    @nwmi493 2 ปีที่แล้ว

    i appreciate the thorough communication as to what you u see, why its bad, what is right .. and why etc.. .. he was a blue wire nut man til the day he died lol

    • @GainSolarPower
      @GainSolarPower  2 ปีที่แล้ว

      The blue wire nut song needs to get finished

  • @fisherus
    @fisherus 4 ปีที่แล้ว

    Really like the way you do things. The right way! I was taught as a young kid that if it is good enough to do, then it should always be done the right way first as it will not only save you money but, a lot of grief in the future. Solar, however, has been challenging for me as I didn't have a good grasp on electrical diagrams or how everything else works. So, it is always a new learning experience. I put disconnect switches on my panel ground mounts and additional disconnect switches outside the PV entry to my Sol-Ark 12k as well as disconnect switches from my battery bank system. In addition to fuses I feel that you can't have too many ways to cut power off if any emergency arises. Keep up with your great videos!

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว

      Thanks Craig. Yes I agree if it is worth doing its worth doing right. The Solark is a great inverter. I’m doing one at my house. Just make sure everything is good and tight/torqued. Sounds like you have lots of connections. If they are loose they can heat up. I have a thermal imaging flir phone attachment that I check stuff with some time

  • @brianjacobs4949
    @brianjacobs4949 3 ปีที่แล้ว +1

    Thank you for your videos . Can you share where you get your bypass box from and which model?

  • @marktheunitedstatescitezen185
    @marktheunitedstatescitezen185 3 ปีที่แล้ว

    Thank-you ! I have a 5KVA 230v Pure Sine Wave 48v & I have 15 Pcs 3.2v 280A for 48v in series it’s still 280A , I have the Moes Automatic Transfer Switch to a 100A Double Pole Breaker & I have a brand New Siemens BreakerBox and to charge the Batteries I have 3 Car Alternators 2 Gm 1 wire High Amp 100 ~ 120A and a Ford Masada 150A the alternator creates Ac Current , I have 3 - 12v Dc motors to spin the alternators but my issue is my PV input on inverter input has to be 48v to charge battery bank & to use the electrical “ Thank you “ I know less than some who knows anything ! But I’m trying to keep my family safe when the grid goes down like with this Ida storm !

  • @danieldougan8550
    @danieldougan8550 4 ปีที่แล้ว +2

    Aren't you always supposed to disconnect solar first?

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว +1

      Yes if there is a disconnect. Didn’t want to do it at the equipment for fear of a spark which would burn the terminal, possibly damage the equipment

  • @LBSolar
    @LBSolar 3 ปีที่แล้ว

    Good video! Can I get some grits with that solaar? :)

  • @centraltesting426
    @centraltesting426 4 ปีที่แล้ว

    Ouch, that's an accident waiting to happen. No disconnects on anything, I'm amazed that nothing got popped when it was originally installed.

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว

      There is definitely some sub par work out there. I enjoy fixing the botched installs

  • @SolarDrew
    @SolarDrew 3 ปีที่แล้ว

    Say, since you have a disconnect in the solark why didn’t you put the doc disconnect at the panels instead of on the other side of the wall the inverter is on

  • @toobglued
    @toobglued 2 ปีที่แล้ว

    Even if this guy didnt know anything, id still hire and pay him double. He js Funny as fook

  • @ernestcriss
    @ernestcriss 3 ปีที่แล้ว

    Do you happen to have used magnum inverters for sale. I would prefer a 48v split phase if possible.

  • @rvfix2211
    @rvfix2211 ปีที่แล้ว

    Your comment about the power grid sending power for miles is not the same as the solar panels. Solar panels are DC current .. not AC current which was developed for traveling long distances.

  • @andys5203
    @andys5203 ปีที่แล้ว

    Awesome video. Can you tell me if the solark has a zero export feature. I'm trying not to get involved in net metering. Thks

    • @GainSolarPower
      @GainSolarPower  ปีที่แล้ว

      Yes feel free to email me
      Jv@gainsolarpower.com
      They call it limited power to home in the manual but it is zero export
      They use CT’s to achieve this feature

  • @late4dinner268
    @late4dinner268 4 ปีที่แล้ว

    Great video again

  • @SuperVstech
    @SuperVstech 4 ปีที่แล้ว

    What are they doing with the old setup? Ebay?

  • @sterlingmoses1044
    @sterlingmoses1044 4 ปีที่แล้ว

    What insulated gloves do you prefer? Can't remember which video it was in but I tried catching the name on the gloves, saw something flex.

  • @amirthompson1900
    @amirthompson1900 4 ปีที่แล้ว

    Good vid. You said he oversized his feeders? I'm not a solar guy but 10awg is rated @ 35 amps(@75°C)so he's gotta use #8 to feed a 40 amp load right?

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว +2

      I knew someone would catch that. He oversized the feed to the magnum. It only needs 10/3. He could have used 10awg

  • @obdnanrsmith8572
    @obdnanrsmith8572 3 ปีที่แล้ว

    100kv / 200kv / 500kv is what runs on the power lines, don't quote me on the first two. It's a mega butt load though.

  • @offgridwanabe
    @offgridwanabe 4 ปีที่แล้ว

    By the look of the shade on those panels you need some tree removal too

  • @raptormatt21
    @raptormatt21 4 ปีที่แล้ว

    Not a disconnect to be seen! Yikes.

  • @madtec3348
    @madtec3348 2 ปีที่แล้ว

    770 I ?

  • @SuperVstech
    @SuperVstech 4 ปีที่แล้ว

    I'm an unlimited electrician in NC, and wow... so many improper and dangerous decisions here...

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว

      Examples?

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว

      We were just lifting the connections hot for dramatic effect, and because I didn’t wanna spark the equipment, but there was no load.

    • @SuperVstech
      @SuperVstech 4 ปีที่แล้ว

      @@GainSolarPower examples? I think you covered them... i was meaning the old install... you did fine work.

    • @GainSolarPower
      @GainSolarPower  4 ปีที่แล้ว

      SuperVstech thanks. Always nice to have a second eye on it

  • @madtec3348
    @madtec3348 2 ปีที่แล้ว

    but I no tec !!! MMMMMM..