Lighting Circuits Switch wiring Wiring at the switch

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ม.ค. 2018
  • Hi .In this video explains the 3 systems of lighting circuits used in the UK . I concentrated on particular one where all cables are connected at the switch . It's much more convenient if you prefer to install spotlights instead of ceiling rose with bulb. Hope it helps with your home projects. Thanks for watching.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 83

  • @peterbradshawe1870
    @peterbradshawe1870 3 ปีที่แล้ว +2

    After watching so many videos, this is so clearly explained! Thanks a lot for sharing 👍

  • @DanstheEngineer
    @DanstheEngineer 6 ปีที่แล้ว +8

    I think it's important to wire an electrical circuit in a manner that is easy to maintain and access so when designing and installing this should be taken into account. There is no need to install junction boxes when not necessary so in domestic I would prefer to see the first method (loop in and out). Good clear explanation in this video.

  • @gertholtzhausen6926
    @gertholtzhausen6926 5 ปีที่แล้ว

    I am no electrician. But your explanation and video made something i thought was rocket science look simple and clear.

  • @PurpleWhirple
    @PurpleWhirple 4 ปีที่แล้ว +3

    Thank you very clear and useful explanation. I’m running cables for an electrician and wasn’t familiar with this method. Think I can put my ceiling up now!

  • @Crystalpham
    @Crystalpham 4 ปีที่แล้ว +3

    the only practical and helpful video I’ve seen so far! Thank you!

  • @dilligaf2386
    @dilligaf2386 5 ปีที่แล้ว +1

    Not many electrition explain them selfs properly but you do thanx. I'm running cable for spots, under cupboard lights and two ceiling rose lights all in the kitchen I like your way of connecting the power straight to the spots but because I'm doing cupboard lights and ceiling rose I got confused so I'm using junction boxes for spots and cupboard lights onto ring . Good video .

  • @peterwalton1502
    @peterwalton1502 6 ปีที่แล้ว +1

    Really enjoy your videos. You clearly and simply explain the task

  • @am2747
    @am2747 7 หลายเดือนก่อน

    Thanks for the perfectly simple explanation. Appreciate it.

  • @danielhammond4782
    @danielhammond4782 6 ปีที่แล้ว +6

    just watch this video and really like it as you were very clear with your explanations.

  • @NW0106
    @NW0106 6 ปีที่แล้ว +6

    A very well explained and helpful video, top work.

  • @MartinDoyle
    @MartinDoyle 6 ปีที่แล้ว +2

    Thank you. Your videos are well presented and very clear. Your diagrams are excellent too! I've learned a lot.

    • @how2d223
      @how2d223  6 ปีที่แล้ว +1

      Thanks Martin

  • @nordicafrican3993
    @nordicafrican3993 6 ปีที่แล้ว +1

    thank you now this is what i was looking for this has been very helpful

  • @thomasbyles3075
    @thomasbyles3075 5 ปีที่แล้ว +1

    Thanks for this video, REALLY helpful

  • @BenningtonBuilds
    @BenningtonBuilds 3 ปีที่แล้ว

    Spot on 👌🏼 easy to understand and well explained 👏

  • @davidmeagher4909
    @davidmeagher4909 6 ปีที่แล้ว

    Excellent, thank you. Very helpful👍

  • @17kempe
    @17kempe 4 ปีที่แล้ว

    Thank you! Your a great teacher. This helped me a lot.

    • @lifeshort
      @lifeshort 3 ปีที่แล้ว

      *You’re

  • @ariftanoli9768
    @ariftanoli9768 2 ปีที่แล้ว

    Thanks, you explain it brilliantly.

  • @arranzoe1795
    @arranzoe1795 4 ปีที่แล้ว +11

    Just loop the line conductors through the top of the switch instead of extra connections in the wago

  • @Chris-uu6dg
    @Chris-uu6dg 4 ปีที่แล้ว

    Fantastic thank you for your clear explanation.

  • @adriancarter825
    @adriancarter825 ปีที่แล้ว

    Great video , I need a light under stairs I can now come off switch in kitchen thank you .

  • @samadams9347
    @samadams9347 4 ปีที่แล้ว

    Good job mate, great video.

  • @semereahferom854
    @semereahferom854 4 ปีที่แล้ว

    wow i found this very helpful Thank you keep up

  • @tympt1
    @tympt1 3 ปีที่แล้ว

    Thank you, very informative

  • @alexdyer2124
    @alexdyer2124 4 ปีที่แล้ว

    Brilliant. Very grateful

  • @azhariqbal1212
    @azhariqbal1212 3 ปีที่แล้ว

    Thank you sir excellent explanation.

  • @AkashPatel-uy6xb
    @AkashPatel-uy6xb 3 ปีที่แล้ว

    Excellent explanation 👌 👏 👍 😀

  • @rezamaddah2010
    @rezamaddah2010 3 ปีที่แล้ว

    Good man .useful video .clear .thank you.

