Understanding System Voltages, NEC 2020, (46min:29sec)

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ส.ค. 2024

ความคิดเห็น • 106

  • @Nahum17good
    @Nahum17good 3 ปีที่แล้ว +34

    Not only do you inspire me to be a better electrician, but you also inspire me to be a better person! God bless you and your family.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว +7

      What a lovely message, thank you.

  • @QuaabQueb
    @QuaabQueb 3 ปีที่แล้ว +14

    17:40 this is the type of energy and personality that makes a truly great teacher, a person so filled with not only the knowledge but also the drive, the passion and the overwhelming excitement to tell it to others.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว +2

      Thank you, I did get excited...

  • @noahmchugh3769
    @noahmchugh3769 3 ปีที่แล้ว +5

    Mike, I’m a 3rd year apprentice and I’ve heard your name a couple times and this is the first video of yours I’m watching and my first impression of you is excellent. What set that is how you start by giving our Father in heaven the glory.

  • @4eightyvolt
    @4eightyvolt 3 ปีที่แล้ว +2

    For those confused the illustration @ 3:00 is a typo. The primary should be "480/20 turns = 24v per turn" and the secondary should be
    "24v per turn x 5 turns = 120v". Mr. Holt explains it correctly though. Just fyi

  • @lawtonsegler1923
    @lawtonsegler1923 3 ปีที่แล้ว +3

    Regarding three phase autotransformers, I worked for an OEM that manufactured large three phase motor operated equipment that was sold around the world, so we used custom three phase autotransformers with taps configured for our existing 480v as well as 380, 400, and 575, all in one transformer. Large contactors were used to select voltages required by the unit under test. I know Hammond Power Solutions lists these in a catalog with common voltages, but they’ll also build you one to your specifications. I liked to use a company in Canada called Marcus Transformer. They’re real easy to work with, have a fast turnaround, and fair prices. If you call them they’ll answer in French, but will switch to English, lol…. Also, Staco Energy Products makes super slick systems like this and will build you an all-in-one package to your specs, and they provide expert advice. We even had one of their 300 KVA three haze variable autotransformers that would deliver anything from 1 to 480v. It was pretty cool. I know this really isn’t helpful to most of the audience, but knowing this stuff exists may come in handy.

  • @rickpina5000
    @rickpina5000 2 ปีที่แล้ว

    This is gold. The knowledge you give us, no one will ever be able to take away.

  • @phillbenitez4216
    @phillbenitez4216 3 ปีที่แล้ว +2

    Thanks Mike. God bless you all!

  • @lauratanner8475
    @lauratanner8475 2 ปีที่แล้ว

    Mike Holt is a Dynamo!! Always passionate and right on the mark. Probably no one else has ever had so much working knowledge of the code.

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      I love helping you guys, so I guess that is obvious!

  • @seantreakle1174
    @seantreakle1174 10 วันที่ผ่านมา

    What concerns me Mike when You're gone who's going to take over. Somebody has to come forth and stand and take your place. Without these programs the industry suffers. I couldn't imagine not having these programs Sean Denver Colorado

    • @MikeHoltNEC
      @MikeHoltNEC  9 วันที่ผ่านมา +1

      Sean, when I'm gone MHE will still be there with great leadership and technical skills. But these Mike Holt Video posts will not be replaced... so I hope others value what I'm sharing and show gratitude and not give me any crap.

  • @Proiectediversediy
    @Proiectediversediy 3 ปีที่แล้ว +2

    Thanks Mike.Congrats from Romania.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      Wow, thank you and God Bless

  • @unsanctionedshortstories5778
    @unsanctionedshortstories5778 2 ปีที่แล้ว

    Mike Holt the legend. Sir thank you for all your work and we appreciate it!!!!

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      Thank you and you are most welcome.

  • @NOTTV7
    @NOTTV7 2 ปีที่แล้ว +1

    Thanks Mike very much needed information

  • @marcemarce9821
    @marcemarce9821 2 ปีที่แล้ว

    He said, ook I am been told too fast lol Thank you Mike there is no Mike you're making a big difference for many people, thank you God bless you, I don't have my licence but I am trying.

