/video/HTvaemH1hic/w-d-xo.html

    • @Fredjikrang
      @Fredjikrang ปีที่แล้ว

      Also, for NM cable specifically you are allowed to use the 90 C rating for ampacity when derating. Using that method you are still over 20A ampacity until you exceed four 12/2 cables bundled together through insulation. See 334.80. The code is somewhat unclear on derating NM bundles in open air, but I think it would default to the requirements of 310.15(C).

  • @lornes7526
    @lornes7526 3 ปีที่แล้ว +1

    Can the edge tab be trimmed off so it can sit flush on the midpoint of a floor joust, and do they meet code for cable securement within the required distance of the panel?

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +2

      They meet code if you follow the labeling and instructions. You would need to ask your inspector if you could modify them like that. I don't think it would be any problem.

    • @lornes7526
      @lornes7526 3 ปีที่แล้ว +1

      @@SparkyChannel
      And it is not a problem. They can be modified to sit flush, and they meet code for cable securement close to the panel as per my inspector. Thanks for the response.

  • @lostintime8651
    @lostintime8651 2 ปีที่แล้ว +1

    You said four and a half feet according to code how far apart are you putting these wire holders?

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      Less than that. WAY less. I usually use three for a switch box if the ceilings are under 10 ft.

  • @johns1263
    @johns1263 ปีที่แล้ว

    Can't find anything in NEC that would stop me from using these on a wooden raceway put across floor joists in a unfinished basement. Any thoughts?

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      Technically, you are probably right, you could, but the inspector probably wouldn't like it. If you are using a running board anyway, just make it wide enough to staple all your runs to it.

  • @jasonritchie6827
    @jasonritchie6827 ปีที่แล้ว +4

    the two cables per slot can actualy be fitted side by side and not jamed ontop of each other to allow even more space .

    • @TheRynovision
      @TheRynovision 8 หลายเดือนก่อน

      Only if you can still achieve that 1 1/4" requirement. Not sure what this brands measurement for the front face of the wire gap is but I would hope it's not under that and you are right. I think he stacked them this way to either keep that distance or to make the video questionable.

    • @Californians_go_home
      @Californians_go_home 8 หลายเดือนก่อน +2

      @@TheRynovisionit’s an 1 1/4 automatically off the front and the back of a 2x4 stud. Front side or back side. They are designed to go inside a 2x4 wall cavity and maintain 1 1/4 on both sides. It not only states this in the video, but would never be put to market if it wasn’t . Those cables can be installed side by side within the space. All you have to do is look at the clip and common sense takes it from there.

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน +1

      I was going to say the same thing. That's how I've always done it. I've never stacked them like that.

  • @Bryster51
    @Bryster51 3 ปีที่แล้ว +4

    Any cable derating needed since minimum cable spacing of one cable diameter is not met?

    • @thomasmarable6818
      @thomasmarable6818 2 ปีที่แล้ว

      No its been approved for no de rating.

    • @pingpong9656
      @pingpong9656 ปีที่แล้ว

      @@thomasmarable6818 Really? Where could I get info on this?

  • @tomgarrison8492
    @tomgarrison8492 2 ปีที่แล้ว +2

    In this example, we see eight (8) 12-2 NM-B cables bundled together with no spacing exceeding a length of 24 inches. That's 16 current carrying conductors. Table 310.15(C)(1) says 10-20 current carrying conductors must be derated by 50%. According to Table 310.16, #12 THHN conductors (NM-B) have an ampacity of 30A. 50% of 30A is 15A. It's possible that not all of those conductors can be energized simultaneously - we don't know by this example. But it would be safe to say at least 10 conductors (62.5%) in this group would be able to be simultaneously energized, which would still require a 50% derating.

    • @mikefochtman7164
      @mikefochtman7164 2 ปีที่แล้ว +2

      Isn't THHN and Table 310.15 and 310.16 for number of conductors in a conduit/cable? There, the heat from so many conductors has to dissipate in the conduit. But this shows separate NM-B cables clearly spread out more than 16 conductors in a conduit so not sure that derating applies. These are eight separate cables and are even spaced in pairs of two with free air between them.

