Sir phli baat to me ye kehna chahunga aapko ki aapka jo samjane ka tarika he vo jabrdust he. Kisi ko bhi aasani se samaj me aa jayega. Aur aap bhut achhe se samjate ho. Aishe hi video banate rahiye.. mene aapka ek video dekha tabhi subscribe kr diya hu
Sir please ek video duct related full banao na Chiller ke bare me bhut padh liya Yah fir ahu ke bare me full fitting safety dampers iske bare me video bana do ?
Main dubai mein land mark suites hotel me chiller operate krta tha,wo alag system se thi,us me sirf chilled water tank hi tha,baki hote pipe same uske upar hi laga tha,same windo ac,30,floor ki building me sirf 4,unit thi,ak unite double compressor,4, unit me 8 compressor,wo bahot easy hai, Fark sirf itna hai,us me hote water sell nhi tha,fan laga tha
Air cooled condesor low tr ke liye hi use ho sakta h Water cooled high tr ke liye bcoz water ki specific heat jayada hoti h air se that's why it happens
Boa tarde mestre! Gostaria de tirar uma dúvida... Estou com um chiller York que ele não está obedecendo o set-point de capacidade. Já fiz às manutenção e ele continua com este sintoma. Causa; exemplo coloco a capacidade em 80% e após a rampa ele passa direto para 85% ou 90% e não desce mas. Fico grato pela ajuda
Sir your video have helped me a lot.I wana ask you that I am a diploma holder with only theorytical knowledge on chiller plant can I be selected as a chiller plant operator for abroad company .sir I request you to answer
50 % chance of celection if you have knowledge only therotical .. you should learn chiller oprating in any maintenance company in india around minimum 6 month.. after that you will try To go gulf ...
Sir mujhe bahot confuse hota hu child water supply and child water return me kahan kitna temperature rahta hai supply and leaving temperature diagram ke sath video bana kar pls samjhia
Ji agar apke saare chiller auto pe set hai to jaise hi temp. Up down hoga ya koi alarm ayega to doosra chiller automatically on ho jayega ..👉 lekin agar apka system Manuel hai to apko khud se on karna padega
Pump kha lagna hai sir discharged mai ya suction mai? primary pump red wala !pani upper kaise jayega? Kya upper pump hota hai? A.H.U aur cooling tower ke pass?
dost ... 2 pump use hote hai first primery pump and secondary pump primery ka kaam ahu ke outlet se water leke chiller ke inlet me deta hai . 👉 aor secondry pump ka kaam chiller ke outlet se water leke ahu ke inlet me water deta hai ... kabhi agar interview me pooche to aap yahi batana dost 👍 par kahi kahi pe keval primery pump se hi kaam ho jata hai lekin uske liye hame pump ki capecity duble karni hoti hai ...
ye jo aap vido dekhe hai isme .. condenser ki shall me gas hai aor tube me water hai ....isi tarah evaporater me ..tube me water hai and shall me gas hai .......👉 ek vidio maine aor upload kiya hua hai ..jisme shall and tube me kya hai kaise jaane ..is topic pe hai... description me link hai aap dekh sakte hai Sukriya
dost ...chiller line me water ek hi baar me poora bhar diya jata hai phir wahi water circulation karta rahta hai 👉.aor use bharne ke lie make pump use kiya jata hai ......jab kabhi chiller line water pressure kam hota hai ..to wapas se make pump water ko fill kar deta hai.....👉 make up pump ki vidio upload kiya hua hai description me link hai aap dekh sakte hai 👍
Ji isme capeliri nahi hoti ... Capliri keval refrigerator yani ki freez me lagai jati hai... Chiller me automatic expention valve ya orifes use kiya jata hai
usme paani lane ke liye ...make up pump laga hota hai ...jaise hi evaporater ka water pressor kam hota hai ...waise hi automatically make up pump water fill kar deta hai evaporater line me ...👉 make up pump ki vidio upload kiya hua hai description me link hai aap dekh sakte
