R422D, The R22 Replacement

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.ย. 2024
  • R422D is quickly becoming a popular substitute for R22. R422D does not require changing out the oil! To learn more about R422D visit our landing page at stores.johnston... and click on July's News "U" Can Use.

ความคิดเห็น • 33

  • @psychostix1313
    @psychostix1313 11 ปีที่แล้ว +2

    I have seen other videos for R422D but they never clarified if it needed to be charged in liquid form only for being a 400 series refrigerant. Thanks for clearing this up!!

  • @menendezgilbert
    @menendezgilbert 8 ปีที่แล้ว +13

    Yea, so professional and proper. Nice and clean. I like to see him be so proper in his procedure in 95 degree temperature with 80% humidity, along with his phone ringing for bitching customers. Taking care of 10 other things in that same day. If new people getting in to this line of work think that this is how it really is in the real world. Huh, there going to get a full eye opener.

  • @jdub7771
    @jdub7771 11 ปีที่แล้ว +2

    That's the sexiest recovery cylinder I've ever seen!

  • @kmreedN205
    @kmreedN205 6 ปีที่แล้ว

    Excellent textbook procedure. Refreshed my skills

  • @waltercastro2015
    @waltercastro2015 13 วันที่ผ่านมา

    I would suggest find R22 refrigerant online. Buy it, yes it is expensive but not too expensive as to replace the entire system.
    Whatever remains keep it for future usage and until you ac breaks. Then you have no choice.

  • @dallas69
    @dallas69 4 ปีที่แล้ว

    No
    Converting a R22 system to R422D
    1) I read 95% polyolester oil (POE) and 5% mineral (old R22 oil) is OK.
    2) POE oil is hygroscopic that means the oil should be pumped in and the oil can should not be opened to the air.
    But great work this is almost unknown by local Hvac companies here in DFW Thank You
    As a Hvac engineer
    Open compressor via removing the valve stem.
    Insert a rubber tube down to the bottom of the compressor
    Suck out 95% the old R22 mineral oil.
    Pump in new POE oil
    Re install valve stem.
    Purge with dry N2.
    Vac the system
    Charge with R422D.
    Pulling the compressor is not necessary.
    POE is a better oil for your HVAC system. If your going to change out R22 then it is better to suck out 95 to 100% of the old R22 mineral oil and start fresh with POE.

    • @Tim_Takacs
      @Tim_Takacs 4 ปีที่แล้ว +1

      Why do it when you can use this refrigerant or RS44b which is also a direct drop in?

    • @ryanmalin
      @ryanmalin ปีที่แล้ว

      I've got many rack systems and air conditioners running with r422d and mineral oil and so far no issues. Retrofit was carried out in 2016 and its been 6 yrs with mineral oil.

  • @myviews469
    @myviews469 10 ปีที่แล้ว +1


    I don't have a heat pump I live in NYS but I do have a small leak which requires me to add Freon every spring or summer. Question is there a clog up liquid I can use?

  • @butchtwoseven8890
    @butchtwoseven8890 11 ปีที่แล้ว +4

    hold on a minute, well about 1 minute and 11 sec. He evacuated the system before removing the old refrigerant? then he is going to recover the old gas, johnStone better re-do this procedure...

    • @josephrostkowski8631
      @josephrostkowski8631 ปีที่แล้ว

      Good catch 😂this is an infomercial funded by epa lobbies 😮! Wait til we go back to propane base refrigerants 😮 HISTORY HAS A STRANGE WAY OF REPEATING ITSELF 😮MAYBE WILLIS HAD IT RIGHT TO BEGIN WITH?

  • @jerryharvell3938
    @jerryharvell3938 4 ปีที่แล้ว +1

    Hello people I have several questions about converting a R22 system to any other new refrig type.
    Q1. Must I have the compresser replaced in order to convert the system? Been told this must be done I have. 3.5 ton goodman scroll compresser condensing unit. The compresser was replaced 2 years ago.
    Q2. Must the line set be replaced as well?
    Q3. My goodman air handler says R22/R410 compatible. 3.5 ton as well
    Q4. How much approx should I expect to pay for this service?
    Thanks

  • @LubaLuba1
    @LubaLuba1 3 ปีที่แล้ว

    Question to the smart professional man if I leave my AC running while evaporator is frozen will I lose Freon / R22??

  • @Vinces618
    @Vinces618 8 ปีที่แล้ว +1

    ALSO IF YOU HAVE A LEAK IN YOU SYSTEM YOU HAVE TO FILL EVERY YEAR IT IS BETTER TO FIND THE LEAK IT ISNT HARD SHOULD BE OIL RESIDUE WHERE HAS BEEN LEAK CLEAN AND PATCH IT,, BUT YES THEY DO HAVE STUFF THAT CAN SEAL LEAKS,, I WOULDNT PUT ANYTHING IN SYSTEM BUT THE REFRIGERANT BUT THEY SAY IS SAFE

    • @VinierrhinoGaming
      @VinierrhinoGaming 5 ปีที่แล้ว

      OK THANKS FOR YELLING AT ME I NEEDED THAT OK THANKS BYE HAVE A NICE DAY

  • @cecilburgess241
    @cecilburgess241 2 ปีที่แล้ว

    Do you know of anyone that does this in Sun City Az area?

  • @ThreePhaseHigh
    @ThreePhaseHigh 7 ปีที่แล้ว +3

    Reclaim the R 22 pull a good vacuum use the pressure temperature chart for the new refrigerant and get down the road. Time a wasting.

    • @craigpurdom1727
      @craigpurdom1727 5 ปีที่แล้ว

      ThreePhaseHigh with you on that one

  • @voncobain
    @voncobain 11 ปีที่แล้ว +1

    those are some old school micron gauge!

  • @aaronclark1599
    @aaronclark1599 ปีที่แล้ว

    Does it require an oil change

  • @trackforcemg5779
    @trackforcemg5779 7 ปีที่แล้ว +2

    Can you put in the nu 22b without pulling out the old r22??

    • @geoffhoweth
      @geoffhoweth 6 ปีที่แล้ว +3

      Has it been done Yes.... But EPA regulations forbid mixing of any types of refrigerants.

  • @Vinces618
    @Vinces618 8 ปีที่แล้ว

    ANY BLEND YOU SHOULD CHARGE AS lIQUID,, I USUALLY CHARGE LIQUID WITH EVERYTHING, DEPNDING HOW MUCH IS NEEDED IF PUTTING IN R22 OR A NON BLEND OF COURSE YOU SHOULD CHARGE VAPOR , BUT IF NEED TO DUMP IN ALOT CHARGE LIQUID, JUST DO A LITTLE AT TIME DO NOT FLOOD COMPRESSOR F COURSE

  • @newstart49
    @newstart49 11 ปีที่แล้ว

    R422d is a low to med temp refrigerant. Isn't residential classified as high temp?

  • @12345678972041
    @12345678972041 3 ปีที่แล้ว

    Are there any tax incentives for taking an old (but working) R22 unit out of service and replacing it with a new one (R410)?