How to do Electrical Wiring properly! (more or less....) GERMAN STYLE!

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ก.ค. 2024
  • A Better 2021 for All JLC & GreatScott! friends: jlcpcb.com
    Previous video: • DIY Online Security Ca...
    How circuit breakers can save your life! video: • How circuit breakers c...
    Facebook: / greatscottlab
    Twitter: / greatscottlab
    Support me for more videos: www.patreon.com/GreatScott?ty=h
    You can get a proper Jokari and Wire stripper here (affiliate links):
    amzn.to/38vB4tq
    amzn.to/34DHDt0
    In this video me and my friend will show you how to do electrical wiring properly. That means we will remove the complete electrical system of his garage and install a new one. We will be talking about/showing you how to mount and wire up a new distribution box, install circuit breakers, mount electrical components like outlets, switches and lamps, install conduits, lay cable and finally how to connect all the components to one another. Let's get started!
    Websites which were shown in the video:
    de.wikipedia.org/wiki/Liste_d...)
    Thanks to JLCPCB for sponsoring this video.
    Visit jlcpcb.com to get professional PCBs for low prices.
    Music:
    2011 Lookalike by Bartlebeats
    Killing Time, Kevin MacLeod
    (incompetech.com)
    0:00 Introduction
    1:16 Intro
    1:47 Drawing an Installation plan
    2:42 Explaining the Flow sheet
    4:20 Ordering the components
    5:12 Practical Build
    11:01 Final Test & End
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 1.7K

  • @marcoschwanenberger3127
    @marcoschwanenberger3127 3 ปีที่แล้ว +610

    German here. Incase some people think "Meh, he probably did it extra well here in this video, there is no way this is how its done on site irl".
    Nope. That is exactly how. In any house where the electrical system was either renewed, or new anyways - this is exactly how it looks. :D

    • @volkhen0
      @volkhen0 3 ปีที่แล้ว +44

      Yep, but in most houses you don’t use “on the plaster” type but “inside plaster” type or whatever it’s called. In Poland we have special flat white cables that go into plaster without any conduits.

    • @iamjimgroth
      @iamjimgroth 3 ปีที่แล้ว +50

      Looks just like in Sweden. North Europe takes standards very seriously. :P

    • @fabianmayer
      @fabianmayer 3 ปีที่แล้ว +9

      Are you shure? Some stuff needs to be bodged, because some people think it is a good idea they do it yourself, and not like the good kind he did. You see the fuse at the beginning of the video? Some random dude had the brilliant idea to hammer a Nail into it since the fuse kept melting... long story short the fusebox started to burn.

    • @fabianmayer
      @fabianmayer 3 ปีที่แล้ว +18

      @@iamjimgroth yes there is like a whole book with all the regulations the NIN (Niederspannungs Installastons Normen) it hast 200 pages for the compact version.

    • @ladmad9196
      @ladmad9196 3 ปีที่แล้ว

      @@volkhen0 i think these arent up to norms anymotr

  • @RajendraBhattRajDa
    @RajendraBhattRajDa 3 ปีที่แล้ว +756

    Scott: Talks about wiring standards
    India: We don't do that here

    • @sayujraphael
      @sayujraphael 3 ปีที่แล้ว +83

      Who needs connecters We have insulation tape😂😂

    • @mahargha_debnath
      @mahargha_debnath 3 ปีที่แล้ว +50

      @@sayujraphael who needs insulation tapes we leave it open

    • @dragonslayerornstein387
      @dragonslayerornstein387 3 ปีที่แล้ว +32

      @@mahargha_debnath Why leave it open when you can hide twisted wires behind the cupboards!

    • @fidelcatsro6948
      @fidelcatsro6948 3 ปีที่แล้ว +6

      India using Chapati Standard plagiarized from the Ex Colonial British Standard

    • @AbhishekBana
      @AbhishekBana 3 ปีที่แล้ว +18

      Well. We do have a strict codes and standards in India. None of us follow when in comes to LT wiring for houses. We do follow a lot of codes for industrial HT wiring. But things are getting better slowly. :)

  • @elodgubcsi
    @elodgubcsi 3 ปีที่แล้ว +818

    Finally something not American! Thank you so much! Even though we have more or less the same system in Hungary, it's nice to see a detailed guide

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +69

      Glad you like it!

    • @alhdgysz
      @alhdgysz 3 ปีที่แล้ว +39

      Örültem, hogy nem karton papír házakat látok, és összecsavart vezetékeket 😂

    • @balazskoti2603
      @balazskoti2603 3 ปีที่แล้ว +36

      This is exactly how is done in Hungary with the exception of the "German trademark" precision measurements. We just eyeball it. :D

    • @alhdgysz
      @alhdgysz 3 ปีที่แล้ว +23

      @@balazskoti2603 it's a nightmare to drill the wall of a Soviet block of flats....

    • @brentmihills5186
      @brentmihills5186 3 ปีที่แล้ว

      Read me if you want

  • @dhupee
    @dhupee 3 ปีที่แล้ว +1043

    German standard makes here in indonesia looks like unga bunga

    • @alfineranai6952
      @alfineranai6952 3 ปีที่แล้ว +62

      people in developing country usually install their electrical wiring using uncertified engineer because of lack of certified engineer.

    • @dhupee
      @dhupee 3 ปีที่แล้ว +27

      @@alfineranai6952 tbf in my place, where almost every home is built well maybe in 2000s or before...and being built by non certified makes me have to finish what they've done like on insulating and other thing
      Old house didn't have breaker like new one and instead they have a fuse with screw connect like a bulb lamp
      Well, time to repair it each side of our houses one by one right

    • @putraadriansyah8082
      @putraadriansyah8082 3 ปีที่แล้ว +7

      Exactly. My home only have 2 unknown circuit breaker to separate half of my home. And 1 6A from PLN. I don't even have PE wiring properly installed. So whenever I want to power my sensitive stuff I usually just plug it in into my own DIY power grid in my room (actually just a DIY inverter to power my room with proper wiring and earth protection). Separated from home electrical which is powered by PLN.

    • @YandiBanyu
      @YandiBanyu 3 ปีที่แล้ว +22

      Jokes on you, I do the house wiring myself to make sure it is up to DIN.

    • @adityapradipta6209
      @adityapradipta6209 3 ปีที่แล้ว +10

      There are a lot of cases of house catch on fire because the use of thin wire for heavy loads such as microwaves, washing machines, refrigerators, etc due to budget cuts.

  • @sneaky3685
    @sneaky3685 3 ปีที่แล้ว +565

    A new installation and no "Erstprüfung" according to VDE 0100 Teil 600? Thats pretty mutig 😂

    • @deburu
      @deburu 3 ปีที่แล้ว +15

      As long as the FI/LS pops xD

    • @factionTaste
      @factionTaste 3 ปีที่แล้ว +36

      Das stimmt. Die deutsche nirm ist auch beim Verteiler nicht eingehalten zulleitung über ein 1,5mm² ist sehr fragwürdig

    • @Hessijames79
      @Hessijames79 3 ปีที่แล้ว +10

      @@deburu We don‘t know if it pops. The rcd values were not measured. And no, pressing the test button is not sufficient.