3 typ ke hote HAi chiller ⭐ 1.water cooled chiller 2. Air cooled chiller 3. Vapor Absorption chiller Air cooled Chiller 10 Ton se 200 ton tak aate hai water cooled chiller 200 se 5000 ton tak Aate hai air cooled Chiller And water cooled Chiller hi jyada use kiye jaate hai all WORLD me ....vapor Absorption chiller bahoot hi kam use kiya jata hai 👍... aor koi doubt ho to pooch lena ⭐👍
Sir, ek baat samjh me nahi aaaaraha ki, agar -26°c refrigerant vapour ban jata hya to refrigerant ko compress kore k heat kahe kiya jata hya, tob to vapour ban k udd jaye ga . Is k upor ek vedio banaiye
Dost .... Jo gas evaporator se hoke compressor me jati hai use ham suction line kahte hai .. 👉Aor Jo gas compressor se hoke condenser me jati hai use ham Discharge line kahte hai 👍
Dost ...chiller ki gas pahle water ko thanda Karti hai ..aor phir wo thanda ( cool ) water ahu me jaata hai ahu me blower ( fan ) Lage hote hai jab fan chalta hai to hawa ko cooling coil ke Ander se kheechta hai jisse ki hawa bilkul thandi ho jati hai aor is hawa ko ham duct ke sahare jaha hame cooling deni Hoti hai office ya hall ham in jagaho pe hawa ko pahucha dete hai ..aor waha pe cooling pahuch jaati hai 👍
sir ek sawal h mere man me please bataye iske bare me ki jab compressor se refrigerant 44 'C se discharge hokar condenser me jati h and condenser ka minimum temp 23-25 tak rakhte h and refrigerant ka boiling point to -26 'C h to phir ye vapour se liquid kaise ban jata h qki positive temp to aur gas me hi banaye rakhega na bai boiling temp se ham yahi samjhte h ki -26 'C se agar positive me temp hoga to aur vapour me hi banaye rakhega please clear this doubt
Ji ... qki ye fluded evaporater hai Shell and tube typ me 2 typ ke evaporater hote hai .. 1. Fluded typ evaporater 2. DX typ evaporater .. 👉Fluded typ me tube me water and shell me gas hoti hai 👉Dx typ me shell me water and tube me gas hoti hai
jab evaporater me water pressure kam hota hai to ...use fill up karne ke liye ek chota sa pump hota hai ...jise ham make up water pump kahte hai ...wo pressure kam hone pe ...fresh water fill kar deta hai ... evaporater line me ....👉 make up water pump ka vidio upload kiya hua hai description me link hai aap dekh lijiye .... Sukriya
1. Low pressure 2. High pressure 3. low oil pressure 4. flow switch loss 5. surge 6. high current 7. anti freeze aor bhi alarm aate hai lekin ye main alarm hai jo shefty me bhi bola jata hai
Smajana tarika mast he vaisahab
sukriya ji 🤗
Thanx sir
Sir aap bahut acha samjhate ho thanx sir
Ji sukriya apka
Nice video sir..
Or aapke samjhane ka tarika bahut accha hai or hum sab aasani se samajh jate hai Thank you ...
Bahoot sukriya ji apka 💐💐🙏🙏
Very nice. Sir. Ji. Bhot ache se banate h. Aap
Thank you 👍
Bhut Acchi se explain krte ho aap. Sab samjh aagya
Bahoot sukriya ji apka 💐💐
Bohot badhiya! Thank you so much sir ❤❤❤
🙏🙏
Sir apke video ek number banatai hoo
Ji bahoot sukriya 🤗
Nice video each and every concept clear sir
Sukriya apka 💐🙏
Sir ji aapne ek baar me he samjha diya muje to thank you so much guru ji love you ❤️❤️❤️
Ji sukriya apka 💐🙏
So much thanks dear sir for make your every video am continue watching your video and I can understand very easily in your normal language god bless u
Ok sir
I am Electrical engineer but by watching this channels video I became Hvac engineer.
everything depends your intrest my dear 👍
Very nice video sir
God bless u
bahoot sukriya ji apka 🤗
Masha Allah well explanation 👌👌👌
bahoot sukriya ji apka 🤗
Ok sir very helpful video❤❤
Very nice explanation ❤️
Well explained..thanx
Kamaal hai boss thanks for your help
Bahoot sukriya ji 💐
Very very helpful video
Very good information 👌👍
Bahoot sukriya ji apka
Sir please ek baar contact kr lijiye Sir please 🙏🏻
Good Bhai
Aap kaha sa ho..? Help ful video.
