SYIL X4 CNC Mill, Teknic Clearpath SDSK, Centroid Acorn Project: Back Panel Wired & Tested

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 มี.ค. 2021
  • Back panel is wired. I go over start up pre checks, power it up, configure CNC12 and turn the Clearpath SDSK motors again.
    Stay Up to date by following my build thread on the Centroid User's Forum:
    centroidcncforum.com/viewtopi...
    Clearpath SD Overview: • ClearPath-SD (Step and...
    Clearpath SD Fractional Accessories: • ClearPath SD Servo Fra...
    Clearpath Integrated Servo Motor Video discusses SDSK and SDHP along with demonstrating stalling a stepper motor (open loop) vs. "trying" to stall an SD Motor: • Watch a ClearPath Inte...
    Centroid Acorn: www.centroidcnc.com/centroid_...
    CNC4PC.com C86ACCP: www.cnc4pc.com/c86accp-clearp...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 63

  • @derekrussell9925
    @derekrussell9925 8 หลายเดือนก่อน +1

    Just came across your channel! Very excited to see the content you focus on! Thank you for your work! God bless you
    I subscribed as soon as I saw all your videos 😊

  • @thomasmistretta3309
    @thomasmistretta3309 3 ปีที่แล้ว +4

    If I could give two thumbs up I would

  • @wickedprotos1937
    @wickedprotos1937 3 ปีที่แล้ว +1

    Look great Marty!!! So neat!!!!

  • @jlchapman4
    @jlchapman4 3 ปีที่แล้ว +2

    Hi Marty! Thanks for taking the time to create the video series. Great information and just in time for my build. Couple of questions, What do you use for bringing the power into the panel? Disconnect switch? Thanks, Jerry

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว

      ABB on/off switch. I will feature it in the next video. You should go visit my build page on the Centroid forum so you can get a link to my Google album to see random pics. centroidcncforum.com/viewtopic.php?f=60&t=5389

  • @polaraligned1
    @polaraligned1 3 ปีที่แล้ว +2

    Amazing how compact it can be with the drives being in the motors.

    • @SuperYellowsubmarin
      @SuperYellowsubmarin 3 ปีที่แล้ว +1

      Yes, that's why I love my Clearpaths. Only downside, only one feedback line :(

    • @polaraligned1
      @polaraligned1 3 ปีที่แล้ว

      @@SuperYellowsubmarin Not sure I understand what you mean about "only one feedback line".

    • @talonosi
      @talonosi 3 ปีที่แล้ว

      @@polaraligned1 I assume that he means there is only a single output from the clearpath motors that indicate motor state, the HLFB output. No encoder output, nothing that provides more k formative motor state information without jumping to a USB cable and the MSP software.

    • @SuperYellowsubmarin
      @SuperYellowsubmarin 3 ปีที่แล้ว +1

      @@polaraligned1 feedback line (HLFB as Technik names it) is the only output of the SDSK version of Clearpath servos. You can assign only one of several possibities (on position, fault, encoder index, ...). Sadly on CNC you absolutely need the fault output, so you cannot use other fonctions at the same time like encoder index for accurate homing, like you would on DMM.

    • @polaraligned1
      @polaraligned1 3 ปีที่แล้ว

      @@SuperYellowsubmarin I see what you meant now. Yeah, that does stink.

  • @oswaldomoraleslopez
    @oswaldomoraleslopez 3 ปีที่แล้ว +1

    Un gran video.

  • @jamesmaccubbin7434
    @jamesmaccubbin7434 3 ปีที่แล้ว

    Marty - thank you again for these videos.Tthe way you have it set up here, you only have one 220v coming in, and are powering both the spindle/VFD and the IPC-5 power supplies for the Teknic from that one power cable. I assume that means that the IPC-5 can handle 220v, and the Meanwell power supplies can as well. Is that correct? I love the simplicity of having one cable in and not a seperate 110v cable. I didn't realize that was possible until this video. Thank you!

    • @MartyEscarcega
      @MartyEscarcega 3 ปีที่แล้ว

      Yes, as I explain in the series, by removing a jumper on the IPC-5 power cable it accepts 220vac as do the power supplies in the cabinet

  • @bostondan77
    @bostondan77 2 ปีที่แล้ว +1

    Is there a polarity to the Snubber? how do you have it connected to the contactor? thanks Marty for everything that you do.

