Deimos Ultra UL Webinar - Part 2

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ย. 2024

ความคิดเห็น • 30

  • @bentley9249
    @bentley9249 5 หลายเดือนก่อน

    Thank you mate 👌

  • @saulgonzalez2223
    @saulgonzalez2223 หลายเดือนก่อน

    I received Error1

  • @jumaniaccessories6538
    @jumaniaccessories6538 11 หลายเดือนก่อน

    I’m from Dubai how r u sir

  • @mrfelonik6839
    @mrfelonik6839 4 หลายเดือนก่อน

    Hi sir, thank you very much for your tutorial. I still have a problem. Mine was down so i bought a new motor and card. it looks like the limit switches are not recognized. While autosetting, it just goes to the stop and then blocks and says KO. What could it be ? thanks

    • @BFTAmericasInc
      @BFTAmericasInc  4 หลายเดือนก่อน

      Hello, so does the word stop come up on display and on the limits itself it should have a L and R and when you are facing the motor the L on the left side and R on the right side. You can also call us when you are at the motor if you need tech support 877-995-8155 option 3. You can also email us at tech@bft-usa.com.

  • @belkocik
    @belkocik 3 ปีที่แล้ว +1

    can I put monostable button (like I got in house for turn on the light) in 60 and 61 pin and then it opens a gate?

    • @BFTAmericasInc
      @BFTAmericasInc  3 ปีที่แล้ว

      As long as the dry contact that is connecting to 60-61 closes for about 1-2 seconds it should be ok. Also, depends how far away it is. If it is to far you might want the contact to close for about 2-3 Seconds.

    • @belkocik
      @belkocik 3 ปีที่แล้ว

      @@BFTAmericasInc about 10 meters away (in my garage). BTW Is it possible to connect shelly1 24v to open and close the gate too? Would you do a video about this?

  • @garygab4800
    @garygab4800 ปีที่แล้ว

    I’m having trouble my gate is not closing all the way I have to manually push it to close

    • @BFTAmericasInc
      @BFTAmericasInc  ปีที่แล้ว

      when the gate stops what does it say on the display.

  • @marcinxt1277
    @marcinxt1277 3 ปีที่แล้ว +1

    How to program the remote control so that the gate opens in three stages
    - Pedestrian
    - Half open
    - Open

    • @BFTAmericasInc
      @BFTAmericasInc  3 ปีที่แล้ว

      Please check out our mitto remote videos.

  • @Huc_009
    @Huc_009 2 ปีที่แล้ว

    Can you tell me how can i configure photocell to be active only when gate closing? Thank you in advance

    • @BFTAmericasInc
      @BFTAmericasInc  2 ปีที่แล้ว

      No problem of course we can help!! If you have a UL version BFT then chances are your photobeam is tested and using 5 wire hook up. If it is, you want to go to the "Logic" menu you want to go to "safe 1" and change that value to the number 5 and push ok. If it is the non UL (or just 4 wire hook up) you want to change your safe setting to the number 4. If you need more assistance please reach out to us at Tech@BFT-USA.com.

  • @hvanhat
    @hvanhat 2 ปีที่แล้ว

    Great videos thanks I just have a question - is there a way to program the remotes so that my one of the buttons has the auto close (TCA) but the other doesn't? (so for times where i want the gate to stay open?) I have the Deimos A 400 V Ultra

    • @BFTAmericasInc
      @BFTAmericasInc  2 ปีที่แล้ว

      You have two options.... Option 1: Use the 4-step logic on the board. It comes default already with 4-step logic active, but just to make sure check in the "Logic" menu that STEP-BY-STEP is set to "0". Now that your set up, the way to use this function is IMMEDIATELY when the gate starts to CLOSE, click the remote and it should stop and stay there and ignore gate timer until you give the gate another activation. Option 2: Purchase a Clonix 2/E wired in receiver and use one button on the remote as normal and then program the second button to the latching command on this receiver. Check video out for option 2 here: th-cam.com/video/2wGhP4pVbTQ/w-d-xo.html
      Hope this helped. If not write us at tech@BFT-USA.com and we will do our best to help you out.

  • @ycho
    @ycho 2 ปีที่แล้ว

    Is there a way to extend the TCA time? like using external timer and hooking it up to the BT600?

    • @BFTAmericasInc
      @BFTAmericasInc  2 ปีที่แล้ว

      Sure, you can hook up a seven day timer or something similar. Just hook it up to the open command. Once the timer turns off, open command goes away and the regular TCA will count down and then close your gate. Hope this helped...

    • @ycho
      @ycho 2 ปีที่แล้ว

      @@BFTAmericasInc my apologies, but how do I access the open command?

  • @Tluanga2008
    @Tluanga2008 2 ปีที่แล้ว

    Hi I got BFT 400, Can I reprogram, how? Is there any reset button?

    • @BFTAmericasInc
      @BFTAmericasInc  2 ปีที่แล้ว +1

      Not really a reset button, but you can press and hold s3 for 5 seconds when ever you change a dipswitch or potentiometer to save changes. Also, you can wire in a N/C button to the 70-71 spot which is the stop command. That command will reset any faults that might have occurred while running.

  • @jfuqua72
    @jfuqua72 3 ปีที่แล้ว

    Can you program this with the button built into the car?

    • @BFTAmericasInc
      @BFTAmericasInc  3 ปีที่แล้ว

      Unfortunately our rolling code technology does not work with homelink, Check out our KHLKIT video! th-cam.com/video/k3ILx5WBON8/w-d-xo.html

    • @jfuqua72
      @jfuqua72 3 ปีที่แล้ว

      @@BFTAmericasInc with the Deimos Utra BT A600 UL can I use the phone app? or does this require another module?

  • @martarodriguez8974
    @martarodriguez8974 3 ปีที่แล้ว

    Having issue with programming. I select my LH and pre select I have it on AR, then on auto select it counts down but gate does not move. After I get a message KO when I click okay message appears ER01 ..... can anyone help

    • @davidburke4303
      @davidburke4303 3 ปีที่แล้ว

      Your magnets or limit switches are not set up correctly

    • @BFTAmericasInc
      @BFTAmericasInc  3 ปีที่แล้ว

      Anything ER01 or ER04 is directly tied to the Photo cells. Please check out our UL phot cell videos to verify proper wiring.

  • @Wpbandy
    @Wpbandy ปีที่แล้ว

    Mine says bar when i hit open

    • @BFTAmericasInc
      @BFTAmericasInc  ปีที่แล้ว

      Does it say bar when you hit the open command or does it move a couple inches then say bar.

  • @jumaniaccessories6538
    @jumaniaccessories6538 11 หลายเดือนก่อน

    Hi