    • @martinh.birnie5582
      @martinh.birnie5582 2 ปีที่แล้ว +1

      @@mikefochtman7164 Refer to 334.80.. Ampacity. I'd argue there is no need for derating as this section is only in relation to NM flat cable

    • @martinh.birnie5582
      @martinh.birnie5582 2 ปีที่แล้ว +3

      Additionaly...if any insulation, even sound batting is installed after the supporting...then derating is needed

  • @wkrp10splayer19
    @wkrp10splayer19 2 ปีที่แล้ว +11

    scotty kilmer parody while do electrician work

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว +3

      LOL!

    • @midnightgardener8346
      @midnightgardener8346 2 ปีที่แล้ว +3

      Lol I was just thinking he sounds just like him

    • @ShainAndrews
      @ShainAndrews 2 ปีที่แล้ว +1

      Cringe. One is not knowledgeable while the other is.

    • @LVL1Yo-YoGuy
      @LVL1Yo-YoGuy ปีที่แล้ว

      Dang some scotty fans in that house.🇺🇸

  • @mikes7047
    @mikes7047 ปีที่แล้ว

    I'm in canada and haven't checked the code book buy I'm thinking there may be an issue with hotspots

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      There's not. The way he stacked them, I might agree with you, but that's not how they usually get used. They fit two side by side in one slot, eliminating the pinch where it would get hot.

  • @rockoeasy9150
    @rockoeasy9150 3 ปีที่แล้ว

    Can these cable stackers be used as a means to secure within 12 inches of entering an electrical panel. Do they have to be attached to a stud or can they be attached to a piece of plywood like what your panel box is connected too. Thanks in advance

    • @thisgame1499
      @thisgame1499 3 ปีที่แล้ว +1

      you can nail them to plywood around your panel anywhere that you would staple the wires

    • @PittsburghofCommander
      @PittsburghofCommander 2 ปีที่แล้ว

      Yes

  • @pingpong9656
    @pingpong9656 ปีที่แล้ว +1

    How do you pass the 8 cables through the bottom and top plates? Would it be four holes or one large hole?

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว

      4 holes, 2 each hole.

    • @shawnshurtz9147
      @shawnshurtz9147 ปีที่แล้ว

      ​@Sparky Channel 2 holes 4 each hole would work as well correct?

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      @@shawnshurtz9147 Only if you drill bigger holes. You can drill 1" 1/8" inch holes in a 2x6 wall and well exceed the 'hole to edge' spacing and run four conductors in it.

  • @konamanstudio2447
    @konamanstudio2447 3 ปีที่แล้ว

    Most products you show in you use in your demo are all OK to use usually in never put anything what's not being me still the answers usually yet ☃️🎄🍻🍺🎄☃️

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      That's true but I'm going to trick you guys on at least one of these. I'll set up one of these scenarios and then go to the code and it's going to flunk. Just to keep everyone honest. :) ☃️🎄🍻🍺🎄☃️

  • @sailingeden9866
    @sailingeden9866 3 ปีที่แล้ว +3

    I assumed that no one would invest in making and selling them if they were against code to use.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      Thanks!

    • @Caderic
      @Caderic 3 ปีที่แล้ว

      You would be surprised!

  • @gwil6100
    @gwil6100 3 ปีที่แล้ว +5

    What about grouping factor and consideration for the disipitation of heat generated by the load. With these cables grouped tightly like this surely this could be a fire hazzard?

    • @kainenmattison674
      @kainenmattison674 3 ปีที่แล้ว +1

      With them all traveling in the same direction heat build up should be minimal

    • @PittsburghofCommander
      @PittsburghofCommander 2 ปีที่แล้ว

      Yes and no, Keep in mined they have to be strapped properly

  • @victormendoza6306
    @victormendoza6306 3 ปีที่แล้ว

    Great 👍 información but is it works in Illinois

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      I don't know, Chicago is tougher than other places in the US.