    • @power3516
      @power3516 3 ปีที่แล้ว +17

      @@factionTaste Nachdem die alte 6A Vorsicherung zwischen der Zuleitung und dem FI/LS glaube ich weiterhin vorhanden ist passt das in diesem Fall schon, da das 3x1,5 ja vorgesichert ist. Sollte die 6A Schraubsicherung nicht mehr verwendet worden sein würde das natürlich nicht gehen.

    • @nixda8901
      @nixda8901 3 ปีที่แล้ว +5

      @@power3516 War da nicht was mit Selektivität? Oder galt das nur für FI's?

  • @juststeve5542
    @juststeve5542 3 ปีที่แล้ว +182

    3:05 - Slight correction on the RCBO, it doesn't detect current flowing to the protective earth wire, it detects an imbalance of current flowing down the live and back on the neutral.
    If it only detected current flowing to the protective earth wire, you could get a shock, passing the current through your own body to ground, and not down the protective earth wire, it wouldn't detect it.

    • @justinc.8191
      @justinc.8191 3 ปีที่แล้ว +4

      Exactly what I thought hahaha

    • @mickn6619
      @mickn6619 3 ปีที่แล้ว +3

      This is the commentary I was looking for. 😊

    • @Lenny-kt2th
      @Lenny-kt2th ปีที่แล้ว +5

      That's actually a big correction. An RCD could work in an installation without any earthing. The imbalance between L and N is the criterium and doesn't need PE at all.

    • @IAmThe_RA
      @IAmThe_RA ปีที่แล้ว

      @@Lenny-kt2th He prolly thought an RCBO worked like an ELCB which detects current flowing through the PE.

    • @LarryKoopa
      @LarryKoopa ปีที่แล้ว

      @@Lenny-kt2th it will work without a PE but it doesnt work without any earthing. how could you be shocked with touching L without there being at least a connection on the producer side over earth to N. there are actually systems build like that in hospitals and such and they require over methods of keeping track of faults 👍

  • @m4gmu5hell
    @m4gmu5hell 3 ปีที่แล้ว +117

    How long has it been, since I saw such wiring.... In our company, the first things our apprentice learn is how to do house wiring properly, and we have a realy good picture on our pegboard, showing how wire connections should look like and how it shouldn't look like. I'm so glad, that they teach this to us, even though we usually work on PCBs.

    • @tfr
      @tfr 3 ปีที่แล้ว +10

      Time traveller!

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +9

      @@tfr Patreon time traveller ;-)

    • @kylehill3643
      @kylehill3643 3 ปีที่แล้ว

      @@greatscottlab ????

    • @red13emerald
      @red13emerald 3 ปีที่แล้ว +1

      @@kylehill3643 Videos are uploaded as private and Patreons get the link immediately while others have to wait a while to see new videos. This is one of the perks of being a Patreon subscriber.

  • @montemattia97
    @montemattia97 3 ปีที่แล้ว +275

    This was a PLEASURE to watch for someone working in this field! Thank you for the hard work you put in these videos

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +24

      Much appreciated!

    • @comback8237
      @comback8237 3 ปีที่แล้ว +1

      @@greatscottlab can you make a video about IC plz :)
      Cause I’m confused about the pins and what they do

    • @leonk7985
      @leonk7985 3 ปีที่แล้ว

      One yeare left till i work in this feald also I´m from Germany so this video was greate

    • @bagoston325
      @bagoston325 3 ปีที่แล้ว +1

      @@comback8237
      ICs are always different. If you want the specific pinout of an IC, the best thing you can do, is look at the numbers on it's top, input them into your preferred search engine, and look for either a site called alldatasheet, or just a plain pdf file.
      If you find the pdf of your specific IC, then after reading it, you'll find the pinout, and parameters as well.

    • @skillfailer
      @skillfailer 3 ปีที่แล้ว

      @@comback8237 In case you still need help, just comment here again, and Ill help ya.

  • @Darkshadow799
    @Darkshadow799 3 ปีที่แล้ว +268

    It's surprising how different German switches, cables and connectors are from the Italian ones. As always, great video!

    • @fb55255
      @fb55255 3 ปีที่แล้ว +35

      So true, noticed it expecially those wires with solid strand instead of multicore

    • @enricomontanari1390
      @enricomontanari1390 3 ปีที่แล้ว +29

      All components updated to the new legislation are very similar to those shown in the video, also because they must follow very stringent European regulations.

    • @volkhen0
      @volkhen0 3 ปีที่แล้ว +29

      In Poland everything seems very similar to German type.

    • @Darkshadow799
      @Darkshadow799 3 ปีที่แล้ว +1

      @@fb55255 right, I always see that kind of cables in foreign youtubers videos, but I have never seen them in the electrical systems I worked with. They seem really practical.

    • @Darkshadow799
      @Darkshadow799 3 ปีที่แล้ว +1

      @@enricomontanari1390 in what year the new rules came into effect? I bought a bunch of new switches and electrical components last year, but they're not really similar to the ones in the video. I'd love to use wago terminal instead of the classical screw connector, but I never found them in shops. They need more space, but cable management looks neater.

  • @stephenwalsh1149
    @stephenwalsh1149 3 ปีที่แล้ว +93

    I would recommend keeping your power outlets and lights on separate circuit breakers. You are more likely to trip your power outlet, at least this way your lights don't go out if you do.

    • @great__success
      @great__success 3 ปีที่แล้ว +8

      You are right, but he said that the main (old ceramic style) fuse was only 6 amp, so if anything would happen, it would still trip that for sure.......if he could replace the ceramic with some 6A slow C-type breaker and after that two faster breakers, it might work

    • @viktorpeev2825
      @viktorpeev2825 3 ปีที่แล้ว +3

      @@great__success It is so easy to replace the ceramic fuse..... Install 20A, draw 2.5mm2 to the RCBO, draw 1.5 to the outlets and another MCB 6A for the lights with even 1.0mm2.

    • @great__success
      @great__success 3 ปีที่แล้ว +6

      @@viktorpeev2825 In my knowledge 20A ceramic fuse has bigger physical dimension, so even if you want to break the rules you cant and you would have to replace the whole socket.....it makes sense, cause probably all the nearby garages are connected to common outside breaker that is accesible only to few people...and by installing higger than 6A fuse you risk tripping of this outside breaker that might not be accesible to you

    • @viktorpeev2825
      @viktorpeev2825 3 ปีที่แล้ว

      @@great__success I highly doubt, that if your feed cable is more than 2,5mm2, the fuse is less than 20A, since the meaning of the FUSE is to protect the cable, not the consumer ( outlet,lights etc.). Anyway, it is just confusing for me. Never seen such instalation here in Bulgaria ( have to say, that here, most of the fuses are still ceramic). Kind regards.