  • @hamiltonpianos
    @hamiltonpianos 3 ปีที่แล้ว +1

    As the series continues, I'm feeling more and more out of my depth...! :( That said, I had the same feeling building my first CNC using Arduino and UGS, and that turned out fine. Very close to ordering my Acorn, so looking forward to the next exciting instalment of the SYL X4 Mill series! :)

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว +2

      You have a basic understanding of CNC control, some basic Electrical/Electronics experience, and when you get stuck, the Centroid CNC Users forum is there to help

    • @hamiltonpianos
      @hamiltonpianos 3 ปีที่แล้ว +1

      martyscncgarage Thanks Marty👍😊

  • @tstanley01
    @tstanley01 2 ปีที่แล้ว

    You said you wired your E stop inline with relay 1 and input 8. Is the reason you ran it in series with relay 1 (no fault) is incase acorn freezes up and doesn't respond and you need to physically disconnect the contactor? I just wired mine to input 8 and it seems to be working fine, but I should probably change it if that is the reason you did it that way. It makes sense to have a physical disconnect.

  • @andrewnash48
    @andrewnash48 ปีที่แล้ว

    Hey Marty, I am just getting around to wiring my back panel. I have the C86ACCP and somewhere else you showed driving the NO_FAULT terminal on the C86 using OUT1 from the relay baord, but that is now driving the coil for the contactor. In the configuration shown here, what is being used to drive the No_FAULT to enable the C86 - it looks like there may be a couple of purple wire shown but I could not figure out what they went to.

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      You need a spare set of contacts on your contactor or fir another relay oof out 1

    • @andrewnash48
      @andrewnash48 ปีที่แล้ว +1

      @@martyscncgarage5275 thanks - I was tending toward setting up another relay, but the extra set of contacts on the contactor is way more sensible

  • @andrewnash48
    @andrewnash48 3 ปีที่แล้ว +1

    Thanks for the content Marty. The Centroid wiring diagrams for the C86ACCP show an E-stop with a single NC connection - your setup looks more sophisticated. Are there downsides to the version shown in their schematic? I dont have the VFD that you are implementing was I am using the integrated version on the PM 728VT

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว +1

      I always suggest using an Estop contactor. That is the purpose for the second contact block.

    • @andrewnash48
      @andrewnash48 3 ปีที่แล้ว

      @@martyscncgarage5275 I am assuming that the contactors value is primarily for higher current applications? Or does it give you an extra estop option?

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว

      @@andrewnash48 a small machine can hurt you too. It's a personal decision. I try treat all my builds with the same safety measures.

    • @andrewnash48
      @andrewnash48 3 ปีที่แล้ว

      @@martyscncgarage5275 no argument - just trying to understand the extra value it brings (novice question)

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว +1

      @@andrewnash48 Safety. Pulls power from drives and disables the spindle

  • @StevenCookFX
    @StevenCookFX 2 ปีที่แล้ว

    Where did you get those power supply components? Your not using the regular supply that comes with the Acorn

    • @martyscncgarage5275
      @martyscncgarage5275  2 ปีที่แล้ว

      Meanwell Din rail mounted power supplies. Same as Centroid supplied power supplies, just din rail mounted. Search Amazon

  • @tstanley01
    @tstanley01 3 ปีที่แล้ว

    Random questions as I cannot find a manual for the power4 module (I am sure its my fault), but what molex connector is used to connect the 24v logic power?

    • @martyscncgarage5275
      @martyscncgarage5275  3 ปีที่แล้ว

      www.teknic.com/POWER4-HUB/
      Refer to connectors

    • @tstanley01
      @tstanley01 3 ปีที่แล้ว +1

      @@martyscncgarage5275 LOL...I was just on that page...I told you it was probably my fault. Thanks for your help...this series and been a big help to me getting mine setup!

  • @janvirbrar4181
    @janvirbrar4181 ปีที่แล้ว

    How did you connect the E-Stop switch, C86ACCP, and the contactor together? I cant quite clearly see your connections in the video. I've seen acorn e-stop schematic and c86accp schematic but I cant seem to figure out how to put them together.

