The cheapest cable railing kit ever!

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.ย. 2024

ความคิดเห็น • 37

  • @lepeichia8117
    @lepeichia8117 4 ปีที่แล้ว

    a very clear construction detail thank you

  • @benberry8100
    @benberry8100 4 ปีที่แล้ว

    thanks for sharing this useful info.

  • @Starman-2112
    @Starman-2112 2 ปีที่แล้ว

    Hello My cable wire slipped out of the connector. Once a metal connector has been crimped down can the connector be widened uncrimped via a crimper tool so can insert wire? Or do i need to buy new connectors

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      Hi, the metal tensioner cannot be reused after being crimped. But you could choose our swageless cable tensioners like CB16, CB05, and CR59. You can check our website for more swageless tensioners - www.muzatarailing.com/collections/swageless.

  • @effinhaoli808
    @effinhaoli808 3 ปีที่แล้ว

    Hi do you have a formula to figure out how much shorter to cut cable to plan on minimal threads showing on bolts?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      Currently, we don't have the formula to help you calculate the length of the cable you should cut. We will feedback this to our technical team, thanks for your suggestion.

    • @palmpreuser101
      @palmpreuser101 2 ปีที่แล้ว +1

      A guy on another video said to measure the length of the run post to post, then subtract 1.5" from your cable length and that should work out perfectly.

  • @ricardohernandez5399
    @ricardohernandez5399 ปีที่แล้ว

    What is the maximum cable spacing allowed for this rail system?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  ปีที่แล้ว

      Hi, the max cable spacing is 15ft for this rail system.

    • @ricardohernandez5399
      @ricardohernandez5399 ปีที่แล้ว

      @@MuzataCableRailingLEDChannelI'm referring to the spacing for cable in regards to the 4" sphere test, not the post spacing. For example could i space the cables at 3.5" or what is the max?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  ปีที่แล้ว

      @@ricardohernandez5399 Sorry for misunderstanding your question. According to the IRC, the max cable spacing is 3.5". And we recommend 3" cable spacing for most projects in case of strict local code in some states.

  • @WaiNat
    @WaiNat 4 ปีที่แล้ว +1

    Thanks for sharing!

  • @666Hoplite
    @666Hoplite 2 ปีที่แล้ว

    What size bit do I use to crimp?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      There are 3/8 '', 11/32'' , 9/32'', 3/16'' 4 sizes bit you need to use. th-cam.com/video/skGKf9EPPkg/w-d-xo.html

  • @harriskw
    @harriskw 4 ปีที่แล้ว

    Do I need the hydraulic crimper? Or can I use a regular manual swaging tool (that I already own)?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  4 ปีที่แล้ว

      hi there.I think you need a hydraulic crimper for stainless steel swaging. Please search CT01 on our website to find it.www.muzatarailing.com

  • @misaco6197
    @misaco6197 4 ปีที่แล้ว

    So good😋

  • @kevinbhar9210
    @kevinbhar9210 2 ปีที่แล้ว

    I installed the 1/8" cable with swags. I noticed cable are becoming loose. Any advice?

  • @VARocketry
    @VARocketry 4 ปีที่แล้ว

    Do you manufacture your SS316 cable to a MILSPEC rating? Do you publish or provide a chemical analysis of your SS316 cable products? What other industrial standards govern corrosion resistance? Our installation will be in a marine environment.

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  4 ปีที่แล้ว

      Hi, thanks for asking. We can provide a chemical analysis of the T316 cable if you need it. You can contact us by email, our email address is support@muzata.com.

  • @johnyam3973
    @johnyam3973 4 ปีที่แล้ว +1

    加油

  • @kevinstartv5442
    @kevinstartv5442 4 ปีที่แล้ว

    👍👍

  • @1CarLightDIY
    @1CarLightDIY 4 ปีที่แล้ว

    thanks for sharing

  • @peterwilson1831
    @peterwilson1831 ปีที่แล้ว

    is there a more accurate way to measure the cable length so that when the screws are screwed in to tension, none (or very little) of the threads are left visible?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  ปีที่แล้ว

      Our video has detailed instructions on how many lengths of railing need to be cut for the corresponding cable railing, or you can check out our Amazon store, where each cable railing's picture description is indicated.

  • @arielwu8689
    @arielwu8689 4 ปีที่แล้ว

    Thank you for your sharing!

  • @lisamclaughlin4852
    @lisamclaughlin4852 2 ปีที่แล้ว

    Can you use this system and get the tension tight enough with a 12 foot length of cable?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      Hi Lisa, the answer is yes. For this system, we recommend the maximum span between two end posts is 15Ft. So you can tension the 12Ft length of the cable tight enough.

  • @americanpancakelive
    @americanpancakelive 2 ปีที่แล้ว

    Great system but I don't like the threads showing :(

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      Hi, thanks for your comment. We have an invisible terminal CR73, which can be hidden inside the wood post without threads showing. Here is the link to CR73:www.muzatarailing.com/products/cr73-2; And you can contact us by email; our email address is support@muzata.com.

    • @americanpancakelive
      @americanpancakelive 2 ปีที่แล้ว

      @@MuzataCableRailingLEDChannel thanks for the info- !!

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  2 ปีที่แล้ว

      @@americanpancakelive You are welcome; please feel free to contact us whenever you need further information.

  • @pennygreenler4351
    @pennygreenler4351 3 ปีที่แล้ว

    How long does it take for the cable wire to begin to rust?

  • @cheapwhiskey30
    @cheapwhiskey30 4 ปีที่แล้ว

    WHat is the recommended length from point to point? Can you go 16 feet?

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  4 ปีที่แล้ว

      Generally, the max span of CK17 is 20ft , for straight sections.

    • @MuzataCableRailingLEDChannel
      @MuzataCableRailingLEDChannel  4 ปีที่แล้ว

      Yes, it can. In order to ensure the safety and stability of the cable railing system, we recommend that the maximum distance between the two ends should not exceed 20'.