    • @legominimovieproductions
      @legominimovieproductions 3 ปีที่แล้ว

      At least for short circuits it wont work and isnt allowed by the VDE as in case of a short both breakers would trip

  • @JohnLee-bf2ux
    @JohnLee-bf2ux 3 ปีที่แล้ว +188

    The tag line “German Style” brought me back here :p

    • @mihkus
      @mihkus 3 ปีที่แล้ว +6

      German style but I facepalmed quite many times, overlappings mainly... It just makes no sense why are there so many useleless connections and the use of cable glands...Main problem is the "main fuse"
      Could've solved it with 1 switch and 1 breaker in the same cabinet. Other than that its close to ideal.
      I have it worse in my own home.😂

    • @MakenModify
      @MakenModify 3 ปีที่แล้ว +7

      @@mihkus Then it would not be "German Style" ;) Everything according to the applicable standards :D

    • @leonnastaly4814
      @leonnastaly4814 3 ปีที่แล้ว +5

      Fuse is as sentimental add on. My concern is single Earth-Leakage in the Distribution Board. Women plugged faulty charger in the wall socket (short circuit not earth fault) and all garage went dark?. We have separate C/Breakers for lights and sockets with correct kA ratings. It helps a lot. Still nice job done comparing with the old one. Just different standards but nice to know. Good video.

    • @mariom.9472
      @mariom.9472 3 ปีที่แล้ว

      It is not forbidden to do it so, in my opinion its made cost-effective.
      In my house ever room has a circuit for lighting and one for outlet. Outlets has RCD type A, except my Workshop, it has Type B

    • @TecSanento
      @TecSanento 3 ปีที่แล้ว

      @@leonnastaly4814 Then you would have a need three breaker, one common and two appliance breakers, because two breakers in pararel could lead to the distribution line over loading (12A + 12A not tripping each of those two, but exceeds limit on distribution line of 16A)

  • @TheSella23
    @TheSella23 3 ปีที่แล้ว +5

    In Catalonia we use 1.5mm copper wire for 10A instalation, 2.5mm copper wire for 16A for electrical socket plugs, with one RCBO for max 5 circuit brakers and a diferent breaker for ilumination circuit 10A and a 16A braker for electrical sockets.
    Great videos, I love your channel.

    • @jecceworks
      @jecceworks 3 ปีที่แล้ว +1

      In Finland we also have to use 10A fuse for 1.5mm² and 16A fuse for 2.5mm², both copper. In a VERY special case you can use 1.5mm2 with 16A fuse, IF the cable is less than 2m long.

    • @TheSella23
      @TheSella23 3 ปีที่แล้ว +1

      We have also a maximum 3% of voltage drop, if you exceed you have to use the next wire section. We also have a restriction of maximum current depending of the instalation system.
      But I think prety much similar in all European Comunity members.

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +1

      Thanks for the info!

  • @justahungarianguy
    @justahungarianguy 2 ปีที่แล้ว +3

    As an apprentice in Germany, this video has helped me a lot to have the basics! Vielen Dank! :)

  • @powerupminion
    @powerupminion 3 ปีที่แล้ว +26

    I'm a danish electrician and i have a small correction:
    5:24
    The theoretical rating of a 1,5mm^2 wire is a little over 16A, but in european standards a 1,5mm^2 wire should never be able to pull more than 13A because of factors like distance, wire bunles, tempatures and a few other thecnical factors like short circuit current (Ikmin and Ikmax (the Ikmax is not valid in this situation)). All of these factors limit current rating very much.
    Unfortunaly you have to dive DEEP into electrical math to see that influence.
    Great video anyway. I was intertained.
    (Yea i know the entire installation has a 6A fuse in front of it, so 16A will never be able to run there before that pops.)

    • @DasIllu
      @DasIllu ปีที่แล้ว +4

      Short term loads of >16A are permitted by code in germany. In essence you are to avoid voltage drops of more than 3% over the length of the cable because of heat dissipation (among other reasons).
      But usually electricians in germany would dimension a cable as 6A/mm² nominal on on a B-Type breaker.
      If you exceed 6A or have a deltaU > 3% you'd step up in cross section to 2.5mm² yet still keep the B-breaker.
      There are ofc exeptions to the rule. Different load types and load profiles over time might require different breaker characteristics and cable parameters.

    • @TheEulerID
      @TheEulerID ปีที่แล้ว +2

      In the UK a 16A or 20A radial circuit would definitely used at least 2.5 mm^2 cabling (for a very long run it might need to be larger gauge). The 1.5 mm^2 cabling in UK use is generally reserved for lighting circuits which will have a 6A breaker.

    • @benedykt123313
      @benedykt123313 ปีที่แล้ว +3

      @@TheEulerID Same in The Netherlands; each wall outlet is wired using 2.5mm2 wiring; only switched lamps are using 1.5mm2. In Dutch household 6A circuits are very rare, so even those are mostly wired using 2.5mm2.

    • @Flamechr
      @Flamechr ปีที่แล้ว +2

      ​@@TheEulerID2.5mm^2 for 16 amp in Denmark

  • @johnathanasiou9284
    @johnathanasiou9284 3 ปีที่แล้ว +1

    Beautiful & simple setup there GreatScott.
    Super well explained & love how you also hammer home the safety aspects & the proper way to do it setting a good example.
    Having read so many Australian electrical accident reports due to dodgy wiring practices, this video is like a breath of fresh air.
    God bless you sir, may you always be really well & safe & can't wait to see more content!

  • @NoZoDE
    @NoZoDE ปีที่แล้ว +1

    Nice to see it done properly. My grandpa built our house in the 60s/70s And had a friend of him do the wiring. Over the years I found out just how messy they did our house. Grüße aus Unterfranken

  • @alicangul2603
    @alicangul2603 3 ปีที่แล้ว +36

    You draw better electrical plans on paper than some engineers here who draw it on AutoCAD.

    • @fullblis4788
      @fullblis4788 2 ปีที่แล้ว +1

      absolutely 😄

    • @IIISpeeder
      @IIISpeeder ปีที่แล้ว

      The hand its better, faster and easier , especially for drafts blueprints.

    • @ConstantinosJkay
      @ConstantinosJkay ปีที่แล้ว

      yeah but did you notice that he rewrites every letter ? probably OCD

  • @xhotadi
    @xhotadi 3 ปีที่แล้ว +4

    I used to work in Germany Electricity and i really liked their system, I Miss Berlin , and great video...

  • @rabel1545
    @rabel1545 3 ปีที่แล้ว

    Wow you are so professional! Even the clamps for the wire tubes are exactly where they should be and everything is planned, measured and calculated. And here I am doing everything frei Schnautze

  • @SurgeryMedia
    @SurgeryMedia 3 ปีที่แล้ว +2

    Another amazing video with clear, consistently planned content. Man... These videos make me so ambitious to give extra attention to my studies as an electrician while working as programmer. I find electronics and electrics so much more exciting nowadays than what I currently do for a living. Keep it up, I love your channel. Greetings from Hungary!