Nice explanation sir
Ji bahoot sukriya ...apka 🙏
Nice video sir ji
Aur aap sirf,10,floor cooling ke liye itna bada system bata rhe hai, achanak se video mili to dekh liya, but very nice explain about chillers 👍
Ji Ye 10 floor 3 lack square feet ka area hai .. aor heat load around 1200 tr ka hai
Sir phli baat to me ye kehna chahunga aapko ki aapka jo samjane ka tarika he vo jabrdust he. Kisi ko bhi aasani se samaj me aa jayega. Aur aap bhut achhe se samjate ho. Aishe hi video banate rahiye.. mene aapka ek video dekha tabhi subscribe kr diya hu
Ji bahoot sukriya apka ... 🤗👍
Excellent . pls make more videos on compressors and other utilitirs
ok jii 👍
You are Super sir ❤. Kuch TH-cam pai galat banake dale hai, jo hum logo ko sikhna galat ho jati hai
koi baat nahi ....apko jaha bhi koi question ho ya doubt ho to ap kabhi pooch sakte hai 👍
@@c4chiller9984 thank you sir.. Your my good teacher.. interview dene wala hunhu .. Aapki video sab dekh kai sir. 🙏🙏🙏
superb bro kch log btate hue darte h k isku na pta chal jaye
🤣🤣🤣
Very Nice Bro.
thank you 👍
Very nyc
3rd viewer. Nice video
Very thankful ,💐💐🙏
Bahut hi help full video sir ji bahut kuchh sikhne ko milta h apke videos se apse contact krna h
good explain sir tx
Good
Sir wairing to bataeye jaise fire dempar aur actuator moter aur kitna hp ke moter rahega to kitna lod lega kitne mm ka wire rahega
Sir chiller ke compressor ko change Karne Ka full process..ispe ek video please.
Ok ji
Great much obliged 😮
👍👍
Sir please ek video duct related full banao na
Chiller ke bare me bhut padh liya
Yah fir ahu ke bare me full fitting safety dampers iske bare me video bana do
?
Great sir crystal clear
Thank you
Plz make more videos on air compresdors
Wah ustad Kamal k hai aap
thank you 🤗
Main dubai mein land mark suites hotel me chiller operate krta tha,wo alag system se thi,us me sirf chilled water tank hi tha,baki hote pipe same uske upar hi laga tha,same windo ac,30,floor ki building me sirf 4,unit thi,ak unite double compressor,4, unit me 8 compressor,wo bahot easy hai,
Fark sirf itna hai,us me hote water sell nhi tha,fan laga tha
Ji bilkul hoga lekin shayed apki building residential hogi ... Jaha pe room me cooling di ja rahi hogi
Very nice sir
HAv ka bar and ahu panil canes ka bar baut
Subcooling or superheating kyu nikalte hain / or kab nikalte hain
Thanku so much sir 🙏🙏🙏
Air cooled condesor low tr ke liye hi use ho sakta h
Water cooled high tr ke liye bcoz water ki specific heat jayada hoti h air se that's why it happens
Nice 👍
Veri nice video so thanks sir
thank you 👍
Very good
Awesome sir
Sukriya ji 💐💐
Thank you so much sir....
❤️❤️🌹🌹🌹❤️❤️
nice video
Ji sukriya apka
Nice video
my all problems solved in 1 video
Sir Trane water cooled ki operation video bnaiye please
👍👍
Sir chiller kis principle pe kaam karta hai.
muje district cooling plant ka bare jannahe.
Uski bare ap koi bhi paper me drawing korke ak video banaiyye. 🙏🙏🙏.
Sir ye ji last m bataya h chiller wather ahu k baare m chiller m wather kha se aara h
Thank You Sir
Boa tarde mestre!
Gostaria de tirar uma dúvida...
Estou com um chiller York que ele não está obedecendo o set-point de capacidade. Já fiz às manutenção e ele continua com este sintoma.
Causa; exemplo coloco a capacidade em 80% e após a rampa ele passa direto para 85% ou 90% e não desce mas. Fico grato pela ajuda
Sir apke jo centrifugal condenser or chilled water pump hain wo kitne Hp ya KW Watts ke hain
👌👌
Suction pressure or discharge pressure kya rhega R134a refrigerants ka
Suction pressure.. 35 to 45 psi
Discharge pressure.. 90 to 150 psi
Thank bro
Thank you so much
🤗👍
👍🤗
🤗👍
Sir chiller plant mein discharge line , liquid line aur suction line ka temperature range kitna hota hai ??
