How I Regulate My New Seiko’s (Easier than you think!)

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ธ.ค. 2024

ความคิดเห็น • 43

  • @dunderhay9169
    @dunderhay9169 2 วันที่ผ่านมา +11

    You made it look easy 😁👍. I think a warning of just how bad an idea it is to touch the hairspring would have been a good idea.

  • @JonTheComputerDoctor
    @JonTheComputerDoctor 2 วันที่ผ่านมา +9

    Training as a Watch repairer I tend to regulate them to plus 8 to plus 12 seconda a day so on the wrist they run near enough bang on, off the wrist they gain around 5 to 10 seconds fast over a 24 hour period.
    Those are my findings after doing approx 60 movements this year, some NH movements can be worse depending on how well put together.
    The Cronos I have on the wrist at the moment keeps near enough Quartz time.

    • @BAF605
      @BAF605 2 วันที่ผ่านมา +4

      I agree. I always wear the watch first to see how it behaves in use then I regulate according to those results. Some watches can look great on the timegrapher but be out quite a lot in use.

    • @watchalot919
      @watchalot919 20 ชั่วโมงที่ผ่านมา

      Depends on the movement, but I agree +8 on an N H calibre is about right

  • @Hrethgir
    @Hrethgir วันที่ผ่านมา +1

    Adjusting both can be so frustrating, but when you get it just right, feels so good! I've adjusted a few NH movements to be just as good as a Rolex. I need a timegrapher though, I've been using an app on my phone and earbuds with a microphone. It works, but so fiddly.

  • @waris3732
    @waris3732 2 วันที่ผ่านมา +12

    Gary you've made it look so easy. To all the folks out there, it's not that easy. I tried regulating a movement, the pick slipped and went into the balance spring and completely fudged the movement. It would no longer work anymore
    So advice;
    Hack the movement then adjust any lever.
    Use a wooden pick

    • @stevenrobertson6656
      @stevenrobertson6656 2 วันที่ผ่านมา +1

      Did exactly the same twice. Great advice about hacking the movement.

    • @stig585
      @stig585 2 วันที่ผ่านมา

      I used the springbar tool which was metal. Why is that not ideal?

    • @stevenrobertson6656
      @stevenrobertson6656 2 วันที่ผ่านมา +1

      @@stig585 It can magnetize the movement .

    • @charleshowarth8461
      @charleshowarth8461 วันที่ผ่านมา

      Here's advice. Don't buy a seiko. The only watch that is mentioned to regulate in you tube

    • @chriskelly509
      @chriskelly509 วันที่ผ่านมา +1

      I ruined a movement once lol, ended up just replacing the nh35 with a new one lol. I'll try the hacking tip next time.

  • @HollyGrosvenor
    @HollyGrosvenor 15 ชั่วโมงที่ผ่านมา

    Thanks for your video Gary just ordered a timegrapher hope it's as easy as described in your video.

  • @gordonewan144
    @gordonewan144 2 วันที่ผ่านมา

    Great to see this being done, it’s not something I’ve been brave enough to try yet. I think a timegrapher might have to be added to my Christmas list!

  • @twitchyjambo
    @twitchyjambo 2 วันที่ผ่านมา

    This is a great video Gary, never seen this done before and having never seen before I've never wanted to try, nice one😃👍

  • @shanephillips8735
    @shanephillips8735 2 วันที่ผ่านมา

    Great video, thank you Gary 😎

  • @khronokraze
    @khronokraze 2 วันที่ผ่านมา +4

    I pretty much do the same thing.
    One thing very important while adjusting both lever A & B. DO NOT TOUCH THE STUDS ON THEM. Those brass looking "bolts" things on each lever arm. Too technical to explain. But, they are super sensitive and can totally throw off your readings and near impossible to recover unless you know exactly how to readjust them.

    • @stig585
      @stig585 2 วันที่ผ่านมา

      Why cant we use the stud to adjust it if we have a timegrapher? Also can the timegrapher app (watch accuracy meter) on android be trusted?

    • @khronokraze
      @khronokraze 2 วันที่ผ่านมา +1

      @stig585 just don't push on the stud as it will throw off the readings. Use the lever only. Go ahead and try the stud if you want to learn the hard way why not

    • @stig585
      @stig585 2 วันที่ผ่านมา

      @@khronokraze can you please elaborate why not? I have already done so and i guess my bit error went from 0.2 to 0.6. Not sure if i caused any irreversible damage

    • @Sicarius888
      @Sicarius888 2 วันที่ผ่านมา

      Do you mean if I touch this yellow thing it can get loose, wiggle in the fitting when arm moves and because of that change regulation randomly on its own?
      I usually touch the yellow thing, seems easier not to touch the spring that way. And I noticed 2 watches started to have inconsistent daily average, like+5 one day and -4 the other while wearing more or less the same way. But I thought it was just random bad luck of mass produced nh35.