    • @calysagora3615
      @calysagora3615 3 ปีที่แล้ว

      Study mechatronichs and have use for your programming skills in your electronics and electrics! Highly demanded skills in combination!

  • @TheShippo97
    @TheShippo97 3 ปีที่แล้ว +5

    Im an italian electrician, here in italy 1.5mm sq is for 10amp circuit, for 16 amp we use 2.5mm sq, also you can use some adapter for the tube to the junction box and you dont have any whire exposed and get a better look, thanks scoot see you next time!!

  • @diode30
    @diode30 3 ปีที่แล้ว +13

    Its always interesting to see how different the standards are between the US and other countries.

  • @minhazul007
    @minhazul007 3 ปีที่แล้ว

    Really learned many things! Following your channel for 3-4 years, really helped me a lot! Thanks man!

  • @benjung1331
    @benjung1331 3 ปีที่แล้ว +1

    Great Scott, I love your electronic vids. I didn't think a simple elecrical wiring in Germany was so complex! In North America the simple electrical drawings are easier to follow and installation are much simpler. Thanks for the videos.

  • @GoodWolf
    @GoodWolf 3 ปีที่แล้ว +47

    Personally I would invest little bit more money and buy 2 RCBOs , one for the outlets and one for the lights. Simply because when outlet breaker pops you don't loose the lights too. But anyway nice work !

    • @snajperSLO
      @snajperSLO 3 ปีที่แล้ว +5

      This is normally how they/you do it... One breaker for lights, one for outlets / per room. Where I live light circuits are on 10A breakers and outlets on 16A. And all that on one 30mA RCBO.
      Don't even know if we can have lights on 16A breakers let alone lights and sockets on the same breaker.

    • @obeser1996
      @obeser1996 3 ปีที่แล้ว +2

      @@snajperSLO same here in autria with the New ÖVE8101 Rules that is a must. And the Light breaker is a C6 because B6 and some LED Lichts arent working together well.

    • @GoodWolf
      @GoodWolf 3 ปีที่แล้ว +7

      @@snajperSLO It's same in my country like you say. Not sure if we can have both lights and sockets on the same circuit. But for sure I know for 16A breaker we must use 2,5mm wire and not like Scott 1,5mm. We use 1,5mm wire only for a 10A breaker (typically for a light ciruit), for sockets we use 2,5mm wire and 16A breaker.

    • @snajperSLO
      @snajperSLO 3 ปีที่แล้ว +2

      @@obeser1996 as for the C6 or B6, depends on how many LED drivers are on the same cirsuit... The drivers we use specify that in the manual (26 units (circuit breaker of type B) / 44 units (circuit breaker of type C)). We had no issue with B6 or B10 for modern LED drivers (brand name drivers)

    • @obeser1996
      @obeser1996 3 ปีที่แล้ว +2

      @@snajperSLO yes your right the problem here is that we cant decide what Lichts the cosumer will use. And time tell that they are always using the cheapest Chinese brand they can find. Some of them are so bad they will lightly illuminate even when live wire is cut off.

  • @coryballiet8260
    @coryballiet8260 3 ปีที่แล้ว +36

    I've done a fair amount of wiring in my house and friends houses in the US. I like the German standards A LOT better. No wire nuts, things are labeled, everything is 240V. Seems nice.

    • @simwil524
      @simwil524 3 ปีที่แล้ว +7

      Me as a german using only Wagoklemmen (those shown here) do not really like the concept of those wirenuts. Seems like the germans are by far more practical.

    • @hermannpaschulke1583
      @hermannpaschulke1583 3 ปีที่แล้ว +2

      Wire nuts look flimsy AF. Screw terminals are better imo

    • @wolternijmeijer4164
      @wolternijmeijer4164 3 ปีที่แล้ว +1

      The wago clamps are great but compared to the wire nuts the touching surface of the conductors is tiny, wire nuts are in that case actually safer

    • @eDoc2020
      @eDoc2020 3 ปีที่แล้ว +9

      The only thing I (an American) finds wrong with this German wiring is the conduit ending in the middle of the path. I much prefer the American way where the conduit is continuous from box to box so everything there is well-protected.

    • @Freestila
      @Freestila 3 ปีที่แล้ว +3

      @@eDoc2020 the cable itself is pretty stiff. Even using these conduit ducts is not always the case, often you use small nailed clamps every 20cm or so. If you have the conduits directly to the boxes you havent enough room, since the inlets of the boxes are only for one cAble each and spaced apart. So if you want more then one cable in the conduit you need some space.

  • @spokehedz
    @spokehedz 3 ปีที่แล้ว +2

    It is incredible seeing the different 'standard' wires of a house. It would be neat to see a "model" home that you could see all the 'wiring' you would have to do for each countries standards.

  • @luzderschluz5077
    @luzderschluz5077 3 ปีที่แล้ว +1

    Perfect timing! We are just redoing a basement room for my electronics workshop

  • @akhurash
    @akhurash 3 ปีที่แล้ว +118

    Great work. In the US, the wiring connections are very much different. It’s interesting to see how it’s done in other countries. I will be updating the lights in a rental property I have.

    • @volkhen0
      @volkhen0 3 ปีที่แล้ว +14

      I like the all metal conduits in US and the junction boxes. It all looks neat.

    • @RecBlackLP
      @RecBlackLP 3 ปีที่แล้ว +3

      @@volkhen0 do the all metal conduits need a connection to earth ? Or how does it work in the US ?

    • @volkhen0
      @volkhen0 3 ปีที่แล้ว +1

      @@RecBlackLP I don’t know,
      I’m from Poland. I said I just like the US conduits style.

    • @andrewwest3994
      @andrewwest3994 3 ปีที่แล้ว +17

      @@RecBlackLP all metal conduit (called EMT) must be properly grounded, yes. Also, unlike Germany, all wiring must be secured and not exposed.

    • @ChristophMarius
      @ChristophMarius 3 ปีที่แล้ว +6

      @@andrewwest3994where do you see exposed wiring?

  • @zusurs
    @zusurs 3 ปีที่แล้ว +10

    Thanks for the video! Here in Eastern Europe (post-Soviet countries) aluminium wiring was a common practice a mere 20 years ago, including in apartment buildings. Pain in the ass to fix.

    • @user-mc5mu1xl4w
      @user-mc5mu1xl4w 3 ปีที่แล้ว +1

      I feel your pain

    • @alhdgysz
      @alhdgysz 3 ปีที่แล้ว

      Oh yes. And drunken electricians....

    • @snajperSLO
      @snajperSLO 3 ปีที่แล้ว

      @@alhdgysz thats why you have wires running horizontal and vertical in the wall as a bonus you get few going diagonal :)

    • @alhdgysz
      @alhdgysz 3 ปีที่แล้ว +1

      @@snajperSLO and wavy 😂

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว

      same in the states too well from 40 yrs ago

  • @carlosshootsfilm2889
    @carlosshootsfilm2889 3 ปีที่แล้ว

    I love the wago connectors, they work so well and make it easy to upgrade in the future!