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว

      A lot of areas in illa-no-toys you can't use nm-b Romex all has to be in conduit

  • @joeweatlu5169
    @joeweatlu5169 ปีที่แล้ว +1

    I see you used both the nail and screw to mount the one in your example. Actually the nail is for wood studs and the screw is for metal studs. No need to use both according to instructions.

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว

      Thanks!

    • @adamplummer2190
      @adamplummer2190 ปีที่แล้ว +2

      For what I read screw is for either. If it's near a corner, probably good idea to use both to prevent twisting.

  • @Jason_Canada
    @Jason_Canada 2 ปีที่แล้ว +1

    Yes with de rating

    • @thomasmarable6818
      @thomasmarable6818 2 ปีที่แล้ว

      With de rating still can be use on 20 amp circuit

    • @elbuggo
      @elbuggo 2 ปีที่แล้ว

      @@thomasmarable6818 20A also in 14G wire?

  • @mrlibowski493
    @mrlibowski493 2 ปีที่แล้ว +2

    NEC says if done for more than 24" it's bundling and you would have to derate the conductors.

    • @tysonbrown249
      @tysonbrown249 2 ปีที่แล้ว

      I agree. It's totally legal to install them like this, but the inspectors in our area will require you to derate the ampacity of the cables if there are more than nine current carrying conductors in a bundle of 24"+, and they consider this type of thing to be bundling.

    • @pingpong9656
      @pingpong9656 ปีที่แล้ว

      @@tysonbrown249 Can you pass more then 10 or more conductors through a single hole without de-rating? I assume that as long as you fan out after/before the hole you are within the 24" rule.

    • @jasonrawls6959
      @jasonrawls6959 ปีที่แล้ว +1

      So you have to put them on a 15 amp breaker?

  • @sevendust07660
    @sevendust07660 6 หลายเดือนก่อน

    What if you have a mix of 14/2 and 14/3 leaving a 4 gang box for example? How many then?

    • @Californians_go_home
      @Californians_go_home 6 หลายเดือนก่อน +2

      14-3 are flat cable. They are not made the same as they used to be. Same with 12-3, it is now flat cable.

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      I usually try to give a 14-3 its own space, but if that isn't possible for some reason, I've put a 14-2 and 14-3 in one space and haven't ever had an inspector call me out on it.

  • @miket5506
    @miket5506 3 ปีที่แล้ว +5

    1:13 “do you think this is legal?”
    I don’t care if it’s legal, but I doubt it’d be in the electrical supply store if it wasn’t

  • @newjerseybill3521
    @newjerseybill3521 2 ปีที่แล้ว

    Too bad the instructions where so specific with coax. Technically you can use it for 75 ohm RG59 coax used for old school networks and cable TV, but not the slightly smaller 50 ohm RG58 coax used for radio communications.

  • @glasshalfempty1984
    @glasshalfempty1984 3 ปีที่แล้ว +4

    5:04 wait a second, what about NM-B flat 12-3? Are you just just not supposed to use flat 12-3 or 14-3 cable with these?

    • @mr.3phase228
      @mr.3phase228 3 ปีที่แล้ว +1

      Flat 12/3 and 14/3? Never seen that before.

    • @steven7650
      @steven7650 3 ปีที่แล้ว +2

      @@mr.3phase228 The new stuff is flat but it's wider not sure it would fit those.

    • @glasshalfempty1984
      @glasshalfempty1984 3 ปีที่แล้ว +2

      @@mr.3phase228 Romex brand, 12-3 with ground is flat and wider, like steven said. Not sure of any other brands though. I know it's been like this several years though, at least the Romex brand.

    • @mr.3phase228
      @mr.3phase228 3 ปีที่แล้ว +2

      @@glasshalfempty1984 I use romex brand nm cable, its NM-D so maybe that's why, or its a Canadian thing idk, pipe is better anyway

    • @glasshalfempty1984
      @glasshalfempty1984 3 ปีที่แล้ว +1

      @@mr.3phase228 ah, I'm not familiar with NMD but I think it is a Canadian thing so that might be why. Interesting! I'll have to look more into that later.