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      I don't know the term 'I'm trying.' This appears to provide lots of excuses to not comit. Please call 352.360.2620 and allow my staff to get you on a program to 'pass' your exam the first time.

  • @mahadihasan93
    @mahadihasan93 3 ปีที่แล้ว +2

    As always outstanding content. Thank you.

  • @steven7650
    @steven7650 3 ปีที่แล้ว +2

    IIRC you can use whatever color scheme you want as long as you're consistent in the building. So if you make your high leg zebra pink striped, well that's what all of them in that system have to be. I believe there's an exception for repair work and it must be permanently clearly labeled that the colors do not match the rest of the facility.

  • @elc2k385
    @elc2k385 3 ปีที่แล้ว +1

    This video is going in my Favorites.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      I love this topic. It answers so many questions.

  • @murraywendman8222
    @murraywendman8222 3 ปีที่แล้ว +1

    Thanks Mike

  • @NameLess-ks4fi
    @NameLess-ks4fi 3 ปีที่แล้ว +3

    Mike is the GOAT

  • @Lionofjudah308
    @Lionofjudah308 3 ปีที่แล้ว +2

    Amen brother

  • @85agyoung
    @85agyoung 5 หลายเดือนก่อน

    In the video for a Highleg system you show 3 windings on the secondary side. Typically a highleg system would only have 2 windings. This would be the primary purpose for a high-leg or open delta saving money or reducing material. The 2 windings especially on the utility side would be used. The vector of this setup would look like a T. With the node of the T being your neutral connection. The Y axis in the vector would be your high-leg or 208 to neutral voltage.

    • @MikeHoltNEC
      @MikeHoltNEC  4 หลายเดือนก่อน

      A closed or open Delta secondary with a neutral will both give a high-leg voltage of 208V.

    • @85agyoung
      @85agyoung 4 หลายเดือนก่อน

      Agree with the closed delta giving you the same results. I have never installed or seen a closed delta highleg.
      Keep up the awesome videos! They have helped me out with getting a better understanding of the NEC.

  • @poolsdoc9178
    @poolsdoc9178 3 ปีที่แล้ว

    Amazing theory book, every electrician should have it 👌👍👏

  • @jolyonwelsh9834
    @jolyonwelsh9834 3 ปีที่แล้ว +2

    You are not allowed to use slash rated breakers on an ungrounded or a corner grounded system. I wish they would make all 2 pole breakers straight rated for this reason. It would not cost much more in that they would all be made to the same standard. After all, all three pole breakers are straight rated.

  • @1xtechnologiescablecompany272
    @1xtechnologiescablecompany272 3 ปีที่แล้ว

    Fantastic job Mike!

  • @brianmcdermott1718
    @brianmcdermott1718 3 ปีที่แล้ว

    Great info. As usual. Thanks Mike.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      You are very welcome

  • @tfun101
    @tfun101 5 หลายเดือนก่อน +1

    Mike people keep telling me I’m wrong..I just want to make sure. If I have a 480 primary and 208/120 secondary transformer, or any other kind of transformer for that matter..Let’s say the neutral on my secondary is bonded correctly with a SBJ and I have an effective ground fault current path, and everything is correct. EXCEPT I don’t ground my transformer to the dirt, or building steel, or a water pipe or anything else. I still clear faults and still have correct voltages right? People are telling me it’s a floating neutral and my voltages are all going to be off and I’m not clearing faults, etc.

    • @MikeHoltNEC
      @MikeHoltNEC  5 หลายเดือนก่อน

      Yes, you are 100% correct. The secondary bonding established the zero reference and effective ground fault current path. Of course you knew that.

  • @arthurcage275
    @arthurcage275 ปีที่แล้ว

    Can u make a Playlist that is in order of videos to watch to understand theory

  • @asperbergers7136
    @asperbergers7136 5 หลายเดือนก่อน

    999th like Mike! Thanks for everything you do!

    • @MikeHoltNEC
      @MikeHoltNEC  5 หลายเดือนก่อน

      Aww, thank you for the compliment.