  • @mikemount4411
    @mikemount4411 3 ปีที่แล้ว +1

    Very interesting the difference between your standards and the ones we have in the USA. Very nice job! Thanks for sharing.

  • @alvimuka1853
    @alvimuka1853 3 ปีที่แล้ว +3

    Here in albania most standarts are the same with the german ones so it was really helpfull to me

  • @xsiner
    @xsiner 3 ปีที่แล้ว +3

    I like how clean it looks, a lot of wire installs here in the State are not so clean.

  • @sappersrus8003
    @sappersrus8003 3 ปีที่แล้ว

    Great to see and hear in English. About to rewire my garages and so far been searching German wiring in English. Understand most in german but for clarification in my own language is good. Thanks

  • @groggers
    @groggers 3 ปีที่แล้ว

    Oh my goodness, I haven't watched you in ages - a year or two at least. Was surprised to learn you now make appearences in your videos! Great one as always! I have some catching up to do :)

  • @MC-01
    @MC-01 3 ปีที่แล้ว +223

    It's really different compared the standards here in the Philippines.

    • @zeendaniels5809
      @zeendaniels5809 3 ปีที่แล้ว +11

      Probably yours is pretty much the same as we have here in Latin America 😂

    • @suleymanturan465
      @suleymanturan465 3 ปีที่แล้ว +79

      Wait, you guys have standards ?

    • @jamess1787
      @jamess1787 3 ปีที่แล้ว +62

      @@suleymanturan465 yeah, 1) get it working. 2) keep it affordable.

    • @mariom.9472
      @mariom.9472 3 ปีที่แล้ว +3

      If i am not mistaken, the Powergrid is based on the North American System?

    • @dj9choco
      @dj9choco 3 ปีที่แล้ว

      also here in mexico, the conduit is always green and you need to add omega type clamps to secure it, and use curves for each 90° or a box with connectors to seal the pipe

  • @Sorrentino_Gianni
    @Sorrentino_Gianni 3 ปีที่แล้ว +23

    7:24
    Me, an European that consume a lot of American diy/electronic channels, clearly confused because he knew wall plugs.

  • @arivonto
    @arivonto 3 ปีที่แล้ว

    Hey Scott, I'm happy to find your channel which reminds me of my Ausbildung time in Mannheim. I finished my school als Kommunikationselektroniker Fachrichtung Informationstechnik back in 1990 to 1994.

  • @mateuszksiazek4484
    @mateuszksiazek4484 3 ปีที่แล้ว +88

    3:00 ElectroBOOM flashbacks are beginning...

    • @jamess1787
      @jamess1787 3 ปีที่แล้ว +6

      And that's only half the voltage potential!

  • @Chrono404
    @Chrono404 3 ปีที่แล้ว +11

    Great video. I am an electrician in the U.S. and it's interesting to see what's similar and what's different. We wouldn't be allowed to route the wires through the conduits with out boxes at every junction. Looking forward to your next video!

    • @Electronics-Rocks
      @Electronics-Rocks 3 ปีที่แล้ว +6

      In the UK the conduit has to go end to end and connect to boxes with glands. So bends have to be fitted to keep the wire protected at all times or you have to bend the pipe with a tool!

    • @volkhen0
      @volkhen0 3 ปีที่แล้ว +9

      The conduits in the video are mainly for esthetics reasons. You can put wires on the wall using clips too.

    • @fabianmayer
      @fabianmayer 3 ปีที่แล้ว +1

      @@volkhen0 yes and with some even better wire, you can raut it almost anyware.

    • @zenddoor
      @zenddoor 3 ปีที่แล้ว +6

      These wires run in a flame/heat retardant shell. Most of the time they have an even thicker shell (the gray kind), and for outside they can have a stranded metal jacket in them. I think in the US you use just the separate wires in metal conduit right? We also use seperate wires a lot by the way, but then we run them through a closed system of pvc (fire retardant) conduit. We don't use metal conduit in N.W. Europe.

    • @fabianmayer
      @fabianmayer 3 ปีที่แล้ว +2

      @@zenddoor well we do, but it is more for Cable outside, ore for when you know the conduit is wonerable to bein abused by cars ore animals

  • @ch4meli0n89
    @ch4meli0n89 3 ปีที่แล้ว

    it's great fun, seeing most of the components I, as a picker, handle every day, being used and not just laying around in bulk. even funnier seeing the same brands! it makes me want to take a closer look at actual wiring and the work of an electrition. Maybe I can persuade my company into making that possible one day haha

  • @MasterTanu
    @MasterTanu 3 ปีที่แล้ว +1

    In Portugal we use the same type of equipment, the same type of connector, and even the color code of the wires is the same. However, in Portugal the division of circuits is mandatory, that is, a protective circuit breaker for lighting and another for plugs. Another difference is that in Portugal it is only allowed to use 1.5mm2 conductors for lighting or for equipment with a maximum power of 850W, the socket circuits are mandatory to be made to conductors at 2.5mm2. Good job, thanks for the great videos!

  • @theoneguy3972
    @theoneguy3972 3 ปีที่แล้ว +20

    6:30 hab die gleichen, sind gut

  • @strindevall
    @strindevall 3 ปีที่แล้ว +6

    I love Wagos so much. My house was built in the 50s and it has a bunch of the old screw cap type things everywhere. Every time I find one I replace it with a Wago and I swear I can feel the house smiling.

  • @Lengari
    @Lengari 3 ปีที่แล้ว

    Man, I thought finally a video where I can show my skills in the comments but that video is well done. Can't add anything to it other than great job.

  • @mihaelkubatka1410
    @mihaelkubatka1410 2 ปีที่แล้ว

    As I can see the old plugs and switch are TEP products. They were made in Croatia (ex Yugoslavia) in factory Tvornica Elektrotehničkih Proizvoda. It was nice to see this little detail since I am your flower since early days. Hi to all from 🇭🇷

  • @guilhermedi1
    @guilhermedi1 3 ปีที่แล้ว +28

    The standards are really different from Brazil, really nice to see other standards.

    • @vilmarmoccelin
      @vilmarmoccelin 3 ปีที่แล้ว

      It's weird to see how some rules determine the products available.

    • @gambiarraemcasa1729
      @gambiarraemcasa1729 3 ปีที่แล้ว

      Outro brasileiro!!!!!!

  • @MaxOoze
    @MaxOoze 3 ปีที่แล้ว +5

    in Australia 'proper' means you have to run the conduit all the way into junction boxes. looks nicer too

    • @_S13_
      @_S13_ 3 ปีที่แล้ว

      Thats what i consider proper too. A gap in between is just ugly and looks like an amateur tried to fit it. Also im pretty sure its safer to run the conduit into the junction box because it provides more protection for the cable. In the Netherlands i never see those gaps thankfully...

    • @83hjf
      @83hjf 3 ปีที่แล้ว

      same for Argentina. No way you will pass a (commercial) inspection with wires flapping around. We don't run conduit all the way though, we have "connectors" for conduit for nice finishing. Also we use the same outlets as Australia.