  • @chrisneill6239
    @chrisneill6239 2 ปีที่แล้ว +1

    320.15(B)(3)(a) 10 current carrying conductors in a bundle (which this most certainly is) require a 50% derating or adjustment

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว

      Thanks!

    • @algolove185
      @algolove185 ปีที่แล้ว

      @@SparkyChannel If its more than 2 feet than derating applies?

    • @pingpong9656
      @pingpong9656 ปีที่แล้ว

      @@algolove185 So does that allow more then 10 carrying conductors to be bundled through a hole in a joist? if they fan out again?

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      Article 320 is Armored Cable.

  • @gurjindersingh199
    @gurjindersingh199 2 ปีที่แล้ว

    Csn I wire my entire house with emt inside the walls like a school or a hospital ?

    • @homesteadhaven2010
      @homesteadhaven2010 2 ปีที่แล้ว +1

      Yes. My home in Minnesota is wired like that.

    • @bigqwertycat
      @bigqwertycat 2 ปีที่แล้ว +2

      Sounds unnecessary expensive

  • @user-dr2pg8fk2i
    @user-dr2pg8fk2i 3 ปีที่แล้ว +2

    So these are not allowed with 12/3 or 10/3?

    • @christopherprosser7438
      @christopherprosser7438 3 ปีที่แล้ว +1

      Look at the 4:14 mark yes they are aloud and 12/3 and 14/3 are also no longer round they are flat like 12/2 & 14/2

    • @Clayform14
      @Clayform14 3 ปีที่แล้ว +1

      I don't see 12/3 flat either. I see 12/3 round, but only 2 are allowed. Strange??

  • @gekorec
    @gekorec 3 ปีที่แล้ว +6

    I'd worry about heat build up. If there was a gap between each conductor similar to spark plug wires in a car.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      I would too. I was just showing what is code. You can always exceed code.

    • @thomasmarable6818
      @thomasmarable6818 2 ปีที่แล้ว +1

      @@SparkyChannel everybody talk heat what heat put the full 20 amps on for 3 hours on all cables and measure the heat, I bet it wont be anywhere near danger zone, plus most likely never will the circuit exceed 13 to 15 amps over along period of time. People need to go to classes and learn how electricity really works.

    • @thomasmarable6818
      @thomasmarable6818 2 ปีที่แล้ว

      @LabRat Knatz I was talking about the device in hand the derating is not necessary fir what was shown in the video. As far as de-rating goes most electricain do not know how to do it. And yes we do put full loads on wires and cables and measure the heat in our classes, thats how I know when installed correctly it not a problem.

    • @ClayAdams-zj8yf
      @ClayAdams-zj8yf 4 ชั่วโมงที่ผ่านมา

      Heat build up?

  • @mnoxman
    @mnoxman 3 ปีที่แล้ว

    Yea that's nice but past one or two of these they will branch off to their separate destinations. Looks really need if you want it to look like a data center.

  • @zman783
    @zman783 2 ปีที่แล้ว

    The coaxial rating is weird. RG-6 is larger diameter then RG-59. So how do they allow more of the larger cable then the smaller one? Maybe placement ??

  • @shawnshurtz9147
    @shawnshurtz9147 ปีที่แล้ว +6

    Wait you did derate for bundling more than 4 correct.

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว +3

      Yes, that's correct.

    • @toxsickdog
      @toxsickdog ปีที่แล้ว +1

      How many amps does the cable need to be derated?

    • @isaacd123id
      @isaacd123id 10 หลายเดือนก่อน +1

      @@SparkyChannelI’ve been struggling for this for years . In this instance why would you need to derate ? 310 says that current carrying conductors more than 24 inches need to be derated when together . But I feel like in this instance the wires are together for such a small portion …. Do you take it for the whole run ? I feel like it’s the same when you pull multiple wires in a stud hole.? There’s nothing that says otherwise though 😮losing my mind lol. Our inspectors allow us to zip tie throughout our runs to clean them up . Often at times we have tons of wires together .

