VFD and Blower

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ต.ค. 2024
  • A 1/8HP VFD runs a 3 phase 230V 1/20HP motor. The VFD is powered by single phase, 120V input, and outputs 230V 3 phase. The wiring to the motor is temporary until I get proper cables.
    More specs of VFD:
    Name: GE Fuji Electric
    Model: AF-300 mini series
    Frequency range: 0-400Hz
    Carrier frequency range: 750Hz to 15kHz
    Rated current: 0.7A (output)
    V/Hz mode only (scaler torque)
    More specs of Blower:
    Name: Dayton Blowers
    Model: 3HMJ5
    Voltage range: (208-230V)
    current: 0.45/0.35A
    RPM: 1410/1630
    Airflow: 257.6cfm at 60Hz
    Ignore the mess in the background.

ความคิดเห็น • 5

  • @JS106351
    @JS106351  12 ปีที่แล้ว

    Nothing else is really needed to connect to the vfd; the only thing else I had to do was program it (which for the most part it was already preset out of the box). I could connect an external potentiometer and switch but those were already included in the vfd.

  • @kuzzinvinnie
    @kuzzinvinnie 12 ปีที่แล้ว

    what signals other than 120v to the vfd and 230v from the vfd to the blower are needed?

  • @lincolncontinental
    @lincolncontinental 9 ปีที่แล้ว

    Where did you get that blower from, what's the model?

    • @JS106351
      @JS106351  9 ปีที่แล้ว

      Lincoln Continental Hello, the blower that I used was a Dayton model # 3HMJ5. I bought the blower used on eBay for around $40.