    • @MaxOoze
      @MaxOoze 3 ปีที่แล้ว

      @@83hjf connectors are good, can also buy the junction boxes with a conduit receptacle molded in to it. We also tend to wire with 7 strand flat TPS instead of the circular cable used in the video.

    • @TheStiepen
      @TheStiepen 3 ปีที่แล้ว

      @@_S13_ to my knowledge that is explicitly forbidden in Germany. I don't know the reasoning behind that though.

  • @alexsavastru8125
    @alexsavastru8125 11 หลายเดือนก่อน

    This is great work. Surely a breath lf fresh air in comparison to what I've seen during my life.

  • @janjaganjac4315
    @janjaganjac4315 3 ปีที่แล้ว

    I'm from country from where is TEP(Croatia) and I love their older models of switches and outlets. Great video!

  • @anujchandel1591
    @anujchandel1591 3 ปีที่แล้ว +7

    I always love your videos
    A video on automated garden would be nice.

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +5

      Coming soon!

    • @anujchandel1591
      @anujchandel1591 3 ปีที่แล้ว +2

      I hope that's the next video
      I'm waiting ☺☺

  • @mantasliut
    @mantasliut 3 ปีที่แล้ว +10

    WAGO makes it all so easy :)

  • @tonyross2947
    @tonyross2947 2 ปีที่แล้ว

    I love your videos; it's so good to listen to a fellow engineer.

  • @america0014
    @america0014 3 ปีที่แล้ว +2

    I love the wago wire connectors!

  • @soranuareane
    @soranuareane 3 ปีที่แล้ว +12

    "Professional electrician" with how neat that wiring job is, I would be surprised otherwise.

  • @xAvIThEmIxEr
    @xAvIThEmIxEr 3 ปีที่แล้ว +3

    Looks the same in Spain but in Spain I never saw this 5cm gap of the wires without the plastic tube protection, always all the way to the boxes and corners protected with corner shaped tubes

    • @fidelcatsro6948
      @fidelcatsro6948 3 ปีที่แล้ว

      5cm open gap probably to allow fireman to use an axe to chop the connections off in a fire perhaps..

  • @nvmyutube
    @nvmyutube 3 ปีที่แล้ว

    clean and neat, just satisfying to watch, thanks !

  • @techcube7291
    @techcube7291 3 ปีที่แล้ว +1

    Love for the first time from Tunisia 🇹🇳🇹🇳 I think

  • @kevinhammond9864
    @kevinhammond9864 3 ปีที่แล้ว +19

    I cant help hearing in my head "the professional is insured you are not" 😂

    • @sodinc
      @sodinc 3 ปีที่แล้ว

      Lol

  • @uzairmughal4976
    @uzairmughal4976 3 ปีที่แล้ว +34

    Great Scott to a stupid Engineer like me 1:01: "You should always hire a professional to do electrical work"

  • @XcelentTom.
    @XcelentTom. 3 ปีที่แล้ว

    It's more or less done similarly in the Netherlands. Even though it's quite tedious to do on a daily basis. It's still enjoyable to watch good craftsmanship.

  • @gajananddave3385
    @gajananddave3385 3 ปีที่แล้ว

    I'm from India,we do all the electrical work for our home
    by experience we know the
    How to get right connection
    Like your videos, love from India.

  • @0552131
    @0552131 3 ปีที่แล้ว +41

    This video in a nutshell? CABLEPORN!

    • @breadbad1
      @breadbad1 3 ปีที่แล้ว +1

      Don't be dirty boi🙏

  • @dmacpher
    @dmacpher 3 ปีที่แล้ว +28

    This feels like a shot at electro boom :p

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +9

      Haha well......not really ;-)

    • @dmacpher
      @dmacpher 3 ปีที่แล้ว

      @@greatscottlab wink wink nudge nudge , say no more :p

    • @Helli__
      @Helli__ 3 ปีที่แล้ว +1

      Haha, right. After his recent videos about the patio heater.

  • @fazlerabbi4316
    @fazlerabbi4316 3 ปีที่แล้ว

    That's what I love to see! Practical stuffs!

  • @bringdamage1396
    @bringdamage1396 3 ปีที่แล้ว

    8k after 33 minutes that alot!!! Thanks for the video...I love it!!!! More power💓

  • @Thanos-ic8ki
    @Thanos-ic8ki 3 ปีที่แล้ว +14

    woh i was like only 167 views and then refreshed and bam still the same tho love ur work mate german wiring and japanese tools best combo ever

  • @vojtechkurka4928
    @vojtechkurka4928 3 ปีที่แล้ว +4

    Great video as always.
    What was the reason for using one breaker for both lights and sockets? I would be afraid of losing light when it gets triggered.

  • @Minimalist11Guy
    @Minimalist11Guy ปีที่แล้ว

    Thank you, I learned a few new things. Very well explained.

  • @smirnovamaria9611
    @smirnovamaria9611 3 ปีที่แล้ว

    That was really good!
    I'm a russian electrical engineer, and I loved to see the similarities and differences between two countries typical electrical solutions

    • @smirnovamaria9611
      @smirnovamaria9611 3 ปีที่แล้ว +1

      The most noticeable difference for me was drawing outlets on a plan.
      We draw them 180° rotated, half-circle part to the wall.
      It was very uncanny to see them drawn the other way in the video
      The little diffencies: in russia there aren't any requirements for cutting conductors 5 cm before the boxes. We cut them just before boxes. It looks neater that way too.
      We also usually use cable canals or flexible tubes as a conductor.
      I personally also wouldn't use wago for connecting wires, because they do need maintenance once in a while. I dunno if it's a personal choice or best german practices.

  • @HSRMF
    @HSRMF 3 ปีที่แล้ว +10

    6:17 the true professional use his teath to trim the wires ..

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว +1

      and uninsulated tools thts why its crafts-man not fanny crafts-dresser lol

  • @Luis-gc1if
    @Luis-gc1if 3 ปีที่แล้ว +37

    Thankfully he is using (maybe) the european method, and I'm from Spain, so here we go!

    • @calysagora3615
      @calysagora3615 3 ปีที่แล้ว +10

      Yeah, here in Spain the standard is mostly based on the German standards, but Spanish electricians would never bother to install to code, or install neatly. I have yet to see a Spanish house with an installation I wouldn't rip out immediately if I owned it.

    • @caiarcosbotias1710
      @caiarcosbotias1710 3 ปีที่แล้ว +1

      Ojalá, pero por la poca experiencia que tengo por mucho que el código sea el mismo los electricistas no!

    • @ornessarhithfaeron3576
      @ornessarhithfaeron3576 3 ปีที่แล้ว +2

      As far as I'm aware, everyone in Europe but the Brits use DIN-based standards

    • @AccidentalScience
      @AccidentalScience 3 ปีที่แล้ว +2

      @@ornessarhithfaeron3576 actually it's based on CENELEC standards.