  • @kuti101
    @kuti101 2 ปีที่แล้ว

    Thanks for explanation 👍

  • @WatchingTheo
    @WatchingTheo 6 ปีที่แล้ว +11

    Could you do a video on wiring an LED strip to a lighting circuit and switch please?

  • @aliahawkeswood1237
    @aliahawkeswood1237 6 ปีที่แล้ว +3

    Hi. I am using the switch connecting system, as I want to install a number of downlights. This is straightforward with the exception that I want to incorporate two way switching using 3 core and earth. Where previously I would intend wiring the brown wire from the power in cable to the Common, in the video the black wire from the 3C&E is wired to Common. Can you please describe the correct wiring in this situation. Thanks

  • @Michael-xk9ft
    @Michael-xk9ft 3 ปีที่แล้ว

    Thank you very useful.

  • @fahedzahran
    @fahedzahran 5 ปีที่แล้ว

    super clear

  • @Maggie-nv7ds
    @Maggie-nv7ds 4 ปีที่แล้ว

    Thank you very much .......

  • @shyamalsen3738
    @shyamalsen3738 4 ปีที่แล้ว

    very very nice Thanks sir

  • @Andrew-ki5jz
    @Andrew-ki5jz 3 ปีที่แล้ว

    Very interesting thanks

  • @viswanathaniyer2372
    @viswanathaniyer2372 6 ปีที่แล้ว +1

    A good viedeo

  • @westwonic
    @westwonic 4 ปีที่แล้ว +3

    Note that the three vertical cables to each switch must be chased into the wall. Thus rewiring with this switch loop method requires more work as most traditional UK properties have conduit in the wall that permits only one or max two cables.

  • @jaesedin
    @jaesedin 4 ปีที่แล้ว +1

    If I want to use two way or even 3 way switches, how is that achieved using the last, switch connection method?

  • @rajnirvan3336
    @rajnirvan3336 4 ปีที่แล้ว

    Wago connectors seem alot better than conventional blocks. In some way this 3rd method of light switch wiring is easier than loop in and junction box

  • @thomasotarimo5080
    @thomasotarimo5080 6 ปีที่แล้ว

    good

  • @nicolasvoro_nik1981
    @nicolasvoro_nik1981 5 ปีที่แล้ว

    👍👍👍👍

  • @paulneary703
    @paulneary703 3 ปีที่แล้ว

    What about if you need to install an extractor fan or smoke alarms of the lighting circuit? There won’t be permanent live at the pendants

  • @daringdarius
    @daringdarius 3 ปีที่แล้ว

    This is awesome!! Just want I needed to start working on my house. Thank you so much.

    • @grantmp5365
      @grantmp5365 2 ปีที่แล้ว

      How do u wire it at the light bulbs

    • @daringdarius
      @daringdarius 2 ปีที่แล้ว

      @@grantmp5365 Your light fixture should have 3 wires. Black, white, and bare copper.
      Attach black to black (Hot / live wire), Attach white to white (Neutral wire), and attach the copper wire (ground wire) from the wall to the green grounding screw in the box, then attach the bare copper wire from the light fixture to the copper wire in the box.

  • @DerekHundik
    @DerekHundik 5 ปีที่แล้ว

    Fitting deeper back box got another reason. Its dimmer switching.

  • @nickmerkouriadis3463
    @nickmerkouriadis3463 ปีที่แล้ว

    In case you want to use one of the switches of switch connection method with a dual control switch ( hall light on staircase?)..what are you doing?

  • @Mad4plumbing-ltd
    @Mad4plumbing-ltd 3 ปีที่แล้ว

    👍

  • @svenwhothehell5980
    @svenwhothehell5980 2 ปีที่แล้ว

    Hi, old vid but just come across it, hopefully you can advise? In my garage I have a consumer unit and out of the bottom of the consumer unit there is a cable direct to the light switch. Then out of the top of the consumer unit there is a cable direct to light... I want to extend for a new light and switch but not sure what I do with this arrangement I have?

  • @patrickjacobsen7805
    @patrickjacobsen7805 ปีที่แล้ว

    Am I the only person that is questioning this. Is the switch connection essentially wired in series because if the first switch is not working than the others upstream from it doesn't work too because only the first one is connected to the feed.

  • @Neil264Hoskins
    @Neil264Hoskins ปีที่แล้ว

    So to fit a shaver socket in a bathroom, I no longer have to go crawling around in the loft?