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      Use another set of contacts on the Estop contactor to enable C86ACCP (going from memory, that was a LONG time ago and I have since sold that machine)

    • @janvirbrar4181
      @janvirbrar4181 ปีที่แล้ว

      @@martyscncgarage5275 Can you use a 120V contactor in the layout that you have? Or would that not work with Acorn's relay board

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      @@janvirbrar4181 I would not recommend it, but it would work. I'd suggest 24vdc

  • @rickraynock740
    @rickraynock740 11 หลายเดือนก่อน

    Hi Marty , Can you explain how and where the t suppressor plugs into and what brand it was and how to buy one

    • @martyscncgarage5275
      @martyscncgarage5275  11 หลายเดือนก่อน

      The quench arc? It goes across the coil on the Estop contactor. Centroid sells them.

    • @rickraynock740
      @rickraynock740 11 หลายเดือนก่อน

      @@martyscncgarage5275 thanks so Much Marty

  • @janvirbrar4181
    @janvirbrar4181 ปีที่แล้ว +2

    Hi Marty, do you mind explaining whats going on at the terminal blocks? I have never used them before but want to avoid using multiple outlets and have breakers like you have here.
    Are you using the yellow ones to get power from the meanwell and then supplying to power hub4?
    Also I am planning to build a router, would this arragement work?
    Lastly, how is the IPC5 being powered? I noticed in the beginning you said you had breakers for VFD and Control but I m not sure what you said about IPC5.

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      I no longer have that machine. What are you wanting to know? Terminal blocks are just a convenient way to land your wires. Suggest you follow a Centroid Acorn System schematic provided by Centroid on their Web site as a starting point

    • @janvirbrar4181
      @janvirbrar4181 ปีที่แล้ว +1

      @@martyscncgarage5275 I was wanting to know how you powered the IPC-5

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      @@janvirbrar4181 use an Estop contactor to provide the IPC-5 power. The estop button and the No fault relay output are in series with the Estop contactor coil. Meaning either one will open the contactor in case if a fault

    • @janvirbrar4181
      @janvirbrar4181 ปีที่แล้ว

      @@martyscncgarage5275 do you have a video that explains the e-stop contactor?

    • @martyscncgarage5275
      @martyscncgarage5275  ปีที่แล้ว

      @@janvirbrar4181 it is very clearly explained in the Centroid Acorn System schematic. Quite simply, it's job is to remove power from the drives and disable the spindle motor.

  • @laserfalcon
    @laserfalcon 7 หลายเดือนก่อน

    Marty
    What is VFD?

    • @martyscncgarage5275
      @martyscncgarage5275  7 หลายเดือนก่อน

      Variable Frequency Drive. Controls the speed of the spindle motor

  • @cornpop7805
    @cornpop7805 2 ปีที่แล้ว

    Pg 36 of ClearPath User Manual, Switching and fusing section (in regard to the IPC-5) says: "Switching the DC output side, especially with inexpensive relays, will ultimately result in poor performance (drop outs)
    due to pitting, corrosion and contact welding. If a power switch is
    required, install it such that the supply is disconnected from the AC input
    side."
    Obviously you're using a fairly substantial contactor, rather than just a cheap relay. But, their second sentence may not ONLY be in reference to the first sentence. In other words, there may be other reasons (than pitting your contacts) why you should switch the power from the AC side rather than the DC side. It sounds like a "shall" statement rather than a "should" statement.
    I've been in automation since 89' and I've never burnt up a component, which is a very rare claim. The reason is, I read and reread everything and I leave nothing to chance. This particular warning caught my eye because I've seen power supplies that will spike themselves to death if you disconnect the DC side. I was helping a company out who was smoking DC supplies, one after another. I put a high impedance meter on the DC and saw it go from say 24VDC to almost 100VDC, just as they removed the load (switched the DC off). 2 or 3 times and the supply gave up the ghost. I downloaded the manual and showed them where the mfg said only to switch the AC side. After the wiring change, they had no more issues. The IPC-5 may be completely different, but their statement reminded me of this interesting issue and I wanted to share.

    • @martyscncgarage5275
      @martyscncgarage5275  2 ปีที่แล้ว

      They prefer you to kill the AC. I changed it before I sold the machine

    • @cornpop7805
      @cornpop7805 2 ปีที่แล้ว +1

      Cool! I extensively rewrote my comment (very long) and posted it. I then saw your short and perfect reply. By the way, nice job on the system and the video. Thanks for all that you do!