    • @jeremymurphy5023
      @jeremymurphy5023 3 ปีที่แล้ว +1

      Being in Canada, I’ll just have to stay creative and wait for next time. GreatScott!!! Years of enjoyment

  • @LalanDesai
    @LalanDesai 3 ปีที่แล้ว

    Perfect example of clean and perfect work.❤️👍

    • @83hjf
      @83hjf 3 ปีที่แล้ว

      yeah surely those pipes 5cm short off the junction boxes are "clean and perfect", ugh

  • @RoRoTech
    @RoRoTech 2 ปีที่แล้ว

    Super well explained, great job Scott 💪

  • @additivent
    @additivent 3 ปีที่แล้ว +8

    Ah, yes, our daily dose of superior German Engineering.

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +3

      Haha, well....something like that ;-)

  • @Monkeyheadtpc
    @Monkeyheadtpc 3 ปีที่แล้ว +12

    I came to the comment section to get some juicy chastising of how your work is still not according to VDE-norms. But I didn't find any. Good job, it seems.

    • @cfusername
      @cfusername 3 ปีที่แล้ว +2

      I'm sure they will find something. They always do.

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +1

      @@cfusername Haha true ;-)

  • @cartoon-network814
    @cartoon-network814 3 ปีที่แล้ว

    most useful DIY wiring video - thanks (the standards used in Germany are par excellence)

  • @vinayakonimani7628
    @vinayakonimani7628 3 ปีที่แล้ว

    A nice n concise guide, thanks for the video!!👍

  • @Pendaws
    @Pendaws ปีที่แล้ว +1

    Vielen Dank für die Erstellung eines so leicht verständlichen Videos. Ich liebe es, Ihnen bei der Arbeit zuzusehen und gut zu erklären.

  • @JonasKongsted
    @JonasKongsted 3 ปีที่แล้ว +34

    In Denmark we are only allowed to draw 10-13A on 1,5mm2 conductors, depending on our measurements.
    So 16A on 1,5mm2 is a bit surprising to me.

    • @rofo88
      @rofo88 3 ปีที่แล้ว +4

      depending on wire lenght, but his main fuse is just 6A

    • @jaeger0404
      @jaeger0404 3 ปีที่แล้ว +2

      @@rofo88 its B16, so 16A. 16A is standard for outlets

    • @rofo88
      @rofo88 3 ปีที่แล้ว +2

      @@jaeger0404 : Main Fuse, the old one made of ceramic

    • @spellingmistake1
      @spellingmistake1 3 ปีที่แล้ว +5

      In Germany as long as the voltage does not drop more than 3% at the end of the connection, ist fine. So it depends on the cable length
      Otherwise you have to use a thicker kable

    • @JonasKongsted
      @JonasKongsted 3 ปีที่แล้ว +2

      @@spellingmistake1 here in Denmark its 5% on light installations and 3% in other kinds. We just got a new set of rules called DS/EN-60364 and that is should remind alot of your laws in germany. 😊

  • @SamiKankaristo
    @SamiKankaristo 3 ปีที่แล้ว +6

    5:31
    Germany allows 16 A using a 1.5 mm2 wire? In Finland (with mostly the same regulations), 1.5 mm2 wire is only for up to 10 A, and 2.5 mm2 wire is used for up to 16 A.

    • @Robin-ky4lc
      @Robin-ky4lc 3 ปีที่แล้ว

      Yes 1.5mm 16A is fine up to 17m length, except some limitations regarding cable accumulation etc.
      For new buildings, 13A is also common here.

    • @greatscottlab
      @greatscottlab  3 ปีที่แล้ว +1

      Yep 1.5 for 16A is allowed.

    • @bar10005
      @bar10005 3 ปีที่แล้ว

      AFAIK depends on installation type/location - it's allowed in conduits on walls, but if it's inside heat-insulated wall the rating drops down to 14,5 A.

    • @haavard895
      @haavard895 3 ปีที่แล้ว

      it depends on the calculated current of the system, a lot of places 1.5 mm2 cable can carry 16A easly but national regulations (like in finland, and norway, and probbably more places) demands that you use 2.5mm2 wire

    • @SamiKankaristo
      @SamiKankaristo 3 ปีที่แล้ว +1

      Okay, good to know. The different regulations might be due to temperature differences between countries. Germany is a bit warmer year-round than Finland (especially Lapland). And especially with thinner wires, large currents heat up the wire.
      Over time, the temperature changes can fatigue the metal and the insulation, leading to failures. If you're using an extension cable outside in the winter, it's not uncommon for the snow underneath it to melt.

  • @TopDedCenter
    @TopDedCenter 3 ปีที่แล้ว +2

    As an American, This video would have been very helpful when I moved to Germany 6 years ago and rewired my garage from the exact same situation, one dim light and a plug.

  • @nextlifeonearth
    @nextlifeonearth 3 ปีที่แล้ว

    I do this stuff myself usually, even though I am no professional. I didn't know what the German standards are, but I'm happy to see my installation is pretty much the same.
    It is common sense to me. Though I measure most things with a multimeter instead of that specialised thingamajig.

  • @juststeve5542
    @juststeve5542 3 ปีที่แล้ว +19

    10:30 Oh the humanity! Has Germany never heard of glands and grommets? Here in the UK you'd get shouted at for having all those wires hanging out of the ends of the conduit like that!
    There are ways to do corners too!

    • @3ATIVE
      @3ATIVE 3 ปีที่แล้ว +1

      Yeah, not very neat. Maybe they don't require them for external building(s) installations 😜

    • @LeVoDECoM
      @LeVoDECoM 3 ปีที่แล้ว +14

      Not required indoors

    • @juststeve5542
      @juststeve5542 3 ปีที่แล้ว +4

      I know it's not required, the conduit isn't even required, but I've never seen anyone go to the trouble of "half doing" the conduit!
      I would shout at a spark if he did that to my garage!
      (Which would be my brother, but I know he'd never do an install like that).

    • @batmann2o
      @batmann2o 3 ปีที่แล้ว +4

      In Denmark you are not required to use conduits unless the installation are outside and close to the ground (2,5m or below). Most times conduits are used to get the job done faster, just like in the video. If you have lot of parallel wiring in a esthetic un important area like a garage you would use a cable tray.

    • @3ATIVE
      @3ATIVE 3 ปีที่แล้ว +2

      @@juststeve5542 When he smacked in that first vertical at 9:14 I thought, he must be using some huge grommets. Then he started feeding cabling and I was like... Ermmm, hang on!! LOL

  • @joshuahuman1
    @joshuahuman1 3 ปีที่แล้ว +14

    I wish the din rail box and wago connecters were standard in the us

    • @Cryptovariable
      @Cryptovariable 3 ปีที่แล้ว +2

      Be the change you wish to see! I’ve been replacing all wire nuts with wago connectors one-by-one as I install smart switches and USB-C equipped outlets.

    • @astranger448
      @astranger448 3 ปีที่แล้ว

      Wago in the US is not such a good idea. Wago is designed with 240V in mind, where the US is mostly 120V. Half the voltage means twice the current, and a much, much higher risk of overloading a circuit. The US style wiring nut will stand that kind of abuse better.