  • @Chris-uu6dg
    @Chris-uu6dg 4 ปีที่แล้ว +2

    Hi, Thanks for your great tutorial.
    Could you please tell me how you would wire a 2 gang 2 way switch using this method?
    would you need to add a fourth cable ( 3 core) if so would they all fit into a 2 gang switch?
    Many thanks

    • @jaesedin
      @jaesedin 3 ปีที่แล้ว

      I’m in the same boat. Did you find out how to do this? Cheers

    • @grantmp5365
      @grantmp5365 2 ปีที่แล้ว

      @@jaesedin did u find out

  • @yechihast
    @yechihast 4 ปีที่แล้ว

    Q: How many power feeds can be taken from a switch? Thanks in advance.

  • @stevenhorsfall8550
    @stevenhorsfall8550 5 หลายเดือนก่อน

    Do you have a video showing junction box connections please?

  • @plakumerre8514
    @plakumerre8514 4 ปีที่แล้ว

    Bravooooooo

  • @grantmp5365
    @grantmp5365 2 ปีที่แล้ว

    How do u wire it up at the light pendants

  • @AbdusSalam-gy4kd
    @AbdusSalam-gy4kd 2 ปีที่แล้ว

    Hi mate, can I use this for dimmer switch and how?

  • @mxtchb5696
    @mxtchb5696 8 หลายเดือนก่อน

    I’m wiring from the switch for down lighters but need to turn up stairs light from down and up and down stairs how can I do this?

  • @VMX-pc2ye
    @VMX-pc2ye 2 ปีที่แล้ว

    hi why u not draw the neutral line from consumer unit a.k.a DB board

  • @sahiluddin9717
    @sahiluddin9717 ปีที่แล้ว

    What did you do with the earth

  • @dub3557
    @dub3557 4 ปีที่แล้ว

    And all this goes from only one circuit breaker? Cuz looks like it is...
    In that case its not the best connection since if the cb jumps the whole house will be without lights...

  • @ashleywolf5522
    @ashleywolf5522 4 ปีที่แล้ว

    Where do I get the neutral wire from if my wall switch was a smart switch which required both Live and Neutral wires?

  • @asifr8962
    @asifr8962 6 ปีที่แล้ว

    Great video, very well explained, but could you tell me why there is no neutral wire connected to the switch, only seen you connect live wire into switch and one out.

    • @how2d223
      @how2d223  6 ปีที่แล้ว +1

      HI Asif. the light to work needs neutral and live but switch disconnect only live conductor .There is no terminal for neutral at the switch

  • @shamsulislam4158
    @shamsulislam4158 5 ปีที่แล้ว +1

    Hi there Sir
    I have a question and am asking this questions to other viewers too who already watched the video. In the video shows the real wiring with a sticker shows that previous room, light & next room. My question is that does the previous room means the connection came from consumer unit???? Please answer this question. If anyone answer this question I will really appreciate it Thanks

    • @JayAP2024
      @JayAP2024 5 ปีที่แล้ว

      It can be either previous room or consumer unit, eg if the example in the video was the first switch, the label would have said "consumer unit" but in this case its coming from the previous room/switch.

    • @MrSeananners12345
      @MrSeananners12345 2 ปีที่แล้ว

      yes it is the consumer unit but could also be from the previous room

  • @MrSeananners12345
    @MrSeananners12345 2 ปีที่แล้ว

    Surely put the 2 lines into common and not in a waygo ?

  • @BigTopia
    @BigTopia 5 ปีที่แล้ว

    Just seen this video. I want to install a brand new simple downlight in the attic. I already have downlights all upstairs. How do I go about this with wago connectors?

  • @avishayraggoo4639
    @avishayraggoo4639 3 ปีที่แล้ว

    Now how to add one switch to light all four buld ..?

    • @grubbyfingaz5910
      @grubbyfingaz5910 3 ปีที่แล้ว

      The switch live will go to bulb along with neutal from wago at switch, you will then double out of terminals at bulb 1 to 2 and so on

  • @bobbybenjani1978
    @bobbybenjani1978 ปีที่แล้ว

    Not sure why didn’t you just connect both permanant lives into common?

  • @DerekHundik
    @DerekHundik 5 ปีที่แล้ว

    No need for junction boxes. Just go straight with the feed to the first switch and then loop it to another and so on.

  • @RhamzAbdurajik-np3bd
    @RhamzAbdurajik-np3bd ปีที่แล้ว

    A

  • @DerekHundik
    @DerekHundik 5 ปีที่แล้ว +3

    MK rubbish. Why not connect your 2 live wires direct to the switch ? Its a lot of room. No need for wagos and extra piece of cable.

  • @BillyBullshitter
    @BillyBullshitter 3 ปีที่แล้ว

    Do you have to turn the power off when working with electricity.? Or can you wear special rubber shoes.?

  • @jamesfleming2683
    @jamesfleming2683 5 ปีที่แล้ว

    Again - just part of the information required to do the job correctly. What next DIY brain surgery?? SO much info missing, stop encouraging people to do what might kill them - most house fires are from dodgy diy electrics.
    This work must only be done by a Part P registered, qualified electrician. It's the law!!!