Thankyou shering
Sir your video have helped me a lot.I wana ask you that I am a diploma holder with only theorytical knowledge on chiller plant can I be selected as a chiller plant operator for abroad company .sir I request you to answer
50 % chance of celection
if you have knowledge only therotical .. you should learn chiller oprating in any maintenance company in india around minimum 6 month.. after that you will try To go gulf ...
Thanks sir
👍👍
Refrigerant ka cycle thoda sahi se batao
Kaha par he sir aap
Sir mujhe bahot confuse hota hu child water supply and child water return me kahan kitna temperature rahta hai supply and leaving temperature diagram ke sath video bana kar pls samjhia
dost ...aap agar instagram use karte ho to aap yaha aa jao mai apka doubts bilkul clear kar deta hu ...ye I'd hai meri 👉 kgufran195
Okh sir
Bhai ager jo chiller start hai usme kuch alaram aa gaya to dosara chiller auto start ho jata hai. Ya manual start krna padta hai
Ji agar apke saare chiller auto pe set hai to jaise hi temp. Up down hoga ya koi alarm ayega to doosra chiller automatically on ho jayega ..👉 lekin agar apka system Manuel hai to apko khud se on karna padega
HVAC CONTROL TECHNICIAN kya hota hai sir isme kaun kaam karna hota hai
HVAC TECHNICIAN se ye alag hota hai kya
Interview Dena hai Kuwait ke liye
Pump kha lagna hai sir discharged mai ya suction mai? primary pump red wala !pani upper kaise jayega? Kya upper pump hota hai? A.H.U aur cooling tower ke pass?
dost ... 2 pump use hote hai
first primery pump and secondary pump
primery ka kaam ahu ke outlet se water leke chiller ke inlet me deta hai .
👉 aor secondry pump ka kaam chiller ke outlet se water leke ahu ke inlet me water deta hai ... kabhi agar interview me pooche to aap yahi batana dost 👍
par kahi kahi pe keval primery pump se hi kaam ho jata hai lekin uske liye hame pump ki capecity duble karni hoti hai ...
Condenser pump bhi do hote hai na?
dost .
condenser pump 1 hota hai high capacity ka ...
Hlo sir actuator valve kya kaam karta hii
water ko required ke hisab se aage bhejta hai
AOA sir
Sir avapretor ke sal and condenser ke sal both side same conditions
ye jo aap vido dekhe hai isme .. condenser ki shall me gas hai aor tube me water hai ....isi tarah evaporater me ..tube me water hai and shall me gas hai .......👉 ek vidio maine aor upload kiya hua hai ..jisme shall and tube me kya hai kaise jaane ..is topic pe hai... description me link hai aap dekh sakte hai Sukriya
Chillar me total 4 cycle ka use hota h kiya??
Cooling tower se building TK Air ko le jane me
Condanser m to cooling tower se lekin chiller m jo chl ra h wo kha se supplier h
dost ...chiller line me water ek hi baar me poora bhar diya jata hai phir wahi water circulation karta rahta hai 👉.aor use bharne ke lie make pump use kiya jata hai ......jab kabhi chiller line water pressure kam hota hai ..to wapas se make pump water ko fill kar deta hai.....👉 make up pump ki vidio upload kiya hua hai description me link hai aap dekh sakte hai 👍
Where is economiser used?