    • @Californians_go_home
      @Californians_go_home 6 หลายเดือนก่อน

      @@SparkyChannel It doesn’t look like anybody responds here but I’ll ask anyway. Do multiple NM cables used as home runs using cable stackers, rated to hold up to 8 number 12 per manufacturer specification, have to be derated?? It says right on the package 8 number 12 and 8 number 14. Length of run is not specified, but it’s over 24 inches. Same applies for wall cavities that are insulated. Code says you can go my manufacturer specs. If I read the code right, nm cable rated at 90c is already derated based on amperage in the 60c column. 20 amp max number 12 and 15 amp max number 14. If that is true, 8 home runs could safely be used in a cable stack.

    • @bryanherman1035
      @bryanherman1035 2 หลายเดือนก่อน

      @@Californians_go_home The NEC would probably cop out to the AHJ if you actually asked them this question. Realistically, you just sort it out in the load calculation, and almost none of your conductors will be running more 80% their rating. So, 16A on a #12 and 12A on a#14. I've seen a lot of talk about cables heating up because of bundling, but I've never really seen it happen. And I've checked my own work too, because I wanted to know if it was true or not. If an inspector tried to call you out on it, I would point to the UL listing stamp on the bag and the specifications they give you. The manufacturers would have to put any de-rating spec on the package to get the UL listing.

  • @badguy622
    @badguy622 3 ปีที่แล้ว

    Do they have one made for 12/3 so you can get more than 2 on one strap?

    • @damianduarte5908
      @damianduarte5908 3 ปีที่แล้ว +1

      I used them before yea you can use 12/3
      And 10/2

    • @BluCappy419
      @BluCappy419 3 ปีที่แล้ว +1

      He's asking if there's a product listed to support more than 2 12/3s. Look into Erico "CADDY" CJs or "Colorodo Jims" they can support up to 6 10/3s to wood stud, 4 to metal stud, and can even do MC and AC cable. If you've got more than that, you ca use Caddy "gun brackets" and space them across the bay. The concern is wire bundling. You dont want to group too many cables together in a single bundle.

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว +4

      I would just use my new found method thx to (electrician u) use staples and tiewraps.

    • @badguy622
      @badguy622 3 ปีที่แล้ว

      Thank you everyone for the info! Love learning new tips and tricks for our trade!

  • @sylvesterstewart868
    @sylvesterstewart868 3 ปีที่แล้ว +2

    If you went more than 10' would you have to derate? (More than 3 CCC)

    • @jsncrso
      @jsncrso 3 ปีที่แล้ว

      no, derating only applies to wires in a cable, conduit or raceway!

    • @sylvesterstewart868
      @sylvesterstewart868 3 ปีที่แล้ว

      @@jsncrso And bundles.

    • @jsncrso
      @jsncrso 3 ปีที่แล้ว

      @@sylvesterstewart868 yes, but there are spacers in these clips so they are not classified as a bundle

    • @sylvesterstewart868
      @sylvesterstewart868 3 ปีที่แล้ว

      @@jsncrso The code isn't clear on on it but I guess it makes sense if everything at either end is right.

    • @jsncrso
      @jsncrso 3 ปีที่แล้ว

      @@sylvesterstewart868 The code says to follow the UL listing of the product. Separated wires are not considered a bundle

  • @gendunchophel3712
    @gendunchophel3712 3 ปีที่แล้ว +1

    Hi Bill
    Does bathroom outlet need afci breaker?

    • @PepperStone3
      @PepperStone3 3 ปีที่แล้ว

      Yes. Practically all single phase 120v 15A & 20A in dwelling units require AFCI protection.
      NEC 210.12

    • @mattolson7037
      @mattolson7037 3 ปีที่แล้ว +1

      No bathrooms do not need afci protection

    • @mattolson7037
      @mattolson7037 3 ปีที่แล้ว +1

      @@PepperStone3 According to nec 210.12 bathrooms are one of the few areas that do not need afci protection

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +2

      It's best that I don't give verbal answers to such questions. I'll have to make a video about it and back it up with the actual code.

    • @Flatearth69
      @Flatearth69 3 ปีที่แล้ว

      @@PepperStone3 hey peter lets not give out advice online if we dont know whats going on. you are going to get someone severely injured