    • @khronokraze
      @khronokraze 2 วันที่ผ่านมา +2

      Slight correction on words and terms I used in my initial comment(s).
      There is a stud arm which controls the beat error and regulator arm which controls the rate. What I should have said about those yellow brass components in either is that they should be called pins. They twist and turn to help adjust and control the regulation. But, they are very sensitive and require a special tool to turn them and you really need a very good macro lens to view the pin from underneath to see how the pin is adjusting for a spacing around the spring.
      Too technical for me to explain thoroughly.
      I would suggest looking at videos regarding etachron regulation or adjustment. Seeing what it does and how tricky it is to work with may better illustrate why you don't want to mess with it unless u have the proper tools to correct if accidentally moved.

  • @wastedaga1n
    @wastedaga1n 2 วันที่ผ่านมา +1

    Great video!

  • @medicenquillos
    @medicenquillos 2 วันที่ผ่านมา

    Nice video like always, Mr Gary. I think that you just forgot mentioning a breve explanation about lift angle so we can expect an accurate amplitude on the movement health. Thank you and regards!

  • @AlexanderB.
    @AlexanderB. 2 วันที่ผ่านมา +2

    Excellent job! But I would suggest to use a wooden toothpick (that's what use) or a plastic stick instead of a metal screwdriver, you know: magnetism

    • @eoon
      @eoon 2 วันที่ผ่านมา

      In my first adjustment attempts I used toothpicks and ended up with wood particles finding their way between the dial and the crystal. From that point on I use a metal tool which main purpose is pushing out push pins from bracelets.
      One thing I recommend doing is making sure you’re not looking at your work area from the top but rather from a “parallel” position. This way you have the depth and distance in check (as much as you can with how tiny those things are) and you’re less likely to miss the adjustement leavers and stick the watch right in its beating heart.

  • @julianb1474
    @julianb1474 2 วันที่ผ่านมา

    good job!

  • @zynetik
    @zynetik 2 วันที่ผ่านมา +1

    I have found that some movements like being on .1 or .2 beat error. it depends on the specimen and the movement model itself. also i like stting my watches between 0 and +4.
    you are supposed to time and adjust them 30 minutes after a full wound, to let the mainspring relax a little bit.

    • @boydjohnson7393
      @boydjohnson7393 วันที่ผ่านมา

      Can I please ask a question, Is it okay to adjust the movement whilst the mainspring is in motion.

  • @teeKeri
    @teeKeri 2 วันที่ผ่านมา

    Amazing ! ♥

  • @MaartenAnna
    @MaartenAnna 2 วันที่ผ่านมา

    Indeed! Job's a goodin'!
    I need to do this to a number of watches of mine.
    Q. Can you do a comparison between a phone app which does this and this timegrapher. I'm into watch modding, but reluctant to get a timegrapher, if I can just use an app.

  • @snoopyandnoopy
    @snoopyandnoopy 2 วันที่ผ่านมา +1

    How much do you torque the case back up when finished?

  • @watchalot919
    @watchalot919 20 ชั่วโมงที่ผ่านมา

    I can't tell you how many hours I have spent doing that. A Sellita just has a screw, and it takes seconds, what's more the beat error is always OK with that movement. NH movements are fine when the regulation is good, but you never know what your going to get

  • @Shri_V
    @Shri_V 2 วันที่ผ่านมา +1

    It's hard to remember which lever is for adjusting time and which for beat error. Any tips?

    • @ILikeWatches2
      @ILikeWatches2  2 วันที่ผ่านมา

      I just move one and see what changes

  • @johnrb9397
    @johnrb9397 วันที่ผ่านมา

    What if the amplitude is low Gary is this when you look to do a movement swap or service?

  • @Binns57
    @Binns57 2 วันที่ผ่านมา +3

    Lift angle is wrong. Should be 53deg.

  • @chrisgreenwood271
    @chrisgreenwood271 วันที่ผ่านมา

    before you get to deep into trying to regulate a movement, check it ain't magnetised first.

  • @Walnutman5700
    @Walnutman5700 2 วันที่ผ่านมา

    Why doesnt it come from the manufacturer that way?

  • @finesse49
    @finesse49 วันที่ผ่านมา +3

    In your title you put an apostrophe in Seikos. There's no apostrophe in a plural.

  • @G1966TK
    @G1966TK 2 วันที่ผ่านมา

    One should not have to do this on a new watch,

  • @helloxuxu
    @helloxuxu วันที่ผ่านมา

    Abuse of the apostrophe in the title.