Haevy chiller .. 800 tr capecity crossed
Chillar me proper pressure kitna hota hai
dost ..konsi gas hai apke chiller me
gas pe pressure dekha jata hai ki ..konsi gas hai chiller me
🙏🙏🙏🙏🙏🙏
👍👍
Esame sir tharomostate aur caplary tube Kaha hoti
Ji isme capeliri nahi hoti ... Capliri keval refrigerator yani ki freez me lagai jati hai... Chiller me automatic expention valve ya orifes use kiya jata hai
Sir chiller me gas pump ka Kya kaam ho hai
Ji questions samjh me nahi aaya .. aap dobara bataiye ... Gas pump hai ya gas pumping
Gas pump jo evaprater ke niche laga hota hai
Evoprolatar me pani kaha se ata hai
usme paani lane ke liye ...make up pump laga hota hai ...jaise hi evaporater ka water pressor kam hota hai ...waise hi automatically make up pump water fill kar deta hai evaporater line me ...👉 make up pump ki vidio upload kiya hua hai description me link hai aap dekh sakte
Sir g chiller ktni qesm KY hoty hn or ktny ktny taan MN hoty hn
3 typ ke hote HAi chiller ⭐
1.water cooled chiller
2. Air cooled chiller
3. Vapor Absorption chiller
Air cooled Chiller 10 Ton se 200 ton tak aate hai
water cooled chiller 200 se 5000 ton tak Aate hai
air cooled Chiller And water cooled Chiller hi jyada use kiye jaate hai all WORLD me ....vapor Absorption chiller bahoot hi kam use kiya jata hai 👍... aor koi doubt ho to pooch lena ⭐👍
Sir, ek baat samjh me nahi aaaaraha ki, agar -26°c refrigerant vapour ban jata hya to refrigerant ko compress kore k heat kahe kiya jata hya, tob to vapour ban k udd jaye ga . Is k upor ek vedio banaiye
ok dost is topic pe bana doonga vidio 👍
@@c4chiller9984 thank u sir
Sr section discharge kya hota ha
Dost ....
Jo gas evaporator se hoke compressor me jati hai use ham suction line kahte hai ..
👉Aor Jo gas compressor se hoke condenser me jati hai use ham Discharge line kahte hai 👍
Sir cooling kese jaigi age
Dost ...chiller ki gas pahle water ko thanda Karti hai ..aor phir wo thanda ( cool ) water ahu me jaata hai ahu me blower ( fan ) Lage hote hai jab fan chalta hai to hawa ko cooling coil ke Ander se kheechta hai jisse ki hawa bilkul thandi ho jati hai aor is hawa ko ham duct ke sahare jaha hame cooling deni Hoti hai office ya hall ham in jagaho pe hawa ko pahucha dete hai ..aor waha pe cooling pahuch jaati hai 👍
Sir chiller ka Delta 5°C se jayada ho rha hai hai kya reason hai
Apka living kya ja raha hai ???
Sir ji fresher m jagha hai toh batayea
Dost ...Apke pass Kya hai iti ya diploma
sir ek sawal h mere man me please bataye iske bare me ki
jab compressor se refrigerant 44 'C se discharge hokar condenser me jati h and condenser ka minimum temp 23-25 tak rakhte h and refrigerant ka boiling point to -26 'C h to phir ye vapour se liquid kaise ban jata h qki positive temp to aur gas me hi banaye rakhega na bai
boiling temp se ham yahi samjhte h ki -26 'C se agar positive me temp hoga to aur vapour me hi banaye rakhega
please clear this doubt
Ji aap instagram pe ho to aa jaiye
Ye meri id hai 👉 kgufran195
sir mai Instagram use nhi karta hu but mai aaj bna lunga id
Ok ji .. jo bhi questions ho aap instagram pe pooch sakte hai .. 👍
Are sir evaporator me tube me gas kaha se aa gai bataiye sir
Ji ... qki ye fluded evaporater hai
Shell and tube typ me 2 typ ke evaporater hote hai ..
1. Fluded typ evaporater
2. DX typ evaporater ..
👉Fluded typ me tube me water and shell me gas hoti hai
👉Dx typ me shell me water and tube me gas hoti hai
Sir,evaporated mein water kaha se ataa hai. please bataye.
Make up pump se .. fresh water aata hai
Vidio maine banai hui hai make up pump ki link hai description me ap dekh sakte hai
Evaporator ko water kidharse ata hee
jab evaporater me water pressure kam hota hai to ...use fill up karne ke liye ek chota sa pump hota hai ...jise ham make up water pump kahte hai ...wo pressure kam hone pe ...fresh water fill kar deta hai ... evaporater line me ....👉 make up water pump ka vidio upload kiya hua hai description me link hai aap dekh lijiye .... Sukriya
@@c4chiller9984 thank you sir
Sir mujhe isme aane wale alarm k bare m janna h
1. Low pressure
2. High pressure
3. low oil pressure
4. flow switch loss
5. surge
6. high current
7. anti freeze
aor bhi alarm aate hai lekin ye main alarm hai jo shefty me bhi bola jata hai
High pressure alarm aane k reason low pressure k reason kya hoga