  • @faelpinho
    @faelpinho 3 ปีที่แล้ว

    It's better than Brazil wiring patterns. Very clean and easy to increase new circuits as well. Thank you!

  • @alhdgysz
    @alhdgysz 3 ปีที่แล้ว +2

    It's good to see a well executed EUROPEAN style electrical job :D

  • @famitory
    @famitory 3 ปีที่แล้ว +20

    the 5cm gaps are an interesting factor. in Canada I've always seen conduit connected structurally to every box, and I suspect you probably aren't allowed to have a pipe end exposed, and must end all pipes in a box of some kind

    • @jbrnds
      @jbrnds 3 ปีที่แล้ว +5

      This is because the 3 x 1.5 mm2 covered wire he used. When you use individual wires you connect the conduits to the box.

    • @famitory
      @famitory 3 ปีที่แล้ว +3

      @@jbrnds the standard wire for homes in canada is called romex, it's the live and neutral in a flat line with the ground in the middle and some insulation around the whole thing, if wire is to be exposed in an "outdoors" location like a garage people either use conduit or this stuff called BX which has a metal armored sheath. my guess based on what i can see in the video is that his wire has much, much thicker insulation around it

    • @Ter_ror
      @Ter_ror 3 ปีที่แล้ว +3

      it depends on what type of installation you do.
      1)For outdoor, garages, offices and most industrial buildings, we use (mostly gray) insulating cables(like Scott uses here). For example XMVk. because they are always Water resistant and really quick & easy to install, and you have them in different types for different use cases like UV resistant or Metal-shields. Those are allowed to be exposed for bends and connecting them to junction boxes.
      2)For houses indoor we mostly use (yellow) pvc piping flexible or solid, or a combination of both. And tose must, just like in Canada, always connect directly to boxes, switches and outlets. After installing the pipes we pull cables tru them. for power every color is separate but we pull them at the same time obviously. And we use the same pipes for ethernet, fiber, telephone and coaxial cables, separate from power.
      You can see why we prefer the first method. It is less work for big installations but it is not very suitable for European type houses.

    • @mariom.9472
      @mariom.9472 3 ปีที่แล้ว +2

      They used for indoor Installation NYM-J, for outdoor its NYY.

    • @iamdave84
      @iamdave84 3 ปีที่แล้ว +2

      @@famitory in Australia we use similar stuff we call TPS. Typically we use 1.5mm² for lighting circuits and 2.5mm² for general power outlets. All 3 sets of stranded conductors are insulated individually with their designated colour, then all 3 are insulated together into a flat white cable. We use 230V power here, similar to Europe's 220V.
      en.m.wikipedia.org/wiki/Thermoplastic-sheathed_cable

  • @stefanatli7769
    @stefanatli7769 3 ปีที่แล้ว +4

    Very nice, this is almost completely identical to how it's done in Iceland, almost all of our electrical is straight from Germany and it's fantastic!

  • @Flyrip
    @Flyrip 3 ปีที่แล้ว

    Thanks for all of your videos. You are incredibly good at teaching all kinds of electronics . I would love a video of how a tig ac/DC welding machine works. I am currently trying to build a hf arc generator for one and the electronics in it are really intriguing.

  • @CTCTraining1
    @CTCTraining1 3 ปีที่แล้ว

    Very tidy job, many thx for the video.

  • @ToTo_ak
    @ToTo_ak ปีที่แล้ว +12

    the only thing missing was that you said something about the 5 safety rules 😅❤

  • @Gigawipf
    @Gigawipf 3 ปีที่แล้ว +6

    I see my own board (old testing order) at 1:43. Heh.

  • @vaibhavkhatri3435
    @vaibhavkhatri3435 3 ปีที่แล้ว

    I really enjoyed it
    Thanks scott

  • @lengaming1651
    @lengaming1651 3 ปีที่แล้ว

    Here in norway it really is the same, but we use screw terminals in the fuse box and don't use those gray pipes in open air. We do lots of these installations at school.

  • @pitor87
    @pitor87 3 ปีที่แล้ว +48

    5:20 I am a bit confused. Are you adding a 16A breaker after a 6A fuse?

    • @evgeniydenisenko2344
      @evgeniydenisenko2344 3 ปีที่แล้ว +5

      Came into comments to ask the same question

    • @R900DZ
      @R900DZ 3 ปีที่แล้ว +5

      They probably replaced the original fuse with one that had a higher rating (16a)

    • @romsthe
      @romsthe 3 ปีที่แล้ว +14

      It's European regulation to have outlets behind a 16A breaker, either with 1.5 mm2 or 2.5 mm2 sections of wire depending on the number of outlets and the voltage drop you might get over the distance. The input 6A fuse is unusual. Fuses themselves are unusual.

    • @MytronixOfficial
      @MytronixOfficial 3 ปีที่แล้ว +8

      It shouldnt be a safety issue, the ground protection of the RCBO is still there and it just means the 6A fuse blows first. But its bad style and annoying to have to replace a fuse when you have a perfect resettable RCBO there. But probably 6A RCBOs are rare and might be more expensive.

    • @mistermartin82
      @mistermartin82 3 ปีที่แล้ว +1

      @@MytronixOfficial 6A RCBO is common in the UK for lighting circuits

  • @SaintPabloBeats
    @SaintPabloBeats 3 ปีที่แล้ว +3

    9:40 the PE wire has to be a little bit longer than the N an L to make sure that the PE wire is the last one that is connected in case the outlet gets teared off the wall by accident

    • @asfaltyka
      @asfaltyka 3 ปีที่แล้ว

      Good advice.

    • @ConradvanderMeer
      @ConradvanderMeer 3 ปีที่แล้ว +2

      Good practice but not necessary, the outlet is designed in such a way that the PE is always the last to release with same wire length.

  • @Simorenarium
    @Simorenarium 3 ปีที่แล้ว +2

    I'd like to mention, in Germany it takes 3,5 Years of Training to become an "official" professional electrical worker.
    During this training or "Ausbilding" you get about 300€ to 700€ per month.
    At the end you will have theoretical and practical exams and when you succeed you get your "Facharbeiterbrief", a smal
    notarised document saying you are a professional electrician.
    This goes for most jobs which have a government controlled training.
    Although pay ranges from 240€ up to 1,200€ as far as I know. I may have missed the point at which minimum wages for trainees have been introduced.

  • @FluxLabsProjects
    @FluxLabsProjects 3 ปีที่แล้ว

    This is really different from UK wiring, and we're not even that far apart! Thanks for the videos!

    • @marzsit9833
      @marzsit9833 3 ปีที่แล้ว

      the uk uses ring circuits, which i have tried to explain to my american co-workers but they just can't understand how it works..

    • @FluxLabsProjects
      @FluxLabsProjects 3 ปีที่แล้ว

      @@marzsit9833 Ring curcuits are evil things. Radial circuits are better i believe.