  • @bradyy2052
    @bradyy2052 3 หลายเดือนก่อน

    I watch this to fall asleep hopefully some of the knowledge stays in my head tho fr

    • @MikeHoltNEC
      @MikeHoltNEC  3 หลายเดือนก่อน

      Hopefully...

  • @jeremymcguire7069
    @jeremymcguire7069 3 ปีที่แล้ว

    The pace of this presentation is very fast. That challenges me to follow along and keeps my attention focused. Thank you, you're an excellent instructor.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว +1

      Yes it is, but the second and third time you'll notice that I'm going slower...

  • @belindasiason7357
    @belindasiason7357 3 ปีที่แล้ว

    God bless you mike

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      Thank you and the same to you and your family.

  • @flinfaraday1821
    @flinfaraday1821 ปีที่แล้ว

    3:45 The top labels in this graphic make no sense to me.
    480V/20 turns = 48V per turn??
    24V x 5 turns = 240V??
    How?

  • @MrBelal79
    @MrBelal79 2 ปีที่แล้ว

    Amazing video as always, also I bought your books, it's amazing.

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว +1

      Thank you and I'm honored to be part of your success story.

  • @kahlil4745
    @kahlil4745 ปีที่แล้ว

    The ruler thing is silly. It's a sine wave and that measurement is related to the area under the curve.

  • @robbullock3662
    @robbullock3662 2 ปีที่แล้ว

    I love your videos! That does look like a bong on your back shelf though

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      I did remove it for that reason.. lol.

  • @buckaroundandfindout
    @buckaroundandfindout 2 ปีที่แล้ว

    Much love mike.

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      Thank you, and the same to all.

    • @buckaroundandfindout
      @buckaroundandfindout 2 ปีที่แล้ว

      @@MikeHoltNEC wow you really replied. You are awesome and God is great.

  • @undaya
    @undaya ปีที่แล้ว

    The conduit is the ssbj

  • @danielgladstone1789
    @danielgladstone1789 3 ปีที่แล้ว +2

    Hey Mike, great video as always. One question though: Do you use any particular software to draw your diagrams? I like how they have clamp meters etc on lines that you want to display the current reading. Makes the diagram very easy to follow and I'd like to be able to produce diagrams like that for my work as well

  • @8yerbrain
    @8yerbrain 3 ปีที่แล้ว

    Thank you.

  • @frederickmartinburg7591
    @frederickmartinburg7591 3 ปีที่แล้ว +2

    Hello there Mike, I'm preparing for the master electrician test. Which testing material would you recommend?
    God bless

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว +1

      Call 352.360.2620, and follow the recommendations given. Ask for a MH discount.

    • @frederickmartinburg7591
      @frederickmartinburg7591 3 ปีที่แล้ว

      @@MikeHoltNEC amazing

  • @dwaynes965
    @dwaynes965 3 ปีที่แล้ว +3

    I use 208 single phase all the time. 2 hot leads and a ground. no neutral.

  • @gilbertraydalida7551
    @gilbertraydalida7551 ปีที่แล้ว

    the best :)

  • @ecospider5
    @ecospider5 3 ปีที่แล้ว

    At the 3 minute mark your slide is Transformer Turns Ratio. The bubble at the top says 240v. Shouldn’t that be 120v. So 24v per turn x 5 = 120v.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      Yep, sorry for the typo in the graphic.

  • @michaeljiron7038
    @michaeljiron7038 2 ปีที่แล้ว

    The question that was asked around the 30 minute mark... Does the SSBJ have to be bonded to the metallic raceway that connects the transformer to the first means of disconnect. Aka ground bushings. Does the answer change if it's flex or EMT?

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      Feeder/branch circuit bonding is only required per 250.97 for 277/480V circuits where there is a KO. Nothing else.

  • @brianharmeson3144
    @brianharmeson3144 3 ปีที่แล้ว

    I have a question concerning high leg identification. You stay in this video and in your diagram that the high leg must be orange. However, the code states the high leg can be identified by an orange outer covering "or another effective means". So, my question is, is the high leg actually required to be orange If you use another effective means to identify it? Thank you.

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      I can't find where I made that statement. The identification of the high-leg conductor must be in accordance with 110.15.

  • @ohmware2020
    @ohmware2020 2 ปีที่แล้ว

    hi make, please make a video about single phase 2 wire system, line to ground/neutral system

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      I'm confused, 2-wire is just that, 120V L-N

  • @tvblood3550
    @tvblood3550 3 ปีที่แล้ว

    So in a single phase system, one only wire makes the main circuit and then comes the neutral and earthing,it's like a game in wich to got shocked I just have to close a circle=circuit I get that it's all pretty clear in the figures you show, actually thanks to your drawings I can understand now the whole thing. But now, where does the big circuit ends?
    Because being a big circle means L1 must meet L2 in some point right? According to your first lesson( current always come back to the source), L1.should come back to the source using to paths (neutral wire or L2 wire) so where does L1 becomes L2? Is this meeting point a phisical place like a substation or something?

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      Watch th-cam.com/video/mpgAVE4UwFw/w-d-xo.html

  • @makecashnow6714
    @makecashnow6714 3 ปีที่แล้ว +1

    Hi mike

  • @soloado5084
    @soloado5084 2 ปีที่แล้ว

    Sir, I want you to clear this confusion in my mind raised after listening to your talks on grounding .
    Please , I know dis video is off it .
    Can one say that grounding/earthing only takes care of events created by lightening ?

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      Watch MikeHolt.com/Fundamentals and you'll understand what I'm saying.

  • @agussurachman5246
    @agussurachman5246 2 ปีที่แล้ว

    3:18 in left slide, 480V/20 should become 24V instead of 48V, shouldn't it?

    • @MikeHoltNEC
      @MikeHoltNEC  2 ปีที่แล้ว

      Yea.... crap... thanks. Sorry for the typo.

  • @rigobertoruiz6136
    @rigobertoruiz6136 3 ปีที่แล้ว

    Which videos are the first two we need to watch?

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      This is the summary, so only this one.

    • @shellypizzo6664
      @shellypizzo6664 3 ปีที่แล้ว

      Yes he mentions 2 previous videos that should be watched before this if he is going to fast. What are they?

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      @@shellypizzo6664 This was a series of 'live' video recordings. Only some of these are kept on TH-cam. Sorry.

  • @Jecoopster
    @Jecoopster 3 ปีที่แล้ว

    Who has the links to the first two videos?

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว +1

      There were all combined into this summary video.

  • @BossManGlizzy
    @BossManGlizzy 3 ปีที่แล้ว

    I need to card out any tips to begin studying so i can pass for the first time? I have not began studying

    • @JohnQPublic345
      @JohnQPublic345 3 ปีที่แล้ว

      Star reading through the NEC page by page

    • @BossManGlizzy
      @BossManGlizzy 3 ปีที่แล้ว

      Bill Lumburgh will that actually help

    • @JohnQPublic345
      @JohnQPublic345 3 ปีที่แล้ว

      I'm old school. When we wanted to learn, we worked for low wage or free....and at same time hit the books hard. Today, everyone thinks they can do anything by watching a handful of youtube videos

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      Call my office 352.360.2620 and get the proper training program.

  • @makecashnow6714
    @makecashnow6714 3 ปีที่แล้ว

    I am Michael holt too a master Electrician people mistake me for you but I am not in Florida lol

    • @MikeHoltNEC
      @MikeHoltNEC  3 ปีที่แล้ว

      I’m not sure if that is good or bad. God Bless you brother.

  • @nlee5034
    @nlee5034 8 หลายเดือนก่อน

    Ugh!! They (powers that be) REALLY need to think about what words to use, before using them…
    Trying to explain “Grounded v Grounding”, and then an “ungrounded system”, makes me give a “parent-like” answer, to their question:
    “How is an ungrounded system, one with no ground… when the Grounded wire, is the neutral?”
    Mr- “IDK… it’s just how it is. “

    • @stillthakoolest
      @stillthakoolest หลายเดือนก่อน

      An ungrounded system does NOT have a grounded or neutral conductor

  • @mikewendell4748
    @mikewendell4748 3 ปีที่แล้ว +1

    Thanks Mike